1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720
|
#!/bin/bash
set -e
#set -x
myscript=$(basename $0)
if [ $(id -u) -ne 0 ]; then
echo "$myscript needs root: please use sudo."
exit 1
fi
PRODUCT_NAME=$(dmidecode -s system-product-name)
# Make a CSV file of VD (Megacli Virtual Disk) and the PD (Megacli Physical Drives) they use
# and "guess" the matching device name (by using a counter).
megacli_vd_list2 () {
VD_LIST2=$(mktemp)
F_PDINFO=$(mktemp)
echo "Vd,Pd,Drive,Vdstate,Slot" >${VD_LIST2}
if [ -x /usr/bin/storcli_x64 ] || [ -x /usr/bin/storcli64 ] ; then
# if false ; then
if [ -x /usr/bin/storcli64 ] ; then
STORCLI=/usr/bin/storcli64
elif [ -x /usr/bin/storcli_x64 ] ; then
STORCLI=/usr/bin/storcli_x64
else
echo "Cannot find storcli"
exit 1
fi
COUNT_REAL=0
ALL_CTRLS=$(${STORCLI} /call show J | jq '.["Controllers"][]["Command Status"]["Controller"]' -r | tr '\n' ' ')
MY_DISK_COUNT=0
OLD_DG="blah"
COUNT_REAL=0
for CTL_NUM in ${ALL_CTRLS} ; do
# List non-JBOD first
for SLOTNUM in $(${STORCLI} /c${CTL_NUM}/eall/sall show J | jq -r '.[][0]["Response Data"]["Drive Information"][] | select (.Type != "JBOD") | .["EID:Slt"]') ; do
if [ "${PRODUCT_NAME}" = MZ01-CE1-00 ] ; then
LETTER_VD_NUM=$(( ${COUNT_REAL} + 2 ))
VD_NUM=$(echo ${SLOTNUM} | cut -d: -f2)
else
DG=$(${STORCLI} /c${CTL_NUM}/eall/sall show J | jq -r '.[][0]["Response Data"]["Drive Information"][] | select (."EID:Slt" == "'${SLOTNUM}'") | .["DG"]')
if [ "${DG}" = "-" ] ; then
DG=$(echo "${SLOTNUM}" | cut -d: -f2)
fi
VD_NUM=$(( ${COUNT_REAL} + ${DG} ))
LETTER_VD_NUM=${VD_NUM}
fi
SLOT=$(echo ${SLOTNUM} | cut -d: -f2)
case ${LETTER_VD_NUM} in
0) D=sda ;;
1) D=sdb ;;
2) D=sdc ;;
3) D=sdd ;;
4) D=sde ;;
5) D=sdf ;;
6) D=sdg ;;
7) D=sdh ;;
8) D=sdi ;;
9) D=sdj ;;
10) D=sdk ;;
11) D=sdl ;;
12) D=sdm ;;
13) D=sdn ;;
14) D=sdo ;;
15) D=sdp ;;
16) D=sdq ;;
17) D=sdr ;;
18) D=sds ;;
19) D=sdt ;;
20) D=sdu ;;
21) D=sdv ;;
22) D=sdw ;;
23) D=sdx ;;
24) D=sdy ;;
25) D=sdz ;;
esac
VD_STATE=$(${STORCLI} /c${CTL_NUM}/eall/sall show J | jq -r '.[][0]["Response Data"]["Drive Information"][] | select (."EID:Slt" == "'${SLOTNUM}'") | .["State"]')
echo ${VD_NUM},${SLOT},${D},${VD_STATE},${CTL_NUM}:${SLOTNUM} >>${VD_LIST2}
if [ "${PRODUCT_NAME}" = MZ01-CE1-00 ] ; then
COUNT_REAL=$((${COUNT_REAL} + 1))
else
if [ "${DG}" != "${OLD_DG}" ] ; then
COUNT_REAL=$((${COUNT_REAL} + 1))
fi
OLD_DG=$DG
fi
done
