File: rfc1407.mib

package info (click to toggle)
scotty 2.1.9-1
  • links: PTS
  • area: main
  • in suites: hamm
  • size: 9,984 kB
  • ctags: 4,313
  • sloc: ansic: 35,946; sh: 12,591; tcl: 8,122; yacc: 2,442; makefile: 898; lex: 370
file content (1424 lines) | stat: -rw-r--r-- 54,578 bytes parent folder | download | duplicates (2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
RFC1407-MIB DEFINITIONS ::= BEGIN

               IMPORTS
                       Gauge
                               FROM RFC1155-SMI
                       DisplayString, transmission
                               FROM RFC1213-MIB
                       OBJECT-TYPE
                               FROM RFC-1212;

               -- This MIB module uses the extended OBJECT-TYPE macro
               -- as defined in RFC 1212.

                       ds3  OBJECT IDENTIFIER ::= { transmission 30 }

               -- The DS3/E3 Near End Group

               -- Implementation of this group is mandatory for all
               -- systems that attach to a DS3/E3 Interface.

               -- The DS3/E3 Near End Group consists of four tables:
               --    DS3/E3 Configuration
               --    DS3/E3 Current
               --    DS3/E3 Interval
               --    DS3/E3 Total

               -- the DS3/E3 Configuration

               dsx3ConfigTable OBJECT-TYPE
                   SYNTAX  SEQUENCE OF Dsx3ConfigEntry
                   ACCESS  not-accessible
                   STATUS  mandatory
                   DESCRIPTION
                           "The DS3/E3 Configuration table."
                  ::= { ds3 5 }

              dsx3ConfigEntry OBJECT-TYPE
                  SYNTAX  Dsx3ConfigEntry
                  ACCESS  not-accessible
                  STATUS  mandatory
                  DESCRIPTION
                          "An entry in the DS3/E3 Configuration table."
                 INDEX   { dsx3LineIndex }
                 ::= { dsx3ConfigTable 1 }


             Dsx3ConfigEntry ::=
                 SEQUENCE {
                     dsx3LineIndex
                         INTEGER,
                     dsx3IfIndex
                         INTEGER,
                     dsx3TimeElapsed
                         INTEGER,
                     dsx3ValidIntervals
                         INTEGER,
                     dsx3LineType
                         INTEGER,
                     dsx3LineCoding
                         INTEGER,
                     dsx3SendCode
                         INTEGER,
                     dsx3CircuitIdentifier
                         DisplayString,
                     dsx3LoopbackConfig
                         INTEGER,
                     dsx3LineStatus
                         INTEGER,
                     dsx3TransmitClockSource
                         INTEGER
             }

             dsx3LineIndex OBJECT-TYPE
                 SYNTAX  INTEGER (1..65535)
                 ACCESS  read-only
                 STATUS  mandatory
                 DESCRIPTION
                         "This object is the identifier of a DS3/E3
                         Interface on a managed device.  If there is an
                         ifEntry that is directly associated with this
                         and only this DS3/E3 interface, it should have
                         the same value as ifIndex.  Otherwise, number
                         the dsx3LineIndices with an unique identifier
                         following the rules of choosing a number that
                         is greater than ifNumber and numbering the
                         inside interfaces (e.g., equipment side) with
                         even numbers and outside interfaces (e.g,
                         network side) with odd numbers."
                ::= { dsx3ConfigEntry 1 }

            dsx3IfIndex OBJECT-TYPE
                SYNTAX  INTEGER (1..65535)
                ACCESS  read-only
                STATUS  mandatory


                DESCRIPTION
                        "This value for this object is equal to the
                        value of ifIndex from the Interfaces table of
                        MIB II (RFC 1213)."
               ::= { dsx3ConfigEntry 2 }

           dsx3TimeElapsed OBJECT-TYPE
               SYNTAX  INTEGER (0..899)
               ACCESS  read-only
               STATUS  mandatory
               DESCRIPTION
                       "The number of seconds that have elapsed since
                       the beginning of the near end current error-
                       measurement period."
              ::= { dsx3ConfigEntry 3 }

          dsx3ValidIntervals OBJECT-TYPE
              SYNTAX  INTEGER (0..96)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of previous near end intervals for
                      which valid data was collected.  The value will be
                      96 unless the interface was brought online within
                      the last 24 hours, in which case the value will be
                      the number of complete 15 minute near end
                      intervals since the interface has been online."
              ::= { dsx3ConfigEntry 4 }

          dsx3LineType OBJECT-TYPE
              SYNTAX  INTEGER {
                          dsx3other(1),
                          dsx3M23(2),
                          dsx3SYNTRAN(3),
                          dsx3CbitParity(4),
                          dsx3ClearChannel(5),
                          e3other(6),
                          e3Framed(7),
                          e3Plcp(8)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "This variable indicates the variety of DS3 C-bit
                      or E3 application
                      implementing this interface.  The type of
                      interface affects the interpretation of the
                      usage and error statistics.


