1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798 799 800 801 802 803 804 805 806 807 808 809 810
|
from __future__ import annotations
import logging
from typing import Tuple
from .exceptions import RequestFailedException, RequestRejectedException
from .inverter import Inverter
from .inverter import OperationMode
from .inverter import SensorKind as Kind
from .modbus import ILLEGAL_DATA_ADDRESS
from .model import is_2_battery, is_4_mppt, is_745_platform, is_single_phase
from .protocol import ProtocolCommand
from .sensor import *
logger = logging.getLogger(__name__)
class ET(Inverter):
"""Class representing inverter of ET/EH/BT/BH or GE's GEH families AKA platform 205 or 745"""
# Modbus registers from offset 0x891c (35100), count 0x7d (125)
__all_sensors: Tuple[Sensor, ...] = (
Timestamp("timestamp", 35100, "Timestamp"),
Voltage("vpv1", 35103, "PV1 Voltage", Kind.PV),
Current("ipv1", 35104, "PV1 Current", Kind.PV),
Power4("ppv1", 35105, "PV1 Power", Kind.PV),
Voltage("vpv2", 35107, "PV2 Voltage", Kind.PV),
Current("ipv2", 35108, "PV2 Current", Kind.PV),
Power4("ppv2", 35109, "PV2 Power", Kind.PV),
Voltage("vpv3", 35111, "PV3 Voltage", Kind.PV),
Current("ipv3", 35112, "PV3 Current", Kind.PV),
Power4("ppv3", 35113, "PV3 Power", Kind.PV),
Voltage("vpv4", 35115, "PV4 Voltage", Kind.PV),
Current("ipv4", 35116, "PV4 Current", Kind.PV),
Power4("ppv4", 35117, "PV4 Power", Kind.PV),
# ppv1 + ppv2 + ppv3 + ppv4
Calculated("ppv",
lambda data:
max(0, read_bytes4(data, 35105, 0)) +
max(0, read_bytes4(data, 35109, 0)) +
max(0, read_bytes4(data, 35113, 0)) +
max(0, read_bytes4(data, 35117, 0)),
"PV Power", "W", Kind.PV),
ByteH("pv4_mode", 35119, "PV4 Mode code", "", Kind.PV),
EnumH("pv4_mode_label", 35119, PV_MODES, "PV4 Mode", Kind.PV),
ByteL("pv3_mode", 35119, "PV3 Mode code", "", Kind.PV),
EnumL("pv3_mode_label", 35119, PV_MODES, "PV3 Mode", Kind.PV),
ByteH("pv2_mode", 35120, "PV2 Mode code", "", Kind.PV),
EnumH("pv2_mode_label", 35120, PV_MODES, "PV2 Mode", Kind.PV),
ByteL("pv1_mode", 35120, "PV1 Mode code", "", Kind.PV),
EnumL("pv1_mode_label", 35120, PV_MODES, "PV1 Mode", Kind.PV),
Voltage("vgrid", 35121, "On-grid L1 Voltage", Kind.AC),
Current("igrid", 35122, "On-grid L1 Current", Kind.AC),
Frequency("fgrid", 35123, "On-grid L1 Frequency", Kind.AC),
# 35124 reserved
PowerS("pgrid", 35125, "On-grid L1 Power", Kind.AC),
Voltage("vgrid2", 35126, "On-grid L2 Voltage", Kind.AC),
Current("igrid2", 35127, "On-grid L2 Current", Kind.AC),
Frequency("fgrid2", 35128, "On-grid L2 Frequency", Kind.AC),
# 35129 reserved
PowerS("pgrid2", 35130, "On-grid L2 Power", Kind.AC),
Voltage("vgrid3", 35131, "On-grid L3 Voltage", Kind.AC),
Current("igrid3", 35132, "On-grid L3 Current", Kind.AC),
Frequency("fgrid3", 35133, "On-grid L3 Frequency", Kind.AC),
# 35134 reserved
PowerS("pgrid3", 35135, "On-grid L3 Power", Kind.AC),
Integer("grid_mode", 35136, "Grid Mode code", "", Kind.PV),
Enum2("grid_mode_label", 35136, GRID_MODES, "Grid Mode", Kind.PV),
# 35137 reserved
PowerS("total_inverter_power", 35138, "Total Power", Kind.AC),
# 35139 reserved
PowerS("active_power", 35140, "Active Power", Kind.GRID),
Calculated("grid_in_out",
lambda data: read_grid_mode(data, 35140),
"On-grid Mode code", "", Kind.GRID),
EnumCalculated("grid_in_out_label",
lambda data: read_grid_mode(data, 35140), GRID_IN_OUT_MODES,
"On-grid Mode", Kind.GRID),
# 35141 reserved
Reactive("reactive_power", 35142, "Reactive Power", Kind.GRID),
# 35143 reserved
Apparent("apparent_power", 35144, "Apparent Power", Kind.GRID),
Voltage("backup_v1", 35145, "Back-up L1 Voltage", Kind.UPS),
Current("backup_i1", 35146, "Back-up L1 Current", Kind.UPS),
Frequency("backup_f1", 35147, "Back-up L1 Frequency", Kind.UPS),
Integer("load_mode1", 35148, "Load Mode L1"),
# 35149 reserved
PowerS("backup_p1", 35150, "Back-up L1 Power", Kind.UPS),
Voltage("backup_v2", 35151, "Back-up L2 Voltage", Kind.UPS),
Current("backup_i2", 35152, "Back-up L2 Current", Kind.UPS),
Frequency("backup_f2", 35153, "Back-up L2 Frequency", Kind.UPS),
Integer("load_mode2", 35154, "Load Mode L2"),
# 35155 reserved
PowerS("backup_p2", 35156, "Back-up L2 Power", Kind.UPS),
Voltage("backup_v3", 35157, "Back-up L3 Voltage", Kind.UPS),
Current("backup_i3", 35158, "Back-up L3 Current", Kind.UPS),
Frequency("backup_f3", 35159, "Back-up L3 Frequency", Kind.UPS),
Integer("load_mode3", 35160, "Load Mode L3"),
# 35161 reserved
PowerS("backup_p3", 35162, "Back-up L3 Power", Kind.UPS),
# 35163 reserved
PowerS("load_p1", 35164, "Load L1", Kind.AC),
# 35165 reserved
PowerS("load_p2", 35166, "Load L2", Kind.AC),
# 35167 reserved
PowerS("load_p3", 35168, "Load L3", Kind.AC),