# List JBOD next
for SLOTNUM in $(${STORCLI} /c${CTL_NUM}/eall/sall show J | jq -r '.[][0]["Response Data"]["Drive Information"][] | select (.Type == "JBOD") | .["EID:Slt"]') ; do
VD_NUM=${COUNT_REAL}
SLOT=$(echo ${SLOTNUM} | cut -d: -f2)
case ${COUNT_REAL} in
0) D=sda ;;
1) D=sdb ;;
2) D=sdc ;;
3) D=sdd ;;
4) D=sde ;;
5) D=sdf ;;
6) D=sdg ;;
7) D=sdh ;;
8) D=sdi ;;
9) D=sdj ;;
10) D=sdk ;;
11) D=sdl ;;
12) D=sdm ;;
13) D=sdn ;;
14) D=sdo ;;
15) D=sdp ;;
16) D=sdq ;;
17) D=sdr ;;
18) D=sds ;;
19) D=sdt ;;
20) D=sdu ;;
21) D=sdv ;;
22) D=sdw ;;
23) D=sdx ;;
24) D=sdy ;;
25) D=sdz ;;
esac
VD_STATE=$(${STORCLI} /call/eall/sall show J | jq -r '.[][0]["Response Data"]["Drive Information"][] | select (."EID:Slt" == "'${SLOTNUM}'") | .["State"]')
echo ${VD_NUM},${SLOT},${D},${VD_STATE},${SLOTNUM} >>${VD_LIST2}
COUNT_REAL=$((${COUNT_REAL} + 1))
done
done
return
else
megacli -LdPdInfo -a0 -NoLog | grep -E '^Virtual Drive:|^Slot Number:|^State' >${F_PDINFO}
COUNT_REAL=-1
while read line ; do
# If the line contains : (ie: semicolumn) then it can be parsed
if echo ${line} | grep -q -E "^Virtual Drive:" ; then
VD_NUM=$(echo ${line} | sed "s/^Virtual Drive: //" | cut -d' ' -f1)
COUNT_REAL=$((${COUNT_REAL} + 1))
fi
if echo ${line} | grep -q -E "^State" ; then
VD_STATE=$(echo ${line} | cut -d: -f2 | cut -d' ' -f2)
fi
if echo ${line} | grep -q -E "^Slot Number:" ; then
SLOT=$(echo "${line}" | sed "s/Slot Number: //")
if [ "${PRODUCT_NAME}" = "ThinkSystem SR665" ] ; then
COUNT=$((${COUNT_REAL} + 2))
else
COUNT=${COUNT_REAL}
fi
case ${COUNT} in
0) D=sda ;;
1) D=sdb ;;
2) D=sdc ;;
3) D=sdd ;;
4) D=sde ;;
5) D=sdf ;;
6) D=sdg ;;
7) D=sdh ;;
8) D=sdi ;;
9) D=sdj ;;
10) D=sdk ;;
11) D=sdl ;;
12) D=sdm ;;
13) D=sdn ;;
14) D=sdo ;;
15) D=sdp ;;
16) D=sdq ;;
17) D=sdr ;;
18) D=sds ;;
19) D=sdt ;;
20) D=sdu ;;
21) D=sdv ;;
22) D=sdw ;;
23) D=sdx ;;
24) D=sdy ;;
25) D=sdz ;;
esac
echo ${VD_NUM},${SLOT},${D},${VD_STATE} >>${VD_LIST2}
fi
done <${F_PDINFO}
rm -f ${F_PDINFO}
fi
}
megacli_vd_list () {
megacli_vd_list2
VD_LIST=$(mktemp)
echo "Vd,Pd,Drive,Vdstate,Slot" >${VD_LIST}
# cat ${VD_LIST2} | q -d, -H "SELECT * FROM - ORDER BY vd" >>${VD_LIST}
cat ${VD_LIST2} | q -d, -H "SELECT * FROM -" >>${VD_LIST}
rm -f ${VD_LIST2}
}
# Make a CSV file of the PD (Megacli Physical Disks) and their properties
megacli_pd_list2 () {
PD_LIST2=$(mktemp -t ${myscript}_pd-list.XXXXXX)
echo "Slot,Model,Serial,Size,State,Spun,Firmware" >${PD_LIST2}
if [ -x /usr/bin/storcli_x64 ] || [ -x /usr/bin/storcli64 ] ; then
