1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504
|
Generating detailed summary of the adapter, it may take a while to complete.
Controller = 0
Status = Success
Description = None
Basics :
======
Controller = 0
Model = LSI 2108 MegaRAID
Serial Number = FW-ABCDEFGHIJKLM
Current Controller Date/Time = 12/24/2022, 10:33:04
Current System Date/time = 12/24/2022, 10:33:22
SAS Address = 5003048014579200
PCI Address = 00:82:00:00
Mfg Date = 00/00/00
Rework Date = 00/00/00
Revision No =
Version :
=======
Firmware Package Build = 12.15.0-0239
Firmware Version = 2.130.403-4660
Bios Version = 3.30.02.2_4.16.08.00_0x06060A05
Preboot CLI Version = 04.04-020:#%00009
WebBIOS Version = 6.0-54-e_50-Rel
NVDATA Version = 2.09.03-0058
Boot Block Version = 2.02.00.00-0000
Bootloader Version = 09.250.01.219
Driver Name = megaraid_sas
Driver Version = 07.717.02.00-rc1
Bus :
===
Vendor Id = 0x1000
Device Id = 0x79
SubVendor Id = 0x15D9
SubDevice Id = 0x700
Host Interface = PCI-E
Device Interface = SAS-6G
Bus Number = 130
Device Number = 0
Function Number = 0
Pending Images in Flash :
=======================
Image name = No pending images
Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 44
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruct Rate = Yes
Patrol Read Rate = Yes
Alarm Control = Yes
Cluster Support = No
BBU = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = No
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = No
Snapshot Enabled = No
Support PFK = Yes
Support PI = No
Support Ld BBM Info = No
Support Shield State = No
Block SSD Write Disk Cache Change = No
Support Suspend Resume BG ops = No
Support Emergency Spares = Yes
Support Set Link Speed = No
Support Boot Time PFK Change = No
Support JBOD = No
Disable Online PFK Change = No
Support Perf Tuning = No
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = No
Extended LD = No
Boot Volume Supported = No
Support Uneven span = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = No
Support Ext Enclosure = No
Support Sesmonitoring = No
Support SecurityonJBOD = No
Support ForceFlash = No
Support DisableImmediateIO = Yes
Support LargeIOSupport = No
Support DrvActivityLEDSetting = Yes
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = No
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support SRIOV Options = No
Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = No
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = No
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = No
Support SSC WriteBack = No
Support SSC Association = Yes
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No
Advanced Software Option :
========================
-------------------------------------
Adv S/W Opt Time Remaining Mode
-------------------------------------
MegaRAID RAID6 Unlimited -
MegaRAID RAID5 Unlimited -
-------------------------------------
Safe ID = JJ17M5BUPUQ81RDKM9HGF7IMB81U6ME2RUI7432Z
HwCfg :
=====
ChipRevision = B4
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = On
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 8MB
On Board Memory Size = 512MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Absent
Temperature Sensor for Controller = Absent
Upgradable CPLD = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 346
Policies :
========
Policies Table :
==============
------------------------------------------------
Policy Current Default
------------------------------------------------
Predictive Fail Poll Interval 300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion 50 us
Rebuild Rate 30 % 30%
PR Rate 30 % 30%
BGI Rate 30 % 30%
Check Consistency Rate 30 % 30%
Reconstruction Rate 30 % 30%
Cache Flush Interval 4s
------------------------------------------------
Flush Time(Default) = 4s
Drive Coercion Mode = 1GB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore HotSpare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = Off
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off
Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = Yes
Enable PreBoot CLI = Yes
Enable BIOS = Yes
Max Drives to Spinup at One Time = 4
Maximum number of direct attached drives to spin up in 1 min = 120
Delay Among Spinup Groups (sec) = 2
Allow Boot with Preserved Cache = Off
High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No
Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WB
Read Policy = Adaptive
Cache When BBU Bad = On
Cached IO = On
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 1 GB
ZCR Config = Unknown
Max Chained Enclosures = 16