# 35169 reserved
PowerS("backup_ptotal", 35170, "Back-up Load", Kind.UPS),
# 35171 reserved
PowerS("load_ptotal", 35172, "Load", Kind.AC),
Integer("ups_load", 35173, "Ups Load", "%", Kind.UPS),
Temp("temperature_air", 35174, "Inverter Temperature (Air)", Kind.AC),
Temp("temperature_module", 35175, "Inverter Temperature (Module)"),
Temp("temperature", 35176, "Inverter Temperature (Radiator)", Kind.AC),
Integer("function_bit", 35177, "Function Bit"),
Voltage("bus_voltage", 35178, "Bus Voltage", None),
Voltage("nbus_voltage", 35179, "NBus Voltage", None),
Voltage("vbattery1", 35180, "Battery Voltage", Kind.BAT),
CurrentS("ibattery1", 35181, "Battery Current", Kind.BAT),
Power4S("pbattery1", 35182, "Battery Power", Kind.BAT),
Integer("battery_mode", 35184, "Battery Mode code", "", Kind.BAT),
Enum2("battery_mode_label", 35184, BATTERY_MODES, "Battery Mode", Kind.BAT),
Integer("warning_code", 35185, "Warning code"),
Integer("safety_country", 35186, "Safety Country code", "", Kind.AC),
Enum2("safety_country_label", 35186, SAFETY_COUNTRIES, "Safety Country", Kind.AC),
Integer("work_mode", 35187, "Work Mode code"),
Enum2("work_mode_label", 35187, WORK_MODES_ET, "Work Mode"),
Integer("operation_mode", 35188, "Operation Mode code"),
Long("error_codes", 35189, "Error Codes"),
EnumBitmap4("errors", 35189, ERROR_CODES, "Errors"),
Energy4("e_total", 35191, "Total PV Generation", Kind.PV),
Energy4("e_day", 35193, "Today's PV Generation", Kind.PV),
Energy4("e_total_exp", 35195, "Total Energy (export)", Kind.AC),
Long("h_total", 35197, "Hours Total", "h", Kind.PV),
Energy("e_day_exp", 35199, "Today Energy (export)", Kind.AC),
Energy4("e_total_imp", 35200, "Total Energy (import)", Kind.AC),
Energy("e_day_imp", 35202, "Today Energy (import)", Kind.AC),
Energy4("e_load_total", 35203, "Total Load", Kind.AC),
Energy("e_load_day", 35205, "Today Load", Kind.AC),
Energy4("e_bat_charge_total", 35206, "Total Battery Charge", Kind.BAT),
Energy("e_bat_charge_day", 35208, "Today Battery Charge", Kind.BAT),
Energy4("e_bat_discharge_total", 35209, "Total Battery Discharge", Kind.BAT),
Energy("e_bat_discharge_day", 35211, "Today Battery Discharge", Kind.BAT),
Long("diagnose_result", 35220, "Diag Status Code"),
EnumBitmap4("diagnose_result_label", 35220, DIAG_STATUS_CODES, "Diag Status"),
# ppv1 + ppv2 + ppv3 + ppv4 + pbattery1 - active_power
Calculated("house_consumption",
lambda data:
read_bytes4(data, 35105, 0) +
read_bytes4(data, 35109, 0) +
read_bytes4(data, 35113, 0) +
read_bytes4(data, 35117, 0) +
read_bytes4_signed(data, 35182) -
read_bytes2_signed(data, 35140),
"House Consumption", "W", Kind.AC),
# Power4S("pbattery2", 35264, "Battery2 Power", Kind.BAT),
# Integer("battery2_mode", 35266, "Battery2 Mode code", "", Kind.BAT),
# Enum2("battery2_mode_label", 35184, BATTERY_MODES, "Battery2 Mode", Kind.BAT),
)
# Modbus registers from offset 0x9088 (37000)
__all_sensors_battery: Tuple[Sensor, ...] = (
Integer("battery_bms", 37000, "Battery BMS", "", Kind.BAT),
Integer("battery_index", 37001, "Battery Index", "", Kind.BAT),
Integer("battery_status", 37002, "Battery Status", "", Kind.BAT),
Temp("battery_temperature", 37003, "Battery Temperature", Kind.BAT),
Integer("battery_charge_limit", 37004, "Battery Charge Limit", "A", Kind.BAT),
Integer("battery_discharge_limit", 37005, "Battery Discharge Limit", "A", Kind.BAT),
Integer("battery_error_l", 37006, "Battery Error L", "", Kind.BAT),
Integer("battery_soc", 37007, "Battery State of Charge", "%", Kind.BAT),
Integer("battery_soh", 37008, "Battery State of Health", "%", Kind.BAT),
Integer("battery_modules", 37009, "Battery Modules", "", Kind.BAT),
Integer("battery_warning_l", 37010, "Battery Warning L", "", Kind.BAT),
Integer("battery_protocol", 37011, "Battery Protocol", "", Kind.BAT),
Integer("battery_error_h", 37012, "Battery Error H", "", Kind.BAT),
EnumBitmap22("battery_error", 37012, 37006, BMS_ALARM_CODES, "Battery Error", Kind.BAT),
Integer("battery_warning_h", 37013, "Battery Warning H", "", Kind.BAT),
EnumBitmap22("battery_warning", 37013, 37010, BMS_WARNING_CODES, "Battery Warning", Kind.BAT),
Integer("battery_sw_version", 37014, "Battery Software Version", "", Kind.BAT),
Integer("battery_hw_version", 37015, "Battery Hardware Version", "", Kind.BAT),
Integer("battery_max_cell_temp_id", 37016, "Battery Max Cell Temperature ID", "", Kind.BAT),
Integer("battery_min_cell_temp_id", 37017, "Battery Min Cell Temperature ID", "", Kind.BAT),
Integer("battery_max_cell_voltage_id", 37018, "Battery Max Cell Voltage ID", "", Kind.BAT),
Integer("battery_min_cell_voltage_id", 37019, "Battery Min Cell Voltage ID", "", Kind.BAT),
Temp("battery_max_cell_temp", 37020, "Battery Max Cell Temperature", Kind.BAT),