if [ -x /usr/bin/storcli64 ] ; then
STORCLI=/usr/bin/storcli64
elif [ -x /usr/bin/storcli_x64 ] ; then
STORCLI=/usr/bin/storcli_x64
else
echo "Cannot find storcli"
exit 1
fi
ALL_CTRLS=$(${STORCLI} /call show J | jq '.["Controllers"][]["Command Status"]["Controller"]' -r | tr '\n' ' ')
for CTL_NUM in ${ALL_CTRLS} ; do
PD_LIST2_TMP=$(mktemp -t ${myscript}_pdlist-tmp.XXXXXX)
for STORCLI_DRIVE in $(${STORCLI} /call/eall/sall show all nolog J | jq -r '.["Controllers"]['${CTL_NUM}']["Response Data"]|to_entries[]|.key' | grep -v "Detailed Information" | awk '{print $2}') ; do
DRIVE_INFO=$(mktemp -t ${myscript}_storcli-drive-info.XXXXXX)
${STORCLI} ${STORCLI_DRIVE} show all J | jq -r '.["Controllers"][0]["Response Data"]["Drive '${STORCLI_DRIVE}'"]' >${DRIVE_INFO}
DRIVE_DETAILED_INFO=$(mktemp -t ${myscript}_storcli-drive-detailed-info.XXXXXX)
${STORCLI} ${STORCLI_DRIVE} show all J | jq -r '.["Controllers"][0]["Response Data"]["Drive '${STORCLI_DRIVE}' - Detailed Information"]'>${DRIVE_DETAILED_INFO}
if echo "${STORCLI_DRIVE}" | grep -q -E '^/c[0-9]+/e[0-9]+/s[0-9]+$' ; then
SLOT_ENCL=$(echo "${STORCLI_DRIVE}" | cut -d/ -f3 | sed 's/e//')
SLOT_SLOT=$(echo "${STORCLI_DRIVE}" | cut -d/ -f4 | sed 's/s//')
SLOT_NUM_REAL=${SLOT_ENCL}:${SLOT_SLOT}
else
SLOT_NUM_REAL=$(cat ${DRIVE_INFO} | jq -r '.[]["DID"]')
fi
MODEL=$(cat ${DRIVE_INFO} | jq -r '.[]["Model"]' | sed -e 's/[ \t]*$//')
SERIAL=$(cat ${DRIVE_DETAILED_INFO} | jq -r '.["Drive '${STORCLI_DRIVE}' Device attributes"]["SN"]' | sed -e 's/[ \t]*$//')
SIZE=$(cat ${DRIVE_DETAILED_INFO} | jq -r '.["Drive '${STORCLI_DRIVE}' Device attributes"]["Raw size"]')
STATE=$(cat ${DRIVE_INFO} | jq -r '.[]["State"]')
SPUN=$(cat ${DRIVE_INFO} | jq -r '.[]["Sp"]')
FW=$(cat ${DRIVE_DETAILED_INFO} | jq -r '.["Drive '${STORCLI_DRIVE}' Device attributes"]["Firmware Revision"]')
echo "\"${CTL_NUM}:${SLOT_NUM_REAL}\",\"${MODEL}\",\"${SERIAL}\",\"${SIZE}\",\"${STATE}\",\"${SPUN}\",\"${FW}\"" >>${PD_LIST2_TMP}
rm -f ${DRIVE_INFO}
done
cat ${PD_LIST2_TMP} | sort >>${PD_LIST2}
rm -f ${PD_LIST2_TMP}
set +x
done
return
fi
ENCLOSURE=$(megacli -EncInfo -aALL -NoLog | awk '/Device ID/ {print $4}' | head -n 1)
for SLOT_NUM_REAL in $(megacli -pdlist -a0 -NoLog | grep "Slot Number:" | cut -d':' -f2 | awk '{print $1}') ; do
if [ "${PRODUCT_NAME}" = "ThinkSystem SR665" ] ; then
case "${SLOT_NUM_REAL}" in
0|1|2|3|4|5|6|7|8|9|10|11)
SLOT_NUM=${SLOT_NUM_REAL}
