File: rfc1382.mib

package info (click to toggle)
scotty 2.1.9-1
  • links: PTS
  • area: main
  • in suites: hamm
  • size: 9,984 kB
  • ctags: 4,313
  • sloc: ansic: 35,946; sh: 12,591; tcl: 8,122; yacc: 2,442; makefile: 898; lex: 370
file content (2708 lines) | stat: -rw-r--r-- 115,010 bytes parent folder | download | duplicates (4)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
RFC1382-MIB DEFINITIONS ::= BEGIN

          IMPORTS
                  Counter, Gauge, TimeTicks
                          FROM RFC1155-SMI
                  OBJECT-TYPE
                          FROM RFC-1212
                  DisplayString, transmission
                          FROM RFC1213-MIB
                  TRAP-TYPE
                          FROM RFC-1215
                  EntryStatus
                          FROM RFC1271-MIB
                  PositiveInteger,
                  IfIndexType
                          FROM RFC1381-MIB;

          x25     OBJECT IDENTIFIER ::= { transmission 5 }

          -- Support of the X25 subtree and all subtrees under it
          -- is mandatory for all agents of system that implement X.25.

          X121Address ::= OCTET STRING (SIZE(0..17))
           -- 0 to 17 bytes in length containing the ASCII
           -- characters [0-9], each octet contains one digit
           -- of the address.

          -- ###########################################################
          --            X.25 Administration Table
          -- ###########################################################

          x25AdmnTable OBJECT-TYPE


                  SYNTAX  SEQUENCE OF X25AdmnEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "This table contains the administratively
                          set configuration parameters for an X.25
                          Packet Level Entity (PLE).

                         Most of the objects in this table have
                          corresponding objects in the x25OperTable.
                          This table contains the values as last set
                          by the administrator.  The x25OperTable
                          contains the values actually in use by an
                          X.25 PLE.

                          Changing an administrative value may or may
                          not change a current operating value.  The
                          operating value may not change until the
                          interface is restarted.  Some
                          implementations may change the values
                          immediately upon changing the administrative
                          table.  All implementations are required to
                          load the values from the administrative
                          table when initializing a PLE."
                  ::= { x25 1 }

          x25AdmnEntry OBJECT-TYPE
                  SYNTAX  X25AdmnEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25AdmnTable."
                  INDEX { x25AdmnIndex }
                  ::= { x25AdmnTable 1 }

          X25AdmnEntry ::= SEQUENCE {
                  x25AdmnIndex
                          IfIndexType,
                  x25AdmnInterfaceMode
                          INTEGER,
                  x25AdmnMaxActiveCircuits
                          INTEGER,
                  x25AdmnPacketSequencing
                          INTEGER,
                  x25AdmnRestartTimer
                          PositiveInteger,
               x25AdmnCallTimer
                          PositiveInteger,


                  x25AdmnResetTimer
                          PositiveInteger,
                  x25AdmnClearTimer
                          PositiveInteger,
                  x25AdmnWindowTimer
                          PositiveInteger,
                  x25AdmnDataRxmtTimer
                          PositiveInteger,
                  x25AdmnInterruptTimer
                          PositiveInteger,
                  x25AdmnRejectTimer
                          PositiveInteger,
                  x25AdmnRegistrationRequestTimer
                          PositiveInteger,
                  x25AdmnMinimumRecallTimer
                          PositiveInteger,
                  x25AdmnRestartCount
                          INTEGER,
                  x25AdmnResetCount
                          INTEGER,
                  x25AdmnClearCount
                          INTEGER,
                  x25AdmnDataRxmtCount
                          INTEGER,
                  x25AdmnRejectCount
                          INTEGER,
                  x25AdmnRegistrationRequestCount
                          INTEGER,
                  x25AdmnNumberPVCs
                          INTEGER,
                  x25AdmnDefCallParamId
                          OBJECT IDENTIFIER,
                  x25AdmnLocalAddress
                          X121Address,
                  x25AdmnProtocolVersionSupported
                          OBJECT IDENTIFIER
                  }

          x25AdmnIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The ifIndex value for the X.25 Interface."
                  ::= { x25AdmnEntry 1 }

          x25AdmnInterfaceMode OBJECT-TYPE
                  SYNTAX  INTEGER {


                                  dte (1),
                                  dce (2),
                                  dxe (3)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Identifies DCE/DTE mode in which the
                          interface operates.  A value of dxe
                          indicates the mode will be determined by XID
                          negotiation."
                  REFERENCE "10733 5.9 interfaceMode"
                  ::= { x25AdmnEntry 2 }

          x25AdmnMaxActiveCircuits        OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The maximum number of circuits this PLE can
                          support; including PVCs."
                  REFERENCE "10733 5.9 maxActiveCircuits;
                          See ISO 8208, Section 3.7"
                  ::= { x25AdmnEntry 3 }

          x25AdmnPacketSequencing OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  modulo8 (1),
                                  modulo128 (2)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The modulus of the packet sequence number
                          space."
                  REFERENCE "10733 extendedPacketSequencing;
                          See ISO 8208 Section 7.1.1"
                  ::= { x25AdmnEntry 4 }

          x25AdmnRestartTimer OBJECT-TYPE
               SYNTAX     PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T20 restart timer in milliseconds."
                  REFERENCE "10733 5.9 restartTime
                          See ISO 8208 Section 4.1, table 26"
                  ::= { x25AdmnEntry 5 }


          x25AdmnCallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T21 Call timer in milliseconds."
                  REFERENCE "10733 callTime;
                          See ISO 8208 Section 5.2.1, table 26"
                  ::= { x25AdmnEntry 6 }

          x25AdmnResetTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T22 Reset timer in milliseconds."
                  REFERENCE "10733 resetTime;
                          See ISO 8208 Section 8.1, table 26"
                  ::= { x25AdmnEntry 7 }

          x25AdmnClearTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T23 Clear timer in milliseconds."
                  REFERENCE "10733 clearTime;
                          See ISO 8208 Section 5.5.1, table 26"
                  ::= { x25AdmnEntry 8 }

          x25AdmnWindowTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T24 window status transmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no window timer in use."
                  REFERENCE "10733 5.10.1 windowTime (opt);
                          See ISO 8208 Section 11.2.2, table 26"
                  ::= { x25AdmnEntry 9 }

          x25AdmnDataRxmtTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T25 data retransmission timer in


                          milliseconds.  A value of 2147483647
                          indicates no data retransmission timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
                          See ISO 8208 Section 11.2.1, table 26"
                  ::= { x25AdmnEntry 10 }

          x25AdmnInterruptTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T26 interrupt timer in milliseconds.  A
                          value of 2147483647 indicates no interrupt
                          timer in use."
                  REFERENCE "10733 interruptTime;
                          See ISO 8208 Section 6.8.1, table 26"
                  ::= { x25AdmnEntry 11 }

          x25AdmnRejectTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T27 Reject retransmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no reject timer in use."
                  REFERENCE "10733 5.10.1 dataRejectTime (opt);
                          See ISO 8208 Section 13.4.1, table 26"
                  ::= { x25AdmnEntry 12 }

          x25AdmnRegistrationRequestTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The T28 registration timer in milliseconds.
                          A value of 2147483647 indicates no
                          registration timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestTime (opt)
                          See ISO 8208    Section 13.1.1.1, table 26"
                  ::= { x25AdmnEntry 13 }

          x25AdmnMinimumRecallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION


                          "Minimum time interval between unsuccessful
                          call attempts in milliseconds."
                  REFERENCE "10733 5.9 minimum RecallTimer"
                  ::= { x25AdmnEntry 14 }

          x25AdmnRestartCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R20 restart retransmission count."
                  REFERENCE "10733 5.9 restartCount;
                          See ISO 8208    Section 4.1, table 27"
                  ::= { x25AdmnEntry 15 }

          x25AdmnResetCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The r22 Reset retransmission count."
                  REFERENCE "10733 resetCount;
                          See section ISO 8208 8.1, table 27"
                  ::= { x25AdmnEntry 16 }

          x25AdmnClearCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                  "The r23 Clear retransmission count."
                  REFERENCE "10733 clearCount;
                          See ISO 8208 Section 5.5.1, table 27"
                  ::= { x25AdmnEntry 17 }

