File: rfc1559.mib

package info (click to toggle)
scotty 2.1.9-1
  • links: PTS
  • area: main
  • in suites: hamm
  • size: 9,984 kB
  • ctags: 4,313
  • sloc: ansic: 35,946; sh: 12,591; tcl: 8,122; yacc: 2,442; makefile: 898; lex: 370
file content (3131 lines) | stat: -rw-r--r-- 102,860 bytes parent folder | download | duplicates (4)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
DECNET-PHIV-MIB DEFINITIONS ::= BEGIN

        IMPORTS
           Gauge
              FROM RFC1155-SMI
            OBJECT-TYPE
               FROM RFC-1212
            mib-2, DisplayString
              FROM RFC1213-MIB;

   -- DECNet Phase-IV MIB

        phiv      OBJECT IDENTIFIER ::= { mib-2 18 }

   -- textual conventions

   PhivAddr ::= OCTET STRING (SIZE (2))
   -- This data type is intended as a short word representation of
   -- standard DECnet Phase IV addresses. DECnet addresses are
   -- hierarchically structured numbers assigned to a particular
   -- DECnet node. The address is structured so that the area
   -- number is contained in the most significant 6 bits of the
   -- first octet.  The next 2 bits of the first octet contain
   -- the first two bits of the host address.  The remainder of
   -- the host address is contained in the second octet.

   PhivCounter ::= INTEGER
   -- This data type has been created for DECnet counters.  These
   -- counters latch at their maximum specified value until either
   -- the system is restarted, or they are reset to zero by the user


   -- or management software.

   InterfaceIndex ::= INTEGER
   --  The range of ifIndex, i.e., (1..2147483647)

   -- groups in the decnetiv mib

         phivSystem             OBJECT IDENTIFIER ::= { phiv 1 }
         phivManagement         OBJECT IDENTIFIER ::= { phiv 2 }
         session                OBJECT IDENTIFIER ::= { phiv 3 }
         end                    OBJECT IDENTIFIER ::= { phiv 4 }
         routing                OBJECT IDENTIFIER ::= { phiv 5 }
         circuit                OBJECT IDENTIFIER ::= { phiv 6 }
         ddcmp                  OBJECT IDENTIFIER ::= { phiv 7 }
         control                OBJECT IDENTIFIER ::= { phiv 8 }
         ethernet               OBJECT IDENTIFIER ::= { phiv 9 }
         counters               OBJECT IDENTIFIER ::= { phiv 10 }
         adjacency              OBJECT IDENTIFIER ::= { phiv 11 }
         line                   OBJECT IDENTIFIER ::= { phiv 12 }
         nonBroadcastLine       OBJECT IDENTIFIER ::= { phiv 14 }
         area                   OBJECT IDENTIFIER ::= { phiv 15 }

   -- System Group

   -- The implementation of the System Group is mandatory for
   -- all systems.

   phivSystemState OBJECT-TYPE
        SYNTAX INTEGER {
            on (1),
            off (2),
            shut (3),
            restricted (4)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This represents the operational state of the executor
            node.
            The possible states are:
            ON          Allows logical links.
            OFF         Allows no new links, terminates existing
                        links, and stops routing traffic through.
            SHUT        Allows no new logical links, does not
                        destroy existing logical links, and goes
                        to the OFF state when all logical links are
                        gone.


            RESTRICTED  Allows no new incoming logical links from
                        other nodes.

            NOTE: These values are incremented by one compared to
            the standard DECnet values in order to maintain
            compliance with RFC 1155)."
        ::= { phivSystem 1 }

   phivExecIdent OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..32))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This is a text string that describes the executor node
            (for example, 'Research Lab').  The string is up to 32
            characters of any type."
        ::= { phivSystem 2 }

   -- Network Management Group

   -- The implementation of the Network Management Group is
   -- mandatory for all systems which contain a DECnet-style
   -- management version.

   phivMgmtMgmtVers OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..255))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This is the read-only Network Management Version,
            consisting of the version number, the Engineering
            Change Order (ECO) number, and the user ECO number
            (for example, 3.0.0). This parameter applies to the
            executor node only."
        ::= { phivManagement 1 }

   -- Session Layer Group

   -- The implementation of the Session Layer Group is optional.
   -- A system can be said to implement this group if and only if
   -- all objects in this group are implemented.

   phivSessionSystemName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..6))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION


            "Name to be associated with the node identification.
            Only one name can be assigned to a node address or a
            circuit identification. No name should be used more than
            once in a DECnet network. Node-name is one to six upper
            case alphanumeric characters with at least one alpha
            character. A length of 0 indicates no name."
        ::= { session 1 }

   phivSessionInTimer OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum duration between the
            time a connect is received for a process at the
            executor node and the time that process accepts or
            rejects it. If the connect is not accepted or rejected
            by the user within the number of seconds specified,
            Session Control rejects it for the user.  A value of 0
            indicates no timer is running."
        ::= { session 2 }

   phivSessionOutTimer OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the duration between the time the
            executor requests a connect and the time that connect is
            acknowledged by the destination node. If the connect is
            not acknowledged within the number of seconds
            specified, Session Control returns an error.  A value of 0
            indicates no timer is running."
        ::= { session 3 }

   -- End Communication Layer Group

   -- The implementation of the End Communication Layer Group is optional.
   -- A system can be said to implement this group if and only if
   -- all objects in this group are implemented.

   -- Remote State Table

   phivEndRemoteTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivEndRemoteEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION


            "Information about the state of sessions between the
            node under study and the nodes found in the table."
        ::= { end 1 }

   phivEndRemoteEntry OBJECT-TYPE
        SYNTAX PhivEndRemoteEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about a particular remote node as seen
            from the end communication layer."
        INDEX  { phivEndRemoteHostNodeID }
        ::= { phivEndRemoteTable 1 }

   PhivEndRemoteEntry ::=
        SEQUENCE {
            phivEndRemoteHostNodeID
                PhivAddr,
            phivEndRemoteState
                INTEGER,
            phivEndCircuitIndex
                INTEGER,
            phivEndActiveLinks
                INTEGER,
            phivEndDelay
                INTEGER
        }

   phivEndRemoteHostNodeID OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value is the address of the remote node to be
            evaluated."
        ::= { phivEndRemoteEntry 1 }

   phivEndRemoteState OBJECT-TYPE
        SYNTAX INTEGER {
            on (1),
            off (2),
            shut (3),
            restricted (4)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This represents the operational state of the remote node


            being evaluated.
            The possible states are:

            ON          Allows logical links.
            OFF         Allows no new links, terminates existing
                        links, and stops routing traffic through.
            SHUT        Allows no new logical links, does not
                        destroy existing logical links, and goes
                        to the OFF state when all logical links are
                        gone.
            RESTRICTED  Allows no new incoming logical links from
                        other nodes.

            NOTE: These values are incremented by one compared to
            the standard DECnet values in order to maintain
            compliance with RFC 1155."
        ::= { phivEndRemoteEntry 2 }

   phivEndCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known circuit used to
            communicate with the remote node.  This is the same
            value as phivCircuitIndex."
        ::= { phivEndRemoteEntry 3 }

   phivEndActiveLinks OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter represents the number of active
            logical links from the executor to the destination node."
        ::= { phivEndRemoteEntry 4 }

   phivEndDelay OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter is the average round trip
            delay in seconds to the destination node. This
            parameter is kept on a remote node basis."
        ::= { phivEndRemoteEntry 5 }

   -- End System Counter Table


   phivEndCountTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivEndCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about the counters associated with each end
            system that is known to the entity. These counters
            reflect totals from the perspective of the executor
            node."
        ::= { end 2 }

   phivEndCountEntry OBJECT-TYPE
        SYNTAX PhivEndCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about a particular session between two end
            systems."
        INDEX  { phivEndCountHostNodeID }
        ::= { phivEndCountTable 1 }