Temp("battery_min_cell_temp", 37021, "Battery Min Cell Temperature", Kind.BAT),
CellVoltage("battery_max_cell_voltage", 37022, "Battery Max Cell Voltage", Kind.BAT),
CellVoltage("battery_min_cell_voltage", 37023, "Battery Min Cell Voltage", Kind.BAT),
# Energy4("battery_total_charge", 37056, "Total Battery 1 Charge", Kind.BAT),
# Energy4("battery_total_discharge", 37058, "Total Battery 1 Discharge", Kind.BAT),
# String8("battery_sn", 37060, "Battery S/N", Kind.BAT),
)
# Modbus registers from offset 0x9858 (39000)
__all_sensors_battery2: Tuple[Sensor, ...] = (
Integer("battery2_status", 39000, "Battery 2 Status", "", Kind.BAT),
Temp("battery2_temperature", 39001, "Battery 2 Temperature", Kind.BAT),
Integer("battery2_charge_limit", 39002, "Battery 2 Charge Limit", "A", Kind.BAT),
Integer("battery2_discharge_limit", 39003, "Battery 2 Discharge Limit", "A", Kind.BAT),
Integer("battery2_error_l", 39004, "Battery 2 rror L", "", Kind.BAT),
Integer("battery2_soc", 39005, "Battery 2 State of Charge", "%", Kind.BAT),
Integer("battery2_soh", 39006, "Battery 2 State of Health", "%", Kind.BAT),
Integer("battery2_modules", 39007, "Battery 2 Modules", "", Kind.BAT),
Integer("battery2_warning_l", 39008, "Battery 2 Warning L", "", Kind.BAT),
Integer("battery2_protocol", 39009, "Battery 2 Protocol", "", Kind.BAT),
Integer("battery2_error_h", 39010, "Battery 2 Error H", "", Kind.BAT),
EnumBitmap22("battery2_error", 39010, 39004, BMS_ALARM_CODES, "Battery 2 Error", Kind.BAT),
Integer("battery2_warning_h", 39011, "Battery 2 Warning H", "", Kind.BAT),
EnumBitmap22("battery2_warning", 39011, 39008, BMS_WARNING_CODES, "Battery 2 Warning", Kind.BAT),
Integer("battery2_sw_version", 39012, "Battery 2 Software Version", "", Kind.BAT),
Integer("battery2_hw_version", 39013, "Battery 2 Hardware Version", "", Kind.BAT),
Integer("battery2_max_cell_temp_id", 39014, "Battery 2 Max Cell Temperature ID", "", Kind.BAT),
Integer("battery2_min_cell_temp_id", 39015, "Battery 2 Min Cell Temperature ID", "", Kind.BAT),
Integer("battery2_max_cell_voltage_id", 39016, "Battery 2 Max Cell Voltage ID", "", Kind.BAT),
Integer("battery2_min_cell_voltage_id", 39017, "Battery 2 Min Cell Voltage ID", "", Kind.BAT),
Temp("battery2_max_cell_temp", 39018, "Battery 2 Max Cell Temperature", Kind.BAT),
Temp("battery2_min_cell_temp", 39019, "Battery 2 Min Cell Temperature", Kind.BAT),
CellVoltage("battery2_max_cell_voltage", 39020, "Battery 2 Max Cell Voltage", Kind.BAT),
CellVoltage("battery2_min_cell_voltage", 39021, "Battery 2 Min Cell Voltage", Kind.BAT),
# Energy4("battery2_total_charge", 39054, "Total Battery 2 Charge", Kind.BAT),
# Energy4("battery2_total_discharge", 39056, "Total Battery 2 Discharge", Kind.BAT),
# String8("battery2_sn", 39058, "Battery 2 S/N", Kind.BAT),
)
# Inverter's meter data
# Modbus registers from offset 0x8ca0 (36000)
__all_sensors_meter: Tuple[Sensor, ...] = (
Integer("commode", 36000, "Commode"),
Integer("rssi", 36001, "RSSI"),
Integer("manufacture_code", 36002, "Manufacture Code"),
Integer("meter_test_status", 36003, "Meter Test Status"), # 1: correct,2: reverse,3: incorrect,0: not checked
Integer("meter_comm_status", 36004, "Meter Communication Status"), # 1 OK, 0 NotOK
PowerS("active_power1", 36005, "Active Power L1", Kind.GRID),
PowerS("active_power2", 36006, "Active Power L2", Kind.GRID),
PowerS("active_power3", 36007, "Active Power L3", Kind.GRID),
PowerS("active_power_total", 36008, "Active Power Total", Kind.GRID),
Reactive("reactive_power_total", 36009, "Reactive Power Total", Kind.GRID),
Decimal("meter_power_factor1", 36010, 1000, "Meter Power Factor L1", "", Kind.GRID),
Decimal("meter_power_factor2", 36011, 1000, "Meter Power Factor L2", "", Kind.GRID),
Decimal("meter_power_factor3", 36012, 1000, "Meter Power Factor L3", "", Kind.GRID),
Decimal("meter_power_factor", 36013, 1000, "Meter Power Factor", "", Kind.GRID),
Frequency("meter_freq", 36014, "Meter Frequency", Kind.GRID),
Float("meter_e_total_exp", 36015, 1000, "Meter Total Energy (export)", "kWh", Kind.GRID),
Float("meter_e_total_imp", 36017, 1000, "Meter Total Energy (import)", "kWh", Kind.GRID),
Power4S("meter_active_power1", 36019, "Meter Active Power L1", Kind.GRID),
Power4S("meter_active_power2", 36021, "Meter Active Power L2", Kind.GRID),
Power4S("meter_active_power3", 36023, "Meter Active Power L3", Kind.GRID),
Power4S("meter_active_power_total", 36025, "Meter Active Power Total", Kind.GRID),
Reactive4("meter_reactive_power1", 36027, "Meter Reactive Power L1", Kind.GRID),
Reactive4("meter_reactive_power2", 36029, "Meter Reactive Power L2", Kind.GRID),
Reactive4("meter_reactive_power3", 36031, "Meter Reactive Power L2", Kind.GRID),
