1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151
|
Brain Vision Data Exchange Header File Version 2.0
; Data created from history path
[Common Infos]
Codepage=UTF-8
DataFile=test.eeg
MarkerFile=test.vmrk
DataFormat=BINARY
; Data orientation: VECTORIZED=ch1,pt1, ch1,pt2..., MULTIPLEXED=ch1,pt1, ch2,pt1 ...
DataOrientation=MULTIPLEXED
DataType=TIMEDOMAIN
NumberOfChannels=32
; Sampling interval in microseconds if time domain (convert to Hertz:
; 1000000 / SamplingInterval) or in Hertz if frequency domain:
SamplingInterval=1000
[User Infos]
; Each entry: Prop<Number>=<Type>,<Name>,<Value>,<Value2>,...,<ValueN>
; Property number must be unique. Types can be int, single, string, bool, byte, double, uint
; or arrays of those, indicated int-array etc
; Array types have more than one value, number of values determines size of array.
; Fields are delimited by commas, commas in strings are written \1
[Binary Infos]
BinaryFormat=INT_16
[Channel Infos]
; Each entry: Ch<Channel number>=<Name>,<Reference channel name>,
; <Resolution in "Unit">,<Unit>, Future extensions...
; Fields are delimited by commas, some fields might be omitted (empty).
; Commas in channel names are coded as "\1".
Ch1=FP1,,500,nV
Ch2=FP2,,0.5,µV
Ch3=F3,,0.5,µV
Ch4=F4,,0.5,µV
Ch5=C3,,0.5,µV
Ch6=C4,,0.5,µV
Ch7=P3,,0.5,µV
Ch8=P4,,0.5,µV
Ch9=O1,,0.5,µV
Ch10=O2,,0.5,µV
Ch11=F7,,0.5,µV
Ch12=F8,,0.5,µV
Ch13=P7,,0.5,µV
Ch14=P8,,0.5,µV
Ch15=Fz,,0.5,µV
Ch16=FCz,,0.5,µV
Ch17=Cz,,0.5,µV
Ch18=CPz,,0.5,µV
Ch19=Pz,,0.5,µV
Ch20=POz,,0.5,µV
Ch21=FC1,,0.5,µV
Ch22=FC2,,0.5,µV
Ch23=CP1,,0.5,µV
Ch24=CP2,,0.5,µV
Ch25=FC5,,0.5,µV
Ch26=FC6,,0.5,µV
Ch27=CP5,,0.5,BS
Ch28=CP6,,0.5,µS
Ch29=HL,,0.5,ARU
Ch30=HR,,0.5,uS
Ch31=Vb,,0.5,S
Ch32=ReRef,,0.5,C
[Comment]
A m p l i f i e r S e t u p
============================
Number of channels: 32
Sampling Rate [Hz]: 1000
Sampling Interval [µS]: 1000
Channels
--------
# Name Phys. Chn. Resolution / Unit Low Cutoff [s] High Cutoff [Hz] Notch [Hz] Series Res. [kOhm] Gradient Offset
1 FP1 1 500 nV DC 250 Off 0
2 FP2 2 0.5 µV DC 250 Off 0
3 F3 3 0.5 µV DC 250 Off 0
4 F4 4 0.5 µV DC 250 Off 0
5 C3 5 0.5 µV DC 250 Off 0
6 C4 6 0.5 µV DC 250 Off 0
7 P3 7 0.5 µV DC 250 Off 0
8 P4 8 0.5 µV DC 250 Off 0
9 O1 9 0.5 µV DC 250 Off 0
10 O2 10 0.5 µV DC 250 Off 0
11 F7 11 0.5 µV DC 250 Off 0
12 F8 12 0.5 µV DC 250 Off 0
13 P7 13 0.5 µV DC 250 Off 0
14 P8 14 0.5 µV DC 250 Off 0
15 Fz 15 0.5 µV DC 250 Off 0
16 FCz 16 0.5 µV DC 250 Off 0
17 Cz 17 0.5 µV DC 250 Off 0
18 CPz 18 0.5 µV DC 250 Off 0
19 Pz 19 0.5 µV DC 250 Off 0
20 POz 20 0.5 µV DC 250 Off 0
21 FC1 21 0.5 µV DC 250 Off 0
22 FC2 22 0.5 µV DC 250 Off 0
23 CP1 23 0.5 µV DC 250 Off 0
24 CP2 24 0.5 µV DC 250 Off 0
25 FC5 25 0.5 µV DC 250 Off 0
26 FC6 26 0.5 µV DC 250 Off 0
27 CP5 27 0.5 BS DC 250 Off 0
28 CP6 28 0.5 µS DC 250 Off 0
29 HL 29 0.5 ARU DC 250 Off 0
30 HR 30 0.5 uS DC 250 Off 0
31 Vb 31 0.5 S DC 250 Off 0
32 ReRef 32 0.5 C DC 250 Off 0
S o f t w a r e F i l t e r s
==============================
Disabled
Data Electrodes Selected Impedance Measurement Range: 0 - 100 kOhm
Ground Electrode Selected Impedance Measurement Range: 0 - 10 kOhm
Reference Electrode Selected Impedance Measurement Range: 0 - 10 kOhm
Impedance [kOhm] at 16:12:27 :
FP1: ???
FP2: ???
F3: ???
F4: ???
C3: ???
C4: ???
P3: ???
P4: ???
O1: ???
O2: ???
F7: ???
F8: ???
P7: ???
P8: ???
Fz: ???
FCz: ???
Cz: ???
CPz: ???
Pz: ???
POz: ???
FC1: ???
FC2: ???
CP1: ???
CP2: ???
FC5: ???
FC6: ???
CP5: ???
CP6: ???
HL: ???
HR: ???
Vb: ???
ReRef: ???
Ref: 0
Gnd: 4
|