                      The rate of DS3 is 44.736 Mbps and E3 is
                      34.368 Mbps.
                      The dsx3ClearChannel value means that the C-bits
                      are not used except for sending/receiving
                      AIS.

                      The values, in sequence, describe:

                      TITLE:            SPECIFICATION:
                      dsx3M23            ANSI T1.107-1988
                      dsx3SYNTRAN        ANSI T1.107-1988
                      dsx3CbitParity     ANSI T1.107a-1989
                      dsx3ClearChannel   ANSI T1.102-1987
                      e3Framed           CCITT G.751
                      e3Plcp             ETSI T/NA(91)18."
              ::= { dsx3ConfigEntry 5 }

          dsx3LineCoding OBJECT-TYPE
              SYNTAX  INTEGER {
                          dsx3Other(1),
                          dsx3B3ZS(2),
                          e3HDB3(3)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "This variable describes the variety of Zero Code
                      Suppression used on this interface, which in turn
                      affects a number of its characteristics.

                      dsx3B3ZS and e3HDB3 refer to the use of specified
                      patterns of normal bits and bipolar violations
                      which are used to replace sequences of zero bits
                      of a specified length."
              ::= { dsx3ConfigEntry 6 }

          dsx3SendCode OBJECT-TYPE
                 SYNTAX  INTEGER {
                         dsx3SendNoCode(1),
                         dsx3SendLineCode(2),
                         dsx3SendPayloadCode(3),
                         dsx3SendResetCode(4),
                         dsx3SendDS1LoopCode(5),
                         dsx3SendTestPattern(6)
                         }
                 ACCESS  read-write
                 STATUS  mandatory
                 DESCRIPTION


                      "This variable indicates what type of code is
                      being sent across the DS3/E3 interface by the
                      device.  (These are optional for E3 interfaces.)
                      The values mean:

                         dsx3SendNoCode
                             sending looped or normal data

                         dsx3SendLineCode
                             sending a request for a line loopback

                         dsx3SendPayloadCode
                             sending a request for a payload loopback
                             (i.e., all DS1/E1s in a DS3/E3 frame)

                         dsx3SendResetCode
                             sending a loopback deactivation request

                         dsx3SendDS1LoopCode
                             requesting to loopback a particular DS1/E1
                             within a DS3/E3 frame

                         dsx3SendTestPattern
                             sending a test pattern."
                 ::= { dsx3ConfigEntry 7 }

          dsx3CircuitIdentifier OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..255))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                      "This variable contains the transmission vendor's
                      circuit identifier, for the purpose of
                      facilitating troubleshooting."
              ::= { dsx3ConfigEntry 8 }

          dsx3LoopbackConfig OBJECT-TYPE
                 SYNTAX  INTEGER {
                           dsx3NoLoop(1),
                           dsx3PayloadLoop(2),
                           dsx3LineLoop(3),
                           dsx3OtherLoop(4)
                         }
                 ACCESS  read-write
                 STATUS  mandatory
                 DESCRIPTION
                    "This variable represents the loopback configuration
                    of the DS3/E3 interface.


                    The values mean:

                    dsx3NoLoop
                      Not in the loopback state.  A device that is
                      not capable of performing a loopback on
                      the interface shall always return this as
                      it's value.

                    dsx3PayloadLoop
                      The received signal at this interface is looped
                      through the device.
                      Typically the received signal
                      is looped back for retransmission after it has
                      passed through the device's framing function.

                    dsx3LineLoop
                      The received signal at this interface does not
                      go through the device (minimum penetration) but
                      is looped back out.

                    dsx3OtherLoop
                      Loopbacks that are not defined here."
                 ::= { dsx3ConfigEntry 9 }

          dsx3LineStatus OBJECT-TYPE
              SYNTAX  INTEGER (1..1023)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "This variable indicates the
                 Line Status of the interface.
                 It contains loopback state information
                 and failure state information.
                 The dsx3LineStatus is a bit map represented
                 as a sum, therefore,
                 it can represent multiple failures
                 and a loopback (see dsx3LoopbackConfig object
                 for the type of loopback)
                 simultaneously.
                 The dsx3NoAlarm should be set if and only if
                 no other flag is set.