Reactive4("meter_reactive_power_total", 36033, "Meter Reactive Power Total", Kind.GRID),
Apparent4("meter_apparent_power1", 36035, "Meter Apparent Power L1", Kind.GRID),
Apparent4("meter_apparent_power2", 36037, "Meter Apparent Power L2", Kind.GRID),
Apparent4("meter_apparent_power3", 36039, "Meter Apparent Power L3", Kind.GRID),
Apparent4("meter_apparent_power_total", 36041, "Meter Apparent Power Total", Kind.GRID),
Integer("meter_type", 36043, "Meter Type", "", Kind.GRID), # (0: Single phase, 1: 3P3W, 2: 3P4W, 3: HomeKit)
Integer("meter_sw_version", 36044, "Meter Software Version", "", Kind.GRID),
# Sensors added in some ARM fw update (or platform 745/753), read when flag _has_meter_extended is on
Power4S("meter2_active_power", 36045, "Meter 2 Active Power", Kind.GRID),
Float("meter2_e_total_exp", 36047, 1000, "Meter 2 Total Energy (export)", "kWh", Kind.GRID),
Float("meter2_e_total_imp", 36049, 1000, "Meter 2 Total Energy (import)", "kWh", Kind.GRID),
Integer("meter2_comm_status", 36051, "Meter 2 Communication Status"),
Voltage("meter_voltage1", 36052, "Meter L1 Voltage", Kind.GRID),
Voltage("meter_voltage2", 36053, "Meter L2 Voltage", Kind.GRID),
Voltage("meter_voltage3", 36054, "Meter L3 Voltage", Kind.GRID),
Current("meter_current1", 36055, "Meter L1 Current", Kind.GRID),
Current("meter_current2", 36056, "Meter L2 Current", Kind.GRID),
Current("meter_current3", 36057, "Meter L3 Current", Kind.GRID),
Energy8("meter_e_total_exp1", 36092, "Meter Total Energy (export) L1", Kind.GRID),
Energy8("meter_e_total_exp2", 36096, "Meter Total Energy (export) L2", Kind.GRID),
Energy8("meter_e_total_exp3", 36100, "Meter Total Energy (export) L3", Kind.GRID),
Energy8("meter_e_total_exp", 36104, "Meter Total Energy (export)", Kind.GRID),
Energy8("meter_e_total_imp1", 36108, "Meter Total Energy (import) L1", Kind.GRID),
Energy8("meter_e_total_imp2", 36112, "Meter Total Energy (import) L2", Kind.GRID),
Energy8("meter_e_total_imp3", 36116, "Meter Total Energy (import) L3", Kind.GRID),
Energy8("meter_e_total_imp", 36120, "Meter Total Energy (import)", Kind.GRID),
)
# Inverter's MPPT data
# Modbus registers from offset 0x89e5 (35301)
__all_sensors_mppt: Tuple[Sensor, ...] = (
Power4("ppv_total", 35301, "PV Power Total", Kind.PV),
Integer("pv_channel", 35303, "PV Channel", "", Kind.PV),
Voltage("vpv5", 35304, "PV5 Voltage", Kind.PV),
Current("ipv5", 35305, "PV5 Current", Kind.PV),
Voltage("vpv6", 35306, "PV6 Voltage", Kind.PV),
Current("ipv6", 35307, "PV6 Current", Kind.PV),
Voltage("vpv7", 35308, "PV7 Voltage", Kind.PV),
Current("ipv7", 35309, "PV7 Current", Kind.PV),
Voltage("vpv8", 35310, "PV8 Voltage", Kind.PV),
Current("ipv8", 35311, "PV8 Current", Kind.PV),
Voltage("vpv9", 35312, "PV9 Voltage", Kind.PV),
Current("ipv9", 35313, "PV9 Current", Kind.PV),
Voltage("vpv10", 35314, "PV10 Voltage", Kind.PV),
Current("ipv10", 35315, "PV10 Current", Kind.PV),
Voltage("vpv11", 35316, "PV11 Voltage", Kind.PV),
Current("ipv11", 35317, "PV11 Current", Kind.PV),
Voltage("vpv12", 35318, "PV12 Voltage", Kind.PV),
Current("ipv12", 35319, "PV12 Current", Kind.PV),
Voltage("vpv13", 35320, "PV13 Voltage", Kind.PV),
Current("ipv13", 35321, "PV13 Current", Kind.PV),
Voltage("vpv14", 35322, "PV14 Voltage", Kind.PV),
Current("ipv14", 35323, "PV14 Current", Kind.PV),
Voltage("vpv15", 35324, "PV15 Voltage", Kind.PV),
Current("ipv15", 35325, "PV15 Current", Kind.PV),
Voltage("vpv16", 35326, "PV16 Voltage", Kind.PV),
Current("ipv16", 35327, "PV16 Current", Kind.PV),
# 35328 Warning Message
# 35330 Grid10minAvgVoltR
# 35331 Grid10minAvgVoltS
# 35332 Grid10minAvgVoltT
# 35333 Error Message Extend
# 35335 Warning Message Extend
Power("pmppt1", 35337, "MPPT1 Power", Kind.PV),
Power("pmppt2", 35338, "MPPT2 Power", Kind.PV),
Power("pmppt3", 35339, "MPPT3 Power", Kind.PV),
Power("pmppt4", 35340, "MPPT4 Power", Kind.PV),
Power("pmppt5", 35341, "MPPT5 Power", Kind.PV),
Power("pmppt6", 35342, "MPPT6 Power", Kind.PV),
Power("pmppt7", 35343, "MPPT7 Power", Kind.PV),
Power("pmppt8", 35344, "MPPT8 Power", Kind.PV),
Current("imppt1", 35345, "MPPT1 Current", Kind.PV),
Current("imppt2", 35346, "MPPT2 Current", Kind.PV),
Current("imppt3", 35347, "MPPT3 Current", Kind.PV),
Current("imppt4", 35348, "MPPT4 Current", Kind.PV),
Current("imppt5", 35349, "MPPT5 Current", Kind.PV),
Current("imppt6", 35350, "MPPT6 Current", Kind.PV),
Current("imppt7", 35351, "MPPT7 Current", Kind.PV),
Current("imppt8", 35352, "MPPT8 Current", Kind.PV),
Reactive4("reactive_power1", 35353, "Reactive Power L1", Kind.GRID),
Reactive4("reactive_power2", 35355, "Reactive Power L2", Kind.GRID),
Reactive4("reactive_power3", 35357, "Reactive Power L3", Kind.GRID),