          x25AdmnDataRxmtCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R25 Data retransmission count.  This
                          value is irrelevant if the
                          x25AdmnDataRxmtTimer indicates no timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionCount (opt)
                          See ISO 8208 Section 11.2.1, table 27"
                  ::= { x25AdmnEntry 18 }


          x25AdmnRejectCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R27 reject retransmission count.  This
                          value is irrelevant if the
                          x25AdmnRejectTimer indicates no timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRejectCount (opt)"
                  ::= { x25AdmnEntry 19 }

          x25AdmnRegistrationRequestCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The R28 Registration retransmission Count.
                          This value is irrelevant if the
                          x25AdmnRegistrationRequestTimer indicates no
                          timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestCount (opt);
                          See ISO 8208    Section 13.1.1.1, table 27"
                  ::= { x25AdmnEntry 20 }

          x25AdmnNumberPVCs OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PVC configured for this PLE.
                          The PVCs use channel numbers from 1 to this
                          number."
                  ::= { x25AdmnEntry 21 }

          x25AdmnDefCallParamId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the
                          x25CallParmIndex for the entry in the
                          x25CallParmTable which contains the default
                          call parameters for this PLE."
                  ::= { x25AdmnEntry 22 }

          x25AdmnLocalAddress OBJECT-TYPE
                  SYNTAX  X121Address


                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The local address for this PLE subnetwork.
                          A zero length address maybe returned by PLEs
                          that only support PVCs."
                  REFERENCE "10733 5.9 localDTEAddress"
                  ::= { x25AdmnEntry 23 }

          x25AdmnProtocolVersionSupported OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Identifies the version of the X.25 protocol
                          this interface should support.  Object
                          identifiers for common versions are defined
                          below in the x25ProtocolVersion subtree."
                  REFERENCE "10733 5.9 protocolVersionSupported"
                  ::= { x25AdmnEntry 24 }

          -- ###########################################################
          --            X.25 Operational Table
          -- ###########################################################

          x25OperTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25OperEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "The operation parameters in use by the X.25
                          PLE."
                  ::= { x25 2 }

          x25OperEntry OBJECT-TYPE
                  SYNTAX  X25OperEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25OperTable."
                  INDEX { x25OperIndex }
                  ::= { x25OperTable 1 }

          X25OperEntry ::= SEQUENCE {
                  x25OperIndex
                          IfIndexType,
                  x25OperInterfaceMode


                          INTEGER,
                  x25OperMaxActiveCircuits
                          INTEGER,
                  x25OperPacketSequencing
                          INTEGER,
                  x25OperRestartTimer
                          PositiveInteger,
                  x25OperCallTimer
                          PositiveInteger,
                  x25OperResetTimer
                          PositiveInteger,
                  x25OperClearTimer
                          PositiveInteger,
                  x25OperWindowTimer
                          PositiveInteger,
                  x25OperDataRxmtTimer
                          PositiveInteger,
                  x25OperInterruptTimer
                          PositiveInteger,
                  x25OperRejectTimer
                          PositiveInteger,
               x25OperRegistrationRequestTimer
                          PositiveInteger,
                  x25OperMinimumRecallTimer
                          PositiveInteger,
                  x25OperRestartCount
                          INTEGER,
                  x25OperResetCount
                          INTEGER,
                  x25OperClearCount
                          INTEGER,
                  x25OperDataRxmtCount
                          INTEGER,
                  x25OperRejectCount
                          INTEGER,
                  x25OperRegistrationRequestCount
                          INTEGER,
                  x25OperNumberPVCs
                          INTEGER,
                  x25OperDefCallParamId
                          OBJECT IDENTIFIER,
                  x25OperLocalAddress
                          X121Address,
                  x25OperDataLinkId
                          OBJECT IDENTIFIER,
                  x25OperProtocolVersionSupported
                          OBJECT IDENTIFIER
                  }


          x25OperIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 interface."
                  ::= { x25OperEntry 1 }

          x25OperInterfaceMode OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  dte (1),
                                  dce (2),
                                  dxe (3)
                          }
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "Identifies DCE/DTE mode in which the
                          interface operates.  A value of dxe
                          indicates the role will be determined by XID
                          negotiation at the Link Layer and that
                          negotiation has not yet taken place."
                  REFERENCE "10733 5.9 interfaceMode"
                  ::= { x25OperEntry 2 }

          x25OperMaxActiveCircuits        OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "Maximum number of circuits this PLE can
                          support."
                  REFERENCE "10733 5.9 maxActiveCircuits
                          See ISO 8208, Section 3.7"
                  ::= { x25OperEntry 3 }

          x25OperPacketSequencing OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  modulo8 (1),
                                  modulo128 (2)
                          }
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The modulus of the packet sequence number
                          space."
                  REFERENCE "10733 extendedPacketSequencing;
                          See ISO 8208    Section 7.1.1"


                  ::= { x25OperEntry 4 }

          x25OperRestartTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T20 restart timer in milliseconds."
                  REFERENCE "10733 5.9 restartTime;
                          See ISO 8208    Section 4.1, table 26"
                  ::= { x25OperEntry 5 }

          x25OperCallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T21 Call timer in milliseconds."
                  REFERENCE "10733 callTime;
                          See ISO 8208 Section 5.2.1, table 26"
                  ::= { x25OperEntry 6 }

          x25OperResetTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T22 Reset timer in milliseconds."
                  REFERENCE "10733 resetTime;
                          See ISO 8208    Section 8.1, table 26"
                  ::= { x25OperEntry 7 }

          x25OperClearTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T23 Clear timer in milliseconds."
                  REFERENCE "10733 clearTime;
                          See ISO 8208 Section 5.5.1, table 26"
                  ::= { x25OperEntry 8 }

          x25OperWindowTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T24 window status transmission timer


                          milliseconds.  A value of 2147483647
                          indicates no window timer in use."
                  REFERENCE "10733 5.10.1 windowTime (opt);
                          See ISO 8208 Section 11.2.2, table 26"
                  ::= { x25OperEntry 9 }

          x25OperDataRxmtTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T25 Data Retransmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no data retransmission timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
                          See ISO 8208 Section 11.2.1, table 26"
                  ::= { x25OperEntry 10 }

          x25OperInterruptTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T26 Interrupt timer in milliseconds.  A
                          value of 2147483647 indicates interrupts are
                          not being used."
                  REFERENCE "10733 interruptTime;
                          See ISO 8208 Section 6.8.1, table 26"
                  ::= { x25OperEntry 11 }

          x25OperRejectTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The T27 Reject retransmission timer in
                          milliseconds.  A value of 2147483647
                          indicates no reject timer in use."
                  REFERENCE "10733 5.10.1 dataRejectTime (opt);
                          See ISO 8208 Section 13.4.1, table 26"
                  ::= { x25OperEntry 12 }

          x25OperRegistrationRequestTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION


                          "The T28 registration timer in milliseconds.
                          A value of 2147483647 indicates no
                          registration timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestTime (opt);
                          See ISO 8208    Section 13.1.1.1, table 26"
                  ::= { x25OperEntry 13 }

          x25OperMinimumRecallTimer OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "Minimum time interval between unsuccessful
                          call attempts in milliseconds."
                  REFERENCE "10733 5.9 minimum RecallTimer"
                  ::= { x25OperEntry 14 }

          x25OperRestartCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R20 restart retransmission count."
                  REFERENCE "10733 5.9 restartCount
                          See ISO 8208    Section 4.1, table 27"
                  ::= { x25OperEntry 15 }

          x25OperResetCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The r22 Reset retransmission count."
                  REFERENCE "10733 resetCount;
                          See section ISO 8208 8.1, table 27"
                  ::= { x25OperEntry 16 }

          x25OperClearCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The r23 Clear retransmission count."
                  REFERENCE "10733 clearCount;
                          See ISO 8208 Section 5.5.1, table 27"
                  ::= { x25OperEntry 17 }

          x25OperDataRxmtCount OBJECT-TYPE


                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R25 Data retransmission count.  This
                          value is undefined if the
                          x25OperDataRxmtTimer indicates no timer in
                          use."
                  REFERENCE "10733 5.10.1 dataRetransmissionCount (opt);
                          See ISO 8208 Section 11.2.1, table 27"
                  ::= { x25OperEntry 18 }

          x25OperRejectCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R27 reject retransmission count.  This
                          value is undefined if the x25OperRejectTimer
                          indicates no timer in use."
                  REFERENCE "10733 5.10.1 dataRejectCount (opt)"
                  ::= { x25OperEntry 19 }