;;
24) SLOT_NUM=12 ;;
25) SLOT_NUM=13 ;;
26) SLOT_NUM=14 ;;
27) SLOT_NUM=15 ;;
*) SLOT_NUM=${SLOT_NUM_REAL} ;;
esac
else
SLOT_NUM=${SLOT_NUM_REAL}
fi
SMT_OUT=$(mktemp)
smartctl -a -d megaraid,${SLOT_NUM} /dev/sda >${SMT_OUT} || true
MODEL=$(cat ${SMT_OUT} | grep -E "^Device Model|^Product" | sed -e 's/^Device Model: //' -e 's/^Product: //')
SERIAL=$(cat ${SMT_OUT} | grep "^Serial [nN]umber" | sed 's/^Serial [nN]umber:[ ]*//')
SIZE=$(cat ${SMT_OUT} | grep "^User Capacity:" | cut -d'[' -f2 | cut -d']' -f1)
FW=$(cat ${SMT_OUT} | grep -m1 -e "^Revision:" -e "^Firmware Version" | awk '{ print $NF }')
rm -f ${SMT_OUT}
FULL_STATE=$(megacli -PDInfo -PhysDrv [${ENCLOSURE}:${SLOT_NUM_REAL}] -aALL -NoLog | grep -E '^Firmware state: ' | sed 's/Firmware state: //')
STATE=$(echo ${FULL_STATE} | cut -d, -f1)
SPUN=$(echo ${FULL_STATE} | cut -d, -f2 | awk '{$1=$1;print}')
echo "\"${SLOT_NUM_REAL}\",\"${MODEL}\",\"${SERIAL}\",\"${SIZE}\",\"${STATE}\",\"${SPUN}\",\"${FW}\"" >>${PD_LIST2}
done
# cat ${PD_LIST2}
}
megacli_pd_list () {
megacli_pd_list2
PD_LIST=$(mktemp)
echo "Slot,Model,Serial,Size,State,Spun,Firmware" >${PD_LIST}
cat ${PD_LIST2} | q -d, -H "SELECT * FROM - ORDER BY Slot" >>${PD_LIST}
rm -f ${PD_LIST2}
}
show_disk_output_normal_dev () {
local dsize dmodel dserial DISK_NAME MY_SMARTCTL_TMP dfw
local oci_sort_name=${1}
dsize=""
dmodel=""
dserial=""
DISK_NAME=$(basename $(realpath /dev/disk/oci-sort/${oci_sort_name}))
MY_SMARTCTL_TMP=$(mktemp -t oci-hdd-maint-smartctl.XXXXXX)
smartctl -a /dev/${DISK_NAME} >${MY_SMARTCTL_TMP} || true
dmodel=$(cat ${MY_SMARTCTL_TMP} | grep "Device Model" | sed 's/Device Model: //')
if [ -z "${dmodel}" ] ; then
dmodel=$(cat ${MY_SMARTCTL_TMP} | grep "Product:" | sed 's/Product: //')
fi
dserial=$(cat ${MY_SMARTCTL_TMP} | grep "Serial Number" | sed 's/Serial Number: //')
if [ -z "${dserial}" ] ; then
dserial=$(cat ${MY_SMARTCTL_TMP} | grep "Serial number:" | sed 's/Serial number: //')
fi
dsize=$(cat ${MY_SMARTCTL_TMP} | grep "User Capacity" | cut -d'[' -f2 | cut -d']' -f1 | sed 's#,#.#')
dfw=$(cat ${MY_SMARTCTL_TMP} | grep -m1 -e "^Revision:" -e "^Firmware Version" | awk '{ print $NF }')
echo ${oci_sort_name},${DISK_NAME},$dsize,$dmodel,$dserial,$dfw
}
show_disk_status () {
if [ "${PRODUCT_NAME}" = "ProLiant DL345 Gen11" ] ; then
echo "oci_name,current_name,Size,Model,Serial,Firmware"
if ! [ -d /dev/disk/oci-sort ] ; then
echo "Error: no /dev/disk/oci-sort."