Apparent4("apparent_power1", 35359, "Apparent Power L1", Kind.GRID),
Apparent4("apparent_power2", 35361, "Apparent Power L2", Kind.GRID),
Apparent4("apparent_power3", 35363, "Apparent Power L3", Kind.GRID),
)
# Modbus registers of inverter settings, offsets are modbus register addresses
__all_settings: Tuple[Sensor, ...] = (
Integer("comm_address", 45127, "Communication Address", ""),
Long("modbus_baud_rate", 45132, "Modbus Baud rate", ""),
Timestamp("time", 45200, "Inverter time"),
Integer("sensitivity_check", 45246, "Sensitivity Check Mode", "", Kind.AC),
Integer("cold_start", 45248, "Cold Start", "", Kind.AC),
Integer("shadow_scan", 45251, "Shadow Scan", "", Kind.PV),
Integer("backup_supply", 45252, "Backup Supply", "", Kind.UPS),
Integer("unbalanced_output", 45264, "Unbalanced Output", "", Kind.AC),
Integer("pen_relay", 45288, "PE-N Relay", "", Kind.AC),
Integer("battery_capacity", 45350, "Battery Capacity", "Ah", Kind.BAT),
Integer("battery_modules", 45351, "Battery Modules", "", Kind.BAT),
Voltage("battery_charge_voltage", 45352, "Battery Charge Voltage", Kind.BAT),
Current("battery_charge_current", 45353, "Battery Charge Current", Kind.BAT),
Voltage("battery_discharge_voltage", 45354, "Battery Discharge Voltage", Kind.BAT),
Current("battery_discharge_current", 45355, "Battery Discharge Current", Kind.BAT),
Integer("battery_discharge_depth", 45356, "Battery Discharge Depth", "%", Kind.BAT),
Voltage("battery_discharge_voltage_offline", 45357, "Battery Discharge Voltage (off-line)", Kind.BAT),
Integer("battery_discharge_depth_offline", 45358, "Battery Discharge Depth (off-line)", "%", Kind.BAT),
Decimal("power_factor", 45482, 100, "Power Factor"),
Integer("work_mode", 47000, "Work Mode", "", Kind.AC),
Integer("dred", 47010, "DRED/Remote Shutdown", "", Kind.AC),
Integer("meter_target_power_offset", 47120, "Meter Target Power Offset", "W", Kind.AC),
Integer("battery_soc_protection", 47500, "Battery SoC Protection", "", Kind.BAT),
Integer("grid_export", 47509, "Grid Export Enabled", "", Kind.GRID),
Integer("grid_export_limit", 47510, "Grid Export Limit", "W", Kind.GRID),
Integer("battery_protocol_code", 47514, "Battery Protocol Code", "", Kind.BAT),
EcoModeV1("eco_mode_1", 47515, "Eco Mode Group 1"),
ByteH("eco_mode_1_switch", 47518, "Eco Mode Group 1 Switch"),
EcoModeV1("eco_mode_2", 47519, "Eco Mode Group 2"),
ByteH("eco_mode_2_switch", 47522, "Eco Mode Group 2 Switch"),
EcoModeV1("eco_mode_3", 47523, "Eco Mode Group 3"),
ByteH("eco_mode_3_switch", 47526, "Eco Mode Group 3 Switch"),
EcoModeV1("eco_mode_4", 47527, "Eco Mode Group 4"),
ByteH("eco_mode_4_switch", 47530, "Eco Mode Group 4 Switch"),
# Direct BMS communication for EMS Control
Integer("bms_version", 47900, "BMS Version"),
Integer("bms_bat_modules", 47901, "BMS Battery Modules"),
# Real time read from BMS
Voltage("bms_bat_charge_v_max", 47902, "BMS Battery Charge Voltage (max)", Kind.BMS),
Current("bms_bat_charge_i_max", 47903, "BMS Battery Charge Current (max)", Kind.BMS),
Voltage("bms_bat_discharge_v_min", 47904, "BMS min. Battery Discharge Voltage (min)", Kind.BMS),
Current("bms_bat_discharge_i_max", 47905, "BMS max. Battery Discharge Current (max)", Kind.BMS),
Voltage("bms_bat_voltage", 47906, "BMS Battery Voltage", Kind.BMS),
Current("bms_bat_current", 47907, "BMS Battery Current", Kind.BMS),
#
Integer("bms_bat_soc", 47908, "BMS Battery State of Charge", "%", Kind.BMS),
Integer("bms_bat_soh", 47909, "BMS Battery State of Health", "%", Kind.BMS),
Temp("bms_bat_temperature", 47910, "BMS Battery Temperature", Kind.BMS),
Long("bms_bat_warning-code", 47911, "BMS Battery Warning Code"),
# Reserved
Long("bms_bat_alarm-code", 47913, "BMS Battery Alarm Code"),
Integer("bms_status", 47915, "BMS Status"),
Integer("bms_comm_loss_disable", 47916, "BMS Communication Loss Disable"),
# RW settings of BMS voltage rate
Integer("bms_battery_string_rate_v", 47917, "BMS Battery String Rate Voltage"),
# Direct BMS communication for EMS Control
Integer("bms2_version", 47918, "BMS2 Version"),
Integer("bms2_bat_modules", 47919, "BMS2 Battery Modules"),
# Real time read from BMS
Voltage("bms2_bat_charge_v_max", 47920, "BMS2 Battery Charge Voltage (max)", Kind.BMS),
Current("bms2_bat_charge_i_max", 47921, "BMS2 Battery Charge Current (max)", Kind.BMS),
Voltage("bms2_bat_discharge_v_min", 47922, "BMS2 min. Battery Discharge Voltage (min)", Kind.BMS),
Current("bms2_bat_discharge_i_max", 47923, "BMS2 max. Battery Discharge Current (max)", Kind.BMS),
Voltage("bms2_bat_voltage", 47924, "BMS2 Battery Voltage", Kind.BMS),
Current("bms2_bat_current", 47925, "BMS2 Battery Current", Kind.BMS),
