File: raidstorcli2.txt

package info (click to toggle)
phpsysinfo 3.4.4-1
  • links: PTS, VCS
  • area: main
  • in suites: forky, sid, trixie
  • size: 7,900 kB
  • sloc: javascript: 22,511; php: 20,651; xml: 18,293; sh: 196; python: 58; makefile: 12
file content (504 lines) | stat: -rw-r--r-- 15,165 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
Generating detailed summary of the adapter, it may take a while to complete.

Controller = 0
Status = Success
Description = None


Basics :
======
Controller = 0
Model = LSI 2108 MegaRAID
Serial Number = FW-ABCDEFGHIJKLM
Current Controller Date/Time = 12/24/2022, 10:33:04
Current System Date/time = 12/24/2022, 10:33:22
SAS Address = 5003048014579200
PCI Address = 00:82:00:00
Mfg Date = 00/00/00
Rework Date = 00/00/00
Revision No = 


Version :
=======
Firmware Package Build = 12.15.0-0239
Firmware Version = 2.130.403-4660
Bios Version = 3.30.02.2_4.16.08.00_0x06060A05
Preboot CLI Version = 04.04-020:#%00009
WebBIOS Version = 6.0-54-e_50-Rel
NVDATA Version = 2.09.03-0058
Boot Block Version = 2.02.00.00-0000
Bootloader Version = 09.250.01.219
Driver Name = megaraid_sas
Driver Version = 07.717.02.00-rc1


Bus :
===
Vendor Id = 0x1000
Device Id = 0x79
SubVendor Id = 0x15D9
SubDevice Id = 0x700
Host Interface = PCI-E
Device Interface = SAS-6G
Bus Number = 130
Device Number = 0
Function Number = 0


Pending Images in Flash :
=======================
Image name = No pending images


Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 44
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No


Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate  = Yes
Reconstruct Rate = Yes
Patrol Read Rate = Yes
Alarm Control = Yes
Cluster Support = No
BBU  = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = No
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = No
Snapshot Enabled = No
Support PFK = Yes
Support PI = No
Support Ld BBM Info = No
Support Shield State = No
Block SSD Write Disk Cache Change = No
Support Suspend Resume BG ops = No
Support Emergency Spares = Yes
Support Set Link Speed = No
Support Boot Time PFK Change = No
Support JBOD = No
Disable Online PFK Change = No
Support Perf Tuning = No
Support SSD PatrolRead = Yes
Real Time Scheduler = Yes
Support Reset Now = Yes
Support Emulated Drives = Yes
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = No
Extended LD = No
Boot Volume Supported = No
Support Uneven span  = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = No
Support Ext Enclosure = No
Support Sesmonitoring = No
Support SecurityonJBOD = No
Support ForceFlash = No
Support DisableImmediateIO = Yes
Support LargeIOSupport = No
Support DrvActivityLEDSetting = Yes
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = No
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support SRIOV Options = No


Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = No
Support Temperature = Yes
NCQ = No
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No


Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = No
Performance Metrics = Yes
Power Savings = No
Support Powersave Max With Cache = No
Support Breakmirror = No
Support SSC WriteBack = No
Support SSC Association = Yes
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No


Advanced Software Option :
========================

-------------------------------------
Adv S/W Opt     Time Remaining  Mode 
-------------------------------------
MegaRAID RAID6  Unlimited       -    
MegaRAID RAID5  Unlimited       -    
-------------------------------------

Safe ID =  JJ17M5BUPUQ81RDKM9HGF7IMB81U6ME2RUI7432Z

HwCfg :
=====
ChipRevision =  B4
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = On
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 8MB
On Board Memory Size = 512MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Absent
Temperature Sensor for Controller = Absent
Upgradable CPLD = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 346


Policies :
========

Policies Table :
==============

------------------------------------------------
Policy                          Current Default 
------------------------------------------------
Predictive Fail Poll Interval   300 sec         
Interrupt Throttle Active Count 16              
Interrupt Throttle Completion   50 us           
Rebuild Rate                    30 %    30%     
PR Rate                         30 %    30%     
BGI Rate                        30 %    30%     
Check Consistency Rate          30 %    30%     
Reconstruction Rate             30 %    30%     
Cache Flush Interval            4s              
------------------------------------------------

Flush Time(Default) = 4s
Drive Coercion Mode = 1GB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore HotSpare on Insertion = Off
Expose Enclosure Devices = On
Maintain PD Fail History = Off
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off


Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = No
Enable Web BIOS = Yes
Enable PreBoot CLI = Yes
Enable BIOS = Yes
Max Drives to Spinup at One Time = 4
Maximum number of direct attached drives to spin up in 1 min = 120
Delay Among Spinup Groups (sec) = 2
Allow Boot with Preserved Cache = Off


