1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307
|
Plustek.changes - Gerhard Jaeger <gerhard@gjaeger.de>
=====================================================
Note: All other not mentioned builds have never been released.
V 0.52-11 (2013-02-13)
---------------------
Added support for Q-Scan A6 scanner (see report #312073)
V 0.52-10 (2012-03-19)
---------------------
Fixed batch scanning
V 0.52-9 (2009-04-27)
---------------------
Tweaked highspeed settings for Epson 1260
V 0.52-8 (2008-08-25)
---------------------
Added preliminary support for Visioneer XP100
Tweaked entry for LM9831 version of Plustek UT12
V 0.52-7 (2007-12-13)
---------------------
Fixed alignment issues for archs like XScale/ARM
Fixed dumppic function to get valid grayscale pictures
V 0.52-6 (2007-11-23)
---------------------
Tweaked TravelScan464 settings.
Improved AFE gain calculation for CIS devices. This should avoid
stripes in the scanned images.
V 0.52-4 (2007-11-16)
---------------------
Tweaked TravelScan464 settings
Added possibility to disable dark-calibration with lamp on
(touches devices like CanoScan1220 etc)
Use attribute packed for data access structs
V 0.52-4 (2007-11-07)
---------------------
Added support for Syscan TravelScan464
V 0.52-3 (2007-07-26)
---------------------
Checked UMAX3400/3450 models
Force output bit set (MIO), when lamp is switched
V 0.52-2 (2007-07-10)
---------------------
Added flag to allow only 1- and 8-bit scanmodes. The Q-Scan does
not seem to support 14-bit modes.
V 0.52-1 (2007-06-29)
---------------------
Added sheetfed device Q-Scan USB001 from Portable Peripherals
Fixed Mustek Bearpaw and did some speedup (bugreports #304343 and
#301763)
Fixed calibration for senororders other that RGB
V 0.51-16 (2007-03-05)
----------------------
Added CanoScan to all Canon device strings.
Identified one more Plustek device as U24.
Fixed button handling for Plustek/KYE devices and
added some more debug messages.
V 0.51-15 (2006-11-22)
----------------------
Fixed option descriptors (bugreport #303786)
V 0.51-14 (2006-08-11)
----------------------
Lowered speed for LiDE20/30 models in low resolution mode (<75dpi)
V 0.51-13 (2006-08-09)
----------------------
Changed sane.type to "flatbed scanner" only
Fixed motorsettings for LiDE30 (bugreport #303722)
Fixed LiDE20 settings. Got some reports of non-working devs, although
my N670U is working fine. Lowered the max speeds and increased the
MCLK-div for fast movement. (bugreport #303695)
V 0.51-12 (2006-06-30)
----------------------
Fixed bit-depth selection
V 0.51-11 (2006-06-08)
----------------------
Fixed calibration: All modes will be coarse calibrated now, fine calibration
will be done only for 8 bit modes.
Fixed paper eject during startup.
V 0.51-10 (2006-05-28)
---------------------
Released
V 0.51-8 (2006-04-09)
---------------------
Added cache for fine calibration (CIS devices only)
Added support for sheet-fed scanner (CIS devices only)
Added support for Syscan TravelScan662
V 0.50-10 (2006-01-31)
---------------------
Fixed CanoScan N1220U settings.
V 0.50-9 (2006-01-19)
---------------------
Added high-speed setting for HP2200.
Fixed constraint_type for OPT_BUTTON.
V 0.50-8 (2006-01-18)
---------------------
Fixed CanoScan N670U settings (bugreport #302433).
V 0.50-7 (2005-10-28)
---------------------
Changed high-speed setting for UMAX 3400, due to bugreport #302317.
Added disable speeup feature (as option).
Fixed CanoScan N650U settings (bugreport #302433).
V 0.50-6 (2005-10-25)
---------------------
Fixed segfault in fine calibration for CIS devices.
Tweaked LiDE25 settings (thanks to Gerd Cendelin for lending me
his LiDE25).
Let 1200DPI CIS devices use now the green-channel for gray scans.
V 0.50-5 (2005-10-21)
---------------------
Fixed high-speed feature of CanoScan D660U.
V 0.50-4 (2005-10-02)
---------------------
Updated motor settings for Canoscan LiDE25, thanks to
Stephan February <stephanf@singnet.com.sg> for providing these
values.
V 0.50-3 (2005-08-22)
---------------------
Fixed problem, when trying to scan at resolutions beyond the
optical one (sensor stops too early)
V 0.50-2 (2005-08-19)
---------------------
More cleanup.