                 The various bit positions are:
                    1     dsx3NoAlarm       No alarm present
                    2     dsx3RcvRAIFailure Receiving Yellow/Remote
                          Alarm Indication
                    4     dsx3XmitRAIAlarm Transmitting Yellow/Remote
                          Alarm Indication


                    8     dsx3RcvAIS        Receiving AIS failure state
                   16     dsx3XmitAIS       Transmitting AIS
                   32     dsx3LOF           Receiving LOF failure state
                   64     dsx3LOS           Receiving LOS failure state
                  128     dsx3LoopbackState Looping the received signal
                  256     dsx3RcvTestCode   Receiving a Test Pattern
                  512     dsx3OtherFailure any line status not defined
                          here"
              ::= { dsx3ConfigEntry 10 }

          dsx3TransmitClockSource OBJECT-TYPE
              SYNTAX  INTEGER {
                          loopTiming(1),
                          localTiming(2),
                          throughTiming(3)
                      }
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                 "The source of Transmit Clock.
                 is derived from the recovered receive clock of
                 another DS3 interface."
              ::= { dsx3ConfigEntry 11 }

          -- the DS3/E3 Current

          -- The DS3/E3 current table contains various statistics being
          -- collected for the current 15 minute interval.

          dsx3CurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3CurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3/E3 Current table."
              ::= { ds3 6 }

          dsx3CurrentEntry OBJECT-TYPE
              SYNTAX  Dsx3CurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3/E3 Current table."
              INDEX   { dsx3CurrentIndex }
              ::= { dsx3CurrentTable 1 }


          Dsx3CurrentEntry ::=
              SEQUENCE {
                  dsx3CurrentIndex
                      INTEGER,
                  dsx3CurrentPESs
                      Gauge,
                  dsx3CurrentPSESs
                      Gauge,
                  dsx3CurrentSEFSs
                      Gauge,
                  dsx3CurrentUASs
                      Gauge,
                  dsx3CurrentLCVs
                      Gauge,
                  dsx3CurrentPCVs
                      Gauge,
                  dsx3CurrentLESs
                      Gauge,
                  dsx3CurrentCCVs
                      Gauge,
                  dsx3CurrentCESs
                      Gauge,
                  dsx3CurrentCSESs
                      Gauge
              }

          dsx3CurrentIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3/E3 interface to which this entry is
                      applicable.  The interface identified by a
                      particular value of this index is the same
                      interface as identified by the same value an
                      dsx3LineIndex object instance."
              ::= { dsx3CurrentEntry 1 }

          dsx3CurrentPESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Errored Seconds, encountered by a DS3 interface in
                      the current 15 minute interval."
              ::= { dsx3CurrentEntry 2 }


          dsx3CurrentPSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Severely Errored Seconds, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { dsx3CurrentEntry 3 }

          dsx3CurrentSEFSs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Severely Errored Framing Seconds, encountered by a
                      DS3/E3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 4 }

          dsx3CurrentUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { dsx3CurrentEntry 5 }

          dsx3CurrentLCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of Line
                      Coding Violations encountered by a DS3/E3
                      interface in the current 15 minute interval."
              ::= { dsx3CurrentEntry 6 }

          dsx3CurrentPCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Coding Violations, encountered by a DS3 interface


                      in the current 15 minute interval."
              ::= { dsx3CurrentEntry 7 }

          dsx3CurrentLESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of Line Errored Seconds encountered by
                      a DS3/E3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 8 }

          dsx3CurrentCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Coding Violations encountered
                      by a DS3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 9 }

          dsx3CurrentCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Errored Seconds encountered
                      by a DS3 interface in the current 15 minute
                      interval."
              ::= { dsx3CurrentEntry 10 }

          dsx3CurrentCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Severely Errored Seconds
                      encountered by a DS3 interface in the current 15
                      minute interval."
              ::= { dsx3CurrentEntry 11 }