exit 1
fi
for ociname in $(ls -v /dev/disk/oci-sort/) ; do
show_disk_output_normal_dev ${ociname}
done
elif [ "${PRODUCT_NAME}" != "ThinkSystem SR665" ] && lshw -class storage -json 2>/dev/null | jq -r '.[]["id"]' | grep -q "raid" ; then
# Make a VD list CSV with output: vd,pd,drive
megacli_vd_list
# Make PD list CSV with output: Slot,Model,Serial,Size,State,Spun
megacli_pd_list
# LEFT JOIN both with a single q command
(echo "PD,VD,VDState,Drive,Model,Serial,Size,State,Spun,Firmware";q -H -d, "SELECT pd.Slot, vd.Vd, pd.State, vd.Drive, pd.Model, pd.Serial, pd.Size, vd.Vdstate, pd.Spun, pd.Firmware FROM ${PD_LIST} pd JOIN ${VD_LIST} vd ON (vd.Slot = pd.Slot)")
# rm both temp CSV files
rm ${VD_LIST}
rm ${PD_LIST}
else
# echo "No raid card"
if [ -d /dev/disk/oci-sort ] ; then
echo "oci_name,current_name,Size,Model,Serial,Firmware"
for ociname in $(ls -v /dev/disk/oci-sort/) ; do
show_disk_output_normal_dev ${ociname}
done
else
echo "devname,Logical_ID,Size,Model,Serial,Firmware"
for i in $(ls -v /dev/disk/by-path/ | grep -v part | grep -v usb) ; do
dsize=""
dmodel=""
dserial=""
LOGICAL_ID=$(echo $i | cut -d: -f3)
DISK_NAME=$(basename $(realpath /dev/disk/by-path/$i))
MY_SMARTCTL_TMP=$(mktemp -t oci-hdd-maint-smartctl.XXXXXX)
if [ ""$(lsscsi -g | grep /dev/${DISK_NAME} | awk '{print $3}') = "HPE" ] ; then
DEVID=$(lsscsi | grep /dev/${DISK_NAME} | cut -d] -f1 | cut -d: -f4)
SMARTCTL_MINUS_D_OPT="-d cciss,${DEVID}"
else
SMARTCTL_MINUS_D_OPT=""
fi
smartctl ${SMARTCTL_MINUS_D_OPT} -a /dev/${DISK_NAME} >${MY_SMARTCTL_TMP} || true
dmodel=$(cat ${MY_SMARTCTL_TMP} | grep "Device Model" | sed 's/Device Model: //')
if [ -z "${dmodel}" ] ; then
dmodel=$(cat ${MY_SMARTCTL_TMP} | grep "Product:" | sed 's/Product: //')
fi
dserial=$(cat ${MY_SMARTCTL_TMP} | grep "Serial Number" | sed 's/Serial Number: //')
if [ -z "${dserial}" ] ; then
dserial=$(cat ${MY_SMARTCTL_TMP} | grep "Serial number:" | sed 's/Serial number: //')
fi
dsize=$(cat ${MY_SMARTCTL_TMP} | grep "User Capacity" | cut -d'[' -f2 | cut -d']' -f1 | sed 's#,#.#')
dfw=$(cat ${MY_SMARTCTL_TMP} | grep -m1 -e "^Revision:" -e "^Firmware Version" | awk '{ print $NF }')
echo ${DISK_NAME},${LOGICAL_ID},$dsize,$dmodel,$dserial,$dfw
rm ${MY_SMARTCTL_TMP}
done
fi
fi
}
wait_until_mounted () {
local MOUNT_POINT TIMESTAMP_TIMEOUT
MOUNT_POINT=${1}
TIMESTAMP_TIMEOUT=$(date -d "now + 30 sec" +%s)
while ! mountpoint -q "${MOUNT_POINT}" && [ $(date +%s) -lt "${TIMESTAMP_TIMEOUT}" ] ; do
sleep 1
done
if ! mountpoint -q "${MOUNT_POINT}" ; then
echo "Device not mounted after the mount command and 30 seconds timeout: exiting."
exit 1
fi
}
replace_disk () {
# Fix duplicate fstab lines
if [ -n ""$(uniq -D /etc/fstab) ] ; then
TMPFILE_DUP=$(mktemp -t $(basefile $0)-fix-dup-lines.XXXXXX)
awk '!seen[$0]++' /etc/fstab >${TMPFILE_DUP}
cat ${TMPFILE_DUP} >/etc/fstab
rm -f ${TMPFILE_DUP}
fi
OLD_DISK=$1
if [ -d /dev/disk/oci-sort ] ; then
REALDISK=$(basename $(realpath /dev/disk/oci-sort/${OLD_DISK}))
else
REALDISK=${OLD_DISK}
fi
OLD_UUID=$(cat /etc/fstab | grep -m1 /srv/node/${OLD_DISK} | awk '{print $1}' | sed -e 's/[#]*UUID=//')
echo "===> Checking new disk firmware version"