          x25OperRegistrationRequestCount OBJECT-TYPE
                  SYNTAX  INTEGER (0..65535)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The R28 Registration retransmission Count.
                          This value is undefined if the
                          x25OperREgistrationRequestTimer indicates no
                          timer in use."
                  REFERENCE "10733 5.8.1 registrationRequestCount (opt);
                          See ISO 8208    Section 13.1.1.1, table 27"
                  ::= { x25OperEntry 20 }

          x25OperNumberPVCs OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PVC configured for this PLE.
                          The PVCs use channel numbers from 1 to this
                          number."
                  ::= { x25OperEntry 21 }

          x25OperDefCallParamId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER


                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the
                          x25CallParmIndex for the entry in the
                          x25CallParmTable that contains the default
                          call parameters for this PLE."
                  ::= { x25OperEntry 22 }

          x25OperLocalAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The local address for this PLE subnetwork.
                          A zero length address maybe returned by PLEs
                          that only support PVCs."
                  REFERENCE "10733 5.9 localDTEAddress"
                  ::= { x25OperEntry 23 }

          x25OperDataLinkId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the index
                          object in the first table of the most device
                          specific MIB for the interface used by this
                          PLE."
                  ::= { x25OperEntry 24 }

          x25OperProtocolVersionSupported OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "Identifies the version of the X.25 protocol
                          this interface supports.  Object identifiers
                          for common versions are defined below in the
                          x25ProtocolVersion subtree."
                  REFERENCE "10733 5.9 protocolVersionSupported"
                  ::= { x25OperEntry 25 }

          --      MIB-II also provides:

          -- ifDescr:
          -- On an X.25 interface this must include sufficient


          -- information to enable the system's administrator
          -- to determine the appropriate configuration
          -- information on a system having multiple X.25
          -- subnetworks.

          -- ifType: ddn-x25 or rfc877-x25
          --      an interface of type ddn-x25 will use an algorithm to
          --      translate between X.121 address and IP addresses.
          --      An interface of type rfc877-x25 will use a
          --      configuration table to translate between X.121
          --      addresses and IP addresses.

          -- ifMtu: the maximum PDU a higher layer can pass to X.25 or
          -- receive from X.25

          -- ifSpeed:
          -- This will be the value of the local clock for this line.
          -- A value of zero indicates external clocking.

          -- ifAdminStatus:

          -- ifOperStatus

          -- ifLastChange

          -- ###########################################################
          --            X.25 Statistics Table
          -- ###########################################################

          x25StatTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25StatEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Statistics information about this X.25
                          PLE."
                  ::= { x25 3 }

          x25StatEntry OBJECT-TYPE
                  SYNTAX  X25StatEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                           "Entries of the x25StatTable."
                           INDEX { x25StatIndex }
                  ::= { x25StatTable 1 }


          X25StatEntry ::= SEQUENCE {
                  x25StatIndex
                          IfIndexType,
                  x25StatInCalls
                          Counter,
                  x25StatInCallRefusals
                          Counter,
                  x25StatInProviderInitiatedClears
                          Counter,
                  x25StatInRemotelyInitiatedResets
                          Counter,
                  x25StatInProviderInitiatedResets
                          Counter,
                  x25StatInRestarts
                          Counter,
                  x25StatInDataPackets
                          Counter,
                  x25StatInAccusedOfProtocolErrors
                          Counter,
                  x25StatInInterrupts
                          Counter,
                  x25StatOutCallAttempts
                          Counter,
                  x25StatOutCallFailures
                          Counter,
                  x25StatOutInterrupts
                          Counter,
                  x25StatOutDataPackets
                          Counter,
                  x25StatOutgoingCircuits
                          Gauge,
                  x25StatIncomingCircuits
                          Gauge,
                  x25StatTwowayCircuits
                          Gauge,
                  x25StatRestartTimeouts
                          Counter,
                  x25StatCallTimeouts
                          Counter,
                  x25StatResetTimeouts
                          Counter,
                  x25StatClearTimeouts
                          Counter,
                  x25StatDataRxmtTimeouts
                          Counter,
                  x25StatInterruptTimeouts
                          Counter,
                  x25StatRetryCountExceededs


                          Counter,
                  x25StatClearCountExceededs
                          Counter
                  }

          x25StatIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 interface."
                  ::= { x25StatEntry 1 }

          x25StatInCalls OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of incoming calls received."
                  ::= { x25StatEntry 2 }

          x25StatInCallRefusals OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of incoming calls refused.  This
                          includes calls refused by the PLE and by
                          higher layers.  This also includes calls
                          cleared because of restricted fast select."
                  ::= { x25StatEntry 3 }

          x25StatInProviderInitiatedClears        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of clear requests with a cause
                          code other than DTE initiated."
                          REFERENCE "10733 providerInitiatedDisconnect"
                  ::= { x25StatEntry 4 }

          x25StatInRemotelyInitiatedResets        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of reset requests received with


                          cause code DTE initiated."
                  REFERENCE "10733 remotelyInitiatedResets"
                  ::= { x25StatEntry 5 }

          x25StatInProviderInitiatedResets        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of reset requests received with
                          cause code other than DTE initiated."
                  REFERENCE "10733 ProviderInitiatedResets"
                  ::= { x25StatEntry 6 }

          x25StatInRestarts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of remotely initiated (including
                          provider initiated) restarts experienced by
                          the PLE excluding the restart associated
                          with bringing up the PLE interface.  This
                          only counts restarts received when the PLE
                          already has an established connection with
                          the remove PLE."
                  REFERENCE "10733 5.9 remotelyInitiatedRestarts"
                  ::= { x25StatEntry 7 }

          x25StatInDataPackets    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of data packets received."
                          REFERENCE "10733 5.9 dataPacketsReceived."
                  ::= { x25StatEntry 8 }

          x25StatInAccusedOfProtocolErrors        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of packets received containing a
                          procedure error cause code.  These include
                          clear, reset, restart, or diagnostic
                          packets."
                  REFERENCE "CD 10733 5.9 accusedOfProtocolError"


                  ::= { x25StatEntry 9 }

          x25StatInInterrupts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets received by
                          the PLE or over the PVC/VC."
                  REFERENCE "10733 interruptPacketsReceived"
                  ::= { x25StatEntry 10 }

          x25StatOutCallAttempts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of calls attempted."
                  REFERENCE "10733 5.9 callAttempts"
                  ::= { x25StatEntry 11 }

          x25StatOutCallFailures OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of call attempts which failed.
                          This includes calls that were cleared
                          because of restrictive fast select."
                  ::= { x25StatEntry 12 }

          x25StatOutInterrupts    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets send by the
                          PLE or over the PVC/VC."
                  REFERENCE "10733 InterruptPacketsSent"
                  ::= { x25StatEntry 13 }

          x25StatOutDataPackets   OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of data packets sent by this
                          PLE."


                  REFERENCE "10733 dataPacketSent"
                  ::= { x25StatEntry 14 }

          x25StatOutgoingCircuits OBJECT-TYPE
                  SYNTAX  Gauge
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of active outgoing circuits.
                          This includes call requests sent but not yet
                          confirmed.  This does not count PVCs."
                  ::= { x25StatEntry 15 }

          x25StatIncomingCircuits OBJECT-TYPE
                  SYNTAX  Gauge
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of active Incoming Circuits.
                          This includes call indications received but
                          not yet acknowledged.  This does not count
                          PVCs."
                  ::= { x25StatEntry 16 }

          x25StatTwowayCircuits   OBJECT-TYPE
                  SYNTAX  Gauge
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                  "The number of active two-way Circuits.
                          This includes call requests sent but not yet
                          confirmed.  This does not count PVCs."
                  ::= { x25StatEntry 17 }

          x25StatRestartTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T20 restart timer
                          expired."
                  REFERENCE "10733 5.9 restartTimeouts"
                  ::= { x25StatEntry 18 }

          x25StatCallTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory


                  DESCRIPTION
                          "The number of times the T21 call timer
                          expired."
                  REFERENCE "10733 5.9 callTimeouts"
                  ::= { x25StatEntry 19 }

          x25StatResetTimeouts    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T22 reset timer
                          expired."
                  REFERENCE "10733 5.9 resetTimeouts"
                  ::= { x25StatEntry 20 }

          x25StatClearTimeouts    OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T23 clear timer
                          expired."
                  REFERENCE "10733 5.9 clearTimeouts"
                  ::= { x25StatEntry 21 }

          x25StatDataRxmtTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T25 data timer
                          expired."
                  REFERENCE "10733 5.9 dataRetransmissionsTimerExpiries"
                  ::= { x25StatEntry 22 }

          x25StatInterruptTimeouts        OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T26 interrupt timer
                          expired."
                  REFERENCE "10733 5.9 interruptTimerExpires"
                  ::= { x25StatEntry 23 }

          x25StatRetryCountExceededs OBJECT-TYPE
                  SYNTAX  Counter


                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times a retry counter was
                          exhausted."
                  REFERENCE "10733 5.9 retryCountsExceeded"
                  ::= { x25StatEntry 24 }

          x25StatClearCountExceededs OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the R23 clear count was
                          exceeded."
                  REFERENCE "10733 5.9 clearCountsExceeded"
                  ::= { x25StatEntry 25 }

          --      MIB-II also contains:

          -- ifInOctets: Number of data octets delivered to upper
          -- layer entities.