Removed obsolete _WAF_BLACKFINE.
LiDE20 does not seem to have a reliable black calibration area,
so the devices now will switch off the lamp for dark calibration.
Fixed line statistics and added calibration data output.
V 0.50-1 (2005-08-15)
---------------------
Cleanup
Activated IPC between reader-process and parent
Added button support for Plustek/Genius devices
Did some whitespace cleanup and removed those *p typedefs
Tried to improve CIS calibration (somewhat back to 1.0.13)
Added _TWEAK_GAIN definition to allow CIS calibration increase
gain values during basic lamp setup phase
Added call to speedtest to CIS calibration
Fixed CanoScan startup problem (the way misc I/Os will be set
after power-up has done the trick)
V 0.49-8 (2005-08-08)
---------------------
Added LiDE25 settings
V 0.49-7 (2005-07-21)
---------------------
Bugfix release - fixed lampsettings for CIS calibration
V 0.49-6 (2005-07-07)
---------------------
Bugfix release - calibration and segfault :(
V 0.49-5 (2005-07-04)
---------------------
Added IPC between reader-process and parent process to
be pepared for sharing calibration info.
Added button support for backend
V 0.49-4 (2005-06-27)
---------------------
Fixed "double free" problem during sane_exit.
V 0.49-3 (2005-04-18)
---------------------
Fixed backtracking problem, when sensor-speedup is active.
V 0.49-2 (2005-01-12)
---------------------
Tweaked some device settings
Updated copyright info
Using now PhyDpi.y as selector for the motor MCLK range
V 0.49-1 (2004-11-19)
---------------------
Improved multi-device capability
V 0.48-10 (2004-10-30)
----------------------
- Fixed a bug in buffer calculation for CIS devices
V 0.48-9 (2004-10-19)
---------------------
- Use the same option names for RGB gain as umax_pp backend
V 0.48-8 (2004-10-06)
---------------------
- split scanmodes & bit-depths
V 0.48-7 (2004-10-04)
---------------------
- changed some strings according to bug #300963
V 0.48-6 (2004-09-07)
---------------------
- fixed UMAX lamp-off bug
V 0.48-4 (2004-07-26)
---------------------
- added speedup parameters for UMAX3400/3450
- added disableSpeedup option
- added UMAX3400/3450 TPA autodetection
V 0.48-3 (2004-07-16)
---------------------
- improved autowarmup feature
- improved speedup feature
V 0.48-2 (2004-07-07)
---------------------
- fixed binary mode for CanoScan D660U
V 0.48-1 (2004-07-02)
---------------------
- added more options to the frontend interface
- added UMAX 3400 with product ID 0x0050
- added support for the UMAX 3450
- added autowarmup for CFL (most CCD-scanner)
- added speedup for sensor for some devices
- fixed lamp switching problem for D660U
- fixed negative scanning lamp problem
- fixed Gray 16 mode for CanoScan D660U
- code cleanup
V 0.47-11 (2004-04-21)
----------------------
- minor fixes, esp. for MacOSX
- added lamp-off and warmup options to be configurable by backends
V 0.47-8 - 0.47-10
------------------
- never released
V 0.47-7 (2004-02-08)
---------------------
- fixed bypass calibration function for CIS devices
- added lampoff stuff to config file
V 0.47-6 (2004-01-21)
---------------------
- Cleanup work
- Changed lamp off timer for non-setitimer systems
V 0.47-5 (2004-01-09)
---------------------
- Added big-endian code to support also PPC architectures
- Added mov (model override) to support various devices using
the same product ID (namely Mustek BearPaw 1200)
- Added per-model gamma values
- Fixed a bug in the coarse CIS-lamp calibration
- Cleanup work
V 0.47-1 - 0.47-4
-----------------
- never released
V 0.46-9 (2003-11-03)
---------------------
- Added alternate calibration for CIS devices
- Added coarse calibration data-cache
- Moved parallelport code to extra backend file plustek_pp
- Fixed some minor bugs
- Fixed problem with CIS devices using FreeBSD
V 0.46-1 - 0.46-8
-----------------
- never released
V 0.45 (2003-08-05)
-------------------
- Starting this changelog
- Updates since V 0.44:
* better CIS device support
* added CanoScan N1220U, N1240U
* made CanoScan N650U and N670U work
* fixed EPSON 1260 motor killer-bug
* improved TPA scanning
* fixed TPA warmup bug on EPSON 1260/Photo
* fixed Genius device detection problem
* Added Compaq S4-100 (identical to UMAX3400)
|