File: synoptics.mib

package info (click to toggle)
scotty 2.1.9-1
  • links: PTS
  • area: main
  • in suites: hamm
  • size: 9,984 kB
  • ctags: 4,313
  • sloc: ansic: 35,946; sh: 12,591; tcl: 8,122; yacc: 2,442; makefile: 898; lex: 370
file content (6156 lines) | stat: -rw-r--r-- 209,707 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
1658
1659
1660
1661
1662
1663
1664
1665
1666
1667
1668
1669
1670
1671
1672
1673
1674
1675
1676
1677
1678
1679
1680
1681
1682
1683
1684
1685
1686
1687
1688
1689
1690
1691
1692
1693
1694
1695
1696
1697
1698
1699
1700
1701
1702
1703
1704
1705
1706
1707
1708
1709
1710
1711
1712
1713
1714
1715
1716
1717
1718
1719
1720
1721
1722
1723
1724
1725
1726
1727
1728
1729
1730
1731
1732
1733
1734
1735
1736
1737
1738
1739
1740
1741
1742
1743
1744
1745
1746
1747
1748
1749
1750
1751
1752
1753
1754
1755
1756
1757
1758
1759
1760
1761
1762
1763
1764
1765
1766
1767
1768
1769
1770
1771
1772
1773
1774
1775
1776
1777
1778
1779
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
1796
1797
1798
1799
1800
1801
1802
1803
1804
1805
1806
1807
1808
1809
1810
1811
1812
1813
1814
1815
1816
1817
1818
1819
1820
1821
1822
1823
1824
1825
1826
1827
1828
1829
1830
1831
1832
1833
1834
1835
1836
1837
1838
1839
1840
1841
1842
1843
1844
1845
1846
1847
1848
1849
1850
1851
1852
1853
1854
1855
1856
1857
1858
1859
1860
1861
1862
1863
1864
1865
1866
1867
1868
1869
1870
1871
1872
1873
1874
1875
1876
1877
1878
1879
1880
1881
1882
1883
1884
1885
1886
1887
1888
1889
1890
1891
1892
1893
1894
1895
1896
1897
1898
1899
1900
1901
1902
1903
1904
1905
1906
1907
1908
1909
1910
1911
1912
1913
1914
1915
1916
1917
1918
1919
1920
1921
1922
1923
1924
1925
1926
1927
1928
1929
1930
1931
1932
1933
1934
1935
1936
1937
1938
1939
1940
1941
1942
1943
1944
1945
1946
1947
1948
1949
1950
1951
1952
1953
1954
1955
1956
1957
1958
1959
1960
1961
1962
1963
1964
1965
1966
1967
1968
1969
1970
1971
1972
1973
1974
1975
1976
1977
1978
1979
1980
1981
1982
1983
1984
1985
1986
1987
1988
1989
1990
1991
1992
1993
1994
1995
1996
1997
1998
1999
2000
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034
2035
2036
2037
2038
2039
2040
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
2051
2052
2053
2054
2055
2056
2057
2058
2059
2060
2061
2062
2063
2064
2065
2066
2067
2068
2069
2070
2071
2072
2073
2074
2075
2076
2077
2078
2079
2080
2081
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
2092
2093
2094
2095
2096
2097
2098
2099
2100
2101
2102
2103
2104
2105
2106
2107
2108
2109
2110
2111
2112
2113
2114
2115
2116
2117
2118
2119
2120
2121
2122
2123
2124
2125
2126
2127
2128
2129
2130
2131
2132
2133
2134
2135
2136
2137
2138
2139
2140
2141
2142
2143
2144
2145
2146
2147
2148
2149
2150
2151
2152
2153
2154
2155
2156
2157
2158
2159
2160
2161
2162
2163
2164
2165
2166
2167
2168
2169
2170
2171
2172
2173
2174
2175
2176
2177
2178
2179
2180
2181
2182
2183
2184
2185
2186
2187
2188
2189
2190
2191
2192
2193
2194
2195
2196
2197
2198
2199
2200
2201
2202
2203
2204
2205
2206
2207
2208
2209
2210
2211
2212
2213
2214
2215
2216
2217
2218
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234
2235
2236
2237
2238
2239
2240
2241
2242
2243
2244
2245
2246
2247
2248
2249
2250
2251
2252
2253
2254
2255
2256
2257
2258
2259
2260
2261
2262
2263
2264
2265
2266
2267
2268
2269
2270
2271
2272
2273
2274
2275
2276
2277
2278
2279
2280
2281
2282
2283
2284
2285
2286
2287
2288
2289
2290
2291
2292
2293
2294
2295
2296
2297
2298
2299
2300
2301
2302
2303
2304
2305
2306
2307
2308
2309
2310
2311
2312
2313
2314
2315
2316
2317
2318
2319
2320
2321
2322
2323
2324
2325
2326
2327
2328
2329
2330
2331
2332
2333
2334
2335
2336
2337
2338
2339
2340
2341
2342
2343
2344
2345
2346
2347
2348
2349
2350
2351
2352
2353
2354
2355
2356
2357
2358
2359
2360
2361
2362
2363
2364
2365
2366
2367
2368
2369
2370
2371
2372
2373
2374
2375
2376
2377
2378
2379
2380
2381
2382
2383
2384
2385
2386
2387
2388
2389
2390
2391
2392
2393
2394
2395
2396
2397
2398
2399
2400
2401
2402
2403
2404
2405
2406
2407
2408
2409
2410
2411
2412
2413
2414
2415
2416
2417
2418
2419
2420
2421
2422
2423
2424
2425
2426
2427
2428
2429
2430
2431
2432
2433
2434
2435
2436
2437
2438
2439
2440
2441
2442
2443
2444
2445
2446
2447
2448
2449
2450
2451
2452
2453
2454
2455
2456
2457
2458
2459
2460
2461
2462
2463
2464
2465
2466
2467
2468
2469
2470
2471
2472
2473
2474
2475
2476
2477
2478
2479
2480
2481
2482
2483
2484
2485
2486
2487
2488
2489
2490
2491
2492
2493
2494
2495
2496
2497
2498
2499
2500
2501
2502
2503
2504
2505
2506
2507
2508
2509
2510
2511
2512
2513
2514
2515
2516
2517
2518
2519
2520
2521
2522
2523
2524
2525
2526
2527
2528
2529
2530
2531
2532
2533
2534
2535
2536
2537
2538
2539
2540
2541
2542
2543
2544
2545
2546
2547
2548
2549
2550
2551
2552
2553
2554
2555
2556
2557
2558
2559
2560
2561
2562
2563
2564
2565
2566
2567
2568
2569
2570
2571
2572
2573
2574
2575
2576
2577
2578
2579
2580
2581
2582
2583
2584
2585
2586
2587
2588
2589
2590
2591
2592
2593
2594
2595
2596
2597
2598
2599
2600
2601
2602
2603
2604
2605
2606
2607
2608
2609
2610
2611
2612
2613
2614
2615
2616
2617
2618
2619
2620
2621
2622
2623
2624
2625
2626
2627
2628
2629
2630
2631
2632
2633
2634
2635
2636
2637
2638
2639
2640
2641
2642
2643
2644
2645
2646
2647
2648
2649
2650
2651
2652
2653
2654
2655
2656
2657
2658
2659
2660
2661
2662
2663
2664
2665
2666
2667
2668
2669
2670
2671
2672
2673
2674
2675
2676
2677
2678
2679
2680
2681
2682
2683
2684
2685
2686
2687
2688
2689
2690
2691
2692
2693
2694
2695
2696
2697
2698
2699
2700
2701
2702
2703
2704
2705
2706
2707
2708
2709
2710
2711
2712
2713
2714
2715
2716
2717
2718
2719
2720
2721
2722
2723
2724
2725
2726
2727
2728
2729
2730
2731
2732
2733
2734
2735
2736
2737
2738
2739
2740
2741
2742
2743
2744
2745
2746
2747
2748
2749
2750
2751
2752
2753
2754
2755
2756
2757
2758
2759
2760
2761
2762
2763
2764
2765
2766
2767
2768
2769
2770
2771
2772
2773
2774
2775
2776
2777
2778
2779
2780
2781
2782
2783
2784
2785
2786
2787
2788
2789
2790
2791
2792
2793
2794
2795
2796
2797
2798
2799
2800
2801
2802
2803
2804
2805
2806
2807
2808
2809
2810
2811
2812
2813
2814
2815
2816
2817
2818
2819
2820
2821
2822
2823
2824
2825
2826
2827
2828
2829
2830
2831
2832
2833
2834
2835
2836
2837
2838
2839
2840
2841
2842
2843
2844
2845
2846
2847
2848
2849
2850
2851
2852
2853
2854
2855
2856
2857
2858
2859
2860
2861
2862
2863
2864
2865
2866
2867
2868
2869
2870
2871
2872
2873
2874
2875
2876
2877
2878
2879
2880
2881
2882
2883
2884
2885
2886
2887
2888
2889
2890
2891
2892
2893
2894
2895
2896
2897
2898
2899
2900
2901
2902
2903
2904
2905
2906
2907
2908
2909
2910
2911
2912
2913
2914
2915
2916
2917
2918
2919
2920
2921
2922
2923
2924
2925
2926
2927
2928
2929
2930
2931
2932
2933
2934
2935
2936
2937
2938
2939
2940
2941
2942
2943
2944
2945
2946
2947
2948
2949
2950
2951
2952
2953
2954
2955
2956
2957
2958
2959
2960
2961
2962
2963
2964
2965
2966
2967
2968
2969
2970
2971
2972
2973
2974
2975
2976
2977
2978
2979
2980
2981
2982
2983
2984
2985
2986
2987
2988
2989
2990
2991
2992
2993
2994
2995
2996
2997
2998
2999
3000
3001
3002
3003
3004
3005
3006
3007
3008
3009
3010
3011
3012
3013
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
3031
3032
3033
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
3057
3058
3059
3060
3061
3062
3063
3064
3065
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
3081
3082
3083
3084
3085
3086
3087
3088
3089
3090
3091
3092
3093
3094
3095
3096
3097
3098
3099
3100
3101
3102
3103
3104
3105
3106
3107
3108
3109
3110
3111
3112
3113
3114
3115
3116
3117
3118
3119
3120
3121
3122
3123
3124
3125
3126
3127
3128
3129
3130
3131
3132
3133
3134
3135
3136
3137
3138
3139
3140
3141
3142
3143
3144
3145
3146
3147
3148
3149
3150
3151
3152
3153
3154
3155
3156
3157
3158
3159
3160
3161
3162
3163
3164
3165
3166
3167
3168
3169
3170
3171
3172
3173
3174
3175
3176
3177
3178
3179
3180
3181
3182
3183
3184
3185
3186
3187
3188
3189
3190
3191
3192
3193
3194
3195
3196
3197
3198
3199
3200
3201
3202
3203
3204
3205
3206
3207
3208
3209
3210
3211
3212
3213
3214
3215
3216
3217
3218
3219
3220
3221
3222
3223
3224
3225
3226
3227
3228
3229
3230
3231
3232
3233
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3244
3245
3246
3247
3248
3249
3250
3251
3252
3253
3254
3255
3256
3257
3258
3259
3260
3261
3262
3263
3264
3265
3266
3267
3268
3269
3270
3271
3272
3273
3274
3275
3276
3277
3278
3279
3280
3281
3282
3283
3284
3285
3286
3287
3288
3289
3290
3291
3292
3293
3294
3295
3296
3297
3298
3299
3300
3301
3302
3303
3304
3305
3306
3307
3308
3309
3310
3311
3312
3313
3314
3315
3316
3317
3318
3319
3320
3321
3322
3323
3324
3325
3326
3327
3328
3329
3330
3331
3332
3333
3334
3335
3336
3337
3338
3339
3340
3341
3342
3343
3344
3345
3346
3347
3348
3349
3350
3351
3352
3353
3354
3355
3356
3357
3358
3359
3360
3361
3362
3363
3364
3365
3366
3367
3368
3369
3370
3371
3372
3373
3374
3375
3376
3377
3378
3379
3380
3381
3382
3383
3384
3385
3386
3387
3388
3389
3390
3391
3392
3393
3394
3395
3396
3397
3398
3399
3400
3401
3402
3403
3404
3405
3406
3407
3408
3409
3410
3411
3412
3413
3414
3415
3416
3417
3418
3419
3420
3421
3422
3423
3424
3425
3426
3427
3428
3429
3430
3431
3432
3433
3434
3435
3436
3437
3438
3439
3440
3441
3442
3443
3444
3445
3446
3447
3448
3449
3450
3451
3452
3453
3454
3455
3456
3457
3458
3459
3460
3461
3462
3463
3464
3465
3466
3467
3468
3469
3470
3471
3472
3473
3474
3475
3476
3477
3478
3479
3480
3481
3482
3483
3484
3485
3486
3487
3488
3489
3490
3491
3492
3493
3494
3495
3496
3497
3498
3499
3500
3501
3502
3503
3504
3505
3506
3507
3508
3509
3510
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529
3530
3531
3532
3533
3534
3535
3536
3537
3538
3539
3540
3541
3542
3543
3544
3545
3546
3547
3548
3549
3550
3551
3552
3553
3554
3555
3556
3557
3558
3559
3560
3561
3562
3563
3564
3565
3566
3567
3568
3569
3570
3571
3572
3573
3574
3575
3576
3577
3578
3579
3580
3581
3582
3583
3584
3585
3586
3587
3588
3589
3590
3591
3592
3593
3594
3595
3596
3597
3598
3599
3600
3601
3602
3603
3604
3605
3606
3607
3608
3609
3610
3611
3612
3613
3614
3615
3616
3617
3618
3619
3620
3621
3622
3623
3624
3625
3626
3627
3628
3629
3630
3631
3632
3633
3634
3635
3636
3637
3638
3639
3640
3641
3642
3643
3644
3645
3646
3647
3648
3649
3650
3651
3652
3653
3654
3655
3656
3657
3658
3659
3660
3661
3662
3663
3664
3665
3666
3667
3668
3669
3670
3671
3672
3673
3674
3675
3676
3677
3678
3679
3680
3681
3682
3683
3684
3685
3686
3687
3688
3689
3690
3691
3692
3693
3694
3695
3696
3697
3698
3699
3700
3701
3702
3703
3704
3705
3706
3707
3708
3709
3710
3711
3712
3713
3714
3715
3716
3717
3718
3719
3720
3721
3722
3723
3724
3725
3726
3727
3728
3729
3730
3731
3732
3733
3734
3735
3736
3737
3738
3739
3740
3741
3742
3743
3744
3745
3746
3747
3748
3749
3750
3751
3752
3753
3754
3755
3756
3757
3758
3759
3760
3761
3762
3763
3764
3765
3766
3767
3768
3769
3770
3771
3772
3773
3774
3775
3776
3777
3778
3779
3780
3781
3782
3783
3784
3785
3786
3787
3788
3789
3790
3791
3792
3793
3794
3795
3796
3797
3798
3799
3800
3801
3802
3803
3804
3805
3806
3807
3808
3809
3810
3811
3812
3813
3814
3815
3816
3817
3818
3819
3820
3821
3822
3823
3824
3825
3826
3827
3828
3829
3830
3831
3832
3833
3834
3835
3836