# Check FW release first
# No RAID case first.
if [ "${PRODUCT_NAME}" != "ThinkSystem SR665" ] && ! lshw -class storage -json 2>/dev/null | jq -r '.[]["id"]' | grep -q "raid" ; then
if [ -x /usr/bin/disk-firmware-updater ] ; then
disk-firmware-updater $REALDISK
else
echo "disk-firmware-installer not installed"
fi
# rm -f ${MY_SMARTCTL_TMP}
fi
echo "===> Formating /dev/${REALDISK} (for /srv/node/${OLD_DISK}) with UUID ${OLD_UUID}"
mkfs.xfs -f -m uuid=${OLD_UUID} /dev/${REALDISK}
echo "===> Uncommenting from fstab"
sed -i "s/[#]*UUID=${OLD_UUID}/UUID=${OLD_UUID}/" /etc/fstab
echo "===> Reloading systemd after fstab edit"
systemctl daemon-reload
echo "===> Mounting /srv/node/${OLD_DISK}"
mount "/srv/node/${OLD_DISK}"
wait_until_mounted "/srv/node/${OLD_DISK}"
echo "===> Changing disk's owner"
chown swift:swift "/srv/node/${OLD_DISK}"
echo "===> Truncating /var/log/kern-legacy.log"
if [ -e /var/log/kern-legacy.log ] ; then
echo -n "" >/var/log/kern-legacy.log
fi
}
usage () {
echo " -l : list devices (columns output)"
echo " -csv : list devices (csv output)"
echo " -s <ID> : setup RAID device"
echo " -y <ID/sdX> : prepare disk for removal for HDD in slot <ID> or /dev/sdX"
echo " (ie: megacli or hdparm commands)"
echo " -u <ID> : stop blinking LED for HDD in slot <ID>"
echo "-r <replacement-hdd>: format and mount <replacement-hdd>"
echo " -pdlist-csv: output physical disks list in CSV format"
echo " -pdlist: output physical disks in table format"
echo " -vdlist-csv: output virtual disks in CSV format"
echo " -vdlist: output virtual disks in table format"
exit 1
}
if [ "${1}" = "-pdlist-csv" ] ; then
megacli_pd_list
cat ${PD_LIST}
rm -f ${PD_LIST}
exit 0
fi
if [ "${1}" = "-pdlist" ] ; then
megacli_pd_list
cat ${PD_LIST} | csvlook --blanks -I
rm -f ${PD_LIST}
exit 0
fi
if [ "${1}" = "-vdlist-csv" ] ; then
megacli_vd_list
cat ${VD_LIST}
rm -f ${VD_LIST}
exit 0
fi
if [ "${1}" = "-vdlist" ] ; then
megacli_vd_list
cat ${VD_LIST} | csvlook --blanks -I
rm -f ${VD_LIST}
exit 0
fi
if [ "${1}" = "-csv" ] ; then
show_disk_status
exit 0
else
case ${1} in
"-h")
usage
;;
"-s")
if [ -z "${2}" ] ; then
usage
fi
if [ ""$(lshw -class storage -json 2>/dev/null | jq -r '.[]["id"]' | head -n1) = "raid" ] ; then
echo "Setting up RAID for device ${2}..."