          -- the DS3/E3 Interval

          -- The DS3/E3 Interval Table contains various statistics
          -- collected by each DS3/E3 Interface over the previous 24


          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          dsx3IntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3IntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3/E3 Interval table."
              ::= { ds3 7 }

          dsx3IntervalEntry OBJECT-TYPE
              SYNTAX  Dsx3IntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3/E3 Interval table."
              INDEX   { dsx3IntervalIndex, dsx3IntervalNumber }
              ::= { dsx3IntervalTable 1 }

          Dsx3IntervalEntry ::=
              SEQUENCE {
                  dsx3IntervalIndex
                      INTEGER,
                  dsx3IntervalNumber
                      INTEGER,
                  dsx3IntervalPESs
                      Gauge,
                  dsx3IntervalPSESs
                      Gauge,
                  dsx3IntervalSEFSs
                      Gauge,
                  dsx3IntervalUASs
                      Gauge,
                  dsx3IntervalLCVs
                      Gauge,
                  dsx3IntervalPCVs
                      Gauge,
                  dsx3IntervalLESs
                      Gauge,
                  dsx3IntervalCCVs
                      Gauge,
                  dsx3IntervalCESs
                      Gauge,
                  dsx3IntervalCSESs
                      Gauge
              }


          dsx3IntervalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3/E3 interface to which this entry is
                      applicable.  The interface identified by a
                      particular value of this index is the same
                      interface as identified by the same value an
                      dsx3LineIndex object instance."
              ::= { dsx3IntervalEntry 1 }

          dsx3IntervalNumber OBJECT-TYPE
              SYNTAX  INTEGER (1..96)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "A number between 1 and 96, where 1 is the most
                      recently completed 15 minute interval and 96 is
                      the least recently completed 15 minutes interval
                      (assuming that all 96 intervals are valid)."
              ::= { dsx3IntervalEntry 2 }

          dsx3IntervalPESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Errored Seconds, encountered by a DS3 interface in
                      one of the previous 96, individual 15 minute,
                      intervals."
              ::= { dsx3IntervalEntry 3 }

          dsx3IntervalPSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Severely Errored Seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { dsx3IntervalEntry 4 }

          dsx3IntervalSEFSs OBJECT-TYPE
              SYNTAX  Gauge


              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Severely Errored Framing Seconds, encountered by a
                      DS3/E3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 5 }

          dsx3IntervalUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, encountered by a DS3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { dsx3IntervalEntry 6 }

          dsx3IntervalLCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of Line
                      Coding Violations encountered by a DS3/E3
                      interface in one of the previous 96, individual 15
                      minute, intervals."
              ::= { dsx3IntervalEntry 7 }

          dsx3IntervalPCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Coding Violations, encountered by a DS3 interface
                      in one of the previous 96, individual 15 minute,
                      intervals."
              ::= { dsx3IntervalEntry 8 }

          dsx3IntervalLESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of Line Errored  Seconds  (BPVs  or


                   illegal  zero  sequences) encountered by a DS3/E3
                   interface in one of the previous 96, individual
                   15 minute, intervals."
              ::= { dsx3IntervalEntry 9 }

          dsx3IntervalCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Coding Violations encountered
                      by a DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 10 }

          dsx3IntervalCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Errored Seconds encountered
                      by a DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 11 }

          dsx3IntervalCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Severely Errored Seconds
                      encountered by a DS3 interface in one of the
                      previous 96, individual 15 minute, intervals."
              ::= { dsx3IntervalEntry 12 }

          -- the DS3/E3 Total

          -- The DS3/E3 Total Table contains the cumulative sum of the
          -- various statistics for the 24 hour period preceding the
          -- current interval.

          dsx3TotalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3TotalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3/E3 Total table.  24 hour interval."


              ::= { ds3 8 }

          dsx3TotalEntry OBJECT-TYPE
              SYNTAX  Dsx3TotalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3/E3 Total table."
              INDEX   { dsx3TotalIndex }
              ::= { dsx3TotalTable 1 }

          Dsx3TotalEntry ::=
              SEQUENCE {
                  dsx3TotalIndex
                      INTEGER,
                  dsx3TotalPESs
                      Gauge,
                  dsx3TotalPSESs
                      Gauge,
                  dsx3TotalSEFSs
                      Gauge,
                  dsx3TotalUASs
                      Gauge,
                  dsx3TotalLCVs
                      Gauge,
                  dsx3TotalPCVs
                      Gauge,
                  dsx3TotalLESs
                      Gauge,
                  dsx3TotalCCVs
                      Gauge,
                  dsx3TotalCESs
                      Gauge,
                  dsx3TotalCSESs
                      Gauge
              }

          dsx3TotalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3/E3 interface to which this entry is
                      applicable.  The interface identified by a
                      particular value of this index is the same
                      interface as identified by the same value an
                      dsx3LineIndex object instance."