          -- ifInUcastPkts: Number of packets with a clear M-bit
          -- delivered to higher layer entities.

          -- ifDiscards: Number of packets dropped for lack of buffering

          -- ifInErrors: Number of packets received containing errors
            -- REFERENCE ProtocolErrorsDetectedLocally

          -- ifInUnknownProtos: Number of packets with unknown circuit
          -- identifier.

          -- ifOutOctets: Number of data octets delivered by
          --      X.25 to upper layers.

          -- ifOutUcastPkts: Number of packets with a clear M-bit
          -- received from higher layer entities.

          -- ###########################################################
          --                    X.25 Channel Table
          -- ###########################################################

          x25ChannelTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25ChannelEntry


                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "These objects contain information about the
                          channel number configuration in an X.25 PLE.
                          These values are the configured values.
                          changes in these values after the interfaces
                          has started may not be reflected in the
                          operating PLE."
                  REFERENCE "See ISO 8208, Section 3.7"
                  ::= { x25 4 }

          x25ChannelEntry OBJECT-TYPE
                  SYNTAX  X25ChannelEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25ChannelTable."
                  REFERENCE "This provides the information available
                          in 10733 logicalChannelAssignments."
                  INDEX { x25ChannelIndex }
                  ::= { x25ChannelTable 1    }

          X25ChannelEntry ::= SEQUENCE {
                  x25ChannelIndex
                          IfIndexType,
                  x25ChannelLIC
                          INTEGER,
                  x25ChannelHIC
                          INTEGER,
                  x25ChannelLTC
                          INTEGER,
                  x25ChannelHTC
                          INTEGER,
                  x25ChannelLOC
                          INTEGER,
                  x25ChannelHOC
                          INTEGER
                  }

          x25ChannelIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 Interface."
                  ::= { x25ChannelEntry 1 }


          x25ChannelLIC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Lowest Incoming channel."
                  ::= { x25ChannelEntry 2 }

          x25ChannelHIC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Highest Incoming channel.  A value of zero
                          indicates no channels in this range."
                  ::= { x25ChannelEntry 3 }

          x25ChannelLTC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Lowest Two-way channel."
                  ::= { x25ChannelEntry 4 }

          x25ChannelHTC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Highest Two-way channel.  A value of zero
                          indicates no channels in this range."
                  ::= { x25ChannelEntry 5 }

          x25ChannelLOC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Lowest outgoing channel."
                  ::= { x25ChannelEntry 6 }

          x25ChannelHOC OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Highest outgoing channel.  A value of zero


                          indicates no channels in this range."
                  ::= { x25ChannelEntry 7 }

          -- ###########################################################
          --          X25 Per Circuits Information Table
          -- ###########################################################

          x25CircuitTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25CircuitEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "These objects contain general information
                          about a specific circuit of an X.25 PLE."
                  ::= { x25 5 }

          x25CircuitEntry OBJECT-TYPE
                  SYNTAX  X25CircuitEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25CircuitTable."
                  INDEX { x25CircuitIndex,
                          x25CircuitChannel }
                  ::= { x25CircuitTable 1 }

          X25CircuitEntry ::= SEQUENCE {
                  x25CircuitIndex
                          IfIndexType,
                  x25CircuitChannel
                          INTEGER,
                  x25CircuitStatus
                          INTEGER,
                  x25CircuitEstablishTime
                          TimeTicks,
                  x25CircuitDirection
                          INTEGER,
                  x25CircuitInOctets
                          Counter,
                  x25CircuitInPdus
                          Counter,
                  x25CircuitInRemotelyInitiatedResets
                          Counter,
                  x25CircuitInProviderInitiatedResets
                          Counter,


                  x25CircuitInInterrupts
                          Counter,
                  x25CircuitOutOctets
                          Counter,
                  x25CircuitOutPdus
                          Counter,
                  x25CircuitOutInterrupts
                          Counter,
                  x25CircuitDataRetransmissionTimeouts
                          Counter,
                  x25CircuitResetTimeouts
                          Counter,
                  x25CircuitInterruptTimeouts
                          Counter,
                  x25CircuitCallParamId
                          OBJECT IDENTIFIER,
                  x25CircuitCalledDteAddress
                          X121Address,
                  x25CircuitCallingDteAddress
                          X121Address,
                  x25CircuitOriginallyCalledAddress
                          X121Address,
                  x25CircuitDescr
                          DisplayString
                  }

          x25CircuitIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The ifIndex value for the X.25 Interface."
                  ::= { x25CircuitEntry 1 }

          x25CircuitChannel OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The channel number for this circuit."
                  ::= { x25CircuitEntry 2 }

          x25CircuitStatus OBJECT-TYPE
                  SYNTAX  INTEGER {               -- state table states
                                  invalid (1),
                                  closed (2),             -- (p1)
                                  calling (3),            -- (p2,p3,p5)
                                  open (4),               -- (p4)


                                  clearing (5),           -- (p6,p7)
                                  pvc (6),
                                  pvcResetting (7),
                                  startClear (8),         -- Close cmd
                                  startPvcResetting (9),  -- Reset cmd
                                  other (10)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "This object reports the current status of
                          the circuit.

                          An existing instance of this object can only
                          be set to startClear, startPvcResetting, or
                          invalid.  An instance with the value calling
                          or open can only be set to startClear and
                          that action will start clearing the circuit.
                          An instance with the value PVC can only be
                          set to startPvcResetting or invalid and that
                          action resets the PVC or deletes the circuit
                          respectively.  The values startClear or
                          startPvcResetting will never be returned by
                          an agent.  An attempt to set the status of
                          an existing instance to a value other than
                          one of these values will result in an error.

                          A non-existing instance can be set to PVC to
                          create a PVC if the implementation supports
                          dynamic creation of PVCs.  Some
                          implementations may only allow creation and
                          deletion of PVCs if the interface is down.
                          Since the instance identifier will supply
                          the PLE index and the channel number,
                          setting this object alone supplies
                          sufficient information to create the
                          instance.  All the DEFVAL clauses for the
                          other objects of this table are appropriate
                          for creating a PVC; PLEs creating entries
                          for placed or accepted calls will use values
                          appropriate for the call rather than the
                          value of the DEFVAL clause.  Two managers
                          trying to create the same PVC can determine
                          from the return code which manager succeeded
                          and which failed (the failing manager fails
                          because it can not set a value of PVC for an
                          existing object).


                          An entry in the closed or invalid state may
                          be deleted or reused at the agent's
                          convence.  If the entry is kept in the
                          closed state, the values of the parameters
                          associated with the entry must be correct.
                          Closed implies the values in the circuit
                          table are correct.