#
Integer("bms2_bat_soc", 47926, "BMS2 Battery State of Charge", "%", Kind.BMS),
Integer("bms2_bat_soh", 47927, "BMS2 Battery State of Health", "%", Kind.BMS),
Temp("bms2_bat_temperature", 47928, "BMS2 Battery Temperature", Kind.BMS),
Long("bms2_bat_warning-code", 47929, "BMS2 Battery Warning Code"),
# Reserved
Long("bms2_bat_alarm-code", 47931, "BMS2 Battery Alarm Code"),
Integer("bms2_status", 47933, "BMS2 Status"),
Integer("bms2_comm_loss_disable", 47934, "BMS2 Communication Loss Disable"),
# RW settings of BMS voltage rate
Integer("bms2_battery_string_rate_v", 47935, "BMS2 Battery String Rate Voltage"),
)
# Settings added in ARM firmware 19
__settings_arm_fw_19: Tuple[Sensor, ...] = (
Integer("fast_charging", 47545, "Fast Charging Enabled", "", Kind.BAT),
Integer("fast_charging_soc", 47546, "Fast Charging SoC", "%", Kind.BAT),
EcoModeV2("eco_mode_1", 47547, "Eco Mode Group 1"),
ByteH("eco_mode_1_switch", 47549, "Eco Mode Group 1 Switch"),
EcoModeV2("eco_mode_2", 47553, "Eco Mode Group 2"),
ByteH("eco_mode_2_switch", 47555, "Eco Mode Group 2 Switch"),
EcoModeV2("eco_mode_3", 47559, "Eco Mode Group 3"),
ByteH("eco_mode_3_switch", 47561, "Eco Mode Group 3 Switch"),
EcoModeV2("eco_mode_4", 47565, "Eco Mode Group 4"),
ByteH("eco_mode_4_switch", 47567, "Eco Mode Group 4 Switch"),
Integer("load_control_mode", 47595, "Load Control Mode", "", Kind.AC),
Integer("load_control_switch", 47596, "Load Control Switch", "", Kind.AC),
Integer("load_control_soc", 47597, "Load Control SoC", "", Kind.AC),
Integer("hardware_feed_power", 47599, "Hardware Feed Power"),
Integer("fast_charging_power", 47603, "Fast Charging Power", "%", Kind.BAT),
)
# Settings added in ARM firmware 22
__settings_arm_fw_22: Tuple[Sensor, ...] = (
Long("peak_shaving_power_limit", 47542, "Peak Shaving Power Limit"),
Integer("peak_shaving_soc", 47544, "Peak Shaving SoC"),
# EcoModeV2("eco_modeV2_5", 47571, "Eco Mode Version 2 Power Group 5"),
# EcoModeV2("eco_modeV2_6", 47577, "Eco Mode Version 2 Power Group 6"),
# EcoModeV2("eco_modeV2_7", 47583, "Eco Mode Version 2 Power Group 7"),
PeakShavingMode("peak_shaving_mode", 47589, "Peak Shaving Mode"),
Integer("dod_holding", 47602, "DoD Holding", "", Kind.BAT),
Integer("backup_mode_enable", 47605, "Backup Mode Switch"),
Integer("max_charge_power", 47606, "Max Charge Power"),
Integer("smart_charging_enable", 47609, "Smart Charging Mode Switch"),
Integer("eco_mode_enable", 47612, "Eco Mode Switch"),
)
def __init__(self, host: str, port: int, comm_addr: int = 0, timeout: int = 1, retries: int = 3):
super().__init__(host, port, comm_addr if comm_addr else 0xf7, timeout, retries)
self._READ_DEVICE_VERSION_INFO: ProtocolCommand = self._read_command(0x88b8, 0x0021)
self._READ_RUNNING_DATA: ProtocolCommand = self._read_command(0x891c, 0x007d)
self._READ_METER_DATA: ProtocolCommand = self._read_command(0x8ca0, 0x2d)
self._READ_METER_DATA_EXTENDED: ProtocolCommand = self._read_command(0x8ca0, 0x3a)
self._READ_METER_DATA_EXTENDED2: ProtocolCommand = self._read_command(0x8ca0, 0x7d)
self._READ_BATTERY_INFO: ProtocolCommand = self._read_command(0x9088, 0x0018)
self._READ_BATTERY2_INFO: ProtocolCommand = self._read_command(0x9858, 0x0016)
self._READ_MPPT_DATA: ProtocolCommand = self._read_command(0x89e5, 0x3d)
self._has_eco_mode_v2: bool = True
self._has_peak_shaving: bool = True
self._has_battery: bool = True
self._has_battery2: bool = False
self._has_meter_extended: bool = False
self._has_meter_extended2: bool = False
self._has_mppt: bool = False
self._sensors = self.__all_sensors
self._sensors_battery = self.__all_sensors_battery
self._sensors_battery2 = self.__all_sensors_battery2
self._sensors_meter = self.__all_sensors_meter
self._sensors_mppt = self.__all_sensors_mppt
self._settings: dict[str, Sensor] = {s.id_: s for s in self.__all_settings}
@staticmethod
def _single_phase_only(s: Sensor) -> bool:
"""Filter to exclude phase2/3 sensors on single phase inverters"""
return not ((s.id_.endswith('2') or s.id_.endswith('3')) and 'pv' not in s.id_)
@staticmethod
def _not_extended_meter(s: Sensor) -> bool:
"""Filter to exclude extended meter sensors"""
return s.offset < 36045
@staticmethod
def _not_extended_meter2(s: Sensor) -> bool:
"""Filter to exclude extended meter sensors"""
return s.offset < 36058
async def read_device_info(self):
response = await self._read_from_socket(self._READ_DEVICE_VERSION_INFO)
response = response.response_data()
# Modbus registers from 35000 - 35032
self.modbus_version = read_unsigned_int(response, 0)
self.rated_power = read_unsigned_int(response, 2)
self.ac_output_type = read_unsigned_int(response, 4) # 0: 1-phase, 1: 3-phase (4 wire), 2: 3-phase (3 wire)
self.serial_number = self._decode(response[6:22]) # 35003 - 350010