              ::= { dsx3TotalEntry 1 }

          dsx3TotalPESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Errored Seconds, encountered by a DS3 interface in
                      the previous 24 hour interval"
              ::= { dsx3TotalEntry 2 }

          dsx3TotalPSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Severely Errored Seconds, encountered by a DS3
                      interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 3 }

          dsx3TotalSEFSs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Severely Errored Framing Seconds, encountered by a
                      DS3/E3 interface in the previous 24 hour
                      interval."
              ::= { dsx3TotalEntry 4 }

          dsx3TotalUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Unavailable Seconds, encountered by a DS3
                      interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 5 }

          dsx3TotalLCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION


                      "The counter associated with the number of Line
                      Coding Violations encountered by a DS3/E3
                      interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 6 }

          dsx3TotalPCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of P-bit
                      Coding Violations, encountered by a DS3 interface
                      in the previous 24 hour interval."
              ::= { dsx3TotalEntry 7 }

          dsx3TotalLESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The number of Line Errored  Seconds  (BPVs  or
                   illegal  zero  sequences) encountered by a DS3/E3
                   interface in the previous 24 hour interval."
              ::= { dsx3TotalEntry 8 }

          dsx3TotalCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Coding Violations encountered
                      by a DS3 interface in the previous 24 hour
                      interval."
              ::= { dsx3TotalEntry 9 }

          dsx3TotalCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Errored Seconds encountered
                      by a DS3 interface in the previous 24 hour
                      interval."
              ::= { dsx3TotalEntry 10 }

          dsx3TotalCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only


              STATUS  mandatory
              DESCRIPTION
                      "The number of C-bit Severely Errored Seconds
                      encountered by a DS3 interface in the previous 24
                      hour interval."
              ::= { dsx3TotalEntry 11 }

          -- The DS3 Far End Group

          -- Implementation of this group is optional for all systems
          -- that attach to a DS3 Interface.
          -- However, only C-bit Parity and SYNTRAN DS3 applications
          -- have the capability (option) of providing this information.

          -- The DS3 Far End Group consists of four tables:
          --   DS3 Far End Configuration
          --   DS3 Far End Current
          --   DS3 Far End Interval
          --   DS3 Far End Total

          -- The DS3 Far End Configuration Table contains
          -- configuration information
          -- reported in the C-bits from the remote end.

          dsx3FarEndConfigTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndConfigEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                 "The DS3 Far End Configuration table."
              ::= { ds3 9 }

          dsx3FarEndConfigEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndConfigEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                   "An entry in the DS3 Far End Configuration table."
              INDEX   { dsx3FarEndLineIndex }
              ::= { dsx3FarEndConfigTable 1 }

          Dsx3FarEndConfigEntry ::=
              SEQUENCE {
                  dsx3FarEndLineIndex
                      INTEGER,
                  dsx3FarEndEquipCode


                      DisplayString,
                  dsx3FarEndLocationIDCode
                      DisplayString,
                  dsx3FarEndFrameIDCode
                      DisplayString,
                  dsx3FarEndUnitCode
                      DisplayString,
                  dsx3FarEndFacilityIDCode
                      DisplayString
               }

          dsx3FarEndLineIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                   "The index value which uniquely identifies the
                   DS3 interface
                   to which this entry is applicable.  The
                   interface identified by a particular value of
                   this index is the same interface as identified
                   by the same value an dsx3LineIndex object
                   instance."
             ::= { dsx3FarEndConfigEntry 1 }

          dsx3FarEndEquipCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..10))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End Equipment Identification code
                    that describes the specific piece of equipment.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 2 }

          dsx3FarEndLocationIDCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..11))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End Location Identification code
                    that describes the specific location of the
                    equipment.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 3 }


          dsx3FarEndFrameIDCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..10))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End Frame Identification code
                    that identifies where the equipment is located
                    within a building at a given location.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 4 }

          dsx3FarEndUnitCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..6))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This is the Far End code
                    that identifies the equipment location within a bay.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 5 }

          dsx3FarEndFacilityIDCode OBJECT-TYPE
              SYNTAX  DisplayString (SIZE (0..38))
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                    "This code identifies a specific Far End DS3 path.
                    It is sent within the Path
                    Identification Message."
              ::= { dsx3FarEndConfigEntry 6 }