3837
3838
3839
3840
3841
3842
3843
3844
3845
3846
3847
3848
3849
3850
3851
3852
3853
3854
3855
3856
3857
3858
3859
3860
3861
3862
3863
3864
3865
3866
3867
3868
3869
3870
3871
3872
3873
3874
3875
3876
3877
3878
3879
3880
3881
3882
3883
3884
3885
3886
3887
3888
3889
3890
3891
3892
3893
3894
3895
3896
3897
3898
3899
3900
3901
3902
3903
3904
3905
3906
3907
3908
3909
3910
3911
3912
3913
3914
3915
3916
3917
3918
3919
3920
3921
3922
3923
3924
3925
3926
3927
3928
3929
3930
3931
3932
3933
3934
3935
3936
3937
3938
3939
3940
3941
3942
3943
3944
3945
3946
3947
3948
3949
3950
3951
3952
3953
3954
3955
3956
3957
3958
3959
3960
3961
3962
3963
3964
3965
3966
3967
3968
3969
3970
3971
3972
3973
3974
3975
3976
3977
3978
3979
3980
3981
3982
3983
3984
3985
3986
3987
3988
3989
3990
3991
3992
3993
3994
3995
3996
3997
3998
3999
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
4010
4011
4012
4013
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
4028
4029
4030
4031
4032
4033
4034
4035
4036
4037
4038
4039
4040
4041
4042
4043
4044
4045
4046
4047
4048
4049
4050
4051
4052
4053
4054
4055
4056
4057
4058
4059
4060
4061
4062
4063
4064
4065
4066
4067
4068
4069
4070
4071
4072
4073
4074
4075
4076
4077
4078
4079
4080
4081
4082
4083
4084
4085
4086
4087
4088
4089
4090
4091
4092
4093
4094
4095
4096
4097
4098
4099
4100
4101
4102
4103
4104
4105
4106
4107
4108
4109
4110
4111
4112
4113
4114
4115
4116
4117
4118
4119
4120
4121
4122
4123
4124
4125
4126
4127
4128
4129
4130
4131
4132
4133
4134
4135
4136
4137
4138
4139
4140
4141
4142
4143
4144
4145
4146
4147
4148
4149
4150
4151
4152
4153
4154
4155
4156
4157
4158
4159
4160
4161
4162
4163
4164
4165
4166
4167
4168
4169
4170
4171
4172
4173
4174
4175
4176
4177
4178
4179
4180
4181
4182
4183
4184
4185
4186
4187
4188
4189
4190
4191
4192
4193
4194
4195
4196
4197
4198
4199
4200
4201
4202
4203
4204
4205
4206
4207
4208
4209
4210
4211
4212
4213
4214
4215
4216
4217
4218
4219
4220
4221
4222
4223
4224
4225
4226
4227
4228
4229
4230
4231
4232
4233
4234
4235
4236
4237
4238
4239
4240
4241
4242
4243
4244
4245
4246
4247
4248
4249
4250
4251
4252
4253
4254
4255
4256
4257
4258
4259
4260
4261
4262
4263
4264
4265
4266
4267
4268
4269
4270
4271
4272
4273
4274
4275
4276
4277
4278
4279
4280
4281
4282
4283
4284
4285
4286
4287
4288
4289
4290
4291
4292
4293
4294
4295
4296
4297
4298
4299
4300
4301
4302
4303
4304
4305
4306
4307
4308
4309
4310
4311
4312
4313
4314
4315
4316
4317
4318
4319
4320
4321
4322
4323
4324
4325
4326
4327
4328
4329
4330
4331
4332
4333
4334
4335
4336
4337
4338
4339
4340
4341
4342
4343
4344
4345
4346
4347
4348
4349
4350
4351
4352
4353
4354
4355
4356
4357
4358
4359
4360
4361
4362
4363
4364
4365
4366
4367
4368
4369
4370
4371
4372
4373
4374
4375
4376
4377
4378
4379
4380
4381
4382
4383
4384
4385
4386
4387
4388
4389
4390
4391
4392
4393
4394
4395
4396
4397
4398
4399
4400
4401
4402
4403
4404
4405
4406
4407
4408
4409
4410
4411
4412
4413
4414
4415
4416
4417
4418
4419
4420
4421
4422
4423
4424
4425
4426
4427
4428
4429
4430
4431
4432
4433
4434
4435
4436
4437
4438
4439
4440
4441
4442
4443
4444
4445
4446
4447
4448
4449
4450
4451
4452
4453
4454
4455
4456
4457
4458
4459
4460
4461
4462
4463
4464
4465
4466
4467
4468
4469
4470
4471
4472
4473
4474
4475
4476
4477
4478
4479
4480
4481
4482
4483
4484
4485
4486
4487
4488
4489
4490
4491
4492
4493
4494
4495
4496
4497
4498
4499
4500
4501
4502
4503
4504
4505
4506
4507
4508
4509
4510
4511
4512
4513
4514
4515
4516
4517
4518
4519
4520
4521
4522
4523
4524
4525
4526
4527
4528
4529
4530
4531
4532
4533
4534
4535
4536
4537
4538
4539
4540
4541
4542
4543
4544
4545
4546
4547
4548
4549
4550
4551
4552
4553
4554
4555
4556
4557
4558
4559
4560
4561
4562
4563
4564
4565
4566
4567
4568
4569
4570
4571
4572
4573
4574
4575
4576
4577
4578
4579
4580
4581
4582
4583
4584
4585
4586
4587
4588
4589
4590
4591
4592
4593
4594
4595
4596
4597
4598
4599
4600
4601
4602
4603
4604
4605
4606
4607
4608
4609
4610
4611
4612
4613
4614
4615
4616
4617
4618
4619
4620
4621
4622
4623
4624
4625
4626
4627
4628
4629
4630
4631
4632
4633
4634
4635
4636
4637
4638
4639
4640
4641
4642
4643
4644
4645
4646
4647
4648
4649
4650
4651
4652
4653
4654
4655
4656
4657
4658
4659
4660
4661
4662
4663
4664
4665
4666
4667
4668
4669
4670
4671
4672
4673
4674
4675
4676
4677
4678
4679
4680
4681
4682
4683
4684
4685
4686
4687
4688
4689
4690
4691
4692
4693
4694
4695
4696
4697
4698
4699
4700
4701
4702
4703
4704
4705
4706
4707
4708
4709
4710
4711
4712
4713
4714
4715
4716
4717
4718
4719
4720
4721
4722
4723
4724
4725
4726
4727
4728
4729
4730
4731
4732
4733
4734
4735
4736
4737
4738
4739
4740
4741
4742
4743
4744
4745
4746
4747
4748
4749
4750
4751
4752
4753
4754
4755
4756
4757
4758
4759
4760
4761
4762
4763
4764
4765
4766
4767
4768
4769
4770
4771
4772
4773
4774
4775
4776
4777
4778
4779
4780
4781
4782
4783
4784
4785
4786
4787
4788
4789
4790
4791
4792
4793
4794
4795
4796
4797
4798
4799
4800
4801
4802
4803
4804
4805
4806
4807
4808
4809
4810
4811
4812
4813
4814
4815
4816
4817
4818
4819
4820
4821
4822
4823
4824
4825
4826
4827
4828
4829
4830
4831
4832
4833
4834
4835
4836
4837
4838
4839
4840
4841
4842
4843
4844
4845
4846
4847
4848
4849
4850
4851
4852
4853
4854
4855
4856
4857
4858
4859
4860
4861
4862
4863
4864
4865
4866
4867
4868
4869
4870
4871
4872
4873
4874
4875
4876
4877
4878
4879
4880
4881
4882
4883
4884
4885
4886
4887
4888
4889
4890
4891
4892
4893
4894
4895
4896
4897
4898
4899
4900
4901
4902
4903
4904
4905
4906
4907
4908
4909
4910
4911
4912
4913
4914
4915
4916
4917
4918
4919
4920
4921
4922
4923
4924
4925
4926
4927
4928
4929
4930
4931
4932
4933
4934
4935
4936
4937
4938
4939
4940
4941
4942
4943
4944
4945
4946
4947
4948
4949
4950
4951
4952
4953
4954
4955
4956
4957
4958
4959
4960
4961
4962
4963
4964
4965
4966
4967
4968
4969
4970
4971
4972
4973
4974
4975
4976
4977
4978
4979
4980
4981
4982
4983
4984
4985
4986
4987
4988
4989
4990
4991
4992
4993
4994
4995
4996
4997
4998
4999
5000
5001
5002
5003
5004
5005
5006
5007
5008
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
5020
5021
5022
5023
5024
5025
5026
5027
5028
5029
5030
5031
5032
5033
5034
5035
5036
5037
5038
5039
5040
5041
5042
5043
5044
5045
5046
5047
5048
5049
5050
5051
5052
5053
5054
5055
5056
5057
5058
5059
5060
5061
5062
5063
5064
5065
5066
5067
5068
5069
5070
5071
5072
5073
5074
5075
5076
5077
5078
5079
5080
5081
5082
5083
5084
5085
5086
5087
5088
5089
5090
5091
5092
5093
5094
5095
5096
5097
5098
5099
5100
5101
5102
5103
5104
5105
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
5116
5117
5118
5119
5120
5121
5122
5123
5124
5125
5126
5127
5128
5129
5130
5131
5132
5133
5134
5135
5136
5137
5138
5139
5140
5141
5142
5143
5144
5145
5146
5147
5148
5149
5150
5151
5152
5153
5154
5155
5156
5157
5158
5159
5160
5161
5162
5163
5164
5165
5166
5167
5168
5169
5170
5171
5172
5173
5174
5175
5176
5177
5178
5179
5180
5181
5182
5183
5184
5185
5186
5187
5188
5189
5190
5191
5192
5193
5194
5195
5196
5197
5198
5199
5200
5201
5202
5203
5204
5205
5206
5207
5208
5209
5210
5211
5212
5213
5214
5215
5216
5217
5218
5219
5220
5221
5222
5223
5224
5225
5226
5227
5228
5229
5230
5231
5232
5233
5234
5235
5236
5237
5238
5239
5240
5241
5242
5243
5244
5245
5246
5247
5248
5249
5250
5251
5252
5253
5254
5255
5256
5257
5258
5259
5260
5261
5262
5263
5264
5265
5266
5267
5268
5269
5270
5271
5272
5273
5274
5275
5276
5277
5278
5279
5280
5281
5282
5283
5284
5285
5286
5287
5288
5289
5290
5291
5292
5293
5294
5295
5296
5297
5298
5299
5300
5301
5302
5303
5304
5305
5306
5307
5308
5309
5310
5311
5312
5313
5314
5315
5316
5317
5318
5319
5320
5321
5322
5323
5324
5325
5326
5327
5328
5329
5330
5331
5332
5333
5334
5335
5336
5337
5338
5339
5340
5341
5342
5343
5344
5345
5346
5347
5348
5349
5350
5351
5352
5353
5354
5355
5356
5357
5358
5359
5360
5361
5362
5363
5364
5365
5366
5367
5368
5369
5370
5371
5372
5373
5374
5375
5376
5377
5378
5379
5380
5381
5382
5383
5384
5385
5386
5387
5388
5389
5390
5391
5392
5393
5394
5395
5396
5397
5398
5399
5400
5401
5402
5403
5404
5405
5406
5407
5408
5409
5410
5411
5412
5413
5414
5415
5416
5417
5418
5419
5420
5421
5422
5423
5424
5425
5426
5427
5428
5429
5430
5431
5432
5433
5434
5435
5436
5437
5438
5439
5440
5441
5442
5443
5444
5445
5446
5447
5448
5449
5450
5451
5452
5453
5454
5455
5456
5457
5458
5459
5460
5461
5462
5463
5464
5465
5466
5467
5468
5469
5470
5471
5472
5473
5474
5475
5476
5477
5478
5479
5480
5481
5482
5483
5484
5485
5486
5487
5488
5489
5490
5491
5492
5493
5494
5495
5496
5497
5498
5499
5500
5501
5502
5503
5504
5505
5506
5507
5508
5509
5510
5511
5512
5513
5514
5515
5516
5517
5518
5519
5520
5521
5522
5523
5524
5525
5526
5527
5528
5529
5530
5531
5532
5533
5534
5535
5536
5537
5538
5539
5540
5541
5542
5543
5544
5545
5546
5547
5548
5549
5550
5551
5552
5553
5554
5555
5556
5557
5558
5559
5560
5561
5562
5563
5564
5565
5566
5567
5568
5569
5570
5571
5572
5573
5574
5575
5576
5577
5578
5579
5580
5581
5582
5583
5584
5585
5586
5587
5588
5589
5590
5591
5592
5593
5594
5595
5596
5597
5598
5599
5600
5601
5602
5603
5604
5605
5606
5607
5608
5609
5610
5611
5612
5613
5614
5615
5616
5617
5618
5619
5620
5621
5622
5623
5624
5625
5626
5627
5628
5629
5630
5631
5632
5633
5634
5635
5636
5637
5638
5639
5640
5641
5642
5643
5644
5645
5646
5647
5648
5649
5650
5651
5652
5653
5654
5655
5656
5657
5658
5659
5660
5661
5662
5663
5664
5665
5666
5667
5668
5669
5670
5671
5672
5673
5674
5675
5676
5677
5678
5679
5680
5681
5682
5683
5684
5685
5686
5687
5688
5689
5690
5691
5692
5693
5694
5695
5696
5697
5698
5699
5700
5701
5702
5703
5704
5705
5706
5707
5708
5709
5710
5711
5712
5713
5714
5715
5716
5717
5718
5719
5720
5721
5722
5723
5724
5725
5726
5727
5728
5729
5730
5731
5732
5733
5734
5735
5736
5737
5738
5739
5740
5741
5742
5743
5744
5745
5746
5747
5748
5749
5750
5751
5752
5753
5754
5755
5756
5757
5758
5759
5760
5761
5762
5763
5764
5765
5766
5767
5768
5769
5770
5771
5772
5773
5774
5775
5776
5777
5778
5779
5780
5781
5782
5783
5784
5785
5786
5787
5788
5789
5790
5791
5792
5793
5794
5795
5796
5797
5798
5799
5800
5801
5802
5803
5804
5805
5806
5807
5808
5809
5810
5811
5812
5813
5814
5815
5816
5817
5818
5819
5820
5821
5822
5823
5824
5825
5826
5827
5828
5829
5830
5831
5832
5833
5834
5835
5836
5837
5838
5839
5840
5841
5842
5843
5844
5845
5846
5847
5848
5849
5850
5851
5852
5853
5854
5855
5856
5857
5858
5859
5860
5861
5862
5863
5864
5865
5866
5867
5868
5869
5870
5871
5872
5873
5874
5875
5876
5877
5878
5879
5880
5881
5882
5883
5884
5885
5886
5887
5888
5889
5890
5891
5892
5893
5894
5895
5896
5897
5898
5899
5900
5901
5902
5903
5904
5905
5906
5907
5908
5909
5910
5911
5912
5913
5914
5915
5916
5917
5918
5919
5920
5921
5922
5923
5924
5925
5926
5927
5928
5929
5930
5931
5932
5933
5934
5935
5936
5937
5938
5939
5940
5941
5942
5943
5944
5945
5946
5947
5948
5949
5950
5951
5952
5953
5954
5955
5956
5957
5958
5959
5960
5961
5962
5963
5964
5965
5966
5967
5968
5969
5970
5971
5972
5973
5974
5975
5976
5977
5978
5979
5980
5981
5982
5983
5984
5985
5986
5987
5988
5989
5990
5991
5992
5993
5994
5995
5996
5997
5998
5999
6000
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
-- SynOptics Basic Ethernet & Token Ring 2K & 3K MIB
-- Revision 09/18/94.

