File: 041

package info (click to toggle)
pcp 7.1.0-1
  • links: PTS
  • area: main
  • in suites: forky, sid
  • size: 252,748 kB
  • sloc: ansic: 1,483,656; sh: 182,366; xml: 160,462; cpp: 83,813; python: 24,980; perl: 18,327; yacc: 6,877; lex: 2,864; makefile: 2,738; awk: 165; fortran: 60; java: 52
file content (166 lines) | stat: -rwxr-xr-x 4,094 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
#! /bin/sh
# PCP QA Test No. 041
# Test $PCP_RC_DIR pmcd and pmlogger start
#
# Copyright (c) 1995-2002 Silicon Graphics, Inc.  All Rights Reserved.
#

seq=`basename $0`
echo "QA output created by $seq"

# get standard filters
. ./common.product
. ./common.filter
. ./common.check

[ $PCP_PLATFORM = mingw ] && _notrun "Process stop signal not available on Win32"
[ $PCP_PLATFORM = solaris ] && _notrun "SIGSTOP handled differently on solaris"

_filter()
{
    tee -a $seq_full \
    | _filter_pmcd_log \
    | sed \
	-e '/^ *$/d' \
	-e 's/ -t [0-9][0-9]* / /' \
	-e '/UID/d' \
	-e '/UNAME/d' \
	-e '/USER/d' \
	-e '/host/s/host "[^"]*"/host SOMEHOST/' \
	-e 's/^ *root[^/]*\//    USERNAME ... \//' \
	-e 's/^ *pcp[^/]*\//    USERNAME ... \//' \
	-e 's/pmcd -.*/pmcd/' \
	-e '/__pmGetPDU:.*illegal PDU len=0/d' \
    | _filter_pcp_start
}

_expect()
{
    echo "" | tee -a $seq_full
    echo "### Expect: $* ###" | tee -a $seq_full
    echo "" | tee -a $seq_full
}

status=1
_needclean=true
TAG=000666000magic
LOGGING_DIR="$PCP_ARCHIVE_DIR"
trap "_cleanup" 0 1 2 3 15

_stop_auto_restart pmcd

_cleanup()
{
    if $_needclean
    then
	[ -f $tmp.control ] && \
	    $sudo cp $tmp.control $PCP_PMLOGGERCONTROL_PATH
	[ -d $tmp.control.d ] && \
	    $sudo mv $tmp.control.d $PCP_PMLOGGERCONTROL_PATH.d
	_service pmcd start 2>&1 | _filter_pcp_start
	_wait_for_pmcd
	_restore_auto_restart pmcd
	_service pmlogger start 2>&1 | _filter_pcp_start
	_wait_for_pmlogger
	_needclean=false
    fi
    $sudo rm -f $tmp.*
    exit $status
}

# real QA test starts here

# disable all pmloggers ...
$sudo cp $PCP_PMLOGGERCONTROL_PATH $tmp.control
$sudo mv $PCP_PMLOGGERCONTROL_PATH.d $tmp.control.d
cat <<End-of-File >$tmp.tmp
# dummy file created by qa/$seq on `date`
# the goal here is to have a controlled primary logger that does
# not make requests to pmcd!
\$version=1.1
LOCALHOSTNAME y n $LOGGING_DIR/LOCALHOSTNAME -c /dev/null
End-of-File
$sudo cp $tmp.tmp $PCP_PMLOGGERCONTROL_PATH

# I have no idea why this is required, but this test run
# after 040 sometimes produces garbled messages unless
# this is done!
if ! _service pmlogger stop >$tmp.out 2>$tmp.err; then _exit 1; fi
_wait_pmlogger_end || _exit 1
cat $tmp.out >>$seq_full
_filter_pcp_stop <$tmp.out
cat $tmp.err
if ! _service pmcd stop >$tmp.out 2>$tmp.err; then _exit 1; fi
_wait_pmcd_end || _exit 1
cat $tmp.out >>$seq_full
_filter_pcp_stop <$tmp.out
cat $tmp.err

# allow pmcd's socket teardown to complete
#
sleep 2

rm -f $tmp.out $tmp.err
_expect "connection refused"
pminfo -f sample.long.million 2>&1 | _filter

( _service pmcd restart; _service pmlogger restart ) >$tmp.one 2>&1
_wait_for_pmcd || _exit 1
_wait_for_pmlogger || _exit 1

_expect "one million retrieved OK from sample.long.million"
pminfo -f sample.long.million

sleep 3		# make sure pmlogger is not clobbered

pid=`_get_pids_by_name pmcd`
if [ -z "$pid" ]
then
    echo "Arrgh ... cannot find PID for pmcd!"
    ps $PCP_PS_ALL_FLAGS
    echo "=== pmcd.log ==="
    cat $PCP_LOG_DIR/pmcd/pmcd.log
    echo "=== pmcd.log.prev ==="
    cat $PCP_LOG_DIR/pmcd/pmcd.log.prev
    exit
fi
echo "pmcd pid=$pid" >>$seq_full
ps $PCP_PS_ALL_FLAGS | grep -E "PID|$pid" >>$seq_full

$sudo kill -STOP $pid

echo "after kill -STOP $pid" >>$seq_full
ps $PCP_PS_ALL_FLAGS | grep -E "PID|$pid" >>$seq_full

sleep 3		# make sure pmcd gets the SIGSTOP

# this will hang, and then see a timeout failure when PMCD is
# killed off
$sudo rm -f $tmp.tmp
PMCD_CONNECT_TIMEOUT=1000
export PMCD_CONNECT_TIMEOUT
pminfo -f sample.long.million >$tmp.tmp 2>&1 &

_expect "Forcing termination"
ps $PCP_PS_ALL_FLAGS | grep -E "PID|$pid" >>$seq_full
( $sudo $PCP_RC_DIR/pmcd restart; $sudo $PCP_RC_DIR/pmlogger restart ) >$tmp.two 2>&1
_wait_for_pmcd || _exit 1
_wait_for_pmlogger || _exit 1
wait

_filter_pcp_start <$tmp.one | _filter
_filter <$tmp.two
rm -f $tmp.out $tmp.err

_expect "Timeout waiting for a response from PMCD"
_filter <$tmp.tmp
rm -f $tmp.tmp

sleep 3		# don't ask, I don't understand either (kenj)

_expect "one million again"
pminfo -f sample.long.million

# all OK
status=0
exit