File: raidstorcli0.txt

package info (click to toggle)
phpsysinfo 3.4.4-1
  • links: PTS, VCS
  • area: main
  • in suites: forky, sid, trixie
  • size: 7,900 kB
  • sloc: javascript: 22,511; php: 20,651; xml: 18,293; sh: 196; python: 58; makefile: 12
file content (410 lines) | stat: -rw-r--r-- 11,520 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
Generating detailed summary of the adapter, it may take a while to complete.


Controller = 0
Status = Success
Description = None

Basics :
======
Controller = 0
Model = ServeRAID M5210
Serial Number = SV54341012
Current Controller Date/Time = 09/23/2016, 15:04:05
Current System Date/time = 09/23/2016, 15:04:05
SAS Address = 500605b00b3ee5e0
PCI Address = 00:01:00:00
Mfg Date = 10/28/15
Rework Date = 00/00/00
Revision No = 04D


Version :
=======
Firmware Package Build = 24.12.0-0024
Firmware Version = 4.620.00-6070
BIOS Version = 6.30.03.0_4.17.08.00_0x06130200
NVDATA Version = 3.1511.00-0009
Ctrl-R Version = 5.15-1002
Preboot CLI Version = 01.07-05:#%0000
Boot Block Version = 3.07.00.00-0003
Driver Name = megasas2.sys
Driver Version = 6.710.15.00


Bus :
===
Vendor ID = 0x1000
Device ID = 0x5D
SubVendor ID = 0x1014
SubDevice ID = 0x454
Host Interface = PCIE
Device Interface = SAS-12G
Bus Number = 1
Device Number = 0
Function Number = 0


Pending Images in Flash :
=======================
Image name = No pending images


Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 0
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
BIOS was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No


Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruct Rate = Yes
Patrol Read Rate = Yes
Alarm Control = No
Cluster Support = No
BBU = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
firmware and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd and Even Drive count in RAID1E = No
Support Security = Yes
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
support EKM = Yes
Snapshot Enabled = No
Support PFK = Yes
Support PI = Yes
Support LDPI Type1 = No
Support LDPI Type2 = No
Support LDPI Type3 = No
Support Ld BBM Info = No
Support Shield State = Yes
Block SSD Write Disk Cache Change = Yes
Support Suspend Resume BG ops = Yes
Support Emergency Spares = Yes
Support Set Link Speed = Yes
Support Boot Time PFK Change = Yes
Support JBOD = Yes
Disable Online PFK Change = Yes
Support Perf Tuning = Yes
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = Yes
Extended LD = Yes


Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = No
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = Yes


Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
I/O Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = No
Support FastPath = No
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = Yes
Support SSC WriteBack = No
Support SSC Association = No


Advanced Software Option part number :
========================

--------------------------------------------
Adv S/W Opt         Time Remaining    Mode
--------------------------------------------
MegaRAID SafeStore  Unlimited Secured
MegaRAID RAID5      Unlimited Secured
--------------------------------------------

Safe ID = XCR9FXJX6PQ866ND56BJ86DU5V7CQ8XG4NQAKDRZ

HwCfg :
=====
ChipRevision = C0
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = Missing
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 32MB
On Board Memory Size = 1024MB
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Absent
Current Size of CacheCade (GB) = 0
Current Size of firmware Cache (MB) = 651
ROC temperature(Degree Celcius) = 72


Policies :
========

Policies Table :
==============

------------------------------------------------
Policy                          Current Default
------------------------------------------------
Predictive Fail Poll Interval   300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion   50 us
Rebuild Rate                    30 %    30%
PR Rate                         30 %    30%
BGI Rate                        30 %    30%
Check Consistency Rate          30 %    30%
Reconstruction Rate             30 %    30%
Cache Flush Interval            0s
------------------------------------------------

Flush Time(Default) = 4s
Drive Coercion Mode = 1GB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore HotSpare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = On
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off


Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 2
Maximum number of direct attached drives to spin up in 1 min = 10
Delay Among Spinup Groups (sec) = 12
Allow Boot with Preserved Cache = Off


High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No


Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 256kB
Write Policy = WB
Read Policy = Adaptive
Cache When BBU Bad = Off
Cached I/O = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 1 GB
ZCR Config = Unknown
Max Chained Enclosures = 16
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = Yes
Zero Based Enclosure Enumeration = No
Disable Puncturing = Yes
EnableLDBBM = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = Yes
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving Option part number = Disabled
TTY Log In Flash = No
Auto Enhanced Import = Yes
BreakMirror RAID Support = Yes
Disable Join Mirror = No
Enable Shield State = Yes
Time taken to detect CME = 60 sec


Capabilities :
============
Supported Drives = SAS, SATA
Boot Volume Supported = NO
RAID Level Supported = RAID0, RAID1, RAID5, RAID00, RAID10, RAID50, 
PRL 11, PRL 11 with spanning, SRL 3 supported, 
PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Enable JBOD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Not Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 64
Max Number of VDs = 64
Max Parallel Commands = 928
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 128
Max Configurable CacheCade Size = 0
Min Strip Size = 64 KB
Max Strip Size = 1.0 MB


Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = 09/24/2016, 02:59:53
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 09/24/2016, 02:59:53
Battery learn Reoccurrence = 672 hrs
Next Battery Learn = 10/06/2016, 14:28:32
OEMID = IBM

Drive Groups = 1

TOPOLOGY :
========

--------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace
--------------------------------------------------------------------------
 0 -   -   -        -   RAID5 Optl  N    4.087 TB dsbl N  N   none N
 0 0   -   -        -   RAID5 Optl  N    4.087 TB dsbl N  N   none N
 0 0   0   252:5    7   DRIVE Onln  N  837.258 GB dsbl N  N   none -
 0 0   1   252:4    8   DRIVE Onln  N  837.258 GB dsbl N  N   none -
 0 0   2   252:1    10  DRIVE Onln  N  837.258 GB dsbl N  N   none -
 0 0   3   252:6    11  DRIVE Onln  N  837.258 GB dsbl N  N   none -
 0 0   4   252:2    12  DRIVE Onln  N  837.258 GB dsbl N  N   none -
 0 0   5   252:3    13  DRIVE Onln  N  837.258 GB dsbl N  N   none -
--------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present

Virtual Drives = 1

VD LIST :
=======

---------------------------------------------------------
DG/VD TYPE State Access Consist Cache sCC Size Name
---------------------------------------------------------
0/0 RAID5 Optl RW Yes RWBD - 4.087 TB
---------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|B=Blocked|Consist=Consistent|
R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 7

PD LIST :
=======

-------------------------------------------------------------------------
EID:Slt DID State DG        Size Intf Med SED PI SeSz Model           Sp
-------------------------------------------------------------------------
252:0     9 GHS    -  837.258 GB SAS  HDD N   N  512B ST900MM0168     U
252:1    10 Onln   0  837.258 GB SAS  HDD N   N  512B ST900MM0168     U
252:2    12 Onln   0  837.258 GB SAS  HDD N   N  512B AL14SEB090N     U
252:3    13 Onln   0  837.258 GB SAS  HDD N   N  512B AL14SEB090N     U
252:4     8 Onln   0  837.258 GB SAS  HDD N   N  512B AL14SEB090N     U
252:5     7 Onln   0  837.258 GB SAS  HDD N   N  512B AL14SEB090N     U
252:6    11 Onln   0  837.258 GB SAS  HDD N   N  512B AL14SEB090N     U
-------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded


Cachevault_Info :
===============

------------------------------------
Model  State   Temp Mode MfgDate
------------------------------------
CVPM02 Optimal 28C  -    2016/01/09
------------------------------------