   PhivEndCountEntry ::=
        SEQUENCE {
            phivEndCountHostNodeID
                PhivAddr,
            phivEndCountSecsLastZeroed
                PhivCounter,
            phivEndCountUsrBytesRec
                PhivCounter,
            phivEndCountUsrBytesSent
                PhivCounter,
            phivEndUCountUsrMessRec
                PhivCounter,
            phivEndCountUsrMessSent
                PhivCounter,
            phivEndCountTotalBytesRec
                PhivCounter,
            phivEndCountTotalBytesSent
                PhivCounter,
            phivEndCountTotalMessRec
                PhivCounter,
            phivEndCountTotalMessSent
                PhivCounter,
            phivEndCountConnectsRecd
                PhivCounter,
            phivEndCountConnectsSent
                PhivCounter,


            phivEndCountReponseTimeouts
                PhivCounter,
            phivEndCountRecdConnectResErrs
                PhivCounter
        }

   phivEndCountHostNodeID OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value is the address of the remote node to be
            evaluated."
        ::= { phivEndCountEntry 1 }

   phivEndCountSecsLastZeroed OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value is the number of seconds that have elapsed
            since the counters for the node in this table row were
            last set to zero. This counter is located in the
            network management layer, but is returned with the
            end system information which follows."
        ::= { phivEndCountEntry 2 }

   phivEndCountUsrBytesRec OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of user bytes received from the target host."
        ::= { phivEndCountEntry 3 }

   phivEndCountUsrBytesSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of user bytes sent to the target host."
        ::= { phivEndCountEntry 4 }

   phivEndUCountUsrMessRec OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION


            "Number of user messages received from the target host."
        ::= { phivEndCountEntry 5 }

   phivEndCountUsrMessSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of user messages sent to the target host."
        ::= { phivEndCountEntry 6 }

   phivEndCountTotalBytesRec OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes received from the target host."
        ::= { phivEndCountEntry 7 }

   phivEndCountTotalBytesSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes sent to the target host."
        ::= { phivEndCountEntry 8 }

   phivEndCountTotalMessRec OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of messages received from the target host."
        ::= { phivEndCountEntry 9 }

   phivEndCountTotalMessSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of messages sent to the target host."
        ::= { phivEndCountEntry 10 }

   phivEndCountConnectsRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION


            "Number of connects received from the target host."
        ::= { phivEndCountEntry 11 }

   phivEndCountConnectsSent OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of connects sent to the target host."
        ::= {phivEndCountEntry 12 }

   phivEndCountReponseTimeouts OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of response timeouts."
        ::= { phivEndCountEntry 13 }

   phivEndCountRecdConnectResErrs OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of received connect resource errors."
        ::= {phivEndCountEntry 14 }

   -- additional End System objects

   phivEndMaxLinks OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum active logical
            link count allowed for the executor."
        ::= { end 3 }

   phivEndNSPVers OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..255))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter represents the version number
            of the node End Communication S/W. The format is
            version number, ECO, and user ECO, e.g., 4.1.0"
        ::= { end 4 }


   phivEndRetransmitFactor OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of times the
            source End Communication at the executor node will
            restart the retransmission timer when it expires. If
            the number is exceeded, Session Control disconnects the
            logical link for the user."
        ::= { end 5 }

   phivEndDelayFact OBJECT-TYPE
        SYNTAX INTEGER (1..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This is the number by which to multiply one sixteenth
            of the estimated round trip delay to a node to set the
            retransmission timer to that node."
        ::= { end 6 }

   phivEndDelayWeight OBJECT-TYPE
        SYNTAX INTEGER (1..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This number represents the weight to apply to a
            current round trip delay estimate to a remote node
            when updating the estimated round trip delay to a node.
            On some systems the number must be 1 less than a power
            of 2 for computational efficiency."
        ::= { end 7 }

   phivEndInactivityTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum duration of inactivity
            (no data in either direction) on a logical link before
            the node checks to see if the logical link still works.
            If no activity occurs within the minimum number of
            seconds, End Communication generates artificial
            traffic to test the link (End Communication
            specification)."
        ::= { end 8 }


   phivEndCountZeroCount OBJECT-TYPE
        SYNTAX INTEGER {
            other (1),
            reset (2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "When this value is set to 2, all of the counters in
            the End System Counter Table are set to zero."
        ::= { end 9 }

   phivEndMaxLinksActive OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the high water mark for the
            number of links that were active at any one time."
        ::= { end 10 }

   -- Routing Layer Group

   -- The implementation of the Routing Layer Group is mandatory for
   -- all systems that implement level 1 routing layer
   -- communications.

   phivRouteBroadcastRouteTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value determines the maximum time in seconds
             allowed between Routing updates on Ethernet
             circuits. When this timer expired before a routing
             update occurs, a routing update is forced.  With a
             standard calculation, Routing also uses this timer
             to enforce a minimum delay between routing updates."
        ::= { routing 1 }

   phivRouteBuffSize OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter value determines the maximum size of
             a Routing message. It therefore determines the maximum
             size message that can be forwarded.  This size includes


             protocol overhead down to and including the End
             Communication layer, plus a constant value of 6. (This
             value of 6 is included to provide compatibility with
             the parameter definition in Phase III, which included
             the Routing overhead.) It does not include Routing or
             Data link overhead (except for the constant value of
             6). There is one buffer size for all circuits.

             NOTE: The BUFFER SIZE defines the maximum size messages
             that the Routing layer can forward. The SEGMENT BUFFER
             SIZE (defined below) defines the maximum size messages
             that the End Communication layer can transmit or
             receive. The SEGMENT BUFFER SIZE is always less than
             or equal to the BUFFER SIZE. Normally the two
             parameters will be equal. They may be different to
             allow the network manager to alter buffer sizes
             on all nodes without interruption of service. They both
             include an extra 6 bytes for compatibility with Phase
             III."
        ::= { routing 2 }

   phivRouteRoutingVers OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..255))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter identifies the executor node's
            Routing version number.  The format is version number,
            ECO, and user ECO, e.g., 4.1.0"
        ::= { routing 3 }

   phivRouteMaxAddr OBJECT-TYPE
        SYNTAX INTEGER (1..1023)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the largest node number and,
            therefore, number of nodes that can be known about
            by the executor node's home area."
        ::= { routing 4 }

   phivRouteMaxBdcastNonRouters OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum total number of
            nonrouters the executor node can have on its Ethernet


            circuits."
        ::= { routing 5 }

   phivRouteMaxBdcastRouters OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum total number of
            routers the executor node can have on its Ethernet
            circuits."
        ::= { routing 6 }

   phivRouteMaxBuffs OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of transmit
            buffers that Routing may use for all circuits."
        ::= { routing 7 }

   phivRouteMaxCircuits OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of Routing
            circuits that the executor node can know about."
        ::= { routing 8 }

   phivRouteMaxCost OBJECT-TYPE
        SYNTAX INTEGER (1..1022)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum total path cost
            allowed from the executor to any node within an area.
            The path cost is the sum of the circuit costs along
            a path between two nodes. This parameter defines the
            point where the executor node's Routing routing
            decision algorithm declares another node unreachable
            because the cost of the least costly path to the
            other node is excessive. For correct operation, this
            parameter must not be less than the maximum path cost
            of the network."
        ::= { routing 9 }


   phivRouteMaxHops OBJECT-TYPE
        SYNTAX INTEGER (1..30)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of routing hops
            allowable from the executor to any other reachable node
            within an area. (A hop is the logical distance over a
            circuit between two adjacent nodes.) This parameter
            defines the point where the executor node's Routing
            routing decision algorithm declares another node
            unreachable because the length of the shortest path
            between the two nodes is too long. For correct
            operation, this parameter must not be less than the
            network diameter. (The network diameter is the
            reachability distance between the two nodes of the
            network having the greatest reachability distance,
            where reachability distance is the length the shortest
            path between a given pair of nodes.)"
        ::= { routing 10 }

   phivRouteMaxVisits OBJECT-TYPE
        SYNTAX INTEGER (1..63)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of nodes a
            message coming into the executor node can have visited.
            If the message is not for this node and the MAXIMUM
            VISITS number is exceeded, the message is discarded.
            The MAXIMUM VISITS parameter defines the point where
            the packet lifetime control algorithm discards
            a packet that has traversed too many nodes. For correct
            operation, this parameter must not be less than the
            maximum path length of the network. (The maximum path
            length is the routing distance between the two nodes of
            the network having the greatest routing distance, where
            routing distance is the length of the least costly
            path between a given pair of nodes.)"
        ::= { routing 11 }

   phivRouteRoutingTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value determines the maximum time in seconds
            allowed between Routing updates on non-Ethernet


            circuits. When this timer expires before a routing
            update occurs, a routing update is forced."
        ::= { routing 12 }

   phivRouteSegBuffSize OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter value determines the maximum size of an
            end-to-end segment. The size is a decimal integer in
            the range 1-65535. This size is in bytes. This size
            includes protocol overhead down to and including the
            End Communication layer, plus a constant value of 6.
            (This value of 6 is included to provide compatibility
            with the BUFFER SIZE parameter definition.) It does not
            include Routing or Data link overhead (except for the
            constant value of 6)."
        ::= { routing 13 }

   phivRouteType OBJECT-TYPE
        SYNTAX INTEGER {
            routing-III (1),
            nonrouting-III (2),
            area (3),
            routing-IV (4),
            nonrouting-IV (5)
        }
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter indicates the type of the executor
            node. The node-type is one of the following:

            routing-III
            nonrouting-III
            routing-IV
            ronrouting-IV
            area

            A routing node has full routing capability. A
            nonrouting node contains a subset of the Routing
            routing modules. The III and IV indicate the DNA
            phase of the node. Nonrouting nodes can deliver
            and receive packets to and from any node, but cannot
            route packets from other nodes through to other nodes.
            An area node routes between areas. Refer to the Routing
            specification for details.