                          The value of invalid indicates the other
                          values in the table are invalid.  Many
                          agents may never return a value of invalid
                          because they dynamically allocate and free
                          unused table entries.  An agent for a
                          statically configured systems can return
                          invalid to indicate the entry has not yet
                          been used so the counters contain no
                          information."
                  REFERENCE "See ISO 8208,
                                  table 33 for (p<n>) state table"
                  ::= { x25CircuitEntry 3 }

          x25CircuitEstablishTime OBJECT-TYPE
                  SYNTAX  TimeTicks
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The value of sysUpTime when the channel was
                          associated with this circuit.  For outgoing
                          SVCs, this is the time the first call packet
                          was sent.  For incoming SVCs, this is the
                          time the call indication was received.  For
                          PVCs this is the time the PVC was able to
                          pass data to a higher layer entity without
                          loss of data."
                  ::= { x25CircuitEntry 4 }

          x25CircuitDirection OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  incoming (1),
                                  outgoing (2),
                                  pvc (3)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The direction of the call that established
                          this circuit."
                  REFERENCE "10733 direction"


                  DEFVAL { pvc }
                  ::= { x25CircuitEntry 5 }

                          -- X25 Circuit data flow statistics

          x25CircuitInOctets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of octets of user data delivered
                          to upper layer."
                  REFERENCE "5.11 octetsReceivedCounter"
                  ::= { x25CircuitEntry 6 }

          x25CircuitInPdus OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PDUs received for this
                          circuit."
                  REFERENCE "10733 5.11 dataPacketsReceived"
                  ::= { x25CircuitEntry 7 }

          x25CircuitInRemotelyInitiatedResets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of Resets received for this
                          circuit with cause code of DTE initiated."
                  REFERENCE "10733 remotelyInitiatedResets"
                  ::= { x25CircuitEntry 8 }

          x25CircuitInProviderInitiatedResets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of Resets received for this
                          circuit with cause code other than DTE
                          initiated."
                  REFERENCE "10733 ProviderInitiatedResets"
                  ::= { x25CircuitEntry 9 }

          x25CircuitInInterrupts OBJECT-TYPE
                  SYNTAX  Counter


                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets received
                          for this circuit."
                  REFERENCE "10733 interruptPacketsReceived"
                  ::= { x25CircuitEntry 10 }

          x25CircuitOutOctets OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of octets of user data sent for
                          this circuit."
                  REFERENCE "10733 5.11 octetsSentCounter"
                  ::= { x25CircuitEntry 11 }

          x25CircuitOutPdus OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PDUs sent for this circuit."
                  REFERENCE "10733 5.11 dataPacketsSent"
                  ::= { x25CircuitEntry 12 }

          x25CircuitOutInterrupts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of interrupt packets sent on
                          this circuit."
                  REFERENCE "10733 interruptPacketsSent"
                  ::= { x25CircuitEntry 13 }

                          -- X25 circuit timer statistics

          x25CircuitDataRetransmissionTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T25 data
                          retransmission timer expired for this
                          circuit."


                  REFERENCE "10733 5.11 dataRetransmissionTimerExpiries"
                  ::= { x25CircuitEntry 14 }

          x25CircuitResetTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T22 reset timer
                          expired for this circuit."
                  REFERENCE "10733 5.11 resetTimeouts"
                  ::= { x25CircuitEntry 15 }

          x25CircuitInterruptTimeouts OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of times the T26 Interrupt timer
                          expired for this circuit."
                  REFERENCE "10733 interruptTimerExpiries"
                  ::= { x25CircuitEntry 16 }

          x25CircuitCallParamId OBJECT-TYPE
                  SYNTAX  OBJECT IDENTIFIER
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "This identifies the instance of the
                          x25CallParmIndex for the entry in the
                          x25CallParmTable which contains the call
                          parameters in use with this circuit.  The
                          entry referenced must contain the values
                          that are currently in use by the circuit
                          rather than proposed values.  A value of
                          NULL indicates the circuit is a PVC or is
                          using all the default parameters."
                  DEFVAL { {0 0} }
                  ::= { x25CircuitEntry 17 }

          x25CircuitCalledDteAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "For incoming calls, this is the called
                          address from the call indication packet.
                          For outgoing calls, this is the called


                          address from the call confirmation packet.
                          This will be zero length for PVCs."
                  REFERENCE "10733 calledDTEAddress"
                  DEFVAL { ''h }
                  ::= { x25CircuitEntry 18 }

          x25CircuitCallingDteAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "For incoming calls, this is the calling
                          address from the call indication packet.
                          For outgoing calls, this is the calling
                          address from the call confirmation packet.
                          This will be zero length for PVCs."
                  REFERENCE "10733 callingDTEAddress"
                  DEFVAL { ''h }
                  ::= { x25CircuitEntry 19 }

          x25CircuitOriginallyCalledAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "For incoming calls, this is the address in
                          the call Redirection or Call Deflection
                          Notification facility if the call was
                          deflected or redirected, otherwise it will
                          be called address from the call indication
                          packet.  For outgoing calls, this is the
                          address from the call request packet.  This
                          will be zero length for PVCs."
                  REFERENCE "10733 originallyCalledAddress"
                  DEFVAL { ''h }
                  ::= { x25CircuitEntry 20 }

          x25CircuitDescr OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE (0..255))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "A descriptive string associated with this
                          circuit.  This provides a place for the
                          agent to supply any descriptive information
                          it knows about the use or owner of the
                          circuit.  The agent may return the process
                          identifier and user name for the process


                          using the circuit.  Alternative the agent
                          may return the name of the configuration
                          entry that caused a bridge to establish the
                          circuit.  A zero length value indicates the
                          agent doesn't have any additional
                          information."
                  DEFVAL { ''h }
                  ::= { x25CircuitEntry 21 }

          -- ###########################################################
          --              The Cleared Circuit Table
          -- ###########################################################

          x25ClearedCircuitEntriesRequested OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The requested number of entries for the
                          agent to keep in the x25ClearedCircuit
                          table."
                  ::= { x25 6 }

          x25ClearedCircuitEntriesGranted OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The actual number of entries the agent will
                          keep in the x25ClearedCircuit Table."
                  ::= { x25 7 }

          x25ClearedCircuitTable  OBJECT-TYPE
                  SYNTAX SEQUENCE OF      X25ClearedCircuitEntry
                  ACCESS not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "A table of entries about closed circuits.
                          Entries must be made in this table whenever
                          circuits are closed and the close request or
                          close indication packet contains a clearing
                          cause other than DTE Originated or a
                          Diagnostic code field other than Higher
                          Layer Initiated disconnection-normal.  An
                          agent may optionally make entries for normal
                          closes (to record closing facilities or


                          other information).

                          Agents will delete the oldest entry in the
                          table when adding a new entry would exceed
                          agent resources.  Agents are required to
                          keep the last entry put in the table and may
                          keep more entries.  The object
                          x25OperClearEntriesGranted returns the
                          maximum number of entries kept in the
                          table."
                  REFERENCE "See ISO 8208 Section 12.2.3.1.1
                                  and 12.2.3.1.2"
                  ::= { x25 8 }

          x25ClearedCircuitEntry  OBJECT-TYPE
                  SYNTAX  X25ClearedCircuitEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Information about a cleared circuit."
                  INDEX { x25ClearedCircuitIndex }
                  ::= { x25ClearedCircuitTable 1 }

          X25ClearedCircuitEntry ::= SEQUENCE {
                  x25ClearedCircuitIndex
                          PositiveInteger,
                  x25ClearedCircuitPleIndex
                          IfIndexType,
                  x25ClearedCircuitTimeEstablished
                          TimeTicks,
                  x25ClearedCircuitTimeCleared
                          TimeTicks,
                  x25ClearedCircuitChannel
                          INTEGER,
                  x25ClearedCircuitClearingCause
                          INTEGER,
                  x25ClearedCircuitDiagnosticCode
                          INTEGER,
                  x25ClearedCircuitInPdus
                          Counter,
                  x25ClearedCircuitOutPdus
                          Counter,
                  x25ClearedCircuitCalledAddress
                          X121Address,
                  x25ClearedCircuitCallingAddress
                          X121Address,
                  x25ClearedCircuitClearFacilities
                          OCTET STRING


                  }

          x25ClearedCircuitIndex OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "An index that uniquely distinguishes one
                          entry in the clearedCircuitTable from
                          another.  This index will start at
                          2147483647 and will decrease by one for each
                          new entry added to the table.  Upon reaching
                          one, the index will reset to 2147483647.
                          Because the index starts at 2147483647 and
                          decreases, a manager may do a getnext on
                          entry zero and obtain the most recent entry.
                          When the index has the value of 1, the next
                          entry will delete all entries in the table
                          and that entry will be numbered 2147483647."
                  ::= { x25ClearedCircuitEntry 1 }

          x25ClearedCircuitPleIndex OBJECT-TYPE
                  SYNTAX  IfIndexType
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The value of ifIndex for the PLE which
                          cleared the circuit that created the entry."
                  ::= { x25ClearedCircuitEntry 2 }

          x25ClearedCircuitTimeEstablished OBJECT-TYPE
                  SYNTAX  TimeTicks
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The value of sysUpTime when the circuit was
                          established.  This will be the same value
                          that was in the x25CircuitEstablishTime for
                          the circuit."
                  ::= { x25ClearedCircuitEntry 3 }

          x25ClearedCircuitTimeCleared OBJECT-TYPE
                  SYNTAX  TimeTicks
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The value of sysUpTime when the circuit was
                          cleared.  For locally initiated clears, this