-- Copyright 1991-94 SynOptics Communications, Inc.
-- All rights reserved.
-- This SynOptics SNMP Management Information Base Specification
-- (Specification) embodies SynOptics' confidential and
-- proprietary intellectual property. SynOptics retains all
-- title and ownership in the Specification, including any
-- revisions.

-- This Specification is supplied "AS IS," and SynOptics makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
--
-- This MIB is based on the 331x/331xA v5.2, 351x/271x v3.5,
-- and 281x v5.1.1 basic agents, and was constructed from the
-- Common MIB v4.6.1, Token Ring MIB v4.2.2, Ethernet MIB v4.5.1,
-- Synoptic's IEEE802.3 MIB v1.1.0, and IPX MIB v1.1.0.  The
-- objects contained in the MIB are generally a subset of
-- the advanced agents.

SYNOPTICS-BASIC-ETHTOK-MIB DEFINITIONS ::= BEGIN

IMPORTS
        enterprises,
        IpAddress, Counter, Gauge, TimeTicks
                FROM RFC1155-SMI
        OBJECT-TYPE
                FROM RFC-1212
        TRAP-TYPE
                FROM RFC-1215;

DisplayString ::=
            OCTET STRING

PhysAddress ::=
            OCTET STRING

SnpxBackplaneType ::=
            INTEGER {
            other(1),
            eth(2),
            ethTok(3),
            ethFddi(4),
            ethTokFddi(5),
            ethTokRed(6),
            ethTokFddiRed(7),
            tok(8)
            }

SnpxChassisType ::=
            INTEGER {
            other(1),
            m3000(2),
            m3030(3),
            m2310(4),
            m2810(5),
            m2912(6),
            m2914(7),
            m271x(8),
            m2813(9),
            m2814(10),
            m2915(11),
            m5000(12),
            m2813SA(13),
            m2814SA(14),
            m810M(15),
            m1032x(16),
            m5005(17),
            mAlcatelEthConc(18),
            m2715SA(20),
            m2486(21)
            }

S3ModuleType ::=
            INTEGER {
            empty(1),
            other(2),
            m3302(3),
            m3304-ST(4),
            m3305(5),
            m3308(6),
            m3313(7),
            m3313M(8),
            m3314-ST(9),
            m3314M-ST(10),
            m3323(11),
            m3324-ST(12),
            m3502(13),
            m3532(14),
            m3552(15),
            m3301(16),
            m3307(17),
            m3356(18),
            m3512(19),
            m3514(20),
            m3505(21),
            m3554(22),
            m3534(23),
            m3383(24),
            m3384(25),
            m331x(26),
            m351x(27),
            m3502-A(28),
            m3902(29),
            m3904(30),
            m3910S(31),
            m3386(32),
            m3394(33),
            m3395(34),
            m3323S(35),
            m3324S-ST(36),
            m3307A(37),
            m3308A(38),
            m3505A(39),
            m3513(40),
            m3333(41),
            m3334-ST(42),
            m3040(43),
            m3100R(44),
            notUsed45(45),
            notUsed46(46),
            m2810-hm(47),
            m2810-nmm(48),
            m3313S(49),
            m3314S(50),
            m3368(51),
            m3512S(52),
            m3513S(53),
            m3514S(54),
            m3522(55),
            m2912(56),
            m2914(57),
            notUsed58(58),
            m3301-75(59),
            m3301-93(60),
            m271x-nmm(61),
            m2705-hm(62),
            m2715-hm(63),
            m2813-nmm(64),
            m2814-nmm(65),
            m2813-hm(66),
            m2814-hm(67),
            m2803-hm(68),
            m2804-hm(69),
            m3395A(70),
            m3040S(71),
            m3502B(72),
            m3505B(73),
            m2715-F-hm(74),
            m2712-hm(75),
            m2712-F-hm(76),
            m2702-hm(77),
            m2702-C-hm(78),
            m2705-F-hm(79),
            m2702-F-hm(80),
            m2705-C-hm(81),
            m3902A(82),
            m2912A(83),
            m3313A(84),
            m3314A(85),
            m3307HD(86),
            m3328(87),
            m3904-2SM(88),
            m3910S-SM(89),
            m3800(90),
            m3910S-SD(91),
            m3904-4SM(92),
            m2915(93),
            m3910SA(94),
            m3910SA-SM(95),
            m3905(96),
            m2715B-hm(97),
            m2705B-hm(98),
            m2715B-F-hm(99),
            m2712B-hm(100),
            m2712B-F-hm(101),
            m2702B-C-hm(102),
            m3304A(103),
            m3486(104),
            m3308B(105),
            m2813SA-nmm(106),
            m2814SA-nmm(107),
            m3517SA(108),
            m810M(109),
            m3313SA(110),
            m3314SA(111),
            m3522A(112),
            m3504-ST(113),
            m3513SA(114),
            mAlcatel-Eth-nmm(115),
            mAlcatel-Eth-hm1(116),
            mAlcatel-Eth-hm(117),
            m2486-nmm(118),
            m2486-hm(119),
            m3174(120),
            m271xSA-nmm(121),
            m3299C(122),
            m3299U(123),
            m3299F(124)
            }

S3PsType ::=
            INTEGER {
            other(1),
            low(2),
            medium(3),
            high(4),
            redundantCapable(5),
            empty(6)
            }