            For adjacent nodes, this is a read-only parameter that
            indicates the type of the reachable adjacent node.
            NOTE: The ROUTING-III and NONROUTING-III values are
            incremented by one compared to the standard DECnet
            values in order to maintain compliance with RFC 1155)"
        ::= { routing 14 }

   phivRouteCountAgedPktLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of aged packet losses."
        ::= { routing 15 }

   phivRouteCountNodeUnrPktLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of node unreachable packet losses."
        ::= { routing 16 }

   phivRouteCountOutRngePktLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of node out-of-range packet losses."
        ::= { routing 17 }

   phivRouteCountOverSzePktLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of Oversized packet losses."
        ::= { routing 18 }

   phivRouteCountPacketFmtErr OBJECT-TYPE
        SYNTAX PhivCounter (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of packet format errors."
        ::= { routing 19 }


   phivRouteCountPtlRteUpdtLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of partial routing update losses."
        ::= { routing 20 }

   phivRouteCountVerifReject OBJECT-TYPE
        SYNTAX PhivCounter (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of verification rejects."
        ::= { routing 21 }

   -- Level 1 Routing Table

   phivLevel1RouteTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivLevel1RouteEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about the currently known DECnet Phase
            IV Routes."
        ::= { routing 22 }

   phivLevel1RouteEntry OBJECT-TYPE
        SYNTAX PhivLevel1RouteEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about the currently known DECnet Phase
            IV Routes."
        INDEX  { phivLevel1RouteNodeAddr }
        ::= { phivLevel1RouteTable 1 }

   PhivLevel1RouteEntry ::=
        SEQUENCE {
            phivLevel1RouteNodeAddr
                PhivAddr,
            phivLevel1RouteCircuitIndex
                INTEGER,
            phivLevel1RouteCost
                INTEGER,
            phivLevel1RouteHops
                INTEGER,
            phivLevel1RouteNextNode


                PhivAddr
        }

   phivLevel1RouteNodeAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value is the address of the node about which
            routing information is contained in this level 1
            routing table."
        ::= { phivLevel1RouteEntry 1 }

   phivLevel1RouteCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known circuit. This is
            the index to the circuit state table and is the same
            value as phivCircuitIndex."
        ::= { phivLevel1RouteEntry 2 }

   phivLevel1RouteCost OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter represents the total cost
            over the current path to the destination node. Cost is
            a positive integer value associated with using a
            circuit. Routing routes messages (data) along the path
            between two nodes with the smallest cost. COST is kept
            on a remote node basis."
        ::= { phivLevel1RouteEntry 3 }

   phivLevel1RouteHops OBJECT-TYPE
        SYNTAX INTEGER (0..127)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter represents the number of hops
            over to a destination node. A hop is Routing value
            representing the logical distance between two nodes in
            a network. HOPS is kept on a remote node basis."
        ::= { phivLevel1RouteEntry 4 }

   phivLevel1RouteNextNode OBJECT-TYPE


        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only value indicates the next node on the
            circuit used to get to the node under scrutiny
            (next hop)."
        ::= { phivLevel1RouteEntry 5 }

   -- Additional routing parameters

   phivRouteCountZeroCount OBJECT-TYPE
        SYNTAX INTEGER {
            other (1),
            reset (2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "When this value is set to 2, the following objects are
            set to Zero: phivRouteCountAgedPktLoss,
            phivRouteCountNodeUnrPktLoss,
            phivRouteCountOutRngePktLoss,
            phivRouteCountOverSzePktLoss,
            phivRouteCountPacketFmtErr,
            phivRouteCountPtlRteUpdtLoss, and
            phivRouteCountVerifReject."
        ::= { routing 23 }

   phivRouteSystemAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "DECnet Phase IV node address."
        ::= { routing 24 }

   phivRouteRoutingType OBJECT-TYPE
        SYNTAX INTEGER {
            routing-III (1),
            nonrouting-III (2),
            area (3),
            routing-IV (4),
            nonrouting-IV (5)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION


            "This read-write parameter indicates the type of the executor
            node. The node-type is one of the following:

            routing-III
            nonrouting-III
            routing-IV
            ronrouting-IV
            area

            A routing node has full routing capability. A
            nonrouting node contains a subset of the Routing
            routing modules. The III and IV indicate the DNA
            phase of the node. Nonrouting nodes can deliver
            and receive packets to and from any node, but cannot
            route packets from other nodes through to other nodes.
            An area node routes between areas. Refer to the Routing
            specification for details.

            For adjacent nodes, this is a read-only parameter that
            indicates the type of the reachable adjacent node.
            NOTE: The ROUTING-III and NONROUTING-III values are
            incremented by one compared to the standard DECnet
            values in order to maintain compliance with RFC 1155)"
        ::= { routing 25 }

   phivRouteSystemAddress OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "DECnet Phase IV node address."
        ::= { routing 26 }

   -- Circuit Group

   -- The implementation of the Circuit Group is mandatory for
   -- all systems.

   -- Circuit Parameters Table

   phivCircuitParametersTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivCircuitParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about the parameters associated with all
            circuits currently known."
        ::= {circuit 1 }


   phivCircuitParametersEntry OBJECT-TYPE
        SYNTAX PhivCircuitParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Parameters information about all circuits currently
             known."
        INDEX  { phivCircuitIndex }
        ::= { phivCircuitParametersTable 1 }

   PhivCircuitParametersEntry ::=
        SEQUENCE {
            phivCircuitIndex
                INTEGER,
            phivCircuitLineIndex
                INTEGER,
            phivCircuitCommonState
                INTEGER,
            phivCircuitCommonSubState
                INTEGER,
            phivCircuitCommonName
                DisplayString,
            phivCircuitExecRecallTimer
                INTEGER,
            phivCircuitCommonType
                INTEGER,
            phivCircuitService
                INTEGER,
            phivCircuitExecCost
                INTEGER,
            phivCircuitExecHelloTimer
                INTEGER
       }

   phivCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known circuit."
        ::= { phivCircuitParametersEntry 1 }

   phivCircuitLineIndex OBJECT-TYPE
        SYNTAX InterfaceIndex
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The line on which this circuit is active.  This is


             the same as the ifIndex."
        ::= { phivCircuitParametersEntry 2 }

   phivCircuitCommonState OBJECT-TYPE
        SYNTAX INTEGER {
            on (1),
            off (2),
            service (3),
            cleared (4)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the circuit's Network Management
            operational state. NOTE: These values are incremented
            by one compared to the standard DECnet values in order
            to maintain compliance with RFC 1155."
        ::= { phivCircuitParametersEntry 3 }

   phivCircuitCommonSubState OBJECT-TYPE
        SYNTAX INTEGER {
            starting (1),
            reflecting (2),
            looping (3),
            loading (4),
            dumping (5),
            triggering (6),
            autoservice (7),
            autoloading (8),
            autodumping (9),
            autotriggering (10),
            synchronizing (11),
            failed (12),
            running (13)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the circuit's Network Management
            operational and service substate. NOTE: These values are
            incremented by one compared to the standard DECnet values
            in order to maintain compliance with RFC 1155."
        ::= { phivCircuitParametersEntry 4 }

   phivCircuitCommonName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..16))
        ACCESS read-only
        STATUS mandatory


        DESCRIPTION
            "The name of the circuit entry in the table, for example,
             SVA-0 or in a level 2 router ASYNC-8 or ETHER-1)."
        ::= { phivCircuitParametersEntry 5 }

   phivCircuitExecRecallTimer OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter represents the minimum number of
            seconds to wait before restarting the circuit.  A
            value of 0 indicates not timer is running."
        ::= { phivCircuitParametersEntry 6 }

   phivCircuitCommonType OBJECT-TYPE
        SYNTAX INTEGER {
            ddcmp-point (1),
            ddcmp-control (2),
            ddcmp-tributary (3),
            x25 (4),
            ddcmp-dmc (5),
            ethernet (6),
            ci (7),
            qp2-dte20 (8),
            bisync (9),
            other (14),
            fddi (15)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Represents the type of the circuit. For X.25 circuits,
            the value must be set to X25. For DDCMP and Ethernet
            circuits it is read only and is the same value as the
            protocol of the associated line.
            NOTE: Values 1 - 5 are incremented by one compared to the
            standard DECnet values in order to maintain compliance
            with RFC 1155."
        ::= { phivCircuitParametersEntry 7 }

   phivCircuitService  OBJECT-TYPE
        SYNTAX INTEGER {
            enabled (1),
            disabled (2)
        }
        ACCESS read-write
        STATUS mandatory


        DESCRIPTION
            "This value indicates whether or not Network Management
            allows service operations on a circuit. The values for
            service-control are as follows:

            ENABLED     SERVICE state and/or service functions are
                        allowed.

