File: icetDiagnostics.3

package info (click to toggle)
paraview 5.4.1%2Bdfsg4-3.1
  • links: PTS, VCS
  • area: main
  • in suites: buster
  • size: 218,616 kB
  • sloc: cpp: 2,331,508; ansic: 322,365; python: 111,051; xml: 79,203; tcl: 47,013; yacc: 4,877; java: 4,438; perl: 3,238; sh: 2,920; lex: 1,908; f90: 748; makefile: 273; pascal: 228; objc: 83; fortran: 31
file content (97 lines) | stat: -rw-r--r-- 2,023 bytes parent folder | download | duplicates (3)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
'\" t
.\" Manual page created with latex2man on Mon Sep 22 15:51:53 MDT 2014
.\" NOTE: This file is generated, DO NOT EDIT.
.de Vb
.ft CW
.nf
..
.de Ve
.ft R

.fi
..
.TH "icetDiagnostics" "3" "August  9, 2010" "\fBIceT \fPReference" "\fBIceT \fPReference"
.SH NAME

\fBicetDiagnostics \-\- change diagnostic reporting level.\fP
.PP
.SH Synopsis

.PP
#include <IceT.h>
.PP
.TS H
l l l .
void \fBicetDiagnostics\fP(	IceTBitField	\fImask\fP  );
.TE
.PP
.SH Description

.PP
Sets what diagnostic message are printed to standard output. The 
messages to be printed out are defined by \fImask\fP\&.
\fImask\fP
consists of flags that are OR\-ed together. The valid flags are: 
.TP
\fBICET_DIAG_OFF\fP
 A zero flag used to indicate that no diagnostic messages are desired. 
.TP
\fBICET_DIAG_ERRORS\fP
 Print messages associated with anomalous conditions. 
.TP
\fBICET_DIAG_WARNINGS\fP
 Print messages associated with conditions that are unexpected or may lead 
to errors. Implicitly turns on \fBICET_DIAG_ERRORS\fP\&.
.TP
\fBICET_DIAG_DEBUG\fP
 Print frequent messages concerning the status of \fBIceT \fP\&.Implicitly 
turns on \fBICET_DIAG_ERRORS\fP
and \fBICET_DIAG_WARNINGS\fP\&.
.TP
\fBICET_DIAG_ROOT_NODE\fP
 Print messages only on the node with a process rank of 0. This is the 
default if neither \fBICET_DIAG_ROOT_NODE\fP
nor 
\fBICET_DIAG_ALL_NODES\fP
is set. 
.TP
\fBICET_DIAG_ALL_NODES\fP
 Print messages all every nodes. 
.TP
\fBICET_DIAG_FULL\fP
 Turn on all diagnostic messages on all nodes. 
.PP
The default flags are \fBICET_DIAG_ALL_NODES\fP
| 
\fBICET_DIAG_WARNINGS\fP\&.
.PP
.SH Errors

.PP
None. 
.PP
.SH Warnings

.PP
None. 
.PP
.SH Bugs

.PP
None known. 
.PP
.SH Copyright

Copyright (C)2003 Sandia Corporation 
.PP
Under the terms of Contract DE\-AC04\-94AL85000 with Sandia Corporation, the 
U.S. Government retains certain rights in this software. 
.PP
This source code is released under the New BSD License. 
.PP
.SH See Also

.PP
\fIicetGetError\fP(3)
.PP
.\" NOTE: This file is generated, DO NOT EDIT.