File: dpt_13.py

package info (click to toggle)
python-xknx 3.10.1-1
  • links: PTS, VCS
  • area: main
  • in suites: forky, sid
  • size: 4,044 kB
  • sloc: python: 40,087; javascript: 8,556; makefile: 32; sh: 12
file content (116 lines) | stat: -rw-r--r-- 2,527 bytes parent folder | download | duplicates (2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
"""Implementation of Basic KNX 4-Byte signed (2's complement) values."""

from __future__ import annotations

from .dpt import DPTNumeric, DPTStructIntMixin


class DPT4ByteSigned(DPTStructIntMixin, DPTNumeric):
    """
    Abstraction for KNX 4 Byte "32-bit signed".

    DPT 13.***
    """

    dpt_main_number = 13
    dpt_sub_number: int | None = None
    value_type = "4byte_signed"
    payload_length = 4

    value_min = -2147483648
    value_max = 2147483647
    resolution = 1

    _struct_format = ">i"


class DPTValue4Count(DPT4ByteSigned):
    """DPT 13.001 DPT_Value_4_Count (pulse)."""

    dpt_main_number = 13
    dpt_sub_number = 1
    value_type = "pulse_4byte"
    unit = "counter pulses"


class DPTFlowRateM3H(DPT4ByteSigned):
    """DPT 13.002 DPT_FlowRate_m3/h (m³/h)."""

    dpt_main_number = 13
    dpt_sub_number = 2
    value_type = "flow_rate_m3h"
    unit = "m³/h"


class DPTActiveEnergy(DPT4ByteSigned):
    """DPT 13.010 DPT_ActiveEnergy (Wh)."""

    dpt_main_number = 13
    dpt_sub_number = 10
    value_type = "active_energy"
    unit = "Wh"
    ha_device_class = "energy"


class DPTApparantEnergy(DPT4ByteSigned):
    """DPT 13.011 DPT_ActiveEnergy (VAh)."""

    dpt_main_number = 13
    dpt_sub_number = 11
    value_type = "apparant_energy"
    unit = "VAh"


class DPTReactiveEnergy(DPT4ByteSigned):
    """DPT 13.012 DPT_ActiveEnergy (VARh)."""

    dpt_main_number = 13
    dpt_sub_number = 12
    value_type = "reactive_energy"
    unit = "VARh"


class DPTActiveEnergykWh(DPT4ByteSigned):
    """DPT 13.013 DPT_ActiveEnergy_kWh (kWh)."""

    dpt_main_number = 13
    dpt_sub_number = 13
    value_type = "active_energy_kwh"
    unit = "kWh"
    ha_device_class = "energy"


class DPTApparantEnergykVAh(DPT4ByteSigned):
    """DPT 13.014 DPT_ActiveEnergy_kVAh (kVAh)."""

    dpt_main_number = 13
    dpt_sub_number = 14
    value_type = "apparant_energy_kvah"
    unit = "kVAh"


class DPTReactiveEnergykVARh(DPT4ByteSigned):
    """DPT 13.015 DPT_ActiveEnergy (kVARh)."""

    dpt_main_number = 13
    dpt_sub_number = 15
    value_type = "reactive_energy_kvarh"
    unit = "kVARh"


class DPTActiveEnergyMWh(DPT4ByteSigned):
    """DPT 13.016 DPT_ActiveEnergy_MWh (MWh)."""

    dpt_main_number = 13
    dpt_sub_number = 16
    value_type = "active_energy_mwh"
    unit = "MWh"


class DPTLongDeltaTimeSec(DPT4ByteSigned):
    """DPT 13.100 DPT_LongDeltaTimeSec (s)."""

    dpt_main_number = 13
    dpt_sub_number = 100
    value_type = "long_delta_timesec"
    unit = "s"