IpxAddress ::=
            OCTET STRING (SIZE(10))

synoptics               OBJECT IDENTIFIER ::= { enterprises 45 }

products                OBJECT IDENTIFIER ::= { synoptics 1 }

s3SnmpAgent             OBJECT IDENTIFIER ::= { products 2 }

s3AgentSw               OBJECT IDENTIFIER ::= { s3SnmpAgent 1 }

s3AgentNetProtocol      OBJECT IDENTIFIER ::= { s3SnmpAgent 2 }

s3AgentIpProtocol       OBJECT IDENTIFIER ::= { s3AgentNetProtocol 1 }

s3AgentIpxProtocol      OBJECT IDENTIFIER ::= { s3AgentNetProtocol 2 }

s3AgentHw               OBJECT IDENTIFIER ::= { s3SnmpAgent 4 }

s3AgentLocImage         OBJECT IDENTIFIER ::= { s3SnmpAgent 6 }

series3000              OBJECT IDENTIFIER ::= { products 3 }

s3000Chassis            OBJECT IDENTIFIER ::= { series3000 1 }

s3000RedundantPs        OBJECT IDENTIFIER ::= { s3000Chassis 10 }

s3000Ethernet           OBJECT IDENTIFIER ::= { series3000 2 }

s3000EnetConcentrator   OBJECT IDENTIFIER ::= { s3000Ethernet 1 }

s3000EnetBoard          OBJECT IDENTIFIER ::= { s3000Ethernet 2 }

s3000EnetLocBridge      OBJECT IDENTIFIER ::= { s3000EnetBoard 2 }

s3000EnetRemBridge      OBJECT IDENTIFIER ::= { s3000EnetBoard 3 }

s3000EnetRouter         OBJECT IDENTIFIER ::= { s3000EnetBoard 4 }

s3000EnetPort           OBJECT IDENTIFIER ::= { s3000Ethernet 3 }

s3000EnetPlusStatistics OBJECT IDENTIFIER ::= { s3000Ethernet 10 }

s3000EnetPlusConc       OBJECT IDENTIFIER ::= { s3000EnetPlusStatistics 3 }

s3000TokenRing          OBJECT IDENTIFIER ::= { series3000 3 }

s3000TrBoard            OBJECT IDENTIFIER ::= { s3000TokenRing 2 }

s3000TrPort             OBJECT IDENTIFIER ::= { s3000TokenRing 3 }

s3000TrNmm              OBJECT IDENTIFIER ::= { s3000TokenRing 4 }

s3000TrNode             OBJECT IDENTIFIER ::= { s3000TokenRing 5 }

s3000TrRing             OBJECT IDENTIFIER ::= { s3000TokenRing 7 }

s3TrRingStats           OBJECT IDENTIFIER ::= { s3000TrRing 1 }

temporary               OBJECT IDENTIFIER ::= { synoptics 2 }

ieee8023                OBJECT IDENTIFIER ::= { temporary 1 }

registration            OBJECT IDENTIFIER ::= { synoptics 3 }

s3reg-3000              OBJECT IDENTIFIER ::= { registration 2 }

s3reg-3000-enetNMM      OBJECT IDENTIFIER ::= { s3reg-3000 1 }

s3reg-3000-trNMM        OBJECT IDENTIFIER ::= { s3reg-3000 2 }

s3reg-3030              OBJECT IDENTIFIER ::= { registration 3 }

s3reg-3030-enetNMM      OBJECT IDENTIFIER ::= { s3reg-3030 1 }

s3reg-3030-trNMM        OBJECT IDENTIFIER ::= { s3reg-3030 2 }

s3reg-2715              OBJECT IDENTIFIER ::= { registration 9 }

s3reg-2715-trNMM        OBJECT IDENTIFIER ::= { s3reg-2715 1 }

s3reg-281X              OBJECT IDENTIFIER ::= { registration 12 }

s3reg-281X-enetNMM      OBJECT IDENTIFIER ::= { s3reg-281X 1 }

s3AgentType OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            m3313(2),
            m3313M(3),
            m3314-ST(4),
            m3314M-ST(5),
            m2310(6),
            m3512(7),
            m3514(8),
            m332x(9),
            m3356(10),
            m332xS(11),
            m3910S(12),
            m3395(13),
            m3394(14),
            m3513(15),
            m331xS(16),
            m291x(17),
            m271x(18),
            m281x(19),
            m331xA(20),
            m3522(21),
            m2722(22),
            m281xSA(23),
            m810M(24),
            m351xSA(25),
            m331xSA(26),
            m271xSA(27),
            m2486(28)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The 3000 series agent's Module type."
    ::= { s3AgentSw 1 }

s3AgentFwVer OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent's module firmware version
                0=Rev A,1=Rev B,etc."
    ::= { s3AgentSw 2 }

s3AgentSwMajorVer OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent major software version number.
                (version is specified as major.minor.maint or 3.0.1).
                Object is in decimal."
    ::= { s3AgentSw 3 }

s3AgentSwMinorVer OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent minor software version number
                (version is specified as major.minor.maint or 3.0.1).
                Object is in decimal."
    ::= { s3AgentSw 4 }

s3AgentBootProtocol OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            bootp-tftp(2),
            tftp-only(3),
            ieee802-1e(4),
            proprietary(5),
            dll-download(6)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Boot protocol used to load the module with its software.
                On Agents with the Local Load option the value return by
                this object is valid only if the MIB object
                s3LocImageLoadMode is remoteBoot(2) or localAsBackup(4)."
    ::= { s3AgentSw 5 }

s3AgentBootFile OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..64))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The name of the boot file that is sent to the file
                server during boot time.  The actual boot protocol
                used to retrieve the file is determined by 
                s3AgentBootProtocol.

                This parameter will not take effect until written 
                into EEPROM (s3AgentWriteEeprom) and a reset
                (s3AgentReset) is issued. This parameter is used
                only if the s3AgentBootMode is set to use EEPROM."
    ::= { s3AgentSw 6 }

s3AgentAuthTrap OBJECT-TYPE
    SYNTAX  INTEGER {
            disable(1),
            enable(2)
            }
    ACCESS  read-write
    STATUS  deprecated
    DESCRIPTION
                "Enable or disable the use of authentication error
                trap generation.

                This parameter will take effect only after a restart
                (s3AgentRestart) is issued.  This parameter will not
                survive a reset (s3AgentReset) unless the specific
                NMM configuration file is updated to reflect the
                change.

                This object is now deprecated.  Managers should use
                the snmpEnableAuthenTraps object in MIB-II instead.
                This object is aliased to snmpEnableAuthenTraps.
                Changing either variable will change the other
                accordingly."
    ::= { s3AgentSw 7 }

s3AgentLocation OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..64))
    ACCESS  read-write
    STATUS  deprecated
    DESCRIPTION
                "This is a informational string that could be used
                to show the physical location (i.e. area) of the
                NMM or concentrator.

                This parameter will take effect only after a restart
                (s3AgentRestart) is issued.  This parameter will not
                survive a reset (s3AgentReset) unless the specific
                NMM configuration file is updated to reflect the
                change.

                This object is now deprecated.  Managers should use
                the sysLocation object in MIB-II instead."
    ::= { s3AgentSw 8 }

s3AgentMibLevel OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Used to determine current MIB release supported
                by agent.  The encoding of this object is of the
                following form: xyy, where x is the major version
                number and yy is the minor version number.  Thus,
                version 3.0 would be represented as 300,  version
                3.01 would be 301 and 3.1 would be 310.  Object is
                in decimal.  Values that correspond to each agent
                type and version are specified in the other
                SynOptics documentation."
    ::= { s3AgentSw 9 }

s3AgentFeatureLevel OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  deprecated
    DESCRIPTION
                "Used to determine feature level of the agent.
                The encoding of this object is of the following
                form: xyy, where x is the major version 
                number and yy is the minor version number.  Thus,
                feature level version 1.0 would be represented as
                100, version 1.01 would be 101 and 1.1 would be 110.
                Object is in decimal. The current values are the
                following:
                  100 - 331x V3.x
                        - Basic Agent
                  100 - 351x
                        - Basic Agent
                  100 - 271x V3.x
                        - Basic Agent
                  101 - 281x V5.0 
                        - Basic Agent
                        - Dual Stack
                  102 - 331x V4.2.0
                        - Basic Agent
                        - Non Segmentable Chassis
                        - Ethernet Common board table
                        - Ethernet Command port table
                        - redundant power supply group
                  103 - 331xA V4.2.0
                        - Basic Agent
                        - Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply group
                        - Ethernet plus statistics,
                  104 - 331xA V4.2.0
                        - Basic Agent
                        - Non-Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply group
                        - Ethernet plus statistics,
                  109 - 331x V4.2.0
                        - Basic Agent
                        - Segmentable Chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply group
                  112 - 281x V5.1.0
                        - Basic Agent
                        - Dual Stack
                        - Network to MAC address mapping
                  113 - 331x V5.1.0
                        - Basic Agent
                        - Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                  114 - 331x V5.1.0
                        - Basic Agent
                        - Non-Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                  115 - 331xA V5.1.0
                        - Basic Agent
                        - Segmentable chassis
                        - Dual Stack
                        - Full Truffle Support
                        - Network to MAC address mapping
                  116 - 331xA V5.1.0
                        - Basic Agent
                        - Non-Segmentable chassis
                        - Dual Stack
                        - Full Truffle Support
                        - Network to MAC address mapping
                  200 - 331x V4.0 & V4.0.1
                        - Advanced Agent
                  200 - 271x V4.x
                        - Advanced Agent
                  200 - 351x V4.x
                        - Advanced Agent
                  200 - all FDDI Agents
                  201 - 331x V4.1.0, V4.1.1
                        - Advanced Agent
                        - redundant power supply group
                  202 - 331xS V4.1.0, V4.1.1
                        - Advanced Agent
                        - redundant power supply  group
                        - DS/SD traffic tables,
                        - Ethernet plus statistics,
                        - frame type distribution table
                        - frame length distribution table
                  203 - 281x V4.2.0
                        - Advanced Agent
                        - Dual Stack
                  204 - 331x V4.2.0
                        - Advanced Agent
                        - Non-Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply group
                  205 - 331xS V4.2.0
                        - Advanced Agent
                        - Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply  group
                        - DS/SD traffic tables,
                        - Ethernet plus statistics,
                        - frame type distribution table
                        - frame length distribution table
                  206 - 331xS V4.2.0
                        - Advanced Agent
                        - Non-Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply  group
                        - DS/SD traffic tables,
                        - Ethernet plus statistics,
                        - frame type distribution table
                        - frame length distribution table
                  207 - 331xA V4.2.0
                        - Advanced agent
                        - Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply  group
                        - Ethernet plus statistics,
                  208 - 331xA V4.2.0
                        - Advanced agent
                        - Non-Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Common port table
                        - redundant power supply  group
                        - Ethernet plus statistics,
                  209 - 331x V4.2.0
                        - Advanced agent
                        - Segmentable chassis
                        - Ethernet Common board table
                        - Ethernet Command port table
                        - redundant power supply group
                  212 - 331x V5.1.0
                        - Advanced Agent
                        - Dual Stack
                        - Network to MAC address mapping
                        - RMON Ether Stats, History, Alarm, Event Groups
                  213 - 281x V5.1.0
                        - Advanced Agent
                        - Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                        - RMON Ether Stats, History, Alarm, Event Groups
                  214 - 331x V5.1.0
                        - Advanced Agent
                        - Non-Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                        - RMON Ether Stats, History, Alarm, Event Groups
                  215 - 331xA V5.1.0
                        - Advanced Agent
                        - Segmentable chassis
                        - RMON Ether Stats, History, Alarm, Event Groups
                        - Dual Stack
                        - Full Truffle Support
                        - Network to MAC address mapping
                  216 - 331xA V5.1.0
                        - Advanced Agent
                        - Non-Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                        - RMON Ether Stats, History, Alarm, Event Groups
                  217 - 331xS V5.1.0
                        - Advanced Agent
                        - Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                        - RMON Ether Stats, History, Alarm, Event Groups
                        - Bulk table retrieval for traffic matrix
                  218 - 331xS V5.1.0
                        - Advanced Agent
                        - Non-Segmentable chassis
                        - Full Truffle Support
                        - Dual Stack
                        - Network to MAC address mapping
                        - RMON Ether Stats, History, Alarm, Event Groups
                        - Bulk table retrieval for traffic matrix"
    ::= { s3AgentSw 10 }

s3AgentMySlotId OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Slot where this agent currently resides.  If
                hardware is unable to determine then a 0 should
                be returned."
    ::= { s3AgentSw 11 }

s3AgentUnAuthIp OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object contains the IP address of the last
                station that tried to access this agent with an
                invalid community string.  This object is used
                as a VarBind in an Authentication Trap PDU.  A get
                request will return the last value used, and will
                return the null address 0.0.0.0 if no 
                authentication traps have been sent."
    ::= { s3AgentSw 12 }

s3AgentUnAuthComm OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..20))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object contains the community string of the
                last unauthenticated attempt to access this agent.
                This object is used as a VarBind in an Authentication
                Trap PDU.  A get request will return the last value
                used, and will return the null string (length 0) if
                no authentication traps have been sent."
    ::= { s3AgentSw 13 }

s3AgentSwLicenseCode OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(8))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The software license code assigned to this agent.
                This code is required for initializing the agent.
                The code consists of exactly eight printable
                characters."
    ::= { s3AgentSw 14 }

s3AgentPerformance OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This counts the CPU idle time of the agent
                in units of 10 microseconds."
    ::= { s3AgentSw 15 }

s3AgentSwMaintVer OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent software maintenance version number
                (version is specified as major.minor.maint or 3.0.1).
                Object is in decimal."
    ::= { s3AgentSw 16 }

s3AgentConfigLoadMode OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            remoteConfig(2),
            localConfig(3),
            localAsBackup(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the agent should get
                configuration data from the network, use the local
                configuration data, or try the network first and then
                fall back to local configuration if the network load
                fails.  This object applies only to agents with boot
                prom support for agent configuration load options.

