1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203
|
*DMPREC
DOUBLE PRECISION FUNCTION DMPREC()
C***BEGIN PROLOGUE DPREC
C***REFER TO DODR,DODRC
C***ROUTINES CALLED (NONE)
C***DATE WRITTEN 860529 (YYMMDD)
C***REVISION DATE 920304 (YYMMDD)
C***PURPOSE DETERMINE MACHINE PRECISION FOR TARGET MACHINE AND COMPILER
C ASSUMING FLOATING-POINT NUMBERS ARE REPRESENTED IN THE
C T-DIGIT, BASE-B FORM
C SIGN (B**E)*( (X(1)/B) + ... + (X(T)/B**T) )
C WHERE 0 .LE. X(I) .LT. B FOR I=1,...,T, AND
C 0 .LT. X(1).
C TO ALTER THIS FUNCTION FOR A PARTICULAR TARGET MACHINE,
C EITHER
C ACTIVATE THE DESIRED SET OF DATA STATEMENTS BY
C REMOVING THE C FROM COLUMN 1
C OR
C SET B, TD AND TS USING I1MACH BY ACTIVATING
C THE DECLARATION STATEMENTS FOR I1MACH
C AND THE STATEMENTS PRECEEDING THE FIRST
C EXECUTABLE STATEMENT BELOW.
C***END PROLOGUE DPREC
C...LOCAL SCALARS
DOUBLE PRECISION
+ B
INTEGER
+ TD,TS
C...EXTERNAL FUNCTIONS
C INTEGER
C + I1MACH
C EXTERNAL
C + I1MACH
C...VARIABLE DEFINITIONS (ALPHABETICALLY)
C DOUBLE PRECISION B
C THE BASE OF THE TARGET MACHINE.
C (MAY BE DEFINED USING I1MACH(10).)
C INTEGER TD
C THE NUMBER OF BASE-B DIGITS IN DOUBLE PRECISION.
C (MAY BE DEFINED USING I1MACH(14).)
C INTEGER TS
C THE NUMBER OF BASE-B DIGITS IN SINGLE PRECISION.
C (MAY BE DEFINED USING I1MACH(11).)
C MACHINE CONSTANTS FOR COMPUTERS FOLLOWING IEEE ARITHMETIC STANDARD
C (E.G., MOTOROLA 68000 BASED MACHINES SUCH AS SUN AND SPARC
C WORKSTATIONS, AND AT&T PC 7300; AND 8087 BASED MICROS SUCH AS THE
C IBM PC AND THE AT&T 6300).
DATA B / 2 /
DATA TS / 24 /
DATA TD / 53 /
C MACHINE CONSTANTS FOR THE BURROUGHS 1700 SYSTEM.
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 60 /
C MACHINE CONSTANTS FOR THE BURROUGHS 5700 SYSTEM
C THE BURROUGHS 6700/7700 SYSTEMS
C DATA B / 8 /
C DATA TS / 13 /
C DATA TD / 26 /
C MACHINE CONSTANTS FOR THE CDC 6000/7000 (FTN5 COMPILER)
C THE CYBER 170/180 SERIES UNDER NOS
C DATA B / 2 /
C DATA TS / 48 /
C DATA TD / 96 /
C MACHINE CONSTANTS FOR THE CDC 6000/7000 (FTN COMPILER)
C THE CYBER 170/180 SERIES UNDER NOS/VE
C THE CYBER 200 SERIES
C DATA B / 2 /
C DATA TS / 47 /
C DATA TD / 94 /
C MACHINE CONSTANTS FOR THE CRAY
C DATA B / 2 /
C DATA TS / 47 /
C DATA TD / 94 /
C MACHINE CONSTANTS FOR THE DATA GENERAL ECLIPSE S/200
C DATA B / 16 /
C DATA TS / 6 /
C DATA TD / 14 /
C MACHINE CONSTANTS FOR THE HARRIS COMPUTER
C DATA B / 2 /
C DATA TS / 23 /
C DATA TD / 38 /
C MACHINE CONSTANTS FOR THE HONEYWELL DPS 8/70
C THE HONEYWELL 600/6000 SERIES
C DATA B / 2 /
C DATA TS / 27 /
C DATA TD / 63 /
C MACHINE CONSTANTS FOR THE HP 2100
C (3 WORD DOUBLE PRECISION OPTION WITH FTN4)
C DATA B / 2 /
C DATA TS / 23 /
C DATA TD / 39 /
C MACHINE CONSTANTS FOR THE HP 2100
C (4 WORD DOUBLE PRECISION OPTION WITH FTN4)
C DATA B / 2 /
C DATA TS / 23 /
C DATA TD / 55 /
C MACHINE CONSTANTS FOR THE IBM 360/370 SERIES
C DATA B / 16 /
C DATA TS / 6 /
C DATA TD / 14 /
C MACHINE CONSTANTS FOR THE IBM PC
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 53 /
C MACHINE CONSTANTS FOR THE INTERDATA (PERKIN ELMER) 7/32
C INTERDATA (PERKIN ELMER) 8/32
C DATA B / 16 /
C DATA TS / 6 /
C DATA TD / 14 /
C MACHINE CONSTANTS FOR THE PDP-10 (KA PROCESSOR).
C DATA B / 2 /
C DATA TS / 27 /
C DATA TD / 54 /
C MACHINE CONSTANTS FOR THE PDP-10 (KI PROCESSOR).
C DATA B / 2 /
C DATA TS / 27 /
C DATA TD / 62 /
C MACHINE CONSTANTS FOR THE PDP-11 SYSTEM
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 56 /
C MACHINE CONSTANTS FOR THE PERKIN-ELMER 3230
C DATA B / 16 /
C DATA TS / 6 /
C DATA TD / 14 /
C MACHINE CONSTANTS FOR THE PRIME 850 AND PRIME 4050
C DATA B / 2 /
C DATA TS / 23 /
C DATA TD / 47 /
C MACHINE CONSTANTS FOR THE SEL SYSTEMS 85/86
C DATA B / 16 /
C DATA TS / 6 /
C DATA TD / 14 /
C MACHINE CONSTANTS FOR SUN AND SPARC WORKSTATIONS
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 53 /
C MACHINE CONSTANTS FOR THE UNIVAC 1100 SERIES
C DATA B / 2 /
C DATA TS / 27 /
C DATA TD / 60 /
C MACHINE CONSTANTS FOR THE VAX-11 WITH FORTRAN IV-PLUS COMPILER
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 56 /
C MACHINE CONSTANTS FOR THE VAX/VMS SYSTEM WITHOUT G_FLOATING
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 56 /
C MACHINE CONSTANTS FOR THE VAX/VMS SYSTEM WITH G_FLOATING
C DATA B / 2 /
C DATA TS / 24 /
C DATA TD / 53 /
C MACHINE CONSTANTS FOR THE XEROX SIGMA 5/7/9
C DATA B / 16 /
C DATA TS / 6 /
C DATA TD / 14 /
C***FIRST EXECUTABLE STATEMENT DMPREC
C B = I1MACH(10)
C TS = I1MACH(11)
C TD = I1MACH(14)
DMPREC = B ** (1-TD)