megacli -DiscardPreservedCache -Lall -a0
megacli -CfgLdAdd -r0[32:${2}] WB RA Direct -a0
else
echo "Didn't detect hardware RAID"
exit 1
fi
;;
"-l")
$0 -csv | csvlook --blanks -I
case "${PRODUCT_NAME}" in
"PowerEdge R720xd")
echo "HDD (PD) disposition:"
echo "Col1,Col2,Col3,Col4
0,3,6,9
1,4,7,10
2,5,8,11" | csvlook --blanks -I
;;
"PowerEdge R740xd")
echo "HDD disposition:"
echo "Col1,Col2,Col3,Col4
sda,sdd,sdg,sdj
sdb,sde,sdh,sdk
sdc,sdf,sdi,sdl" | csvlook --blanks -I
;;
"CL2800 Gen10")
echo "HDD disposition:"
echo "Col1,Col2,Col3,Col4
sda,sdb,sdc,sdd
sdg,sdh,sdi,sdj
sdk,sdl,sdm,sdn" | csvlook --blanks -I
echo "Sometimes, with inverted cabling:"
echo "Col1,Col2,Col3,Col4
sdg,sdh,sdi,sdj
sdk,sdl,sdm,sdn
sda,sdb,sdc,sdd" | csvlook --blanks -I
;;
"ProLiant DL345 Gen11")
echo "HDD disposition (oci_name, front panel):"
echo "Box,Bay1,Bay2,Bay3,Bay4
1,sda,sdb,sdc,sdd
2,sde,sdf,sdg,sdh
3,sdi,sdj,sdk,sdl" | csvlook --blanks -I
echo "HDD disposition (oci_name, back panel):"
echo "Box,Bay1,Bay2,Bay3,Bay4
8,sdm,sdn,sdo,sdp" | csvlook --blanks -I
;;
"ProLiant DL385 Gen10 Plus")
echo "HDD disposition (oci_name, front panel):"
echo "Col1,Col2,Col3,Col4
sdc,sdd,sde,sdf
sdg,sdh,sdi,sdj
sdk,sdl,sdm,sdn" | csvlook --blanks -I
echo "SSD disposition (oci_name, back panel):"
echo "---------------------------------------"
echo "sda"
echo "sdb"
;;
# See https://thinksystem.lenovofiles.com/help/topic/7D2W/sr665_setup_guide.pdf
# page 45 and 64
"ThinkSystem SR665")
echo "HDD disposition (oci_name, front panel):"
echo "Col1,Col2,Col3,Col4
sdc,sdf,sdi,sdl
sdd,sdg,sdj,sdm
sde,sdh,sdk,sdn" | csvlook --blanks -I
echo "HDD disposition (oci_name, back panel):"
echo "Col1,Col2,Col3,Col4
sdo,sdp,sdq,sdr" | csvlook --blanks -I
;;
"MZ01-CE1-00")
echo 'HDD disposition (oci_name):
/ sde / sdf | sdd \ sdc \
/ sdi / sdj | sdh \ sdg \
-------d-r-a-w-e-r---0-------
/ sdm / sdn | sdl \ sdk \
/ sdq / sdr | sdp \ sdo \
-------d-r-a-w-e-r---1-------
/ sdu / sdv | sdt \ sds \
/ sdy / sdz | sdx \ sdw \
-------d-r-a-w-e-r---2-------
System drive slots (seen from back):
sda (left), sdb (right)'
;;
*)
;;
esac
exit 0
;;
"-r")
if [ -z "${2}" ] ; then
usage
fi
# if [ -z "${3}" ] ; then
# usage
# fi
replace_disk ${2}
;;
"-y")
if [ ""$(lshw -class storage -json 2>/dev/null | jq -r '.[]["id"]' | head -n1) = "raid" ] ; then
ENCLOSURE=$(megacli -EncInfo -aALL -NoLog | awk '/Device ID/ {print $4}')
case ${2} in
0|1|2|3|4|5|6|7|8|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27|28|29|30|31|32|33|34|35|36|37|38|39|40|41|42|43|44|45|46|47|48|49|50|51|52|53|54|55|56|57|58|59|60|61|62|63)
echo "Powering off the drive in slot ${2}"
megacli -PDOffline -PhysDrv [${ENCLOSURE}:${2}] -aall
echo "Prepare the drive in slot ${2} for removal"
megacli -PDPrpRmv -PhysDrv [${ENCLOSURE}:${2}] -aall
echo "Making the LED of HDD ${2} blink."
megacli -PdLocate -start -PhysDrv [${ENCLOSURE}:${2}] -aall
exit 0
;;
*)
echo "HDD slot not recognized: exiting."
exit 1
;;
esac
else
if [ -d /dev/disk/oci-sort ] ; then
hdparm -y /dev/${2} || true
else
case ${2} in
sda|sdb|sdc|sdd|sde|sdf|sdg|sdh|sdi|sdj|sdk|sdl|sdm|sdn|sdo|sdp|sdq|sdr|sds|sdt|sdu|sdv|sdw|sdx|sdy|sdz)
echo "Force ${2} to immediately enter the low power consumption standby mode, usually causing it to spin down."