                This parameter will not take effect until written into
                EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset)
                is issued.

                ***ACCESS VARIATION - changed access from read-write"
    ::= { s3AgentSw 17 }

s3AgentConfigActualSource OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            remoteConfig(2),
            localConfig(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the agent loaded configuration
                data from the network or used the local configuration
                data."
    ::= { s3AgentSw 18 }

s3AgentMgmtProtoMode OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ip(2),
            ipx(3),
            ipAndIpx(4)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This indicates from which network transports over
                which the agent will accept SNMP requests.  This object
                only applies to agents with IP and IPX dual stack support.

                This parameter will not take effect until written into
                EEPROM (s3AgentWriteEeprom) and a reset (s3AgentReset)
                or a restart (s3AgentRestart) is issued."
    ::= { s3AgentSw 19 }

s3AgentActualMgmtProtocol OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ip(2),
            ipx(3),
            ipAndIpx(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates which network transports over which
                the agent will currently accept SNMP requests."
    ::= { s3AgentSw 20 }

s3AgentIpAddr OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The Agent's administrative IP address. The
                current operational IP address can be obtained
                by the ipAdEntAddr entry in the ipAddrTable.

                This parameter will take effect only after a
                restart (s3AgentRestart) is issued. This parameter
                will not survive a reset (s3AgentReset) unless it
                is written into EEPROM (s3AgentWriteEeprom). This
                parameter is used only if the s3AgentBootMode is
                set to use EEPROM."
    ::= { s3AgentIpProtocol 1 }

s3AgentNetMask OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The Agent's administrative subnet mask. The
                current operational subnet mask can be obtained
                by the ipAdEntNetMask entry in the ipAddrTable.

                This parameter will take effect only after a
                restart (s3AgentRestart) is issued. This parameter
                will not survive a reset (s3AgentReset) unless it 
                is written into EEPROM (s3AgentWriteEeprom). This
                parameter is used only if the agentBootMode is set
                to use EEPROM.

                NOTE:  The Model 331x (3313, 3313M, 3314-ST,
                3314M-ST) Ethernet NMM agents do not store this
                parameter in EEPROM, so for these agents the subnet
                mask configuration must be downloaded in the
                configuration file."
    ::= { s3AgentIpProtocol 2 }

s3AgentDefaultGateway OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The Agent's administrative default gateway IP
                address. The current operational default gateway's
                IP address can be obtained from the ipRoutingTable.

                This parameter will take effect only after a
                restart (s3AgentRestart) is issued.  This parameter
                will not survive a reset (s3AgentReset) unless it 
                is written into EEPROM (s3AgentWriteEeprom).  This
                parameter is used only if the agentBootMode is set
                to use EEPROM."
    ::= { s3AgentIpProtocol 3 }

s3AgentBootServerAddr OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The IP address to which the requests for boot files
                are sent. The protocol used to retrieve the boot
                files is determined by object s3AgentBootProtocol.

                This parameter will not take effect until until
                written into EEPROM (s3AgentWriteEeprom) and a
                reset (s3AgentReset) is issued. This parameter is
                used only if the s3AgentBootMode is set to use EEPROM."
    ::= { s3AgentIpProtocol 4 }

s3AgentSecDefaultGateway OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The agent's administrative secondary default
                gateway IP address. This default gateway's IP
                address will be used when the primary default
                gateway (s3AgentDefaultGateway) is determined
                unreachable.

                This parameter will not survive a reset (s3AgentReset)
                unless it is written into EEPROM (s3AgentWriteEeprom)."
    ::= { s3AgentIpProtocol 5 }

s3AgentPingDefaultRtrSwitch OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Controls whether the agent will periodically send
                out the icmp echos (pings) to the default router(s).
                The values are:
                  other(1)...unknown or other
                  on(2)......agent will periodically send out pings
                               to the default router(s).
                  off(3).....agent won't send out the pings to the
                               default router(s)."
    ::= { s3AgentIpProtocol 6 }

s3AgentPingDefaultRtrTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The time interval that the agent uses to send
                out the pings periodically to the default router(s)
                to check if the router(s) are still reachable."
    ::= { s3AgentIpProtocol 7 }

s3AgentBootRouter OBJECT-TYPE
    SYNTAX  IpAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The default route IP address used at boot
                time to download the NMM's agent configuration
                and image files from the TFTP server.

                This parameter will not survive a reset
                (s3AgentReset) unless it is written into EEPROM
                (s3AgentWriteEeprom)."
    ::= { s3AgentIpProtocol 8 }

s3AgentIpxAddr OBJECT-TYPE
    SYNTAX  IpxAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The current IPX address used by this agent."
    ::= { s3AgentIpxProtocol 1 }

s3AgentUnAuthIpx OBJECT-TYPE
    SYNTAX  IpxAddress
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object contains the IPX address of the last
                station that tried to access this agent with an
                invalid community string. This object is used as
                a VarBind in an authentication trap PDU.  A GET
                request will return the last value used, and will
                return an address of zeros if no IPX
                authentication trap has been sent."
    ::= { s3AgentIpxProtocol 3 }

s3AgentTrapReceiverTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3AgentTrapReceiverEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Table containing list of NMS's that are to receive
                traps generated by this NMM."
    ::= { s3SnmpAgent 3 }

s3AgentTrapReceiverEntry OBJECT-TYPE
    SYNTAX  S3AgentTrapReceiverEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A destination address and community string to a
                particular trap server, along with a trap filter
                and entry aging capability."
    INDEX   { s3AgentTrapRcvrNetAddress }
    ::= { s3AgentTrapReceiverTable 1 }

S3AgentTrapReceiverEntry ::= SEQUENCE {
    s3AgentTrapRcvrStatus
        INTEGER,
    s3AgentTrapRcvrNetAddress
        OCTET STRING,
    s3AgentTrapRcvrComm
        OCTET STRING,
    s3AgentTrapRcvrAgeTime
        TimeTicks
    }

s3AgentTrapRcvrStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            valid(2),
            invalid(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Setting this object to the value invalid(3) has
                the effect of invalidating the corresponding entry
                in the s3AgentTrapReceiverTable.  That is, it 
                effectively disassociates the address identified
                with the entry by removing the entry from the table.
                On a read the value of valid(2) should be returned
                if the entry contains a valid record, or invalid(3)
                should be returned if the entry contains an invalid
                record."
    ::= { s3AgentTrapReceiverEntry 1 }

s3AgentTrapRcvrNetAddress OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "IP address for trap server that is to receive
                the trap."
    ::= { s3AgentTrapReceiverEntry 2 }

s3AgentTrapRcvrComm OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..20))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Community string used for traps sent to this
                trap receiver."
    ::= { s3AgentTrapReceiverEntry 3 }

s3AgentTrapRcvrAgeTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This is the time interval used to age entries out
                of the trap receiver table.  The default value if
                not specified will be 0, or infinite, never to be
                aged out."
    ::= { s3AgentTrapReceiverEntry 4 }

s3AgentStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            offline(1),
            online(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the NMM is online(2) and
                operating, or offline(1) (ie: not connected to the
                concentrator backplane).

                ***ACCESS VARIATION - changed access from read-only"
    ::= { s3AgentHw 1 }

s3AgentMdaHwVer OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The network management module's MDA hardware
                version number  (0=Rev. A, 1=Rev. B, etc.)."
    ::= { s3AgentHw 2 }

s3AgentMode OBJECT-TYPE
    SYNTAX  INTEGER {
            primary(1),
            secondary(2),
            other(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the NMM is operating in
                primary(1) or secondary(2) mode.

                ***ACCESS VARIATION - changed access from read-write"
    ::= { s3AgentHw 3 }

s3AgentReset OBJECT-TYPE
    SYNTAX  INTEGER {
            noReset(1),
            reset(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Network management module reset status.  Writing
                a reset(2) to this object will reset the NMM and
                perform a download and restart."
    ::= { s3AgentHw 4 }

s3AgentRestart OBJECT-TYPE
    SYNTAX  INTEGER {
            noRestart(1),
            restart(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Network management module restart status.
                Writing a restart(2) to this object will restart
                the NMM.  This initializes all the counters,
                re-reads the EEPROM data structure and starts
                executing from the beginning of the code."
    ::= { s3AgentHw 5 }

s3AgentBootMode OBJECT-TYPE
    SYNTAX  INTEGER {
            eeprom(1),
            net(2),
            otherCase(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The method for obtaining boot parameter information.
                The possible values are:
                  eeprom(1)......get boot info from eeprom
                  net(2).........get boot info from remote server
                  otherCase(3)...not eeprom or net

                This parameter will not take effect until written
                into EEPROM (s3AgentWriteEeprom) and a reset
                (s3AgentReset) is issued.

                Note: In previous versions of this MIB the name
                      associated with the value '2' was 'other',
                      which implied the same meaning as it does
                      now.  Thus to prevent confusion, the name
                      for value '3' was chosen to be 'otherCase'."
    ::= { s3AgentHw 6 }

s3AgentWriteEeprom OBJECT-TYPE
    SYNTAX  INTEGER {
            noWriteEeprom(1),
            writeEeprom(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Network management module EEPROM write status.
                Writing a (2) to this object will write the contents
                of current EEPROM data structure in the EEPROM."
    ::= { s3AgentHw 7 }

s3AgentBaudRate OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Specifies the baud rate in bits per second of
                either the internal modem or the RS-232 port.

                This parameter will take effect only after a
                restart (s3AgentRestart) is issued.  This parameter
                will not survive a reset (s3AgentReset) unless
                the specific NMM configuration file is updated
                to reflect the change."
    ::= { s3AgentHw 8 }

s3AgentInitString OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..64))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This is the initialization string used to establish
                the out-of-band connection. (i.e. could contain the
                string ATDT,415-960-1100 for an internal or external
                modem). This is used as a hint for the network manager
                since this string is not used by the agent to initiate
                a connection to a management station.

                This parameter will take effect only after a restart
                (s3AgentRestart) is issued.  This parameter will not
                survive a reset (s3AgentReset) unless the specific
                NMM configuration file is updated to reflect
                the change."
    ::= { s3AgentHw 9 }

s3AgentEepromSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of the EEPROM of the agent in units of bytes."
    ::= { s3AgentHw 10 }

s3AgentEpromSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of the EPROM of the agent in units of bytes."
    ::= { s3AgentHw 11 }

s3AgentDramSize OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of the DRAM of the agent in units of bytes."
    ::= { s3AgentHw 12 }

s3AgentHexDisplay OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..4))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The current 4 ASCII character display of the agent.

                Agents with no hex display hardware should return a
                zero length string."
    ::= { s3AgentHw 13 }

s3AgentFlashStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ok(2),
            fail(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates the operational status of the flash
                device of the agent.  A fail(3) indicates that either
                the flash device configuration on board is not valid
                or the flash EEPROMs on the board have failed."
    ::= { s3AgentHw 14 }

s3LocImageValid OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            localImageValid(2),
            localImageInvalid(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the agent has a valid local
                code image on board.  An EPROM checksum failure would
                cause the agent to return localImageInvalid(3)."
    ::= { s3AgentLocImage 1 }

s3LocImageMajorVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The major software version number of the
                locally-stored image.  This object applies only to
                agents with valid local image.  Other agents 
                should return zero."
    ::= { s3AgentLocImage 2 }

s3LocImageMinorVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The minor software version number of the
                locally-stored image.  This object applies only
                to agents with valid local image.  Other agents
                should return zero."
    ::= { s3AgentLocImage 3 }

s3LocImageLoadMode OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            remoteBoot(2),
            localBoot(3),
            localAsBackup(4),
            remoteNoUpdate(5),
            remoteNewUpdate(6),
            localAutoUpdate(7)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the agent should get code
                from the network, use a local image, or try the
                network first and then fall back to local image if 
                the network boot fails. The localBoot(3) and
                localAsBackup(4) values apply only to agents with
                local load option. Note: on agents that have
                no local storage, either remoteBoot(2), or
                remoteNoUpdate(5) may be specified, however
                the value remoteBoot(2) is prefered due to
                backwards compatibility "
    ::= { s3AgentLocImage 4 }

s3LocImageActualSource OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            remoteImage(2),
            localImage(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates whether the agent loaded code from
                the network or used a local image.  When the the
                ImageLoadMode is localAsBackup, this variable
                indicates whether the network load was successful."
    ::= { s3AgentLocImage 5 }

s3LocImageMaintVersion OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The maintenance software version number of the
                locally-stored image.  This object applies only
                to agents with valid local image.  Other agents
                should return zero."
    ::= { s3AgentLocImage 6 }

s3AgentIpxTrapReceiverTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3AgentIpxTrapReceiverEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Table containing list of NMS's that are to receive
                traps generated by this NMM sent over IPX."
    ::= { s3SnmpAgent 7 }

s3AgentIpxTrapReceiverEntry OBJECT-TYPE
    SYNTAX  S3AgentIpxTrapReceiverEntry
    ACCESS  not-accessible
    STATUS  mandatory
    INDEX   { s3AgentIpxTrapRcvrNetAddress }
    ::= { s3AgentIpxTrapReceiverTable 1 }