            DISABLED    SERVICE state and/or service functions are not
                        allowed.

            NOTE: These values are incremented by one compared to the
            standard DECnet values in order to maintain compliance
            with RFC 1155."
        ::= { phivCircuitParametersEntry 8 }

   phivCircuitExecCost OBJECT-TYPE
        SYNTAX INTEGER (1..25)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the routing cost of the circuit.
            Routing sends messages along the path between two nodes
            having the smallest cost."
        ::= { phivCircuitParametersEntry 9 }

   phivCircuitExecHelloTimer OBJECT-TYPE
        SYNTAX INTEGER (1..8191)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value determines the frequency of Routing Hello
            messages sent to the adjacent node on the circuit."
        ::= { phivCircuitParametersEntry 10 }

   -- Circuit Counters Table

   phivCircuitCountTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivCircuitCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about the counters associated with all
            circuits currently known."
        ::= { circuit 2 }

          phivCircuitCountEntry OBJECT-TYPE
        SYNTAX PhivCircuitCountEntry


        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Counter information about all circuits currently known"
        INDEX     { phivCircuitIndex }
        ::= { phivCircuitCountTable 1 }

   PhivCircuitCountEntry ::=
        SEQUENCE {
            phivCircuitCountSecLastZeroed
                PhivCounter,
            phivCircuitCountTermPacketsRecd
                PhivCounter,
            phivCircuitCountOriginPackSent
                PhivCounter,
            phivCircuitCountTermCongLoss
                PhivCounter,
            phivCircuitCountCorruptLoss
                PhivCounter,
            phivCircuitCountTransitPksRecd
                PhivCounter,
            phivCircuitCountTransitPkSent
                PhivCounter,
            phivCircuitCountTransitCongestLoss
                PhivCounter,
            phivCircuitCountCircuitDown
                PhivCounter,
            phivCircuitCountInitFailure
                PhivCounter,
            phivCircuitCountAdjDown
                PhivCounter,
            phivCircuitCountPeakAdj
                PhivCounter,
            phivCircuitCountBytesRecd
                PhivCounter,
            phivCircuitCountBytesSent
                PhivCounter,
            phivCircuitCountDataBlocksRecd
                PhivCounter,
            phivCircuitCountDataBlocksSent
                PhivCounter,
            phivCircuitCountUsrBuffUnav
                PhivCounter
        }

   phivCircuitCountSecLastZeroed  OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only


        STATUS mandatory
        DESCRIPTION
            "Number of seconds since the circuit counters for this
            circuit were last zeroed."
        ::= { phivCircuitCountEntry 1 }

   phivCircuitCountTermPacketsRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of terminating packets received on this circuit."
        ::= { phivCircuitCountEntry 2 }

   phivCircuitCountOriginPackSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of originating packets sent on this circuit."
        ::= { phivCircuitCountEntry 3 }

   phivCircuitCountTermCongLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of terminating congestion losses on this
            circuit."
        ::= { phivCircuitCountEntry 4 }

   phivCircuitCountCorruptLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of corruption losses on this circuit."
        ::= { phivCircuitCountEntry 5 }

   phivCircuitCountTransitPksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of Transit packets received on this circuit."
        ::= { phivCircuitCountEntry 6 }

   phivCircuitCountTransitPkSent OBJECT-TYPE


        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of transit packets sent on this circuit."
        ::= { phivCircuitCountEntry 7 }

   phivCircuitCountTransitCongestLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of transit congestion losses on this circuit."
        ::= { phivCircuitCountEntry 8 }

   phivCircuitCountCircuitDown OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of circuit downs on this circuit."
        ::= { phivCircuitCountEntry 9 }

   phivCircuitCountInitFailure OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of Initialization failures on this circuit."
        ::= { phivCircuitCountEntry 10 }

   phivCircuitCountAdjDown OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This counter indicates the number of adjacency losses
            that result from any of the following:
                 Node listener timeout
                 Invalid data received at node listener
                 Unexpected control (initialization or verification)
                     message received
                 Routing message received with a checksum error
                 Node identification from a routing message or a
                 Hello message that is not the one expected Hello
                 message received indicating that connectivity
                 became one-way
                 Adjacency idled."


        ::= { phivCircuitCountEntry 11 }

   phivCircuitCountPeakAdj OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This counter indicates the maximum number of nodes
            that are up on the circuit."
        ::= { phivCircuitCountEntry 12 }

   phivCircuitCountBytesRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes received on this circuit."
        ::= { phivCircuitCountEntry 13 }

   phivCircuitCountBytesSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes sent on this circuit."
        ::= { phivCircuitCountEntry 14 }

   phivCircuitCountDataBlocksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data blocks received on this circuit."
        ::= { phivCircuitCountEntry 15 }

   phivCircuitCountDataBlocksSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data blocks sent on this circuit."
        ::= { phivCircuitCountEntry 16 }

   phivCircuitCountUsrBuffUnav OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION


            "Number of user buffer unavailable errors."
        ::= { phivCircuitCountEntry 17 }

   -- Additional Circuit Parameters

   phivCircuitOrigQueueLimit OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter indicates the maximum number of
            originating packets that may be outstanding on this
            circuit. This does not include route-thru traffic."
        ::= { circuit 3 }

   phivCircuitCountZeroCount OBJECT-TYPE
        SYNTAX INTEGER {
            other (1),
            reset (2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "When this value is set to 2, all of the counters in the
            Circuit Counter Table are set to zero."
        ::= { circuit 4 }

   -- DDCMP Circuit Group

   -- The implementation of the DDCMP Circuit Group is optional.
   -- A system can be said to implement this group if and only if
   -- all objects in this group are implemented.

   -- DDCMP Parameters Table

   phivDDCMPCircuitParametersTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about DDCMP circuit parameters."
        ::= { ddcmp 1}

   phivDDCMPCircuitParametersEntry OBJECT-TYPE
        SYNTAX PhivDDCMPCircuitParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION


            "Parameters information about DDCMP circuits currently
             known."
        INDEX     { phivDDCMPCircuitIndex }
        ::= { phivDDCMPCircuitParametersTable 1 }

   PhivDDCMPCircuitParametersEntry ::=
        SEQUENCE {
            phivDDCMPCircuitIndex
                INTEGER,
            phivDDCMPCircuitAdjNodeAddr
                INTEGER,
            phivDDCMPCircuitTributary
                INTEGER
        }

   phivDDCMPCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known DDCMP circuit.
            This is the same value as phivCircuitIndex."
        ::= { phivDDCMPCircuitParametersEntry 1 }

   phivDDCMPCircuitAdjNodeAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The address of the adjacent node."
        ::= { phivDDCMPCircuitParametersEntry 2 }

   phivDDCMPCircuitTributary OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the Data Link physical tributary
            address of the circuit."
        ::= { phivDDCMPCircuitParametersEntry 3 }

   -- DDCMP Circuit Counter Table

   phivDDCMPCircuitCountTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivDDCMPCircuitCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION


            "Information about the DDCMP counters associated with all
            circuits currently known."
        ::= { ddcmp 2 }

   phivDDCMPCircuitCountEntry OBJECT-TYPE
        SYNTAX PhivDDCMPCircuitCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Counter information about DDCMP circuits now known"
        INDEX     { phivCircuitIndex }
        ::= { phivDDCMPCircuitCountTable 1 }