hdparm -y /dev/${2} || true
VENDOR=$(dmidecode -s system-manufacturer)
if [ "${VENDOR}" = "Dell Inc." ] && [ $(racadm get storage.Controller.1 | grep -i NonRAID | cut -d= -f2 | cut -d'#' -f1) = NonRAID.Integrated.1-1 ] ; then
case ${2} in
sda) ID="Disk.Bay.0:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdb) ID="Disk.Bay.1:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdc) ID="Disk.Bay.2:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdd) ID="Disk.Bay.3:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sde) ID="Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdf) ID="Disk.Bay.5:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdg) ID="Disk.Bay.6:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdh) ID="Disk.Bay.7:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdi) ID="Disk.Bay.8:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdj) ID="Disk.Bay.9:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdk) ID="Disk.Bay.10:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdl) ID="Disk.Bay.11:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdm) ID="Disk.Bay.12:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdn) ID="Disk.Bay.13:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdo) ID="Disk.Bay.14:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdp) ID="Disk.Bay.15:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdq) ID="Disk.Bay.16:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdr) ID="Disk.Bay.17:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sds) ID="Disk.Bay.18:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdt) ID="Disk.Bay.19:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdu) ID="Disk.Bay.20:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdv) ID="Disk.Bay.21:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdw) ID="Disk.Bay.22:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdx) ID="Disk.Bay.23:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdy) ID="Disk.Bay.24:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdz) ID="Disk.Bay.25:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
*) exit 0;;
esac
racadm storage blink:${ID}
fi
exit 0
;;
*)
echo "HDD name not recognized: exiting."
exit 1
;;
esac
fi
fi
;;
"-u")
if [ -d /dev/disk/oci-sort ] ; then
echo "not supported with this hardware"
else
if [ ""$(lshw -class storage -json 2>/dev/null | jq -r '.[]["id"]' | head -n1) = "raid" ] ; then
ENCLOSURE=$(megacli -EncInfo -aALL -NoLog | awk '/Device ID/ {print $4}')
case ${2} in
0|1|2|3|4|5|6|7|8|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27|28|29|30|31|32|33|34|35|36|37|38|39|40|41|42|43|44|45|46|47|48|49|50|51|52|53|54|55|56|57|58|59|60|61|62|63)
echo "Stop the blinking of the LED of HDD ${2}."
megacli -PdLocate -stop -PhysDrv [${ENCLOSURE}:${2}] -aall
exit 0
;;
*)
echo "HDD slot not recognized: exiting."
exit 1
;;
esac
else
VENDOR=$(dmidecode -s system-manufacturer)
if [ "${VENDOR}" = "Dell Inc." ] && [ $(racadm get storage.Controller.1 | grep -i NonRAID | cut -d= -f2 | cut -d'#' -f1) = NonRAID.Integrated.1-1 ] ; then
case ${2} in
sda) ID="Disk.Bay.0:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdb) ID="Disk.Bay.1:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdc) ID="Disk.Bay.2:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdd) ID="Disk.Bay.3:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sde) ID="Disk.Bay.4:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdf) ID="Disk.Bay.5:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdg) ID="Disk.Bay.6:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdh) ID="Disk.Bay.7:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdi) ID="Disk.Bay.8:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdj) ID="Disk.Bay.9:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdk) ID="Disk.Bay.10:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdl) ID="Disk.Bay.11:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdm) ID="Disk.Bay.12:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdn) ID="Disk.Bay.13:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdo) ID="Disk.Bay.14:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdp) ID="Disk.Bay.15:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdq) ID="Disk.Bay.16:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdr) ID="Disk.Bay.17:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sds) ID="Disk.Bay.18:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdt) ID="Disk.Bay.19:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdu) ID="Disk.Bay.20:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdv) ID="Disk.Bay.21:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdw) ID="Disk.Bay.22:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdx) ID="Disk.Bay.23:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdy) ID="Disk.Bay.24:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
sdz) ID="Disk.Bay.25:Enclosure.Internal.0-1:NonRAID.Integrated.1-1" ;;
*) exit 0;;
esac
racadm storage unblink:${ID}
exit 0
else
echo "This is not possible for non-raid config."
exit 1
fi
fi
fi
;;
*)
usage
;;
esac
fi
|