                          will be the time when the clear confirmation
                          was received.  For remotely initiated
                          clears, this will be the time when the clear
                          indication was received."
                  ::= { x25ClearedCircuitEntry 4 }

          x25ClearedCircuitChannel OBJECT-TYPE
                  SYNTAX  INTEGER (0..4095)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The channel number for the circuit that was
                          cleared."
                  ::= { x25ClearedCircuitEntry 5 }

          x25ClearedCircuitClearingCause OBJECT-TYPE
                  SYNTAX  INTEGER (0..255)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The Clearing Cause from the clear request
                          or clear indication packet that cleared the
                          circuit."
                  REFERENCE "See ISO 8208 Section 12.2.3.1.1"
                  ::= { x25ClearedCircuitEntry 6 }

          x25ClearedCircuitDiagnosticCode OBJECT-TYPE
                  SYNTAX  INTEGER (0..255)
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The Diagnostic Code from the clear request
                          or clear indication packet that cleared the
                          circuit."
                  REFERENCE "See ISO 8208 Section 12.2.3.1.2"
                  ::= { x25ClearedCircuitEntry 7 }

          x25ClearedCircuitInPdus OBJECT-TYPE
                  SYNTAX  Counter
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PDUs received on the
                          circuit."
                  ::= { x25ClearedCircuitEntry 8 }

          x25ClearedCircuitOutPdus OBJECT-TYPE
                  SYNTAX  Counter


                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of PDUs transmitted on the
                          circuit."
                  ::= { x25ClearedCircuitEntry 9 }

          x25ClearedCircuitCalledAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The called address from the cleared
                          circuit."
                  ::= { x25ClearedCircuitEntry 10 }

          x25ClearedCircuitCallingAddress OBJECT-TYPE
                  SYNTAX  X121Address
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The calling address from the cleared
                          circuit."
                  ::= { x25ClearedCircuitEntry 11 }

          x25ClearedCircuitClearFacilities OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE (0..109))
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The facilities field from the clear request
                          or clear indication packet that cleared the
                          circuit.  A size of zero indicates no
                          facilities were present."
                  ::= { x25ClearedCircuitEntry 12 }

          -- ###########################################################
          --                The Call Parameter Table
          -- ###########################################################

          x25CallParmTable OBJECT-TYPE
                  SYNTAX  SEQUENCE OF X25CallParmEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION


                          "These objects contain the parameters that
                          can be varied between X.25 calls.  The
                          entries in this table are independent of the
                          PLE.  There exists only one of these tables
                          for the entire system.  The indexes for the
                          entries are independent of any PLE or any
                          circuit.  Other tables reference entries in
                          this table.  Entries in this table can be
                          used for default PLE parameters, for
                          parameters to use to place/answer a call,
                          for the parameters currently in use for a
                          circuit, or parameters that were used by a
                          circuit.

                          The number of references to a given set of
                          parameters can be found in the
                          x25CallParmRefCount object sharing the same
                          instance identifier with the parameters.
                          The value of this reference count also
                          affects the access of the objects in this
                          table.  An object in this table with the
                          same instance identifier as the instance
                          identifier of an x25CallParmRefCount must be
                          consider associated with that reference
                          count.  An object with an associated
                          reference count of zero can be written (if
                          its ACCESS clause allows it).  An object
                          with an associated reference count greater
                          than zero can not be written (regardless of
                          the ACCESS clause).  This ensures that a set
                          of call parameters being referenced from
                          another table can not be modified or changed
                          in a ways inappropriate for continued use by
                          that table."
                  ::= { x25 9 }

          x25CallParmEntry OBJECT-TYPE
                  SYNTAX  X25CallParmEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "Entries of x25CallParmTable."
                  INDEX { x25CallParmIndex }
                  ::= { x25CallParmTable 1 }

          X25CallParmEntry ::= SEQUENCE {
                  x25CallParmIndex
                          PositiveInteger,


                  x25CallParmStatus
                          EntryStatus,
                  x25CallParmRefCount
                          PositiveInteger,
                  x25CallParmInPacketSize
                          INTEGER,
                  x25CallParmOutPacketSize
                          INTEGER,
                  x25CallParmInWindowSize
                          INTEGER,
                  x25CallParmOutWindowSize
                          INTEGER,
                  x25CallParmAcceptReverseCharging
                          INTEGER,
                  x25CallParmProposeReverseCharging
                          INTEGER,
                  x25CallParmFastSelect
                          INTEGER,
                  x25CallParmInThruPutClasSize
                          INTEGER,
                  x25CallParmOutThruPutClasSize
                          INTEGER,
                  x25CallParmCug
                          DisplayString,
                  x25CallParmCugoa
                          DisplayString,
                  x25CallParmBcug
                          DisplayString,
                  x25CallParmNui
                          OCTET STRING,
                  x25CallParmChargingInfo
                          INTEGER,
                  x25CallParmRpoa
                          DisplayString,
                  x25CallParmTrnstDly
                          INTEGER,
                  x25CallParmCallingExt
                          DisplayString,
                  x25CallParmCalledExt
                          DisplayString,
                  x25CallParmInMinThuPutCls
                          INTEGER,
                  x25CallParmOutMinThuPutCls
                          INTEGER,
                  x25CallParmEndTrnsDly
                          OCTET STRING,
                  x25CallParmPriority
                          OCTET STRING,


                  x25CallParmProtection
                          DisplayString,
                  x25CallParmExptData
                          INTEGER,
                  x25CallParmUserData
                          OCTET STRING,
                  x25CallParmCallingNetworkFacilities
                          OCTET STRING,
                  x25CallParmCalledNetworkFacilities
                          OCTET STRING
                  }

          x25CallParmIndex OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "A value that distinguishes this entry from
                          another entry.  Entries in this table are
                          referenced from other objects which identify
                          call parameters.

                          It is impossible to know which other objects
                          in the MIB reference entries in the table by
                          looking at this table.  Because of this,
                          changes to parameters must be accomplished
                          by creating a new entry in this table and
                          then changing the referencing table to
                          identify the new entry.

                          Note that an agent will only use the values
                          in this table when another table is changed
                          to reference those values.  The number of
                          other tables that reference an index object
                          in this table can be found in
                          x25CallParmRefCount.  The value of the
                          reference count will affect the writability
                          of the objects as explained above.

                          Entries in this table which have a reference
                          count of zero maybe deleted at the convence
                          of the agent.  Care should be taken by the
                          agent to give the NMS sufficient time to
                          create a reference to newly created entries.