          -- The DS3 Far End Current

          -- The DS3 Far End Current table contains various statistics
          -- being collected for the current 15 minute interval.
          -- The statistics are collected from the far end block error
          -- code within the C-bits.

          dsx3FarEndCurrentTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndCurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3 Far End Current table."
              ::= { ds3 10 }


          dsx3FarEndCurrentEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndCurrentEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3 Far End Current table."
              INDEX   { dsx3FarEndCurrentIndex }
              ::= { dsx3FarEndCurrentTable 1 }

          Dsx3FarEndCurrentEntry ::=
              SEQUENCE {
                  dsx3FarEndCurrentIndex
                      INTEGER,
                  dsx3FarEndTimeElapsed
                      INTEGER,
                  dsx3FarEndValidIntervals
                      INTEGER,
                  dsx3FarEndCurrentCESs
                      Gauge,
                  dsx3FarEndCurrentCSESs
                      Gauge,
                  dsx3FarEndCurrentCCVs
                      Gauge,
                  dsx3FarEndCurrentUASs
                      Gauge
              }

           dsx3FarEndCurrentIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3 interface
                      to which this entry is applicable.  The interface
                      identified by a particular value of this index is
                      the same interface as identified by the same value
                      an dsx3LineIndex object instance."
              ::= { dsx3FarEndCurrentEntry 1 }

          dsx3FarEndTimeElapsed OBJECT-TYPE
              SYNTAX  INTEGER (0..899)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of seconds that have elapsed since the
                      beginning of the far end current error-measurement
                      period."


              ::= { dsx3FarEndCurrentEntry 2 }

          dsx3FarEndValidIntervals OBJECT-TYPE
              SYNTAX  INTEGER (0..96)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The number of previous far end intervals for
                      which valid data was collected.  The value will be
                      96 unless the interface was brought online within
                      the last 24 hours, in which case the value will be
                      the number of complete 15 minute far end intervals
                      since the interface has been online."
              ::= { dsx3FarEndCurrentEntry 3 }

          dsx3FarEndCurrentCESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of Far
                      Far End C-bit Errored Seconds encountered by a DS3
                      interface in the current 15 minute interval."
              ::= { dsx3FarEndCurrentEntry 4 }

          dsx3FarEndCurrentCSESs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End C-bit Severely Errored Seconds
                      encountered by a DS3 interface in the current 15
                      minute interval."
              ::= { dsx3FarEndCurrentEntry 5 }

          dsx3FarEndCurrentCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End C-bit Coding Violations reported via
                      the far end block error count
                      encountered by a
                      DS3 interface in the current 15 minute interval."
              ::= { dsx3FarEndCurrentEntry 6 }


          dsx3FarEndCurrentUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End unavailable seconds
                      encountered by a
                      DS3 interface in the current 15 minute interval."
              ::= { dsx3FarEndCurrentEntry 7 }

          -- The DS3 Far End Interval

          -- The DS3 Far End Interval Table contains various statistics
          -- collected by each DS3 interface over the previous 24
          -- hours of operation.  The past 24 hours are broken into 96
          -- completed 15 minute intervals.

          dsx3FarEndIntervalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndIntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                     "The DS3 Far End Interval table."
              ::= { ds3 11 }

          dsx3FarEndIntervalEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndIntervalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                    "An entry in the DS3 Far
                    End Interval table."
              INDEX   { dsx3FarEndIntervalIndex,
                        dsx3FarEndIntervalNumber }
              ::= { dsx3FarEndIntervalTable 1 }