   PhivDDCMPCircuitCountEntry ::=
        SEQUENCE {
            phivDDCMPCircuitErrorsInbd
                PhivCounter,
            phivDDCMPCircuitErrorsOutbd
                PhivCounter,
            phivDDCMPCircuitRmteReplyTimeouts
                PhivCounter,
            phivDDCMPCircuitLocalReplyTimeouts
                PhivCounter,
            phivDDCMPCircuitRmteBuffErrors
                PhivCounter,
            phivDDCMPCircuitLocalBuffErrors
                PhivCounter,
            phivDDCMPCircuitSelectIntervalsElap
                PhivCounter,
            phivDDCMPCircuitSelectTimeouts
                PhivCounter
        }

   phivDDCMPCircuitErrorsInbd OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of Data errors inbound."
        ::= { phivDDCMPCircuitCountEntry 1 }

   phivDDCMPCircuitErrorsOutbd OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of outbound data errors."
        ::= { phivDDCMPCircuitCountEntry 2 }


   phivDDCMPCircuitRmteReplyTimeouts OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of remote reply timeouts."
        ::= { phivDDCMPCircuitCountEntry 3 }

   phivDDCMPCircuitLocalReplyTimeouts OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of local Reply timeouts."
        ::= { phivDDCMPCircuitCountEntry 4 }

   phivDDCMPCircuitRmteBuffErrors OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of remote reply time out errors."
        ::= { phivDDCMPCircuitCountEntry 5 }

   phivDDCMPCircuitLocalBuffErrors  OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of local buffer errors."
        ::= { phivDDCMPCircuitCountEntry 6 }

   phivDDCMPCircuitSelectIntervalsElap OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Selection intervals that have elapsed."
        ::= {phivDDCMPCircuitCountEntry 7 }

   phivDDCMPCircuitSelectTimeouts OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of selection timeouts."
        ::= {phivDDCMPCircuitCountEntry 8 }


   -- DDCMP Line Count Table

   phivDDCMPLineCountTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivDDCMPLineCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "The DDCMP Line Count Table."
        ::= { ddcmp 3 }

   phivDDCMPLineCountEntry OBJECT-TYPE
        SYNTAX PhivDDCMPLineCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "There is one entry in the table for each line."
        INDEX  { phivDDCMPLineCountIndex }
        ::= { phivDDCMPLineCountTable 1 }

   PhivDDCMPLineCountEntry ::=
        SEQUENCE {
            phivDDCMPLineCountIndex
                InterfaceIndex,
            phivDDCMPLineCountDataErrsIn
                PhivCounter,
            phivDDCMPLineCountRmteStationErrs
                PhivCounter,
            phivDDCMPLineCountLocalStationErrs
                PhivCounter
        }

   phivDDCMPLineCountIndex OBJECT-TYPE
        SYNTAX InterfaceIndex
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The line on which this entry's equivalence is
            effective. The interface identified by a particular
            value of this index is the same interface as
            identified by the same value of phivLineIndex.
            This value is the ifIndex."
        ::= { phivDDCMPLineCountEntry 1 }

   phivDDCMPLineCountDataErrsIn OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory


        DESCRIPTION
            "Number of data errors inbound."
        ::= { phivDDCMPLineCountEntry 2 }

   phivDDCMPLineCountRmteStationErrs OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of remote station errors."
        ::= { phivDDCMPLineCountEntry 3 }

   phivDDCMPLineCountLocalStationErrs OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
             "Number of local station errors."
        ::= { phivDDCMPLineCountEntry 4 }

   -- DDCMP Multipoint Circuit Control Group

   -- The implementation of the DDCMP Multipoint Circuit Control
   -- Group is optional.  A system can be said to implement this group
   -- if and only if all objects in this group are implemented.

   phivControlSchedTimer OBJECT-TYPE
        SYNTAX INTEGER (50..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of milliseconds
            between recalculation of tributary polling priorities."
        DEFVAL { 200 }
        ::= { control 1 }

   phivControlDeadTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of milliseconds
            between polls of one of the set of dead
            tributaries."
        DEFVAL { 10000 }
        ::= { control 2 }

   phivControlDelayTimer OBJECT-TYPE


        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the minimum number of
            milliseconds to delay between polls. The delay timer
            limits the effect of a very fast control station on
            slow tributaries."
        ::= { control 3 }

   phivControlStreamTimer OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of milliseconds a
            tributary or a half duplex remote station is
            allowed to hold the line.

            NOTE: This parameter can also be applied to
            half-duplex lines of type DDCMP POINT."
        DEFVAL { 6000 }
        ::= { control 4 }

   -- DDCMP Multipoint Circuit Control Parameters Table

   phivControlParametersTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivControlParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about control circuit parameters."
        ::= { control 5 }

   phivControlParametersEntry OBJECT-TYPE
        SYNTAX PhivControlParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Parameters information about control circuits
            currently known."
        INDEX  { phivControlCircuitIndex }
        ::= { phivControlParametersTable 1 }

   PhivControlParametersEntry ::=
        SEQUENCE {
            phivControlCircuitIndex
                INTEGER,


            phivControlBabbleTimer
                INTEGER,
            phivControlMaxBuffs
                INTEGER,
            phivControlMaxTransmits
                INTEGER,
            phivControlDyingBase
                INTEGER,
            phivControlDyingIncrement
                INTEGER,
            phivControlDeadThreshold
                INTEGER,
            phivControlDyingThreshold
                INTEGER,
            phivControlInactTreshold
                INTEGER,
            phivControlPollingState
                INTEGER,
            phivControlPollingSubState
                INTEGER,
            phivControlTransTimer
                INTEGER
        }

   phivControlCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known multipoint
            control circuit.
            This is the same value as phivCircuitIndex."
        ::= { phivControlParametersEntry 1 }

   phivControlBabbleTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of milliseconds that a
            selected tributary or remote half-duplex station is
            allowed to transmit."
        DEFVAL { 6000 }
        ::= { phivControlParametersEntry 2 }

   phivControlMaxBuffs  OBJECT-TYPE
        SYNTAX INTEGER (1..254)
        ACCESS read-write


        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of buffers the
            tributary can use from a common buffer pool. If not
            set, there is no common buffer pool and buffers are
            explicitly supplied by the higher level. Count is a
            decimal integer in the range 1-254."
        ::= { phivControlParametersEntry 3 }

   phivControlMaxTransmits  OBJECT-TYPE
        SYNTAX INTEGER (1..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of data
            messages that can be transmitted at one time. Count
            is a decimal integer in the range 1-255."
        DEFVAL { 4 }
        ::= { phivControlParametersEntry 4 }

   phivControlDyingBase OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the base priority to which a
            tributary is reset each time it has been polled. A
            separate base can be set for each of the indicated
            polling states. Base is a decimal integer in the range
            0-255.  If not set, the defaults are: active, 255;
            inactive, 0; and dying, 0."
        ::= { phivControlParametersEntry 5 }

   phivControlDyingIncrement OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the increment added to the
            tributary priority each time the scheduling timer
            expires.  If not set, the defaults are: active, 0;
            inactive, 64; and dying, 16."
        ::= { phivControlParametersEntry 6 }

   phivControlDeadThreshold OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory


        DESCRIPTION
            "This value represents the number of times to poll the
            active, inactive, or dying tributary before changing
            its polling state to dead because of receive timeouts.
            Count is a decimal integer in the range 0-255."
        DEFVAL { 8 }
        ::= { phivControlParametersEntry 7 }

   phivControlDyingThreshold OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of times to poll the
            active or inactive tributary before changing its
            polling state to dying because of receive timeouts.
            Count is a decimal integer in the range 0-255."
        DEFVAL { 2 }
        ::= { phivControlParametersEntry 8 }

   phivControlInactTreshold OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of times to poll the
            active tributary before changing its polling state to
            inactive because of no data response. Count is a
            decimal integer in the range
            0-255."
        DEFVAL { 8 }
        ::= { phivControlParametersEntry 9 }

   phivControlPollingState OBJECT-TYPE
        SYNTAX INTEGER {
            automatic (1),
            active (2),
            inactive (3),
            dying (4),
            dead (5)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the state of the tributary
            relative to the multipoint polling algorithm.  If not
            set the default is AUTOMATIC. The possible states are:


            AUTOMATIC

              The tributary's state is allowed to vary according to
              the operation of the polling algorithm.

            ACTIVE/INACTIVE/DYING/DEAD

              The tributary is locked in the specified state.

             NOTE: These values are incremented by one compared to
             the standard DECnet values in order to maintain
             compliance with RFC 1155."
        ::= { phivControlParametersEntry 10 }

   phivControlPollingSubState OBJECT-TYPE
        SYNTAX INTEGER {
            active (1),
            inactive (2),
            dying (3),
            dead (4)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the tributary's state as
            determined by the polling algorithm.  This applies
            only when the polling state is AUTOMATIC and is
            read-only to Network Management.  Polling-substate is
            one of ACTIVE, INACTIVE, DYING, or DEAD.  It is
            displayed as a tag on the polling state, for example:
            AUTOMATIC-INACTIVE."
        ::= { phivControlParametersEntry 11 }

   phivControlTransTimer OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of milliseconds to
            delay between data message transmits. Milliseconds is
            a decimal integer in the range 0-65535."
        DEFVAL { 0 }
        ::= { phivControlParametersEntry 12 }

   -- Ethernet Group

   -- The implementation of the Ethernet Group is mandatory
   -- for all systems which support ethernet links.