                          Should a Management Station not find a free
                          index with which to create a new entry, it
                          may feel free to delete entries with a


                          reference count of zero.  However in doing
                          so the Management Station much realize it
                          may impact other Management Stations."
                  ::= { x25CallParmEntry 1 }

          x25CallParmStatus OBJECT-TYPE
                  SYNTAX  EntryStatus
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The status of this call parameter entry.
                          See RFC 1271 for details of usage."
                  ::= { x25CallParmEntry 2 }

          x25CallParmRefCount OBJECT-TYPE
                  SYNTAX  PositiveInteger
                  ACCESS  read-only
                  STATUS  mandatory
                  DESCRIPTION
                          "The number of references know by a
                          management station to exist to this set of
                          call parameters.  This is the number of
                          other objects that have returned a value of,
                          and will return a value of, the index for
                          this set of call parameters.  Examples of
                          such objects are the x25AdmnDefCallParamId,
                          x25OperDataLinkId, or x25AdmnDefCallParamId
                          objects defined above."
                  ::= { x25CallParmEntry 3 }

          x25CallParmInPacketSize OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The maximum receive packet size in octets
                          for a circuit.  A size of zero for a circuit
                          means use the PLE default size.  A size of
                          zero for the PLE means use a default size of
                          128."
                  REFERENCE "10733 proposedPacketSize;
                          See ISO 8208 Section 15.2.2.1.1"
                  DEFVAL { 128 }
                  ::= { x25CallParmEntry 4 }

          x25CallParmOutPacketSize OBJECT-TYPE
                  SYNTAX  INTEGER (0..4096)
                  ACCESS  read-write


                  STATUS  mandatory
                  DESCRIPTION
                          "The maximum transmit packet size in octets
                          for a circuit.  A size of zero for a circuit
                          means use the PLE default size.  A size of
                          zero for the PLE default means use a default
                          size of 128."
                  REFERENCE "10733 proposedPacketSize;
                          See ISO 8208 Section 15.2.2.1.1"
                  DEFVAL { 128 }
                  ::= { x25CallParmEntry 5 }

          x25CallParmInWindowSize OBJECT-TYPE
                  SYNTAX  INTEGER (0..127)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The receive window size for a circuit.  A
                          size of zero for a circuit means use the PLE
                          default size.  A size of zero for the PLE
                          default means use 2."
                  REFERENCE "10733 proposedWindowSize;
                          See ISO 8208 Section 15.2.2.1.2"
                  DEFVAL { 2 }
                  ::= { x25CallParmEntry 6 }

          x25CallParmOutWindowSize OBJECT-TYPE
                  SYNTAX  INTEGER (0..127)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The transmit window size for a circuit.  A
                          size of zero for a circuit means use the PLE
                          default size.  A size of zero for the PLE
                          default means use 2."
                  REFERENCE "10733 proposedWindowSize;
                          See ISO 8208 Section 15.2.2.1.2"
                  DEFVAL { 2 }
                  ::= { x25CallParmEntry 7 }

          x25CallParmAcceptReverseCharging OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  default (1),
                                  accept (2),
                                  refuse (3),
                                  neverAccept (4)
                          }
                  ACCESS  read-write


                  STATUS  mandatory
                  DESCRIPTION
                          "An enumeration defining if the PLE will
                          accept or refuse charges.  A value of
                          default for a circuit means use the PLE
                          default value.  A value of neverAccept is
                          only used for the PLE default and indicates
                          the PLE will never accept reverse charging.
                          A value of default for a PLE default means
                          refuse."
                  REFERENCE "10733 acceptReverseCharging"
                  DEFVAL { refuse }
                  ::= { x25CallParmEntry 8 }

          x25CallParmProposeReverseCharging OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  default (1),
                                  reverse (2),
                                  local (3)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "An enumeration defining if the PLE should
                          propose reverse or local charging.  The
                          value of default for a circuit means use the
                          PLE default.  The value of default for the
                          PLE default means use local."
                  REFERENCE "10733 proposedPacketSize;
                          See ISO 8208 Section 15.2.2.6"
                  DEFVAL { local }
                  ::= { x25CallParmEntry 9 }

          x25CallParmFastSelect OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  default (1),
                                  notSpecified (2),
                                  fastSelect (3),
                                  restrictedFastResponse (4),
                                  noFastSelect (5),
                                  noRestrictedFastResponse (6)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "Expresses preference for use of fast select
                          facility.  The value of default for a
                          circuit is the PLE default.  A value of


                          default for the PLE means noFastSelect.  A
                          value of noFastSelect or
                          noRestrictedFastResponse indicates a circuit
                          may not use fast select or restricted fast
                          response."
                  REFERENCE "10733 fastSelect;
                  Sec ISO 8208 Section 15.2.2.6"
                  DEFVAL { noFastSelect }
                  ::= { x25CallParmEntry 10 }

          x25CallParmInThruPutClasSize    OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  tcReserved1 (1),
                                  tcReserved2 (2),
                                  tc75 (3),
                                  tc150 (4),
                                  tc300 (5),
                                  tc600 (6),
                                  tc1200  (7),
                                  tc2400  (8),
                                  tc4800  (9),
                                  tc9600  (10),
                                  tc19200 (11),
                                  tc48000 (12),
                                  tc64000 (13),
                                  tcReserved14 (14),
                                  tcReserved15 (15),
                                  tcReserved0 (16),
                                  tcNone  (17),
                                  tcDefault (18)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The incoming throughput class to negotiate.
                          A value of tcDefault for a circuit means use
                          the PLE default.  A value of tcDefault for
                          the PLE default means tcNone.  A value of
                          tcNone means do not negotiate throughtput
                          class."
                  REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
                  DEFVAL { tcNone }
                  ::= { x25CallParmEntry 11 }

          x25CallParmOutThruPutClasSize   OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  tcReserved1 (1),
                                  tcReserved2 (2),


                                  tc75 (3),
                                  tc150 (4),
                                  tc300 (5),
                          tc600 (6),
                                  tc1200  (7),
                                  tc2400  (8),
                                  tc4800  (9),
                                  tc9600  (10),
                                  tc19200 (11),
                                  tc48000 (12),
                                  tc64000 (13),
                                  tcReserved14 (14),
                                  tcReserved15 (15),
                                  tcReserved0 (16),
                                  tcNone  (17),
                                  tcDefault (18)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The outgoing throughput class to negotiate.
                          A value of tcDefault for a circuit means use
                          the PLE default.  A value of tcDefault for
                          the PLE default means use tcNone.  A value
                          of tcNone means do not negotiate throughtput
                          class."
                  REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
                  DEFVAL { tcNone }
                  ::= { x25CallParmEntry 12 }

          x25CallParmCug  OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE(0..4))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Closed User Group to specify.  This
                          consists of two or four octets containing
                          the characters 0 through 9.  A zero length
                          string indicates no facility requested.  A
                          string length of three containing the
                          characters DEF for a circuit means use the
                          PLE default, (the PLE default parameter may
                          not reference an entry of DEF.)"
                  REFERENCE "See ISO 8208 Section 15.2.2.3"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 13 }

          x25CallParmCugoa        OBJECT-TYPE


                  SYNTAX  DisplayString (SIZE(0..4))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Closed User Group with Outgoing Access
                          to specify.  This consists of two or four
                          octets containing the characters 0 through
                          9.  A string length of three containing the
                          characters DEF for a circuit means use the
                          PLE default (the PLE default parameters may
                          not reference an entry of DEF).  A zero
                          length string indicates no facility
                          requested."
                  REFERENCE "See ISO 8208 Section 15.2.2.4"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 14 }

          x25CallParmBcug OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE(0..3))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Bilateral Closed User Group to specify.
                          This consists of two octets containing the
                          characters 0 through 9.  A string length of
                          three containing the characters DEF for a
                          circuit means use the PLE default (the PLE
                          default parameter may not reference an entry
                          of DEF).  A zero length string indicates no
                          facility requested."
                  REFERENCE "See ISO 8208 Section 15.2.2.5"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 15 }

          x25CallParmNui  OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE(0..108))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Network User Identifier facility.  This
                          is binary value to be included immediately
                          after the length field.  The PLE will supply
                          the length octet.  A zero length string
                          indicates no facility requested.  This value
                          is ignored for the PLE default parameters
                          entry."
                  REFERENCE "See ISO 8208 Section 15.2.2.7"
                  DEFVAL { ''h }


                  ::= { x25CallParmEntry 16 }

          x25CallParmChargingInfo OBJECT-TYPE
                  SYNTAX INTEGER {
                                  default (1),
                                  noFacility (2),
                                  noChargingInfo (3),
                                  chargingInfo (4)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The charging Information facility.  A value
                          of default for a circuit means use the PLE
                          default.  The value of default for the
                          default PLE parameters means use noFacility.
                          The value of noFacility means do not include
                          a facility."
                  REFERENCE "See ISO 8208 Section 15.2.2.8"
                  DEFVAL { noFacility }
                  ::= { x25CallParmEntry 17 }

          x25CallParmRpoa OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE(0..108))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The RPOA facility.  The octet string
                          contains n * 4 sequences of the characters
                          0-9 to specify a facility with n entries.
                          The octet string containing the 3 characters
                          DEF for a circuit specifies use of the PLE
                          default (the entry for the PLE default may
                          not contain DEF).  A zero length string
                          indicates no facility requested."
                  REFERENCE "See ISO 8208, section 15.2.2.9"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 18 }

          x25CallParmTrnstDly     OBJECT-TYPE
                  SYNTAX  INTEGER (0..65537)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Transit Delay Selection and Indication
                          value.  A value of 65536 indicates no
                          facility requested.  A value of 65537 for a
                          circuit means use the PLE default (the PLE


                          default parameters entry may not use the
                          value 65537).  The value 65535 may only be
                          used to indicate the value in use by a
                          circuit."
                  REFERENCE "See ISO 8208, Section 15.2.2.13"
                  DEFVAL { 65536 }
                  ::= { x25CallParmEntry 19 }

                  -- The following parameters are for CCITT facilities.

          x25CallParmCallingExt OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE(0..40))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Calling Extension facility.  This
                          contains one of the following:

                          A sequence of hex digits with the value to
                          be put in the facility. These digits will be
                          converted to binary by the agent and put in
                          the facility.  These octets do not include
                          the length octet.