          Dsx3FarEndIntervalEntry ::=
              SEQUENCE {
                   dsx3FarEndIntervalIndex
                        INTEGER,
                   dsx3FarEndIntervalNumber
                        INTEGER,
                   dsx3FarEndIntervalCESs
                        Gauge,
                   dsx3FarEndIntervalCSESs
                        Gauge,


                   dsx3FarEndIntervalCCVs
                        Gauge,
                   dsx3FarEndIntervalUASs
                        Gauge
              }

          dsx3FarEndIntervalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3 interface
                      to which this entry is applicable.  The
                      interface identified by a particular value of
                      this index is the same interface as identified
                      by the same value an dsx3LineIndex object
                      instance."
              ::= { dsx3FarEndIntervalEntry 1 }

          dsx3FarEndIntervalNumber OBJECT-TYPE
             SYNTAX  INTEGER (1..96)
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                    "A number between 1 and 96, where 1 is the most
                    recently completed 15 minute interval and 96 is
                    the least recently completed 15 minutes
                    interval (assuming that all 96 intervals are
                    valid)."
             ::= { dsx3FarEndIntervalEntry 2 }

          dsx3FarEndIntervalCESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of
                      Far End C-bit Errored Seconds encountered
                      by a DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
            ::= { dsx3FarEndIntervalEntry 3 }

          dsx3FarEndIntervalCSESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION


                     "The counter associated with the number of
                     Far End C-bit Severely Errored Seconds
                     encountered by a DS3 interface in one of the
                     previous 96, individual 15 minute, intervals."
            ::= { dsx3FarEndIntervalEntry 4 }

          dsx3FarEndIntervalCCVs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End C-bit Coding Violations reported via
                      the far end block error count
                      encountered by a
                      DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3FarEndIntervalEntry 5 }

          dsx3FarEndIntervalUASs OBJECT-TYPE
              SYNTAX  Gauge
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The counter associated with the number of
                      Far End unavailable seconds
                      encountered by a
                      DS3 interface in one of the previous 96,
                      individual 15 minute, intervals."
              ::= { dsx3FarEndIntervalEntry 6 }

          -- The DS3 Far End Total

          -- The DS3 Far End Total Table contains the cumulative sum
          -- of the various statistics for the 24 hour period preceding
          -- the current interval.

          dsx3FarEndTotalTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FarEndTotalEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "The DS3 Far End Total table.  24 hour interval."
              ::= { ds3 12 }

          dsx3FarEndTotalEntry OBJECT-TYPE
              SYNTAX  Dsx3FarEndTotalEntry


              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                      "An entry in the DS3 Far End Total table."
              INDEX   { dsx3FarEndTotalIndex }
              ::= { dsx3FarEndTotalTable 1 }

          Dsx3FarEndTotalEntry ::=
              SEQUENCE {
                  dsx3FarEndTotalIndex
                      INTEGER,
                  dsx3FarEndTotalCESs
                      Gauge,
                  dsx3FarEndTotalCSESs
                      Gauge,
                  dsx3FarEndTotalCCVs
                      Gauge,
                  dsx3FarEndTotalUASs
                      Gauge
              }

          dsx3FarEndTotalIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..65535)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                      "The index value which uniquely identifies the
                      DS3 interface
                      to which this entry is applicable.  The interface
                      identified by a particular value of this index is
                      the same interface as identified by the same value
                      an dsx3LineIndex object instance."
              ::= { dsx3FarEndTotalEntry 1 }

          dsx3FarEndTotalCESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of Far
                     End C-bit Errored Seconds encountered by a DS3
                     interface in the previous 24 hour interval."
             ::= { dsx3FarEndTotalEntry 2 }

          dsx3FarEndTotalCSESs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory


             DESCRIPTION
                     "The counter associated with the number of
                     Far End C-bit Severely Errored Seconds
                     encountered by a DS3 interface in the previous 24
                     hour interval."
             ::= { dsx3FarEndTotalEntry 3 }

          dsx3FarEndTotalCCVs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of
                     Far End C-bit Coding Violations reported via the
                     far end block error count
                     encountered by a
                     DS3 interface in the previous 24 hour interval."
             ::= { dsx3FarEndTotalEntry 4 }

          dsx3FarEndTotalUASs OBJECT-TYPE
             SYNTAX  Gauge
             ACCESS  read-only
             STATUS  mandatory
             DESCRIPTION
                     "The counter associated with the number of
                     Far End unavailable seconds
                     encountered by a
                     DS3 interface in the previous 24 hour interval."
             ::= { dsx3FarEndTotalEntry 5 }

          -- the DS3/E3 Fractional Group

          -- Implementation of this group is optional.  It is designed
          -- for those systems dividing a DS3/E3 into channels
          -- containing different data streams that are of local
          -- interest.