   -- Ethernet Parameters Table

   phivEthLinkParametersTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivEthLinkParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
             "Information about ethernet link parameters."
        ::= { ethernet 1}

   phivEthLinkParametersEntry OBJECT-TYPE
        SYNTAX PhivEthLinkParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Parameter information about ethernet links currently
            known."
        INDEX     { phivEthLinkIndex }
        ::= { phivEthLinkParametersTable 1 }

   PhivEthLinkParametersEntry ::=
        SEQUENCE {
            phivEthLinkIndex
                INTEGER,
            phivEthDesigRouterNodeAddr
                PhivAddr,
            phivEthMaxRouters
                INTEGER,
            phivEthRouterPri
                INTEGER,
            phivEthHardwareAddr
                OCTET STRING
         }

   phivEthLinkIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The circuit over which this links information is
            collected.  This is the same as phivCircuitIndex."
        ::= { phivEthLinkParametersEntry 1 }

   phivEthDesigRouterNodeAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory


        DESCRIPTION
            "This value is the address of the designated router."
        ::= { phivEthLinkParametersEntry 2 }

   phivEthMaxRouters OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter is the maximum number of routers (other
             than the executor itself) allowed on the circuit by
             Routing for circuits that are owned by the executor
             node."
        ::= { phivEthLinkParametersEntry 3 }

   phivEthRouterPri OBJECT-TYPE
        SYNTAX INTEGER (0..127)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter is the priority that this router is to
             have in the selection of designated router for the
             circuit on circuits that are owned by the executor
             node."
        DEFVAL { 64 }
        ::= { phivEthLinkParametersEntry 4 }

   phivEthHardwareAddr OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (6))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter is the address that is
            associated with the line device hardware as seen by
            the DECnet Software.  This value is not the same as
            ifPhysAddress."
        ::= { phivEthLinkParametersEntry 5 }

   -- Counters Group

   -- The implementation of the Counters Group is optional.
   -- A system can be said to implement this group if and only if
   -- all objects in this group are implemented.

   -- Counters Table

   phivCountersCountTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivCountersCountEntry


        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about ethernet link counters."
        ::= { counters 1 }

   phivCountersCountEntry OBJECT-TYPE
        SYNTAX PhivCountersCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Counter information about ethernet links currently
            known."
        INDEX     { phivCountersIndex }
        ::= { phivCountersCountTable 1 }

   PhivCountersCountEntry ::=
        SEQUENCE {
            phivCountersIndex
                InterfaceIndex,
            phivCountersCountBytesRecd
                PhivCounter,
            phivCountersCountBytesSent
                PhivCounter,
            phivCountersCountDataBlocksRecd
                PhivCounter,
            phivCountersCountDataBlocksSent
                PhivCounter,
            phivCountersCountEthUsrBuffUnav
                PhivCounter,
            phivCountersCountMcastBytesRecd
                PhivCounter,
            phivCountersCountDataBlksRecd
                PhivCounter,
            phivCountersCountDataBlksSent
                PhivCounter,
            phivCountersCountMcastBlksRecd
                PhivCounter,
            phivCountersCountBlksSentDef
                PhivCounter,
            phivCountersCountBlksSentSingleCol
                PhivCounter,
            phivCountersCountBlksSentMultCol
                PhivCounter,
            phivCountersCountSendFailure
                PhivCounter,
            phivCountersCountCollDetectFailure
                PhivCounter,


            phivCountersCountReceiveFailure
                PhivCounter,
            phivCountersCountUnrecFrameDest
                PhivCounter,
            phivCountersCountDataOver
                PhivCounter,
            phivCountersCountSysBuffUnav
                PhivCounter,
            phivCountersCountUsrBuffUnav
                PhivCounter
         }

   phivCountersIndex OBJECT-TYPE
        SYNTAX InterfaceIndex
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The interface to which these counters apply.  This is
            the same interface as identified by the same value of
            phivLineIndex. This value is the ifIndex."
        ::= { phivCountersCountEntry 1 }

   phivCountersCountBytesRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes received over this link."
        ::= { phivCountersCountEntry 2 }

   phivCountersCountBytesSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes sent over this link."
        ::= { phivCountersCountEntry 3 }

   phivCountersCountDataBlocksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "Number of data blocks received over this link."
        ::= { phivCountersCountEntry 4 }

   phivCountersCountDataBlocksSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)


        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "Number of data blocks sent over this link."
        ::= { phivCountersCountEntry 5 }

   phivCountersCountEthUsrBuffUnav OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of user buffer unavailable errors over this
            link."
        ::= { phivCountersCountEntry 6 }

   phivCountersCountMcastBytesRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of multicast bytes received over this link."
        ::= { phivCountersCountEntry 7 }

   phivCountersCountDataBlksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data blocks received over this link."
        ::= { phivCountersCountEntry 8 }

   phivCountersCountDataBlksSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data blocks sent over this link."
        ::= { phivCountersCountEntry 9 }

   phivCountersCountMcastBlksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of multicast blocks received over this link."
        ::= { phivCountersCountEntry 10 }

   phivCountersCountBlksSentDef OBJECT-TYPE


        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of blocks sent, initially deferred over this
            link."
        ::= { phivCountersCountEntry 11 }

   phivCountersCountBlksSentSingleCol OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of blocks sent, single collision over this link."
        ::= { phivCountersCountEntry 12 }

   phivCountersCountBlksSentMultCol OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of blocks sent, multiple collisions over this
            link."
        ::= { phivCountersCountEntry 13 }

   phivCountersCountSendFailure OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of send failures over this link."
        ::= { phivCountersCountEntry 14 }

   phivCountersCountCollDetectFailure OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of collision detect check failures over this
             link."
        ::= { phivCountersCountEntry 15 }

   phivCountersCountReceiveFailure OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of receive failures over this link."


        ::= { phivCountersCountEntry 16 }

   phivCountersCountUnrecFrameDest OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of unrecognized frame destinations over this
            link."
        ::= { phivCountersCountEntry 17 }

   phivCountersCountDataOver OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data overruns over this link."
        ::= { phivCountersCountEntry 18 }

   phivCountersCountSysBuffUnav OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of system buffer unavailables over this link."
        ::= { phivCountersCountEntry 19 }

   phivCountersCountUsrBuffUnav OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of user buffer unavailables."
        ::= { phivCountersCountEntry 20 }

   -- Adjacency Group

   -- The implementation of the Adjacency Group is mandatory for all
   -- conformant implementations of this memo.

   -- The phivAdjTable has been made obsolete it has been replaced with
   -- the phivAdjNodeTable.

   phivAdjTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivAdjEntry
        ACCESS not-accessible
        STATUS obsolete
        DESCRIPTION


            "The Adjacency Table."
        ::= { adjacency 1 }

   phivAdjEntry OBJECT-TYPE
        SYNTAX PhivAdjEntry
        ACCESS not-accessible
        STATUS obsolete
        DESCRIPTION
            "There is one entry in the table for each adjacency."
        INDEX  { phivAdjCircuitIndex }
        ::= { phivAdjTable 1 }

   PhivAdjEntry ::=
        SEQUENCE {
            phivAdjCircuitIndex
                INTEGER,
            phivAdjNodeAddr
                PhivAddr,
            phivAdjBlockSize
                INTEGER,
            phivAdjListenTimer
                INTEGER (1..65535),
            phivAdjCircuitEtherServPhysAddr
                OCTET STRING,
            phivAdjType
                INTEGER,
            phivAdjState
                INTEGER,
            phivAdjPriority
                INTEGER,
            phivAdjExecListenTimer
                INTEGER (1..65535)
         }
   phivAdjCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "A unique index value for each known circuit."
        ::= { phivAdjEntry 1 }

   phivAdjNodeAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "The address of the adjacent node."
        ::= { phivAdjEntry 2 }


   phivAdjBlockSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This read-only parameter is the block size that was
            negotiated with the adjacent Routing layer during Routing
            initialization over a particular circuit. It includes the
            routing header, but excludes the data link header. This
            parameter is qualified by ADJACENT NODE."
        ::= { phivAdjEntry 3 }

   phivAdjListenTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This value determines the maximum number of seconds
            allowed to elapse before Routing receives some message
            (either a Hello message or a user message) from the
            adjacent node on the circuit. It was agreed during
            Routing initialization with the adjacent Routing layer.
            This parameter is qualified by ADJACENT NODE."
        ::= { phivAdjEntry 4 }

   phivAdjCircuitEtherServPhysAddr OBJECT-TYPE
        SYNTAX OCTET STRING ( SIZE (6) )
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This parameter indicates the Ethernet physical address
            of an adjacent node that is being serviced on this
            circuit. This parameter is a qualifier for SERVICE
            SUBSTATE."
        ::= { phivAdjEntry 5 }

   phivAdjType OBJECT-TYPE
        SYNTAX INTEGER {
            routing-III (1),
            nonrouting-III (2),
            area (3),
            routing-IV (4),
            nonrouting-IV (5)
        }
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION


            "This parameter indicates the type of adjacency.