                          A value containing the three character DEF
                          for a circuit means use the PLE default,
                          (the entry for the PLE default parameters
                          may not use the value DEF).

                          A zero length string indicates no facility
                          requested."
                  REFERENCE "See ISO 8208 Section 15.3.2.1"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 20 }

          x25CallParmCalledExt OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE(0..40))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Called Extension facility.  This
                          contains one of the following:

                          A sequence of hex digits with the value to
                          be put in the facility.  These digits will be
                          converted to binary by the agent and put in
                          the facility.  These octets do not include


                          the length octet.

                          A value containing the three character DEF
                          for a circuit means use the PLE default,
                          (the entry for the PLE default parameters
                          may not use the value DEF).

                          A zero length string indicates no facility
                          requested."
                  REFERENCE "See ISO 8208 Section 15.3.2.2"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 21 }

          x25CallParmInMinThuPutCls       OBJECT-TYPE
                  SYNTAX  INTEGER (0..17)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The minimum input throughput Class.  A
                          value of 16 for a circuit means use the PLE
                          default (the PLE parameters entry may not
                          use this value).  A value of 17 indicates no
                          facility requested."
                  REFERENCE "See ISO 8208 Section 15.3.2.3"
                  DEFVAL { 17 }
                  ::= { x25CallParmEntry 22 }

          x25CallParmOutMinThuPutCls OBJECT-TYPE
                  SYNTAX  INTEGER (0..17)
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The minimum output throughput Class.  A
                          value of 16 for a circuit means use the PLE
                          default (the PLE parameters entry may not
                          use this value).  A value of 17 indicates no
                          facility requested."
                  REFERENCE "See ISO 8208 Section 15.3.2.3"
                  DEFVAL { 17 }
                  ::= { x25CallParmEntry 23 }

          x25CallParmEndTrnsDly OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE(0..6))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The End-to-End Transit Delay to negotiate.
                          An octet string of length 2, 4, or 6


                          contains the facility encoded as specified
                          in ISO/IEC 8208 section 15.3.2.4.  An octet
                          string of length 3 containing the three
                          character DEF for a circuit means use the
                          PLE default (the entry for the PLE default
                          can not contain the characters DEF).  A zero
                          length string indicates no facility
                          requested."
                  REFERENCE "See ISO 8208 Section 15.3.2.4"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 24 }

          x25CallParmPriority OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE(0..6))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The priority facility to negotiate.  The
                          octet string encoded as specified in ISO/IEC
                          8208 section 15.3.2.5.  A zero length string
                          indicates no facility requested.  The entry
                          for the PLE default parameters must be zero
                          length."
                  REFERENCE "See ISO 8208 Section 15.3.2.5"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 25 }

          x25CallParmProtection OBJECT-TYPE
                  SYNTAX  DisplayString (SIZE(0..108))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "A string contains the following:
                          A hex string containing the value for the
                          protection facility.  This will be converted
                          from hex to the octets actually in the
                          packet by the agent.  The agent will supply
                          the length field and the length octet is not
                          contained in this string.

                          An string containing the 3 characters DEF
                          for a circuit means use the PLE default (the
                          entry for the PLE default parameters may not
                          use the value DEF).

                          A zero length string mean no facility
                          requested."
                  REFERENCE "See ISO 8208 Section 15.3.2.5"


                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 26 }

          x25CallParmExptData OBJECT-TYPE
                  SYNTAX  INTEGER {
                                  default (1),
                                  noExpeditedData (2),
                                  expeditedData (3)
                          }
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The Expedited Data facility to negotiate.
                          A value of default for a circuit means use
                          the PLE default value.  The entry for the
                          PLE default parameters may not have the
                          value default."
                  REFERENCE "See ISO 8208 Section 15.3.2.7"
                  DEFVAL { noExpeditedData }
                  ::= { x25CallParmEntry 27 }

          x25CallParmUserData     OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE (0..128))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The call user data as placed in the packet.
                          A zero length string indicates no call user
                          data.  If both the circuit call parameters
                          and the PLE default have call user data
                          defined, the data from the circuit call
                          parameters will be used.  If only the PLE
                          has data defined, the PLE entry will be
                          used.  If neither the circuit call
                          parameters or the PLE default entry has a
                          value, no call user data will be sent."
                  REFERENCE "See ISO 8208 Section 12.2.1.1.6, 12.2.1.2"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 28 }

          x25CallParmCallingNetworkFacilities     OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE (0..108))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The calling network facilities.  The
                          facilities are encoded here exactly as
                          encoded in the call packet.  These


                          facilities do not include the marker
                          facility code.

                          A zero length string in the entry for the
                          parameter to use when establishing a circuit
                          means use the PLE default.  A zero length
                          string in the entry for PLE default
                          parameters indicates no default facilities."
                  REFERENCE "See ISO 8206 Section 15.1, category b"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 29 }

          x25CallParmCalledNetworkFacilities      OBJECT-TYPE
                  SYNTAX  OCTET STRING (SIZE (0..108))
                  ACCESS  read-write
                  STATUS  mandatory
                  DESCRIPTION
                          "The called network facilities.  The
                          facilities are encoded here exactly as
                          encoded in the call packet.  These
                          facilities do not include the marker
                          facility code.

                          A zero length string in the entry for the
                          parameter to use when establishing a circuit
                          means use the PLE default.  A zero length
                          string in the entry for PLE default
                          parameters indicates no default facilities."
                  REFERENCE "See ISO 8206 Section 15.1, category c"
                  DEFVAL { ''h }
                  ::= { x25CallParmEntry 30 }

          -- ###########################################################
          --              X.25 Traps
          -- ###########################################################

          x25Restart      TRAP-TYPE
                  ENTERPRISE  x25
                  VARIABLES { x25OperIndex }
                  DESCRIPTION
                          "This trap means the X.25 PLE sent or
                          received a restart packet.  The restart that
                          brings up the link should not send a
                          x25Restart trap so the interface should send
                          a linkUp trap.  Sending this trap means the
                          agent does not send a linkDown and linkUp
                          trap."
                  ::= 1


          x25Reset        TRAP-TYPE
                  ENTERPRISE  x25
                  VARIABLES { x25CircuitIndex,
                          x25CircuitChannel }
                  DESCRIPTION
                          "If the PLE sends or receives a reset, the
                          agent should send an x25Reset trap."
                  ::= 2

          -- ###########################################################
          --              X.25 Protocol Version Identifiers
          -- ###########################################################

          x25ProtocolVersion OBJECT IDENTIFIER
                  ::= { x25 10 }

                  -- X.25 CCITT 1976 version.
          x25protocolCcittV1976 OBJECT IDENTIFIER
                  ::= { x25ProtocolVersion 1 }

                  -- X.25 CCITT 1980 version.
          x25protocolCcittV1980 OBJECT IDENTIFIER
                  ::= { x25ProtocolVersion 2 }

                  -- X.25 CCITT 1984 version.
          x25protocolCcittV1984 OBJECT IDENTIFIER
                  ::= { x25ProtocolVersion 3 }

                  -- X.25 CCITT 1988 version.
          x25protocolCcittV1988 OBJECT IDENTIFIER
                  ::= { x25ProtocolVersion 4 }

                  -- X.25 1987 version of ISO 8208.
          x25protocolIso8208V1987 OBJECT IDENTIFIER
                  ::= { x25ProtocolVersion 5 }

                  -- X.25 1989 version of ISO 8208.
          x25protocolIso8208V1989 OBJECT IDENTIFIER
                  ::= { x25ProtocolVersion 6 }

          -- ###########################################################

END