High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No


Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WB
Read Policy = Adaptive
Cache When BBU Bad = On
Cached IO = On
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 1 GB
ZCR Config = Unknown
Max Chained Enclosures = 16
Direct PD Mapping = Yes
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = Yes
Maintain PD Fail History = No
Zero Based Enclosure Enumeration = No
Disable Puncturing = No
EnableLDBBM = Yes
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = No
Power Saving option = Enabled
TTY Log In Flash = No
Auto Enhanced Import = No
BreakMirror RAID Support = No
Disable Join Mirror = No
Enable Shield State = No
Time taken to detect CME = 60 sec


Capabilities :
============
Supported Drives = SAS, SATA
Boot Volume Supported = NO
RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10, RAID50, 
RAID60, PRL 11, PRL 11 with spanning, SRL 3 supported, 
PRL11-RLQ0 DDF layout with no span, PRL11-RLQ0 DDF layout with span
Enable JBOD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Allowed
Mix of SAS/SATA of SSD type in VD = Allowed
Mix of SSD/HDD in VD = Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 16
Max Number of VDs = 64
Max Parallel Commands = 1008
Max SGE Count = 80
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 42
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Min Strip Size = 8 KB
Max Strip Size = 1.0 MB


Scheduled Tasks :
===============
Consistency Check Reoccurrence = 672 hrs
Next Consistency check launch = 12/24/2022, 04:00:00
Patrol Read Reoccurrence = 672 hrs
Next Patrol Read launch = 12/25/2022, 04:00:00
Battery learn Reoccurrence = 672 hrs
Next Battery Learn = 12/24/2022, 04:00:00
OEMID = LSI

Drive Groups = 1

TOPOLOGY :
========

----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type  State BT      Size PDC  PI SED DS3  FSpace TR 
----------------------------------------------------------------------------
 0 -   -   -        -   RAID5 Optl  Y  10.913 TB dflt N  N   none N      N  
 0 0   -   -        -   RAID5 Optl  Y  10.913 TB dflt N  N   none N      N  
 0 0   0   252:0    0   DRIVE Onln  N   2.727 TB dflt N  N   none -      N  
 0 0   1   252:1    1   DRIVE Onln  N   2.727 TB dflt N  N   none -      N  
 0 0   2   252:2    2   DRIVE Onln  N   2.727 TB dflt N  N   none -      N  
 0 0   3   252:3    3   DRIVE Onln  N   2.727 TB dflt N  N   none -      N  
 0 0   4   252:4    4   DRIVE Onln  N   2.727 TB dflt N  N   none -      N  
----------------------------------------------------------------------------

DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready

Virtual Drives = 1

VD LIST :
=======

--------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name 
--------------------------------------------------------------
0/0   RAID5 Optl  RW     Yes     RWBC  -   ON  10.913 TB      
--------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency

Physical Drives = 5

PD LIST :
=======

-----------------------------------------------------------------------------------
EID:Slt DID State DG     Size Intf Med SED PI SeSz Model                   Sp Type 
-----------------------------------------------------------------------------------
252:0     0 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:1     1 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:2     2 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:3     3 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:4     4 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
-----------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


BBU_Info :
========

-----------------------------------------------------------------------
Model  State   RetentionTime Temp Mode MfgDate    Next Learn           
-----------------------------------------------------------------------
iBBU08 Optimal 48 hours +    47C  1    2012/08/22 2022/13/24  04:00:00 
-----------------------------------------------------------------------

Mode 1: 12+ Hrs retention with a transparent learn cycle 
           and best service life.

Controller = 0
Status = Success
Description = None


/c0/v0 :
======

--------------------------------------------------------------
DG/VD TYPE  State Access Consist Cache Cac sCC      Size Name 
--------------------------------------------------------------
0/0   RAID5 Optl  RW     Yes     RWBC  -   ON  10.913 TB      
--------------------------------------------------------------

Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency


PDs for VD 0 :
============

-----------------------------------------------------------------------------------
EID:Slt DID State DG     Size Intf Med SED PI SeSz Model                   Sp Type 
-----------------------------------------------------------------------------------
252:0     0 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:1     1 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:2     2 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:3     3 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
252:4     4 Onln   0 2.727 TB SATA HDD N   N  512B Hitachi HUA723030ALA641 U  -    
-----------------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


VD0 Properties :
==============
Strip Size = 64 KB
Number of Blocks = 23437492224
VD has Emulated PD = No
Span Depth = 1
Number of Drives Per Span = 5
Write Cache(initial setting) = WriteBack
Disk Cache Policy = Disk's Default
Encryption = None
Data Protection = None
Active Operations = Consistency Check (95%)
Exposed to OS = Yes
Creation Date = 29-04-2021
Creation Time = 10:53:28 AM
Emulation type = default
Is LD Ready for OS Requests = Yes
SCSI NAA Id = 6003048014579200281d4ca843bb0950