1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256
|
# -*- coding: utf-8 -*-
"""
.. _tut-set-eeg-ref:
=========================
Setting the EEG reference
=========================
This tutorial describes how to set or change the EEG reference in MNE-Python.
As usual we'll start by importing the modules we need, loading some
:ref:`example data <sample-dataset>`, and cropping it to save memory. Since
this tutorial deals specifically with EEG, we'll also restrict the dataset to
just a few EEG channels so the plots are easier to see:
"""
# %%
import os
import mne
sample_data_folder = mne.datasets.sample.data_path()
sample_data_raw_file = os.path.join(sample_data_folder, 'MEG', 'sample',
'sample_audvis_raw.fif')
raw = mne.io.read_raw_fif(sample_data_raw_file, verbose=False)
raw.crop(tmax=60).load_data()
raw.pick(['EEG 0{:02}'.format(n) for n in range(41, 60)])
# %%
# Background
# ^^^^^^^^^^
#
# EEG measures a voltage (difference in electric potential) between each
# electrode and a reference electrode. This means that whatever signal is
# present at the reference electrode is effectively subtracted from all the
# measurement electrodes. Therefore, an ideal reference signal is one that
# captures *none* of the brain-specific fluctuations in electric potential,
# while capturing *all* of the environmental noise/interference that is being
# picked up by the measurement electrodes.
#
# In practice, this means that the reference electrode is often placed in a
# location on the subject's body and close to their head (so that any
# environmental interference affects the reference and measurement electrodes
# similarly) but as far away from the neural sources as possible (so that the
# reference signal doesn't pick up brain-based fluctuations). Typical reference
# locations are the subject's earlobe, nose, mastoid process, or collarbone.
# Each of these has advantages and disadvantages regarding how much brain
# signal it picks up (e.g., the mastoids pick up a fair amount compared to the
# others), and regarding the environmental noise it picks up (e.g., earlobe
# electrodes may shift easily, and have signals more similar to electrodes on
# the same side of the head).
#
# Even in cases where no electrode is specifically designated as the reference,
# EEG recording hardware will still treat one of the scalp electrodes as the
# reference, and the recording software may or may not display it to you (it
# might appear as a completely flat channel, or the software might subtract out
# the average of all signals before displaying, making it *look like* there is
# no reference).
#
#
# Setting or changing the reference channel
# ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
#
# If you want to recompute your data with a different reference than was used
# when the raw data were recorded and/or saved, MNE-Python provides the
# :meth:`~mne.io.Raw.set_eeg_reference` method on :class:`~mne.io.Raw` objects
# as well as the :func:`mne.add_reference_channels` function. To use an
# existing channel as the new reference, use the
# :meth:`~mne.io.Raw.set_eeg_reference` method; you can also designate multiple
# existing electrodes as reference channels, as is sometimes done with mastoid
# references:
# code lines below are commented out because the sample data doesn't have
# earlobe or mastoid channels, so this is just for demonstration purposes:
# use a single channel reference (left earlobe)
# raw.set_eeg_reference(ref_channels=['A1'])
# use average of mastoid channels as reference
# raw.set_eeg_reference(ref_channels=['M1', 'M2'])
# use a bipolar reference (contralateral)
# raw.set_bipolar_reference(anode='[F3'], cathode=['F4'])
# %%
# If a scalp electrode was used as reference but was not saved alongside the
# raw data (reference channels often aren't), you may wish to add it back to
# the dataset before re-referencing. For example, if your EEG system recorded
# with channel ``Fp1`` as the reference but did not include ``Fp1`` in the data
# file, using :meth:`~mne.io.Raw.set_eeg_reference` to set (say) ``Cz`` as the
# new reference will then subtract out the signal at ``Cz`` *without restoring
# the signal at* ``Fp1``. In this situation, you can add back ``Fp1`` as a flat
# channel prior to re-referencing using :func:`~mne.add_reference_channels`.
# (Since our example data doesn't use the `10-20 electrode naming system`_, the
# example below adds ``EEG 999`` as the missing reference, then sets the
# reference to ``EEG 050``.) Here's how the data looks in its original state:
raw.plot()
# %%
# By default, :func:`~mne.add_reference_channels` returns a copy, so we can go
# back to our original ``raw`` object later. If you wanted to alter the
# existing :class:`~mne.io.Raw` object in-place you could specify
# ``copy=False``.
# add new reference channel (all zero)
raw_new_ref = mne.add_reference_channels(raw, ref_channels=['EEG 999'])
raw_new_ref.plot()
# %%
# .. KEEP THESE BLOCKS SEPARATE SO FIGURES ARE BIG ENOUGH TO READ
# set reference to `EEG 050`
raw_new_ref.set_eeg_reference(ref_channels=['EEG 050'])
raw_new_ref.plot()