S3AgentIpxTrapReceiverEntry ::= SEQUENCE {
    s3AgentIpxTrapRcvrStatus
        INTEGER,
    s3AgentIpxTrapRcvrNetAddress
        IpxAddress,
    s3AgentIpxTrapRcvrComm
        OCTET STRING,
    s3AgentIpxTrapRcvrAgeTime
        TimeTicks
    }

s3AgentIpxTrapRcvrStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            valid(2),
            invalid(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Action/status for the row. The values that can
                be written are:
                  valid(2).....create row
                  invalid(3)...delete row

                The values that can be read are:
                  other(1).....some unknown case
                  valid(2).....row is valid
                  invalid(3)...row is invalid

                Setting this object to the value invalid(3) has the
                effect of invalidating the corresponding entry in
                the s3AgentIpxTrapReceiverTable.  That is, it
                effectively disassociates the address identified
                with the entry by removing the entry from the table
                On a read the value of valid(2) should be returned
                if the entry contains a valid record, or invalid(3)
                should be returned if the entry contains an invalid
                record."
    ::= { s3AgentIpxTrapReceiverEntry 1 }

s3AgentIpxTrapRcvrNetAddress OBJECT-TYPE
    SYNTAX  IpxAddress
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "IPX address for trap server that is to receive the
                trap.  The value may only be written when the row
                is created."
    ::= { s3AgentIpxTrapReceiverEntry 2 }

s3AgentIpxTrapRcvrComm OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(0..20))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Community string used for traps sent to this
                trap receiver."
    ::= { s3AgentIpxTrapReceiverEntry 3 }

s3AgentIpxTrapRcvrAgeTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This is the time interval used to age entries out of
                the trap receiver table.  The default value if not
                specified will be 0, or infinite, never to be 
                aged out."
    ::= { s3AgentIpxTrapReceiverEntry 4 }

s3ChassisType OBJECT-TYPE
    SYNTAX  SnpxChassisType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The chassis type."
    ::= { s3000Chassis 1 }

s3ChassisBkplType OBJECT-TYPE
    SYNTAX  SnpxBackplaneType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The chassis backplane type."
    ::= { s3000Chassis 2 }

s3ChassisBkplRev OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The chassis backplane revision."
    ::= { s3000Chassis 3 }

s3ChassisPsType OBJECT-TYPE
    SYNTAX  S3PsType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The chassis power supply type.  This value is
                valid only when the backplane type is not
                other(1).  If the chassis has a redundant backplane,
                the agent returns redundantCapable(5), even if only
                one power supply is installed.  The objects
                s3RedPsPrimaryConfig and s3RedPsSecondaryConfig
                should be consulted to determine the installed
                power supply type(s) with redundant backplanes."
    ::= { s3000Chassis 4 }

s3ChassisPsStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            ok(1),
            primaryFail(2),
            secondaryFail(3),
            bothFail(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The chassis power supply status."
    ::= { s3000Chassis 5 }

s3ChassisFanStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            ok(1),
            fail(2),
            other(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The status of the chassis cooling fan."
    ::= { s3000Chassis 6 }

s3SlotConfigTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3SlotConfigEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "The chassis slot configuration table."
    ::= { s3000Chassis 7 }

s3SlotConfigEntry OBJECT-TYPE
    SYNTAX  S3SlotConfigEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "What type of module is in each slot of the chassis."
    INDEX   { s3SlotNumber }
    ::= { s3SlotConfigTable 1 }

S3SlotConfigEntry ::= SEQUENCE {
    s3SlotNumber
        INTEGER,
    s3SlotModuleId
        INTEGER,
    s3SlotModuleType
        S3ModuleType,
    s3SlotModuleDescr
        DisplayString,
    s3SlotModuleLed
        OCTET STRING,
    s3SlotModuleMdaId
        INTEGER
    }

s3SlotNumber OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The 3000 Chassis slot number. Valid entries are 1-12."
    ::= { s3SlotConfigEntry 1 }

s3SlotModuleId OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "ID for the module.  Values are specified in
                SynOptics technical documents."
    ::= { s3SlotConfigEntry 2 }

s3SlotModuleType OBJECT-TYPE
    SYNTAX  S3ModuleType
    ACCESS  read-only
    STATUS  deprecated
    DESCRIPTION
                "The type of module this entry represents.
                Values are specified in SynOptics technical documents."
    ::= { s3SlotConfigEntry 3 }

s3SlotModuleDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Module description.  Values are specified in
                SynOptics technical documents."
    ::= { s3SlotConfigEntry 4 }

s3SlotModuleLed OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(8))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Status of the module LEDs.  Format is specified in
                SynOptics technical documents.  NOTE: the 291x FDDI
                workgroup concentrators actually return a string
                with size of 10."
    ::= { s3SlotConfigEntry 5 }

s3SlotModuleMdaId OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "ID of the medium-dependent part of the board.
                The value is board dependent. Values are specified
                in SynOptics technical documents."
    ::= { s3SlotConfigEntry 6 }

s3CommonBoardTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3CommonBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing information about the boards
                currently plugged into the 3000 Chassis.  This
                board table contains an entry for each non-empty
                slot in the s3SlotConfigTable, EXCEPT for those
                slots containing Retiming Modules.

                All of the information in this board table is
                retrievable using the NMI commands that are common
                to all boards integrated into the SynOptics
                Series 3000 Concentrators."
    ::= { s3000Chassis 8 }

s3CommonBoardEntry OBJECT-TYPE
    SYNTAX  S3CommonBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table entry containing information about a
                single Board currently plugged into the 3000
                Chassis. These values can be retrieved using the
                common board NMI commands."
    INDEX   { s3CommonBoardIndex }
    ::= { s3CommonBoardTable 1 }

S3CommonBoardEntry ::= SEQUENCE {
    s3CommonBoardIndex
        INTEGER,
    s3CommonBoardId
        INTEGER,
    s3CommonBoardHwVer
        INTEGER,
    s3CommonBoardStatus
        INTEGER,
    s3CommonBoardReset
        INTEGER,
    s3CommonBoardPartStatus
        INTEGER,
    s3CommonBoardNmCntlStatus
        INTEGER,
    s3CommonBoardPsStatus
        INTEGER,
    s3CommonBoardPartTime
        TimeTicks
    }

s3CommonBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board. Its value ranges
                between 1 and 12. The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3CommonBoardEntry 1 }

s3CommonBoardId OBJECT-TYPE
    SYNTAX  INTEGER {
            m331x(1),
            m3302(2),
            m332x(3),
            m3304ST(4),
            m3305(5),
            m333x(6),
            m3307(7),
            m3308(8),
            m3301(9),
            m3904(10),
            m3902(11),
            m3910S(12),
            m331xS(14),
            m3100R(15),
            m3502(16),
            m3502A(17),
            m353x(18),
            m3040(19),
            m3505(20),
            m3505A(21),
            m355x(22),
            m3040S(23),
            m351x(24),
            m332xS(25),
            m338x(26),
            m3328(27),
            m3395(28),
            m3394(29),
            m3522(30),
            m3395A(31),
            m3800(32),
            m3368(36),
            m3308A(38),
            m2810nmm(39),
            m2810hm(40),
            m3301ohms75(41),
            m3301ohms93(42),
            m2912(43),
            m2914(44),
            m3502B(45),
            m3505B(46),
            m3307HD(47),
            m2702Fhm(48),
            m2712Fhm(49),
            m2712hm(50),
            m2702hm(51),
            m2813nmm(52),
            m2813hm(53),
            m2814hm(54),
            m2803hm(55),
            m3356(56),
            m2814nmm(57),
            m2804hm(58),
            m2702Chm(59),
            m2715Fhm(60),
            m2705Fhm(61),
            m2705Chm(62),
            m3902A(63),
            m2912A(64),
            m271xnmm(65),
            m2715hm(66),
            m3910SSD(67),
            m3313A(68),
            m3314A(69),
            m3304A(70),
            m3910SA(71),
            m2705hm(72),
            m3905(73),
            m2915(74),
            m2715Bhm(75),
            m2705Bhm(76),
            m2715BFhm(77),
            m2712Bhm(78),
            m2712BFhm(79),
            m2702BChm(80),
            m3486(82),
            m810m(88),
            m3517SA(101),
            m3308B(102),
            m2813SAnmm(103),
            m2814SAnmm(104),
            m3313SA(105),
            m3314SA(106),
            m3174(107),
            m3522A(108),
            m3513SA(109),
            m271xSAnmm(110),
            m3299C(116),
            m3299U(117),
            m3299F(119),
            mAlcatelEthConcnmm(250),
            mAlcatelEthConchm(251)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This is the ID of the board, which is 'hard-coded' in the
                board, and identifies the board's basic functionality.
                Some boards have the capability to change aspects of
                their functionality, such as media type, interface types,
                or power supply wattages, by plugging in different daughter
                cards.  Other boards may identify the type of cable plugged
                into them.  The boards that have these capabilities use 
                different values for the object s3SlotModuleMda to identify
                the changable portion of the functionality currently used.
                Boards that do not support these capabilities typically set
                the object s3SlotModuleMda to 255 or zero.  The combination
                of the value of this object and the s3SlotModuleMda object
                are then mapped by software to determine the type of
                module (i.e., s3SlotModuleType).

                Notes:  1.)  The object s3SlotModuleType is marked
                             as deprecated.
                        2.)  Agents do not implement a complete mapping of
                             s3CommonBoardId and s3SlotModuleMda to
                             s3SlotModuleType.  The mapping that is performed
                             pertains to the media type of the agent.