          -- The DS3/E3 fractional table identifies which DS3/E3
          -- channels associated with a CSU are being used to
          -- support a logical interface, i.e., an entry in the
          -- interfaces table from the Internet-standard MIB.

          -- For example, consider a DS3 device with 4 high speed links
          -- carrying router traffic, a feed for voice, a feed for
          -- video, and a synchronous channel for a non-routed
          -- protocol.
          -- We might describe the allocation of channels, in the


          -- dsx3FracTable, as follows:

          -- dsx3FracIfIndex.2. 1 = 3    dsx3FracIfIndex.2.15 = 4
          -- dsx3FracIfIndex.2. 2 = 3    dsx3FracIfIndex.2.16 = 6
          -- dsx3FracIfIndex.2. 3 = 3    dsx3FracIfIndex.2.17 = 6
          -- dsx3FracIfIndex.2. 4 = 3    dsx3FracIfIndex.2.18 = 6
          -- dsx3FracIfIndex.2. 5 = 3    dsx3FracIfIndex.2.19 = 6
          -- dsx3FracIfIndex.2. 6 = 3    dsx3FracIfIndex.2.20 = 6
          -- dsx3FracIfIndex.2. 7 = 4    dsx3FracIfIndex.2.21 = 6
          -- dsx3FracIfIndex.2. 8 = 4    dsx3FracIfIndex.2.22 = 6
          -- dsx3FracIfIndex.2. 9 = 4    dsx3FracIfIndex.2.23 = 6
          -- dsx3FracIfIndex.2.10 = 4    dsx3FracIfIndex.2.24 = 6
          -- dsx3FracIfIndex.2.11 = 4    dsx3FracIfIndex.2.25 = 6
          -- dsx3FracIfIndex.2.12 = 5    dsx3FracIfIndex.2.26 = 6
          -- dsx3FracIfIndex.2.13 = 5    dsx3FracIfIndex.2.27 = 6
          -- dsx3FracIfIndex.2.14 = 5    dsx3FracIfIndex.2.28 = 6

          -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and
          -- dsx3ClearChannel there are 28 legal channels, numbered 1
          -- through 28.

          -- For e3Framed there are 16 legal channels,
          -- numbered 1 through 16.  The channels (1..16) correspond
          -- directly to the equivalently numbered time-slots.

          dsx3FracTable OBJECT-TYPE
              SYNTAX  SEQUENCE OF Dsx3FracEntry
              ACCESS  not-accessible
              STATUS  mandatory
              DESCRIPTION
                 "The DS3 Fractional table."
              ::= { ds3 13 }

          dsx3FracEntry OBJECT-TYPE
               SYNTAX  Dsx3FracEntry
               ACCESS  not-accessible
               STATUS  mandatory
               DESCRIPTION
                  "An entry in the DS3 Fractional table."
              INDEX   { dsx3FracIndex, dsx3FracNumber }
              ::= { dsx3FracTable 1 }

          Dsx3FracEntry ::=
              SEQUENCE {
                  dsx3FracIndex
                      INTEGER,
                  dsx3FracNumber
                      INTEGER,


                  dsx3FracIfIndex
                      INTEGER
              }

          dsx3FracIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..'7fffffff'h)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "The index value which uniquely identifies  the
                 DS3  interface  to which this entry is applicable
                 The interface identified by a  particular
                 value  of  this  index is the same interface as
                 identified by the same value  an  dsx3LineIndex
                 object instance."
             ::= { dsx3FracEntry 1 }

          dsx3FracNumber OBJECT-TYPE
              SYNTAX  INTEGER (1..31)
              ACCESS  read-only
              STATUS  mandatory
              DESCRIPTION
                 "The channel number for this entry."
             ::= { dsx3FracEntry 2 }

          dsx3FracIfIndex OBJECT-TYPE
              SYNTAX  INTEGER (1..'7fffffff'h)
              ACCESS  read-write
              STATUS  mandatory
              DESCRIPTION
                 "An index value that uniquely identifies an
                 interface.  The interface identified by a particular
                 value of this index is the same  interface
                 as  identified by the same value an ifIndex
                 object instance. If no interface is currently using
                 a channel, the value should be zero.  If a
                 single interface occupies more  than  one  time
                 slot,  that ifIndex value will be found in multiple
                 time slots."
             ::= { dsx3FracEntry 3 }