1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534
|
Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.1324.0000.0000 June 1, 2020
Operating system = Windows Server 2016
Controller = 0
Status = Success
Description = None
Basics :
======
Controller = 0
Model = RAID 930-24i 4GB Flash
Serial Number = SXXXXXXX5
Current Controller Date/Time = 03/10/2022, 08:12:41
Current System Date/time = 03/10/2022, 08:12:43
SAS Address = 500062b1002dd100
PCI Address = 00:86:00:00
Mfg Date = 11/13/17
Rework Date = 00/00/00
Revision No = 26005
Version :
=======
Firmware Package Build = 50.0.1-0374
Firmware Version = 5.001.00-0805
CPLD Version = 05664-021
SBR Version = 260
Boot Block Version = 7.02.00.00-0015
Bios Version = 7.00.09.0_4.17.08.00_0x07001600
NVDATA Version = 4.1610.00-0093
Driver Name = megasas35.sys
Driver Version = 7.705.08.00
Bus :
===
Vendor Id = 0x1000
Device Id = 0x16
SubVendor Id = 0x1D49
SubDevice Id = 0x603
Host Interface = PCI-E
Device Interface = SAS-12G
Bus Number = 134
Device Number = 0
Function Number = 0
Domain ID = 0
Pending Images in Flash :
=======================
Image name = No pending images
Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 0
PD Firmware Download in progress = No
Support PD Firmware Download = Yes
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No
Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruct Rate = Yes
Patrol Read Rate = Yes
Alarm Control = No
Cluster Support = No
BBU = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = Yes
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = Yes
Snapshot Enabled = No
Support PFK = Yes
Support PI = Yes
Support LDPI Type1 = No
Support LDPI Type2 = No
Support LDPI Type3 = No
Support Ld BBM Info = No
Support Shield State = Yes
Block SSD Write Disk Cache Change = Yes
Support Suspend Resume BG ops = Yes
Support Emergency Spares = Yes
Support Set Link Speed = Yes
Support Boot Time PFK Change = Yes
Support JBOD = Yes
Disable Online PFK Change = Yes
Support Perf Tuning = Yes
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = Yes
Extended LD = Yes
Support Uneven span = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = Yes
Support Ext Enclosure = No
Support Sesmonitoring = Yes
Support SecurityonJBOD = Yes
Support ForceFlash = Yes
Support DisableImmediateIO = Yes
Support LargeIOSupport = No
Support DrvActivityLEDSetting = Yes
Support FlushWriteVerify = Yes
Support CPLDUpdate = Yes
Support ForceTo512e = Yes
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = Yes
Support IButton less = Yes
Support AES Encryption Algorithm = No
Support Encrypted MFC = Yes
Support Snapdump = No
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = No
Support Secure Boot = No
Support Debug Queue = Yes
Support Least Latency Mode = Yes
Support OnDemand Snapdump = No
Support Clear Snapdump = No
Support PHY current speed = No
Support Lane current speed = No
Support NVMe Width = No
Support Lane DeviceType = No
Support Extended Drive performance Monitoring = No
Enterprise Key management :
=========================
Capability = Supported
Boot Agent = Available
Configured = No
Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = No
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = Yes
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Support SSD Wear Gauge = No
Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = No
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = Yes
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = Yes
Support VD Cachebypass = Yes
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = No
Advanced Software Option :
========================
-----------------------------------------
Adv S/W Opt Time Remaining Mode
-----------------------------------------
MegaRAID FastPath Unlimited -
MegaRAID SafeStore Unlimited -
MegaRAID RAID6 Unlimited -
MegaRAID RAID5 Unlimited -
-----------------------------------------
Safe ID = EQ3WU1IHBBI8L3V6GDNIX997S9G36M1NXE7T9URZ
HwCfg :
=====
ChipRevision = B0
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = Missing
Serial Debugger = Present
NVRAM Size = 128KB
Flash Size = 16MB
On Board Memory Size = 4096MB
CacheVault Flash Size = 8.187 GB
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Absent
Upgradable CPLD = Present
Upgradable PSOC = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 3183
ROC temperature(Degree Celsius) = 69
Policies :
========
Policies Table :
==============
------------------------------------------------
Policy Current Default
------------------------------------------------
Predictive Fail Poll Interval 300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion 50 us
Rebuild Rate 30 % 30%
PR Rate 30 % 30%
BGI Rate 30 % 30%
Check Consistency Rate 30 % 30%
Reconstruction Rate 30 % 30%
Cache Flush Interval 4s
------------------------------------------------
Flush Time(Default) = 4s
Drive Coercion Mode = 1GB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = On
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off
Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 2
Maximum number of direct attached drives to spin up in 1 min = 60
Delay Among Spinup Groups (sec) = 2
Allow Boot with Preserved Cache = Off
High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No
Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 256 KB
Write Policy = WB
Read Policy = No Read Ahead
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 1 GB
ZCR Config = Unknown
Max Chained Enclosures = 3
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = Yes
Zero Based Enclosure Enumeration = No
Disable Puncturing = Yes
EnableLDBBM = No
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = Yes
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving option = Disabled
TTY Log In Flash = No
Auto Enhanced Import = Yes
BreakMirror RAID Support = single span R1
Disable Join Mirror = No
Enable Shield State = Yes
Time taken to detect CME = 60 sec
Capabilities :
============
Supported Drives = SAS, SATA