            For adjacent nodes, this is a read-only parameter that
            indicates the type of the reachable adjacent node.
            NOTE: The routing-III and nonrouting-III values are
            incremented by one compared to the standard DECnet
            values in order to maintain compliance with RFC 1155)"
        ::= { phivAdjEntry 6 }

   phivAdjState OBJECT-TYPE
        SYNTAX INTEGER {
            initializing (1),          -- Ethernet one-way
            up (2),                    -- Ethernet two-way
            run (3),                   -- The eight DDCMP/X.25 states
            circuit-rejected (4),
            data-link-start (5),
            routing-layer-initialize (6),
            routing-layer-verify (7),
            routing-layer-complete (8),
            off (9),
            halt (10)
        }
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This value indicates the state of a router adjacency.
            On adjacencies over a circuit of type
            (phivCircuitCommonType) Ethernet, CI, or FDDI, with an
            adjacent node of type (phivAdjType) ROUTING IV or AREA,
            this variable is the state of the Ethernet
            Initialization Layer for this adjacency, and can have
            values INITIALIZING or UP. (See Section 9.1.1 of
            DECnet Phase IV Routing Layer Functional Specification.)

            On adjacencies over a circuit of type
            (phivCircuitCommonType) Ethernet, CI, or FDDI, with an
            adjacent node of type (phivAdjType) NONROUTING IV,
            this variable will always take on the value UP.

            On adjacencies over a circuit of type
            (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL,
            DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is
            the state of the Routing Layer Initialization Circuit
            State. (See section 7.3, ibid.)  It can have values
            between RUN and HALT.

            On adjacencies over a circuit of type
            (phivCircuitCommonType) OTHER, this variable may be


            used in a manner consistent with the Initialization
            Layer used on that circuit."
        ::= { phivAdjEntry 7 }

   phivAdjPriority OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "Priority assigned by the adjacent node for this
            circuit."
     ::= { phivAdjEntry 8 }

   phivAdjExecListenTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS obsolete
        DESCRIPTION
            "This read-only value determines the maximum number of
            seconds allowed to elapse before Routing receives some
            message (either a Hello message or a user message) from
            the adjacent node on the circuit. It was agreed during
            Routing initialization with the adjacent Routing layer."
        ::= { phivAdjEntry 9 }

   -- New Adjacency Table this replaces the phivAdjTable.

   phivAdjNodeTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivAdjNodeEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "The Adjacent Node Table."
        ::= { adjacency 2 }

   phivAdjNodeEntry OBJECT-TYPE
        SYNTAX PhivAdjNodeEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "There is one entry in the table for each adjacency."
        INDEX  { phivAdjNodeCircuitIndex, phivAdjAddr }
        ::= { phivAdjNodeTable 1 }

   PhivAdjNodeEntry ::=
        SEQUENCE {
            phivAdjNodeCircuitIndex
                INTEGER,


            phivAdjAddr
                PhivAddr,
            phivAdjNodeBlockSize
                INTEGER,
            phivAdjNodeListenTimer
                INTEGER,
            phivAdjNodeCircuitEtherServPhysAddr
                OCTET STRING,
            phivAdjNodeType
                INTEGER,
            phivAdjNodeState
                INTEGER,
            phivAdjNodePriority
                INTEGER
         }

   phivAdjNodeCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known circuit.  This
            value is the same as phivCircuitIndex and identifies the
            circuit over which the adjacency is realized."
        ::= { phivAdjNodeEntry 1 }

   phivAdjAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The address of the adjacent node."
        ::= { phivAdjNodeEntry 2 }

   phivAdjNodeBlockSize OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This read-only parameter is the block size that was
            negotiated with the adjacent Routing layer during Routing
            initialization over a particular circuit. It includes the
            routing header, but excludes the data link header. This
            parameter is qualified by ADJACENT NODE."
        ::= { phivAdjNodeEntry 3 }

   phivAdjNodeListenTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)


        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value determines the maximum number of seconds
            allowed to elapse before Routing receives some message
            (either a Hello message or a user message) from the
            adjacent node on the circuit. It was agreed during
            Routing initialization with the adjacent Routing layer.
            This parameter is qualified by ADJACENT NODE."
        ::= { phivAdjNodeEntry 4 }

   phivAdjNodeCircuitEtherServPhysAddr OBJECT-TYPE
        SYNTAX OCTET STRING (SIZE (6))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This parameter indicates the Ethernet physical address
            of an adjacent node that is being serviced on this
            circuit. This parameter is a qualifier for SERVICE
            SUBSTATE."
        ::= { phivAdjNodeEntry 5 }

   phivAdjNodeType OBJECT-TYPE
        SYNTAX INTEGER {
            routing-III (1),
            nonrouting-III (2),
            area (3),
            routing-IV (4),
            nonrouting-IV (5)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This parameter indicates the type of adjacency.

            For adjacent nodes, this is a read-only parameter that
            indicates the type of the reachable adjacent node.
            NOTE: The routing-III and nonrouting-III values are
            incremented by one compared to the standard DECnet
            values in order to maintain compliance with RFC 1155)"
        ::= { phivAdjNodeEntry 6 }

   phivAdjNodeState OBJECT-TYPE
        SYNTAX INTEGER {
            initializing (1),          -- Ethernet one-way
            up (2),                    -- Ethernet two-way
            run (3),                   -- The eight DDCMP/X.25 states
            circuit-rejected (4),


            data-link-start (5),
            routing-layer-initialize (6),
            routing-layer-verify (7),
            routing-layer-complete (8),
            off (9),
            halt (10)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value indicates the state of a router adjacency.
            On adjacencies over a circuit of type
            (phivCircuitCommonType) Ethernet, CI, or FDDI, with an
            adjacent node of type (phivAdjNodeType) ROUTING IV or AREA,
            this variable is the state of the Ethernet
            Initialization Layer for this adjacency, and can have
            values INITIALIZING or UP. (See Section 9.1.1 of
            DECnet Phase IV Routing Layer Functional Specification.)

            On adjacencies over a circuit of type
            (phivCircuitCommonType) Ethernet, CI, or FDDI, with an
            adjacent node of type (phivAdjNodeType) NONROUTING IV,
            this variable will always take on the value UP.

            On adjacencies over a circuit of type
            (phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL,
            DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is
            the state of the Routing Layer Initialization Circuit
            State. (See section 7.3, ibid.)  It can have values
            between RUN and HALT.

            On adjacencies over a circuit of type
            (phivCircuitCommonType) OTHER, this variable may be
            used in a manner consistent with the Initialization
            Layer used on that circuit."
        ::= { phivAdjNodeEntry 7 }

   phivAdjNodePriority OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Priority assigned by the adjacent node for this
            circuit."
           ::= { phivAdjNodeEntry 8 }


   -- Line Group

   -- The implementation of the Line Group is mandatory for all
   -- conformant implementations of this memo.

   phivLineTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivLineEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "The Line Table."
        ::= { line 1 }

   phivLineEntry OBJECT-TYPE
        SYNTAX PhivLineEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "There is one entry in the table for each line."
        INDEX  { phivLineIndex }
        ::= { phivLineTable 1 }