# %%
# Notice that the new reference (``EEG 050``) is now flat, while the original
# reference channel that we added back to the data (``EEG 999``) has a non-zero
# signal. Notice also that ``EEG 053`` (which is marked as "bad" in
# ``raw.info['bads']``) is not affected by the re-referencing.
#
#
# Setting average reference
# ^^^^^^^^^^^^^^^^^^^^^^^^^
#
# To set a "virtual reference" that is the average of all channels, you can use
# :meth:`~mne.io.Raw.set_eeg_reference` with ``ref_channels='average'``. Just
# as above, this will not affect any channels marked as "bad", nor will it
# include bad channels when computing the average. However, it does modify the
# :class:`~mne.io.Raw` object in-place, so we'll make a copy first so we can
# still go back to the unmodified :class:`~mne.io.Raw` object later:
# sphinx_gallery_thumbnail_number = 4
# use the average of all channels as reference
raw_avg_ref = raw.copy().set_eeg_reference(ref_channels='average')
raw_avg_ref.plot()
# %%
# .. _section-avg-ref-proj:
#
# Creating the average reference as a projector
# ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
#
# If using an average reference, it is possible to create the reference as a
# :term:`projector` rather than subtracting the reference from the data
# immediately by specifying ``projection=True``:
raw.set_eeg_reference('average', projection=True)
print(raw.info['projs'])
# %%
# Creating the average reference as a projector has a few advantages:
#
# 1. It is possible to turn projectors on or off when plotting, so it is easy
# to visualize the effect that the average reference has on the data.
#
# 2. If additional channels are marked as "bad" or if a subset of channels are
# later selected, the projector will be re-computed to take these changes
# into account (thus guaranteeing that the signal is zero-mean).
#
# 3. If there are other unapplied projectors affecting the EEG channels (such
# as SSP projectors for removing heartbeat or blink artifacts), EEG
# re-referencing cannot be performed until those projectors are either
# applied or removed; adding the EEG reference as a projector is not subject
# to that constraint. (The reason this wasn't a problem when we applied the
# non-projector average reference to ``raw_avg_ref`` above is that the
# empty-room projectors included in the sample data :file:`.fif` file were
# only computed for the magnetometers.)
for title, proj in zip(['Original', 'Average'], [False, True]):
with mne.viz.use_browser_backend('matplotlib'):
fig = raw.plot(proj=proj, n_channels=len(raw))
# make room for title
fig.subplots_adjust(top=0.9)
fig.suptitle('{} reference'.format(title), size='xx-large', weight='bold')
# %%
# Using an infinite reference (REST)
# ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
#
# To use the "point at infinity" reference technique described in
# :footcite:`Yao2001` requires a forward model, which we can create in a few
# steps. Here we use a fairly large spacing of vertices (``pos`` = 15 mm) to
# reduce computation time; a 5 mm spacing is more typical for real data
# analysis:
raw.del_proj() # remove our average reference projector first
sphere = mne.make_sphere_model('auto', 'auto', raw.info)
src = mne.setup_volume_source_space(sphere=sphere, exclude=30., pos=15.)
forward = mne.make_forward_solution(raw.info, trans=None, src=src, bem=sphere)
raw_rest = raw.copy().set_eeg_reference('REST', forward=forward)
for title, _raw in zip(['Original', 'REST (∞)'], [raw, raw_rest]):
with mne.viz.use_browser_backend('matplotlib'):
fig = _raw.plot(n_channels=len(raw), scalings=dict(eeg=5e-5))
# make room for title
fig.subplots_adjust(top=0.9)
fig.suptitle('{} reference'.format(title), size='xx-large', weight='bold')
# %%
# Using a bipolar reference
# ^^^^^^^^^^^^^^^^^^^^^^^^^
#
# To create a bipolar reference, you can use :meth:`~mne.set_bipolar_reference`
# along with the respective channel names for ``anode`` and ``cathode`` which
# creates a new virtual channel that takes the difference between two
# specified channels (anode and cathode) and drops the original channels by
# default. The new virtual channel will be annotated with the channel info of
# the anode with location set to ``(0, 0, 0)`` and coil type set to
# ``EEG_BIPOLAR`` by default. Here we use a contralateral/transverse bipolar
# reference between channels ``EEG 054`` and ``EEG 055`` as described in
# :footcite:`YaoEtAl2019` which creates a new virtual channel
# named ``EEG 054-EEG 055``.
raw_bip_ref = mne.set_bipolar_reference(raw, anode=['EEG 054'],
cathode=['EEG 055'])
raw_bip_ref.plot()
# %%
# EEG reference and source modeling
# ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
#
# If you plan to perform source modeling (either with EEG or combined EEG/MEG
# data), it is **strongly recommended** to use the
# average-reference-as-projection approach. It is important to use an average
# reference because using a specific
# reference sensor (or even an average of a few sensors) spreads the forward
# model error from the reference sensor(s) into all sensors, effectively
# amplifying the importance of the reference sensor(s) when computing source
# estimates. In contrast, using the average of all EEG channels as reference
# spreads the forward modeling error evenly across channels, so no one channel
# is weighted more strongly during source estimation. See also this `FieldTrip
# FAQ on average referencing`_ for more information.
#
# The main reason for specifying the average reference as a projector was
# mentioned in the previous section: an average reference projector adapts if
# channels are dropped, ensuring that the signal will always be zero-mean when
# the source modeling is performed. In contrast, applying an average reference
# by the traditional subtraction method offers no such guarantee.
#
# For these reasons, when performing inverse imaging, *MNE-Python will raise
# a ``ValueError`` if there are EEG channels present and something other than
# an average reference strategy has been specified*.
#
# .. LINKS
#
# .. _`FieldTrip FAQ on average referencing`:
# http://www.fieldtriptoolbox.org/faq/why_should_i_use_an_average_reference_for_eeg_source_reconstruction/
# .. _`10-20 electrode naming system`:
# https://en.wikipedia.org/wiki/10%E2%80%9320_system_(EEG)
#
#
# References
# ^^^^^^^^^^
# .. footbibliography::
|