1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55
|
<?xml version="1.0" encoding="utf-8"?>
<!--http://www.benext.eu/static/manual/heatingcontrol.pdf-->
<Product xmlns='http://code.google.com/p/open-zwave/'>
<!-- Configuration -->
<CommandClass id="112">
<Value type="byte" genre="config" instance="1" index="1" label="Set to Default" value="-1">
<Help>Set all configuration values to default values (factory settings).</Help>
</Value>
<Value type="byte" genre="config" instance="1" index="2" label="Data request interval" value="20" size="1">
<Help>The interval that data is requested (and therefore updated) from the thermostat and boiler. Value in seconds. </Help>
</Value>
<Value type="byte" genre="config" instance="1" index="3" label="T room update difference" value="1" size="1">
<Help>The value that the room temperature must differ (compared to his previous send value) before an unsolicited room temperature report is send to the associated node. Value in 0.1 °C. </Help>
</Value>
<Value type="byte" genre="config" instance="1" index="4" label="T setpoint update difference" value="5" size="1">
<Help>The value that the temperature setpoint must differ (compared to his previous send value) before an unsolicited temperature setpoint report is send to the associated node. Value in 0.1 °C .</Help>
</Value>
<Value type="list" genre="config" instance="1" index="5" label="Unsolicited CRC" value="1">
<Help>TConfigure if the unsolicited reports are send with the CRC-16 encapsulation. Not that the receiving node should support this encapsulation to parse the Z-Wave frame!</Help>
<Item label="0x00 (disabled)" value="0"/>
<Item label="0x01 – 0xFF: enabled" value="1"/>
</Value>
<Value type="list" genre="config" instance="1" index="6" label="Type of 'special' thermostat" value="0">
<Help>Type of 'special' thermostat: NOTE: when remeha Celcia 20 support is set then any other thermostat can not be set (!) NOTE2: when Remeha Celcia 20 gives 'Fout 203' send cfg value again</Help>
<Item label="0x00: No special" value="0"/>
<Item label="0x01: Remeha Celcia 20" value="1"/>
<Item label="0x02: Honeywell (rounded temperatures)" value="2"/>
</Value>
<Value type="list" genre="config" instance="1" index="9" label="Enable/Disable thermostat schedule" value="0">
<Help>Enable/Disable thermostat schedule inside the heatingcontroller.</Help>
<Item label="0x00: Disable thermostat schedule" value="0"/>
<Item label="0x01 - OFF: Enable thermostat schedule" value="1"/>
</Value>
</CommandClass>
<!-- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2 firmware update not supported -->
<CommandClass id="122" getsupported="false" />
<!-- Association Groups -->
<CommandClass id="133">
<Associations num_groups="1">
<Group index="1" max_associations="5" label="Group 1" />
</Associations>
</CommandClass>
</Product>
|