                The possible values for this object are:
                  m331x(1)...................331x Ethernet NMM
                  m3302(2)...................3302 Ethernet STP Host
                  m332x(3)...................332x Ethernet Local Bridge
                  m3304ST(4).................3304 Ethernet FOIRL-ST Host
                  m3305(5)...................3305 Ethernet UTP Host
                  m333x(6)...................333x Ethernet Repeater/Retiming
                  m3307(7)...................3307 Ethernet 50 Pin UTP Host
                  m3308(8)...................3308 10BaseT UTP Host
                  m3301(9)...................3301 10Base2 Thin Net Host
                  m3904(10)..................3904 FDDI Multimode Fiber Host
                  m3902(11)..................3902 FDDI STP Host
                  m3910S(12).................3910S FDDI NMM
                  m331xS(14).................331xS Ethernet NMM
                  m3100R(15).................3100R Power Supply Summing
                  m3502(16)..................3502 Token Ring Passive STP Host
                  m3502A(17).................3502A Token Ring Passive STP/UTP Host
                  m353x(18)..................353x Token Ring RI/RO Repeater
                  m3040(19)..................3040 Network Control Engine (NCE)
                  m3505(20)..................3505 Token Ring Active UTP Host
                  m3505A(21).................3505A Token Ring Active UTP Host
                  m355x(22)..................355x Token Ring FOIRL RI/RO Repeater
                  m3040S(23).................3040S Network Control Engine
                  m351x(24)..................351x Token Ring NMM
                  m332xS(25).................332xS Ethernet High Speed Local Bridge
                  m338x(26)..................338x Ethernet Remote Router
                  m3328(27)..................3328 Ethernet Switching Engine (ESE)
                  m3395(28)..................3395 Terminal Server
                  m3394(29)..................3394 LattisTalk Router/Repeater
                  m3522(30)..................3522 Token Ring Local Bridge
                  m3395A(31).................3395A Terminal Server
                  m3800(32)..................3800 Multimedia Router
                  m3368(36)..................3368 Ethernet LattisSecure Host
                  m3308A(38).................3308A 10BaseT Host
                  m2810nmm(39)...............2810 Ethernet NMM
                  m2810hm(40)................2810 Ethernet Host
                  m3301ohms75(41)............3301-75 Ethernet Thin Net Host (75-ohm)
                  m3301ohms93(42)............3301-93 Ethernet Thin Net Host (93-ohm)
                  m2912(43)..................2912 FDDI STP Concentrator
                  m2914(44)..................2914 FDDI Fiber Concentrator
                  m3502B(45).................3502B Token Ring Passive STP/UTP Host
                  m3505B(46).................3505B Token Ring Active STP/UTP Host
                  m3307HD(47)................3307HD Ethernet 100 Pin UTP Host
                  m2702Fhm(48)...............2702F Token Ring Passive Host
                  m2712Fhm(49)...............2712F Token Ring Passive Host
                  m2712hm(50)................2712 Token Ring Passive Host
                  m2702hm(51)................2702 Token Ring Passive Host
                  m2813nmm(52)...............2813 Ethernet NMM
                  m2813hm(53)................2813 Ethernet Host
                  m2814hm(54)................2814 Ethernet Host
                  m2803hm(55)................2803 Ethernet Host
                  m3356(56)..................3356 Ethernet Remote Bridge
                  m2814nmm(57)...............2814 Ethernet NMM
                  m2804hm(58)................2804 Ethernet Host
                  m2702Chm(59)...............2702C Token Ring Passive Host
                  m2715Fhm(60)...............2715F Token Ring Active Host
                  m2705Fhm(61)...............2705F Token Ring Active Host
                  m2705Chm(62)...............2705C Token Ring Active Host
                  m3902A(63).................3902A FDDI STP Host
                  m2912A(64).................2912A FDDI STP Concentrator
                  m271xnmm(65)...............271x Token Ring NMM
                  m2715hm(66)................2715 Token Ring Active Host
                  m3910SSD(67)...............3910S-SD FDDI NMM
                  m3313A(68).................3313A Ethernet NMM
                  m3314A(69).................3314A Ethernet NMM
                  m3304A(70).................3304A Ethernet 10BaseF Host
                  m3910SA(71)................3910SA FDDI NMM
                  m2705hm(72)................2705 Token Ring Active Host
                  m3905(73)..................3905 FDDI UTP Host
                  m2915(74)..................2915 FDDI UTP Concentrator
                  m2715Bhm(75)...............2715B Token Ring Active Host
                  m2705Bhm(76)...............2505B Token Ring Active Host
                  m2715BFhm(77)..............2715B-F Token Ring Active Host
                  m2712Bhm(78)...............2712B Token Ring Passive Host
                  m2712BFhm(79)..............2712B-F Token Ring Passive Host
                  m2702BChm(80)..............2702B-C Token Ring Passive Host
                  m3486(82)..................3486 LattisEngine/486
                  m810m(88)..................810M Ethernet Concentrator
                  m3517SA(101)...............3517SA Token Ring NMM
                  m3308B(102)................3308B 10BaseT Host
                  m2813SAnmm(103)............2813SA Ethernet NMM
                  m2814SAnmm(104)............2814SA Ethernet NMM
                  m3313SA(105)...............3313SA Ethernet NMM
                  m3314SA(106)...............3314SA Ethernet NMM
                  m3174(107).................3174 Workstation Controller
                  m3522A(108)................3522A Token Ring Local Bridge
                  m3513SA(109)...............3513SA Token Ring NMM
                  m271xSAnmm(110)............271xSA Token Ring NMM
                  m3299C(116)................3299-C Terminal Multiplexor Adapter
                  m3299U(117)................3299-U TTP Terminal Multiplexor Adapter
                  m3299F(119)................3299-F Fiber Optic Terminal Adapter
                  mAlcatelEthConcnmm(250)....Alcatel Ethernet NMM
                  mAlcatelEthConchm(251).....Alcatel Ethernet Host"
    ::= { s3CommonBoardEntry 2 }

s3CommonBoardHwVer OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The hardware revision of the board.
                  0=Rev. A, 1=Rev. B, etc."
    ::= { s3CommonBoardEntry 3 }

s3CommonBoardStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            ok(1),
            fail(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates the operational status of the board."
    ::= { s3CommonBoardEntry 4 }

s3CommonBoardReset OBJECT-TYPE
    SYNTAX  INTEGER {
            noReset(1),
            reset(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This indicates the reset state of the board.
                Writing with the value reset (2) will reset
                the board."
    ::= { s3CommonBoardEntry 5 }

s3CommonBoardPartStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            partition(2),
            timedPartition(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Tells whether the board is partitioned or enabled.
                Writing with the value partition(2) will partition
                the board indefinitely and writing with the value
                enabled(1) will enable the board.

                If a timed partition is desired, then this object
                must be written with timedPartition(3) and in the
                same PDU a partition duration must be supplied in
                s3CommonBoardPartTime. Timed partitions will not
                survive across a reset. In this case the port will
                go to the partition(2) state.

                Boards cannot be partitioned in the 2810 concentrator
                and other workgroup concentrators. These agents will
                implement this object as read-only."
    ::= { s3CommonBoardEntry 6 }

s3CommonBoardNmCntlStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            notNmControl(1),
            nmControl(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Tells whether the board is under network management
                control.  The value nmControl(2) indicates that the
                board or one or more ports are being controlled by
                network management.  This means that the board
                or one or more ports are partitioned via a network
                manager."
    ::= { s3CommonBoardEntry 7 }

s3CommonBoardPsStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            ok(1),
            fail(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates the operational status of the board
                power supply.  A fail(2) indicates that one of the
                power supplies on the board has failed."
    ::= { s3CommonBoardEntry 8 }

s3CommonBoardPartTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "When partitioning the board for a specified time, 
                s3CommonBoardPartStatus must be set with
                timedPartition(3) and this object must be supplied
                with the duration value. If a PDU sets 
                s3CommonBoardPartStatus and not this object, the
                board will not be partitioned.  This value is
                decremented while the board is partitioned
                until the value reaches zero at which time the
                board is enabled."
    ::= { s3CommonBoardEntry 9 }

s3SlotConfigOctetString OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(12..144))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Packed octet string for the slot configuration table.
                Format is specified in SynOptics technical documents.
                NOTE: the 291x FDDI workgroup concentrators actually
                return a string with size a multiple of 14."
    ::= { s3000Chassis 9 }

s3RedPsPlus5vCurrent OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This gauge is measured in amperes."
    ::= { s3000RedundantPs 1 }

s3RedPsPlus12vCurrent OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This gauge is measured in amperes."
    ::= { s3000RedundantPs 2 }

s3RedPsAmbientTempStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            normalTemperature(2),
            aboveNormalTemp(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This status indicates whether the ambient
                temperature is  normal, i.e., below 40 degree C."
    ::= { s3000RedundantPs 3 }

s3RedPsAmbientTemperature OBJECT-TYPE
    SYNTAX  Gauge
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This gauge is measured in Celsius."
    ::= { s3000RedundantPs 4 }

s3RedPsPrimaryConfig OBJECT-TYPE
    SYNTAX  S3PsType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates the primary power supply type
                (PS 1).  Note that value redundantCapable(5)
                should not be returned for this object."
    ::= { s3000RedundantPs 5 }

s3RedPsSecondaryConfig OBJECT-TYPE
    SYNTAX  S3PsType
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This indicates the secondary power supply type
                (PS 2).  Note that value redundantCapable(5)
                should not be returned for this object."
    ::= { s3000RedundantPs 6 }

s3RedPsDiodeStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            bothOk(2),
            primaryFail(3),
            secondaryFail(4),
            bothFail(5)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This gives the status of the summing diode on the
                3100R associated with the indicated power supply."
    ::= { s3000RedundantPs 7 }

s3RedPsPowerAlarm OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            bothOk(2),
            primaryFail(3),
            secondaryFail(4),
            bothFail(5)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This tells whether the indicated power supply is
                sensing voltage on the backplane."
    ::= { s3000RedundantPs 8 }

s3ChassisBkPlEthChanDiv OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A value that describes the divisions of the
                segmentable ethernet channel.  For those devices
                that do not implement a backplane with this feature,
                they still need to implement this object and return
                a value (i.e., zero) to indicate that no divisions
                are enabled.

                The value is a sum (i.e., integer bit string).
                This value initially takes the value of zero,
                then for each division that is enabled on the channel,
                2 raised to a power is added to the sum.  The powers
                are according to the following table:

                  Division between    Power
                    Slots 4 and 5     0
                    Slots 6 and 7     1
                    Slots 8 and 9     2

                For example, a channel with no divisions enabled
                (i.e., not segmented) would have a value of 0.
                A channel with divisions between slots 6 and 7,
                and slots 8 and 9 enabled (i.e., having three
                segments) would have a value of 6 (2**1 + 2**2)."
    ::= { s3000Chassis 11 }

s3ChassisEnetChannelAType OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            aSegmentable(2),
            aNotSegmentable(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent will return aSegmentable(2) for the 3000N,
                3000NT, 3000S, 3000SR, and any other backplanes in
                which Ethernet channel A can be divided into multiple
                segments.  The value aNotSegmentable(3) indicates
                that the Ethernet backplane channel A cannot be
                segmented.

                For Token Ring or FDDI workgroup concentrators, or
                other devices in which there is no Ethernet channel,
                the agent will return other(1)."
    ::= { s3000Chassis 12 }

s3EnetConcRetimingStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            off(1),
            on(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Does this concentrator have retiming turned on.
                Writing a 1 will turn off retiming and writing a
                2 will turn on retiming.  This will change the
                active state of retiming but will change the value
                in EEPROM only when agentWriteEeprom is set.The
                factory default of this state is on.

                Retiming cannot be disabled in the 2810 concentrator.
                The 2810 agent will implement this object as read-only."
    ::= { s3000EnetConcentrator 1 }

s3EnetConcFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the concentrator.  This does not include
                frames received with a frame-too-long, runt, FCS, or
                alignment errors.

                This counter includes broadcast and multicast frames
                that are received."
    ::= { s3000EnetConcentrator 2 }

s3EnetConcOctetsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Contains a count of data and padding octets in frames
                that are successfully received by the concentrator.
                This does not include frames received with a
                frame-too-long, runt, FCS, or alignment errors.

                This counter includes octets in broadcast and multicast
                frames that are received.

                This counter does not include the octets in the
                CRC field. The octets in the address and length/type
                fields are counted."
    ::= { s3000EnetConcentrator 3 }

s3EnetConcMcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the concentrator and are directed to an
                active non-broadcast group address.  This does not
                include frames received with a frame-too-long, runt,
                FCS, or alignment errors.

                Only frames that are for a multicast address that
                this interface is receiving are counted.  Broadcast
                packets are not included."
    ::= { s3000EnetConcentrator 4 }

s3EnetConcBcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the concentrator and are directed to the
                broadcast group address.  This does not include frames
                received with a frame-too-long, runt, FCS, or
                alignment errors.

                Multicast packets are not included."
    ::= { s3000EnetConcentrator 5 }

s3EnetConcColls OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the collisions at the
                concentrator level.  For NMM+ this is a true counter.
                For other NMMs this is a summation of all the port
                level collision 'flags' for all ports."
    ::= { s3000EnetConcentrator 6 }

s3EnetConcTooLongErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are received by
                the concentrator and exceed the maximum permitted
                frame size.  This counter is incremented when the
                frameTooLong error is detected."
    ::= { s3000EnetConcentrator 7 }

s3EnetConcRuntErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the
                concentrator that are less than the minimum permitted
                frame size and have a good FCS."
    ::= { s3000EnetConcentrator 8 }

s3EnetConcFragErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the
                concentrator that are less than the minimum permitted
                frame size and have a bad FCS or alignment error."
    ::= { s3000EnetConcentrator 9 }

s3EnetConcAlignErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the
                concentrator that are not an integral number of
                octets in length and do not pass the FCS check.
                This counter is incremented when the alignment
                Error status is detected."
    ::= { s3000EnetConcentrator 10 }

s3EnetConcFcsErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the
                concentrator that are an integral number of octets
                in length that do not pass the FCS check.  This
                counter is incremented when the frame Check Error
                status is detected."
    ::= { s3000EnetConcentrator 11 }

s3EnetConcLateCollErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a total concentrator count of the
                late collisions. For NMM+ this is a true counter.
                For other NMMs this is a summation of all the port
                level late collision 'flags' for all ports."
    ::= { s3000EnetConcentrator 12 }

s3EnetConcSecureStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            concSecureOn(2),
            portCheckOn(3),
            slotCheckOn(4),
            concSecureOff(5)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This s3EnetConcSecureStatus object indicates whether
                the security features (both allowed nodes and
                LattisSecure) for the concentrator are active or
                inactive.  If security is active, this object also
                indicates whether the allowed nodes feature is
                controlled at the concentrator, board, or port level.
                LattisSecure features are always controlled at the
                port level.  (See the Authorized Nodes tables for
                more information about how the allowed nodes and
                LattisSecure receive security features are
                configured.)