self.model_name = self._decode(response[22:32]) # 35011 - 35015
self.dsp1_version = read_unsigned_int(response, 32) # 35016
self.dsp2_version = read_unsigned_int(response, 34) # 35017
self.dsp_svn_version = read_unsigned_int(response, 36) # 35018
self.arm_version = read_unsigned_int(response, 38) # 35019
self.arm_svn_version = read_unsigned_int(response, 40) # 35020
self.firmware = self._decode(response[42:54]) # 35021 - 35027
self.arm_firmware = self._decode(response[54:66]) # 35027 - 35032
if not is_4_mppt(self) and self.rated_power < 15000:
# This inverter does not have 4 MPPTs or PV strings
self._sensors = tuple(filter(lambda s: not ('pv4' in s.id_), self._sensors))
self._sensors = tuple(filter(lambda s: not ('pv3' in s.id_), self._sensors))
if is_single_phase(self):
# this is single phase inverter, filter out all L2 and L3 sensors
self._sensors = tuple(filter(self._single_phase_only, self._sensors))
self._sensors_meter = tuple(filter(self._single_phase_only, self._sensors_meter))
if is_2_battery(self) or self.rated_power >= 25000:
self._has_battery2 = True
if is_745_platform(self) or self.rated_power >= 15000:
self._has_mppt = True
self._has_meter_extended = True
self._has_meter_extended2 = True
else:
self._sensors_meter = tuple(filter(self._not_extended_meter, self._sensors_meter))
# Check and add EcoModeV2 settings added in (ETU fw 19)
try:
await self._read_from_socket(self._read_command(47547, 6))
self._settings.update({s.id_: s for s in self.__settings_arm_fw_19})
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.debug("EcoModeV2 settings not supported, switching to EcoModeV1.")
self._has_eco_mode_v2 = False
except RequestFailedException:
logger.debug("Cannot read EcoModeV2 settings, switching to EcoModeV1.")
self._has_eco_mode_v2 = False
# Check and add Peak Shaving settings added in (ETU fw 22)
try:
await self._read_from_socket(self._read_command(47589, 6))
self._settings.update({s.id_: s for s in self.__settings_arm_fw_22})
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.debug("PeakShaving setting not supported, disabling it.")
self._has_peak_shaving = False
except RequestFailedException:
logger.debug("Cannot read _has_peak_shaving settings, disabling it.")
self._has_peak_shaving = False
async def read_runtime_data(self) -> Dict[str, Any]:
response = await self._read_from_socket(self._READ_RUNNING_DATA)
data = self._map_response(response, self._sensors)
self._has_battery = data.get('battery_mode', 0) != 0
if self._has_battery:
try:
response = await self._read_from_socket(self._READ_BATTERY_INFO)
data.update(self._map_response(response, self._sensors_battery))
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.info("Battery values not supported, disabling further attempts.")
self._has_battery = False
else:
raise ex
if self._has_battery2:
try:
response = await self._read_from_socket(self._READ_BATTERY2_INFO)
data.update(
self._map_response(response, self._sensors_battery2))
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.info("Battery 2 values not supported, disabling further attempts.")
self._has_battery2 = False
else:
raise ex
if self._has_meter_extended2:
try:
response = await self._read_from_socket(self._READ_METER_DATA_EXTENDED2)
data.update(self._map_response(response, self._sensors_meter))
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.info("Extended meter values not supported, disabling further attempts.")
self._has_meter_extended2 = False
self._sensors_meter = tuple(filter(self._not_extended_meter2, self._sensors_meter))
response = await self._read_from_socket(self._READ_METER_DATA_EXTENDED)
data.update(
self._map_response(response, self._sensors_meter))
else:
raise ex
elif self._has_meter_extended:
try:
response = await self._read_from_socket(self._READ_METER_DATA_EXTENDED)
data.update(self._map_response(response, self._sensors_meter))
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.info("Extended meter values not supported, disabling further attempts.")
self._has_meter_extended = False
self._sensors_meter = tuple(filter(self._not_extended_meter, self._sensors_meter))
response = await self._read_from_socket(self._READ_METER_DATA)
data.update(
self._map_response(response, self._sensors_meter))
else:
raise ex
else:
response = await self._read_from_socket(self._READ_METER_DATA)
data.update(self._map_response(response, self._sensors_meter))
if self._has_mppt:
try:
response = await self._read_from_socket(self._READ_MPPT_DATA)
data.update(self._map_response(response, self._sensors_mppt))
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.info("MPPT values not supported, disabling further attempts.")