RAID Level Supported = RAID0, RAID1(2 or more drives), RAID5, RAID6, RAID00, RAID10(2 or more drives per span), RAID50, RAID60
Enable JBOD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Not Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 64
Max Number of VDs = 64
Max Parallel Commands = 4077
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 42
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Enable Snapdump = No
Enable SCSI Unmap = Yes
FDE Drive Mix Support = No
Min Strip Size = 64 KB
Max Strip Size = 1.000 MB
Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = 03/12/2022, 03:00:00
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 03/12/2022, 03:00:00
Battery learn Reoccurrence = 670 hrs
Next Battery Learn = 03/27/2022, 10:00:00
OEMID = Lenovo
Drive Groups = 2
TOPOLOGY :
========
------------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
------------------------------------------------------------------------------
0 - - - - RAID1 Optl N 893.137 GB dflt N N dflt N N
0 0 - - - RAID1 Optl N 893.137 GB dflt N N dflt N N
0 0 0 65:0 46 DRIVE Onln N 893.137 GB dflt N N dflt - N
0 0 1 65:1 47 DRIVE Onln N 893.137 GB dflt N N dflt - N
1 - - - - RAID10 Optl N 10.904 TB dsbl N N dflt N N
1 0 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 0 0 65:2 49 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 0 1 65:3 41 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 0 2 65:4 40 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 0 3 65:5 44 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 1 0 65:6 39 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 1 65:7 43 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 2 65:8 37 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 1 3 65:9 36 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 2 0 65:10 35 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 1 65:11 42 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 2 65:12 34 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 2 3 65:13 33 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 3 0 65:14 31 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 1 65:15 30 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 2 65:16 38 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 3 3 65:17 27 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 - - - RAID1 Optl N 2.180 TB dsbl N N dflt N N
1 4 0 65:18 28 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 1 65:19 26 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 2 65:20 25 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 4 3 65:21 32 DRIVE Onln N 1.089 TB dsbl N N dflt - N
1 - - 65:23 29 DRIVE DHS - 1.089 TB - - - - - N
------------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Optl=Optimal|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 2
VD LIST :
=======
-------------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-------------------------------------------------------------------
0/0 RAID1 Optl RW Yes RWBD - ON 893.137 GB OS
1/1 RAID10 Optl RW Yes RWBD - ON 10.904 TB Volume1
-------------------------------------------------------------------
VD=Virtual Drive| DG=Drive Group|Rec=Recovery
Cac=CacheCade|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|dflt=Default|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 24
PD LIST :
=======
-----------------------------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-----------------------------------------------------------------------------------------------------
65:0 46 Onln 0 893.137 GB SATA SSD N N 512B MTFDDAK960TDC-1AT1ZA 01PE307D7A09592LEN U -
65:1 47 Onln 0 893.137 GB SATA SSD N N 512B MTFDDAK960TDC-1AT1ZA 01PE307D7A09592LEN U -
65:2 49 Onln 1 1.089 TB SAS HDD N N 512B ST1200MM0009 U -
65:3 41 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:4 40 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:5 44 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:6 39 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:7 43 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:8 37 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:9 36 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:10 35 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:11 42 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:12 34 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:13 33 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:14 31 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:15 30 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:16 38 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:17 27 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:18 28 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:19 26 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:20 25 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:21 32 Onln 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
65:22 48 UGood - 1.089 TB SAS HDD N N 512B ST1200MM0009 U -
65:23 29 DHS 1 1.089 TB SAS HDD N N 512B AL15SEB120N U -
-----------------------------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Sntze=Sanitize|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=UGood Unsupported|UGShld=UGood shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|Rbld=Rebuild
Enclosures = 2
Enclosure LIST :
==============
-----------------------------------------------------------------------
EID State Slots PD PS Fans TSs Alms SIM Port# ProdID VendorSpecific
-----------------------------------------------------------------------
65 OK 24 24 0 0 0 0 0 SAS35x36R exp-0.3.2.0
134 OK 8 0 0 0 0 0 1 - SGPIO
-----------------------------------------------------------------------
EID=Enclosure Device ID |PD=Physical drive count |PS=Power Supply count|
TSs=Temperature sensor count |Alms=Alarm count |SIM=SIM Count ||ProdID=Product ID
Cachevault_Info :
===============
------------------------------------
Model State Temp Mode MfgDate
------------------------------------
CVPM02 Optimal 29C - 2018/04/05
------------------------------------
|