   PhivLineEntry ::=
        SEQUENCE {
            phivLineIndex
                InterfaceIndex,
            phivLineName
                DisplayString,
            phivLineState
                INTEGER,
            phivLineSubstate
                INTEGER,
            phivLineService
                INTEGER,
            phivLineDevice
                DisplayString,
            phivLineReceiveBuffs
                INTEGER,
            phivLineProtocol
                INTEGER,
            phivLineServiceTimer
                INTEGER,
            phivLineMaxBlock
                INTEGER
        }

   phivLineIndex OBJECT-TYPE
        SYNTAX InterfaceIndex


        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The line on which this entry's equivalence is effective.
            This is the same as the ifIndex."
        ::= { phivLineEntry 1 }

   phivLineName OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..16))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The name of the line on this row of the table."
        ::= { phivLineEntry 2 }

   phivLineState OBJECT-TYPE
        SYNTAX INTEGER {
            on (1),
            off (2),
            service (3),
            cleared (4)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents Network Management operational
            state.
            NOTE that these values are incremented by one compared to
            the standard DECnet values."
        ::= { phivLineEntry 3 }

   phivLineSubstate OBJECT-TYPE
        SYNTAX INTEGER {
            starting (1),
            reflecting (2),
            looping (3),
            loading (4),
            dumping (5),
            triggering (6),
            auto-service (7),
            auto-loading (8),
            auto-dumping (9),
            auto-triggering (10),
            synchronizing (11),
            failed (12),
            running (13)
        }
        ACCESS read-only


        STATUS mandatory
        DESCRIPTION
            "This value represents the line's read-only Network
            Management substate.
            NOTE that these values are incremented by one compared to
            the standard DECnet values."
        ::= { phivLineEntry 4 }

   phivLineService OBJECT-TYPE
        SYNTAX INTEGER {
            starting (1),
            reflecting (2),
            looping (3),
            other (4)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the line's read-only Network
            Management service.
            NOTE that these values are incremented by one compared to
            the standard DECnet values and OTHER is a new addition."
        ::= { phivLineEntry 5 }

   phivLineDevice OBJECT-TYPE
        SYNTAX DisplayString (SIZE (0..16))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the Physical Link device to be
            used on the line."
        ::= { phivLineEntry 6 }

   phivLineReceiveBuffs OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the number of receive buffers
            reserved for the line. It is a decimal number in
            the range 0-65535.  0 is supported for those vendors
            that do not reserve buffers on a per line basis and
            use a pool of buffers that can be used by any line."
        ::= { phivLineEntry 7 }

   phivLineProtocol OBJECT-TYPE
        SYNTAX INTEGER {
            ddcmp-point (1),


            ddcmp-control (2),
            ddcmp-tributary (3),
            reserved (4),
            ddcmp-dmc (5),
            olapb (6),
            ethernet (7),
            ci (8),
            qp2 (9),
            other (14),
            fddi (15)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the protocol used on the line
            device.  Note that these values are incremented by
            one compared to the standard DECnet values."
        ::= { phivLineEntry 8 }

   phivLineServiceTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the amount of time in
            milliseconds allowed to elapse before a Data Link
            receive request completes while doing service
            operations."
        ::= { phivLineEntry 9 }

   phivLineMaxBlock OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the Data Link maximum block
            size on the line."
        ::= { phivLineEntry 10 }

   -- Non Broadcast Line Group

   -- The implementation of the Non Broadcast Line Group is optional.
   -- A system can be said to implement this group if and only if
   -- all objects in this group are implemented.

   phivNonBroadcastTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivNonBroadcastEntry
        ACCESS not-accessible


        STATUS mandatory
        DESCRIPTION
            "The Non Broadcast Table."
        ::= { nonBroadcastLine 1 }

   phivNonBroadcastEntry OBJECT-TYPE
        SYNTAX PhivNonBroadcastEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "There is one entry in the table for each
            Non Broadcast line."
        INDEX  { phivNonBroadcastIndex }
        ::= { phivNonBroadcastTable 1 }

   PhivNonBroadcastEntry ::=
        SEQUENCE {
            phivNonBroadcastIndex
                InterfaceIndex,
            phivNonBroadcastController
                INTEGER,
            phivNonBroadcastDuplex
                INTEGER,
            phivNonBroadcastClock
                INTEGER,
            phivNonBroadcastRetransmitTimer
                INTEGER
        }

   phivNonBroadcastIndex OBJECT-TYPE
        SYNTAX InterfaceIndex
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The Non Broadcast line on which this entry's
            equivalence is effective.  This is the same value
            as the ifIndex."
        ::= { phivNonBroadcastEntry 1 }

   phivNonBroadcastController OBJECT-TYPE
        SYNTAX INTEGER {
            normal (1),
            loopback (2),
            other (3)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION


            "This value represents the Physical Link hardware
            controller mode for the line device. The values
            for controller-mode are:

            NORMAL  For normal controller operating mode.

            LOOPBACK For software controllable loopback of the
            controller. On those devices that can support this
            mode, it causes all transmitted messages to be looped
            back from within the controller itself. This is
            accomplished without any manual intervention other
            than the setting of this parameter value.

            OTHER indicates function is not supported
            Note that these values are incremented by one compared to
            the standard DECnet values."
        ::= { phivNonBroadcastEntry 2 }

   phivNonBroadcastDuplex OBJECT-TYPE
        SYNTAX INTEGER {
            full (1),
            half (2)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the Physical Link hardware
            duplex mode of the line device. The possible modes
            are:

            FULL   Full-duplex
            HALF   Half-duplex

            Note that these values are incremented by one compared to
            the standard DECnet values."
        ::= { phivNonBroadcastEntry 3 }

   phivNonBroadcastClock OBJECT-TYPE
        SYNTAX INTEGER {
            external (1),
            internal (2),
            other (3)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents the Physical Link hardware clock
            mode for the line device. The values for clock-mode are:


            INTERNAL For software controllable loopback use of
            the clock. On those devices that can support this
            mode, it causes the device to supply a clock signal
            such that a transmitted messages can be looped
            back from outside the device. This may require manual
            intervention other than the setting of this parameter
            value. For example, the operator may have to connect
            a loopback plug in place of the normal line.

            EXTERNAL For normal clock operating mode, where the
            clock signal is supplied externally to the controller.
            Note that these values are incremented by one compared to
            the standard DECnet values."
        ::= { phivNonBroadcastEntry 4 }

   phivNonBroadcastRetransmitTimer OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value represents number of milliseconds before
            the Data Link retransmits a block on the line. On
            half-duplex lines, this parameter is the select timer."
        DEFVAL { 3000 }
        ::= { phivNonBroadcastEntry 5 }

   -- Area Parameters Group

   -- The implementation of the Area Parameters Group is mandatory
   -- for all systems which implement level 2 routing.

   phivAreaTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivAreaEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Table of information kept on all areas known to
            this unit."
        ::= { area 1 }

   phivAreaEntry OBJECT-TYPE
        SYNTAX PhivAreaEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "The area routing information."
        INDEX  { phivAreaNum }


        ::= { phivAreaTable 1 }

   PhivAreaEntry ::=
        SEQUENCE {
            phivAreaNum
                INTEGER,
            phivAreaState
                INTEGER,
            phivAreaCost
                Gauge,
            phivAreaHops
                INTEGER,
            phivAreaNextNode
                PhivAddr,
            phivAreaCircuitIndex
               INTEGER
        }

   phivAreaNum OBJECT-TYPE
        SYNTAX INTEGER (0..64)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value indicates the area number of this entry."
        ::= { phivAreaEntry 1 }

   phivAreaState OBJECT-TYPE
        SYNTAX INTEGER {
            reachable (4),
            unreachable (5)
        }
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This value indicates the state of the area"
        ::= { phivAreaEntry 2 }

   phivAreaCost OBJECT-TYPE
        SYNTAX Gauge
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The total cost over the current path to the
             destination area. Cost is a value associated with
             using a circuit. Routing routes messages (data)
             along the path between 2 areas with the smallest
             cost."
        ::= { phivAreaEntry 3 }


   phivAreaHops OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The number of hops to a destination area. A hop is
            the routing value representing the logical distance
            between two areas in network."
        ::= { phivAreaEntry 4 }

   phivAreaNextNode OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The next node on the circuit used to get to the
            area under scrutiny."
        ::= { phivAreaEntry 5 }

   phivAreaCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known circuit."
        ::= { phivAreaEntry 6 }

   -- Additional Area Parameters

   phivAreaMaxCost OBJECT-TYPE
        SYNTAX INTEGER (1..1022)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum total path cost
            allowed from the executor to any other level 2 routing
            node. The AREA MAXIMUM COST number is decimal in the
            range 1-1022. This parameter is only applicable if
            the executor node is of type AREA."
        ::= { area 2 }

   phivAreaMaxHops OBJECT-TYPE
        SYNTAX INTEGER (1..30)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the maximum number of routing hops


            allowable from the executor to any other level 2
            routing node.  This parameter is only applicable if the
            executor node is of type AREA."
        ::= { area 3 }

   phivRouteMaxArea OBJECT-TYPE
        SYNTAX INTEGER (1..63)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the largest area number and,
            therefore, number of areas that can be known about
            by the executor node's Routing. This parameter is only
            applicable if the executor node is of type AREA."
        ::= { area 4 }

END