self._has_mppt = False
else:
raise ex
return data
async def read_setting(self, setting_id: str) -> Any:
setting = self._settings.get(setting_id)
if setting:
return await self._read_setting(setting)
else:
if setting_id.startswith("modbus"):
response = await self._read_from_socket(self._read_command(int(setting_id[7:]), 1))
return int.from_bytes(response.read(2), byteorder="big", signed=True)
else:
raise ValueError(f'Unknown setting "{setting_id}"')
async def _read_setting(self, setting: Sensor) -> Any:
try:
count = (setting.size_ + (setting.size_ % 2)) // 2
response = await self._read_from_socket(self._read_command(setting.offset, count))
return setting.read_value(response)
except RequestRejectedException as ex:
if ex.message == ILLEGAL_DATA_ADDRESS:
logger.debug("Unsupported setting %s", setting.id_)
self._settings.pop(setting.id_, None)
raise ValueError(f'Unknown setting "{setting.id_}"')
return None
async def write_setting(self, setting_id: str, value: Any):
setting = self._settings.get(setting_id)
if setting:
await self._write_setting(setting, value)
else:
if setting_id.startswith("modbus"):
await self._read_from_socket(self._write_command(int(setting_id[7:]), int(value)))
else:
raise ValueError(f'Unknown setting "{setting_id}"')
async def _write_setting(self, setting: Sensor, value: Any):
if setting.size_ == 1:
# modbus can address/store only 16 bit values, read the other 8 bytes
response = await self._read_from_socket(self._read_command(setting.offset, 1))
raw_value = setting.encode_value(value, response.response_data()[0:2])
else:
raw_value = setting.encode_value(value)
if len(raw_value) <= 2:
value = int.from_bytes(raw_value, byteorder="big", signed=True)
await self._read_from_socket(self._write_command(setting.offset, value))
else:
await self._read_from_socket(self._write_multi_command(setting.offset, raw_value))
async def read_settings_data(self) -> Dict[str, Any]:
data = {}
for setting in self.settings():
try:
value = await self.read_setting(setting.id_)
data[setting.id_] = value
except (ValueError, RequestFailedException):
logger.exception("Error reading setting %s.", setting.id_)
data[setting.id_] = None
return data
async def get_grid_export_limit(self) -> int:
return await self.read_setting('grid_export_limit')
async def set_grid_export_limit(self, export_limit: int) -> None:
if export_limit >= 0:
await self.write_setting('grid_export_limit', export_limit)
async def get_operation_modes(self, include_emulated: bool) -> Tuple[OperationMode, ...]:
result = [e for e in OperationMode]
if not self._has_peak_shaving:
result.remove(OperationMode.PEAK_SHAVING)
if not is_745_platform(self):
result.remove(OperationMode.SELF_USE)
if not include_emulated:
result.remove(OperationMode.ECO_CHARGE)
result.remove(OperationMode.ECO_DISCHARGE)
return tuple(result)
async def get_operation_mode(self) -> OperationMode | None:
mode_id = await self.read_setting('work_mode')
try:
mode = OperationMode(mode_id)
except ValueError:
logger.debug("Unknown work_mode value %s", mode_id)
return None
if OperationMode.ECO != mode:
return mode
eco_mode = await self.read_setting('eco_mode_1')
if eco_mode.is_eco_charge_mode():
return OperationMode.ECO_CHARGE
elif eco_mode.is_eco_discharge_mode():
return OperationMode.ECO_DISCHARGE
else:
return OperationMode.ECO
async def set_operation_mode(self, operation_mode: OperationMode, eco_mode_power: int = 100,
eco_mode_soc: int = 100) -> None:
if operation_mode == OperationMode.GENERAL:
await self.write_setting('work_mode', 0)
await self._set_offline(False)
await self._clear_battery_mode_param()
elif operation_mode == OperationMode.OFF_GRID:
await self.write_setting('work_mode', 1)
await self._set_offline(True)
await self.write_setting('backup_supply', 1)
await self.write_setting('cold_start', 4)
await self._clear_battery_mode_param()
elif operation_mode == OperationMode.BACKUP:
await self.write_setting('work_mode', 2)
await self._set_offline(False)
await self._clear_battery_mode_param()
elif operation_mode == OperationMode.ECO:
await self.write_setting('work_mode', 3)
await self._set_offline(False)
elif operation_mode == OperationMode.PEAK_SHAVING:
await self.write_setting('work_mode', 4)
await self._set_offline(False)
await self._clear_battery_mode_param()
elif operation_mode == OperationMode.SELF_USE:
await self.write_setting('work_mode', 5)
await self._set_offline(False)
await self._clear_battery_mode_param()
elif operation_mode in (OperationMode.ECO_CHARGE, OperationMode.ECO_DISCHARGE):
if eco_mode_power < 0 or eco_mode_power > 100:
raise ValueError()
if eco_mode_soc < 0 or eco_mode_soc > 100:
raise ValueError()
eco_mode: EcoMode | Sensor = self._settings.get('eco_mode_1')
# Load the current values to try to detect schedule type
try:
await self._read_setting(eco_mode)
except ValueError:
pass
eco_mode.set_schedule_type(ScheduleType.ECO_MODE, is_745_platform(self))
if operation_mode == OperationMode.ECO_CHARGE:
await self.write_setting('eco_mode_1', eco_mode.encode_charge(eco_mode_power, eco_mode_soc))
else:
await self.write_setting('eco_mode_1', eco_mode.encode_discharge(eco_mode_power))
await self.write_setting('eco_mode_2_switch', 0)
await self.write_setting('eco_mode_3_switch', 0)
await self.write_setting('eco_mode_4_switch', 0)
await self.write_setting('work_mode', 3)
await self._set_offline(False)
async def get_ongrid_battery_dod(self) -> int:
return 100 - await self.read_setting('battery_discharge_depth')
async def set_ongrid_battery_dod(self, dod: int) -> None:
if 0 <= dod <= 100:
await self.write_setting('battery_discharge_depth', 100 - dod)
def sensors(self) -> Tuple[Sensor, ...]:
result = self._sensors + self._sensors_meter
if self._has_battery:
result = result + self._sensors_battery
if self._has_battery2:
result = result + self._sensors_battery2
if self._has_mppt:
result = result + self._sensors_mppt
return result
def settings(self) -> Tuple[Sensor, ...]:
return tuple(self._settings.values())
async def _clear_battery_mode_param(self) -> None:
await self._read_from_socket(self._write_command(0xb9ad, 1))
async def _set_offline(self, mode: bool) -> None:
value = bytes.fromhex('00070000') if mode else bytes.fromhex('00010000')
await self._read_from_socket(self._write_multi_command(0xb997, value))
|