Direct PD Mapping = Yes
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = No
Zero Based Enclosure Enumeration = No
Disable Puncturing = No
EnableLDBBM = Yes
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving option = Enabled
TTY Log In Flash = No
Auto Enhanced Import = No
BreakMirror RAID Support = No
Disable Join Mirror = No
Enable Shield State = No
Time taken to detect CME = 60 sec
Capabilities :
============
Supported Drives = SAS, SATA
Boot Volume Supported = NO
RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50,
RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported,
PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Enable JBOD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Allowed
Mix of SAS/SATA of SSD type in VD = Allowed
Mix of SSD/HDD in VD = Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 16
Max Number of VDs = 64
Max Parallel Commands = 1008
Max SGE Count = 80
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 42
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Min Strip Size = 8 KB
Max Strip Size = 1.0 MB
Scheduled Tasks :
===============
Consistency Check Reoccurrence = 672 hrs
Next Consistency check launch = 12/24/2022, 04:00:00
Patrol Read Reoccurrence = 672 hrs
Next Patrol Read launch = 12/25/2022, 04:00:00
Battery learn Reoccurrence = 672 hrs
Next Battery Learn = 12/24/2022, 04:00:00
OEMID = LSI
Drive Groups = 1
TOPOLOGY :
========
----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
----------------------------------------------------------------------------
0 - - - - RAID5 Optl Y 10.913 TB dflt N N none N N
0 0 - - - RAID5 Optl Y 10.913 TB dflt N N none N N
0 0 0 252:0 0 DRIVE Onln N 2.727 TB dflt N N none - N
0 0 1 252:1 1 DRIVE Onln N 2.727 TB dflt N N none - N
0 0 2 252:2 2 DRIVE Onln N 2.727 TB dflt N N none - N
0 0 3 252:3 3 DRIVE Onln N 2.727 TB dflt N N none - N
0 0 4 252:4 4 DRIVE Onln N 2.727 TB dflt N N none - N
----------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 1
VD LIST :
=======
--------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
--------------------------------------------------------------
0/0 RAID5 Optl RW Yes RWBC - ON 10.913 TB
--------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 5
PD LIST :
=======
-----------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-----------------------------------------------------------------------------------
252:0 0 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:1 1 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:2 2 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:3 3 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:4 4 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
-----------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
BBU_Info :
========
-----------------------------------------------------------------------
Model State RetentionTime Temp Mode MfgDate Next Learn
-----------------------------------------------------------------------
iBBU08 Optimal 48 hours + 47C 1 2012/08/22 2022/13/24 04:00:00
-----------------------------------------------------------------------
Mode 1: 12+ Hrs retention with a transparent learn cycle
and best service life.
Controller = 0
Status = Success
Description = None
/c0/v0 :
======
--------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
--------------------------------------------------------------
0/0 RAID5 Optl RW Yes RWBC - ON 10.913 TB
--------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
PDs for VD 0 :
============
-----------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
-----------------------------------------------------------------------------------
252:0 0 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:1 1 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:2 2 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:3 3 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
252:4 4 Onln 0 2.727 TB SATA HDD N N 512B Hitachi HUA723030ALA641 U -
-----------------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
VD0 Properties :
==============
Strip Size = 64 KB
Number of Blocks = 23437492224
VD has Emulated PD = No
Span Depth = 1
Number of Drives Per Span = 5
Write Cache(initial setting) = WriteBack
Disk Cache Policy = Disk's Default
Encryption = None
Data Protection = None
Active Operations = Consistency Check (95%)
Exposed to OS = Yes
Creation Date = 29-04-2021
Creation Time = 10:53:28 AM
Emulation type = default
Is LD Ready for OS Requests = Yes
SCSI NAA Id = 6003048014579200281d4ca843bb0950
|