                If this object is set to concSecureOn(2), then the
                allowed nodes feature is controlled at the
                concentrator level and activated for every
                non-LattisSecure Ethernet port in the concentrator.
                If an authorized node violation occurs on any port,
                the action specified in s3EnetConcAuthAction is taken.

                If this object is set to portCheckOn(3), then allowed
                nodes is controlled at the port level by the
                s3EnetPortSecureStatus object for that port.  The
                port's s3EnetPortAuthAction determines the action
                taken when authorized nodes violations occur on that
                port.

                If this object is set to slotCheckOn(4), then allowed
                nodes is controlled at the board level by the
                s3EnetBoardSecureStatus object for that board.
                The board's s3EnetBoardAuthAction determines the
                action taken when authorized nodes violations
                occur on that board's ports.

                If this object is set to concentratorOff(5), then
                all security features, including LattisSecure, are
                deactivated for the entire concentrator.

                No matter what the status of this object, the board
                and port level SecureStatus and AuthAction are not
                lost even if they are not currently being used.  Thus,
                the user can change a port's status even if this object
                is slotCheckOn(4).  If this object is then changed to
                portCheckOn(3), then the change will take effect.

                The agent must support download of this object in the
                CFG file.

                In release 4.0, this object was called
                s3EnetConcAuthStatus."
    ::= { s3000EnetConcentrator 13 }

s3EnetConcAuthAction OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            noAction(2),
            sendTrap(3),
            partition(4),
            sendTrapPartition(5)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "If s3EnetConcSecureStatus is concSecureOn(2) and a
                violation occurs, then the action specified by this
                object will take place.  On a partition, only the
                port that the violation occurs on will be partitioned.

                This object does not apply to LattisSecure ports.

                The agent must support download of this object in
                the CFG file."
    ::= { s3000EnetConcentrator 14 }

s3EnetConcSecurityLock OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            locked(2),
            notLocked(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "If s3EnetConcSecurityLock is locked(2), the agent will
                refuse all requests to modify the 'security configuration'
                (defined below) by returning a BadValue return value.
                If s3EnetConcSecurityLock is notLocked(3), requests to
                modify security configuration will be handled in the
                usual manner.  SetRequests for objects not included
                in the security configuration are not affected by the
                state of this object.

                Objects that are part of the security configuration
                are s3EnetConcAuthStatus, s3EnetConcAuthAction,
                s3EnetBoardAuthStatus, s3EnetBoardAuthAction,
                s3EnetPortAuthStatus, s3EnetPortAuthAction,
                s3EnetPortAddrLearnMode, s3EnetPortTxSecurity,
                and all of the objects in the s3EnetAuthNodesTable."
    ::= { s3000EnetConcentrator 15 }

s3EnetConcEnetChan OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            enetA(2),
            enetB(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Identifies the channel to which this NMM is
                currently monitoring."
    ::= { s3000EnetConcentrator 16 }

s3EnetBoardTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of board-related objects.  The number of
                entries is given by the number of Ethernet host
                module and network management module boards that
                are contained in same backplane Ethernet segment
                as the reporting NMM."
    ::= { s3000EnetBoard 1 }

s3EnetBoardEntry OBJECT-TYPE
    SYNTAX  S3EnetBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about Ethernet boards
                which are currently plugged into the 3000 chassis."
    INDEX   { s3EnetBoardIndex }
    ::= { s3EnetBoardTable 1 }

S3EnetBoardEntry ::= SEQUENCE {
    s3EnetBoardIndex
        INTEGER,
    s3EnetBoardFrmsRxOk
        Counter,
    s3EnetBoardOctetsRxOk
        Counter,
    s3EnetBoardMcastFrmsRxOk
        Counter,
    s3EnetBoardBcastFrmsRxOk
        Counter,
    s3EnetBoardColls
        Counter,
    s3EnetBoardTooLongErrors
        Counter,
    s3EnetBoardRuntErrors
        Counter,
    s3EnetBoardAlignErrors
        Counter,
    s3EnetBoardFcsErrors
        Counter,
    s3EnetBoardLateCollErrors
        Counter,
    s3EnetBoardAuthStatus
        INTEGER,
    s3EnetBoardAuthAction
        INTEGER,
    s3EnetBoardUpStamp
        TimeTicks
    }

s3EnetBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the next
                re-initialization."
    ::= { s3EnetBoardEntry 1 }

s3EnetBoardFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the board.  This does not include frames
                received with a frame-too-long, runt, FCS, or alignment
                errors.

                This counter includes broadcast and multicast frames
                that are received."
    ::= { s3EnetBoardEntry 9 }

s3EnetBoardOctetsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Contains a count of data and padding octets in frames
                that are successfully received by the board.  This does
                not include frames received with a frame-too-long, runt,
                FCS, or alignment errors.

                This counter includes octets in broadcast and multicast
                frames that are received.

                This counter does not include the octets in the
                CRC field. The octets in the address and length/type
                fields are counted."
    ::= { s3EnetBoardEntry 10 }

s3EnetBoardMcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the board and are directed to an active
                non-broadcast group address.  This does not include
                frames received with a frame-too-long, runt, FCS, or
                alignment errors.

                Only frames that are for a multicast address that
                this interface is receiving are counted. Broadcast
                packets are not included."
    ::= { s3EnetBoardEntry 11 }

s3EnetBoardBcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the board and are directed to the broadcast
                group address.  This does not include frames received
                with a frame-too-long, runt, FCS, or alignment errors.
                Multicast packets are not included."
    ::= { s3EnetBoardEntry 12 }

s3EnetBoardColls OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a board level count of collisions.
                For NMM+ this is a true counter.  For other NMMs
                this is a summation of all the port level collision
                'flags' for this board."
    ::= { s3EnetBoardEntry 13 }

s3EnetBoardTooLongErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are received by
                the board and exceed the maximum permitted frame size.
                This counter is incremented when the frameTooLong
                error is detected."
    ::= { s3EnetBoardEntry 14 }

s3EnetBoardRuntErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the board
                that are less than the minimum permitted frame size and
                have a good FCS."
    ::= { s3EnetBoardEntry 15 }

s3EnetBoardAlignErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the board
                that are not an integral number of octets in length and
                do not pass the FCS check.  This counter is incremented
                when the alignmentError status is detected."
    ::= { s3EnetBoardEntry 16 }

s3EnetBoardFcsErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the board
                that are an integral number of octets in length that
                do not pass the FCS check.  This counter is incremented
                when the frameCheckError status is detected."
    ::= { s3EnetBoardEntry 17 }

s3EnetBoardLateCollErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the board level late collisions.
                For NMM+ this is a true counter.  For other NMMs this is a
                summation of all the port level late collision 'flags' for
                this board."
    ::= { s3EnetBoardEntry 18 }

s3EnetBoardAuthStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This object is only used if s3EnetConcSecureStatus is
                set to slotCheckOn(4).  In this case, turning this object
                on(2) means that any node that is heard on this board
                which is not allowed on this board (i.e., not in AuthNode
                table with the slotIndex equal to this board or 0 for all
                boards) will cause the action specified in
                s3EnetBoardAuthAction to take place.

                If s3EnetConcSecureStatus is set to slotCheckOn(4) but
                this object is set to off(3), then the authorized nodes
                feature for this board is deactivated.

                If s3EnetConcSecureStatus is not set to slotCheckOn(4),
                then this object will not be used but will maintain
                its settings unless explicitly changed.

                This object does not affect the configuration or
                functioning of security features on LattisSecure
                Host Modules."
    ::= { s3EnetBoardEntry 19 }

s3EnetBoardAuthAction OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            noAction(2),
            sendTrap(3),
            partition(4),
            sendTrapPartition(5)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "If s3EnetConcSecureStatus is slotCheckOn(4) and
                s3EnetBoardAuthStatus is on(2) and an authorized nodes
                violation occurs on the board, then the action specified
                by this object will take place.  On a partition, only the
                port that the violation occurs on will be partitioned.

                This object does not apply to LattisSecure ports."
    ::= { s3EnetBoardEntry 20 }

s3EnetBoardUpStamp OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The time ( in hundredths of a second) that the board
                was first seen as a member of this NMM's segment."
    ::= { s3EnetBoardEntry 21 }

s3EnetLocBridgeSlotTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetLocBridgeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of Local Bridge Board entries.  The number of
                entries is determined by  the Concentrator Slot
                Configuration Table.  Only those entries that are
                Ethernet local bridges will have entries in this list."
    ::= { s3000EnetLocBridge 1 }

s3EnetLocBridgeEntry OBJECT-TYPE
    SYNTAX  S3EnetLocBridgeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about Boards which are
                local bridges that are currently plugged into the
                3000 chassis."
    INDEX   { s3EnetLocBridgeIndex }
    ::= { s3EnetLocBridgeSlotTable 1 }

S3EnetLocBridgeEntry ::= SEQUENCE {
    s3EnetLocBridgeIndex
        INTEGER,
    s3EnetLocBridgeDescr
        DisplayString,
    s3EnetLocBridgePortCount
        INTEGER,
    s3EnetLocBridgeDiagSts
        OCTET STRING,
    s3EnetLocBridgeBootSts
        INTEGER,
    s3EnetLocBridgeStandbySts
        INTEGER
    }

s3EnetLocBridgeIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges between
                1 and 12.  The value for each board must remain constant
                at least from one re-initialization of the entity's
                network management system to the next re-initialization."
    ::= { s3EnetLocBridgeEntry 1 }

s3EnetLocBridgeDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Description of the local bridge board."
    ::= { s3EnetLocBridgeEntry 2 }

s3EnetLocBridgePortCount OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of ports that are on the local bridge board."
    ::= { s3EnetLocBridgeEntry 3 }

s3EnetLocBridgeDiagSts OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Latest Diagnostic LED Status that has been recorded."
    ::= { s3EnetLocBridgeEntry 4 }

s3EnetLocBridgeBootSts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            reqstToBoot(2),
            notReqstToBoot(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The current status of the board as it relates
                to rebooting."
    ::= { s3EnetLocBridgeEntry 5 }

s3EnetLocBridgeStandbySts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            standby(2),
            notStandby(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This status says whether the local bridge is active
                or in standby mode."
    ::= { s3EnetLocBridgeEntry 6 }

s3EnetLocBridgePortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetLocBridgePortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of Port entries that are part of a local
                bridge.  The number of entries is determined by knowing
                the number of local bridge boards that are installed
                by looking at s3ChassisSlotConfigTable and by knowing
                how many ports are on a local bridge board by looking at
                s3EnetLocBridgePortCount."
    ::= { s3000EnetLocBridge 2 }

s3EnetLocBridgePortEntry OBJECT-TYPE
    SYNTAX  S3EnetLocBridgePortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about the ports of the
                local bridges that are currently plugged into the
                3000 chassis."
    INDEX   { s3EnetLocBridgePortSlotIndex,
              s3EnetLocBridgePortIndex }
    ::= { s3EnetLocBridgePortTable 1 }

S3EnetLocBridgePortEntry ::= SEQUENCE {
    s3EnetLocBridgePortSlotIndex
        INTEGER,
    s3EnetLocBridgePortIndex
        INTEGER,
    s3EnetLocBridgePortMdaId
        INTEGER,
    s3EnetLocBridgePortIf
        INTEGER,
    s3EnetLocBridgePortDescr
        DisplayString,
    s3EnetLocBridgePortOpSts
        INTEGER
    }

s3EnetLocBridgePortSlotIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetLocBridgePortEntry 1 }

s3EnetLocBridgePortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each port.  Its value ranges
                between 1 and 12.  The value for each port must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetLocBridgePortEntry 2 }

s3EnetLocBridgePortMdaId OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Medium dependent ID for the port. See s3SlotModuleMdaId
                in the SynOptics Common MIB."
    ::= { s3EnetLocBridgePortEntry 3 }

s3EnetLocBridgePortIf OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            etherEther(2),
            etherTokenRing(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Bridge interface types."
    ::= { s3EnetLocBridgePortEntry 4 }

s3EnetLocBridgePortDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A text description of the port."
    ::= { s3EnetLocBridgePortEntry 5 }

s3EnetLocBridgePortOpSts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            standby(2),
            notStandby(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Operating status of the port."
    ::= { s3EnetLocBridgePortEntry 6 }

s3EnetRemBridgeSlotTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetRemBridgeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of Remote Bridge Board entries.  The number
                of entries is determined by the Concentrator Slot
                Configuration Table.  Only those entries that are
                Ethernet remote bridges will have entries in this list."
    ::= { s3000EnetRemBridge 1 }

s3EnetRemBridgeEntry OBJECT-TYPE
    SYNTAX  S3EnetRemBridgeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about Boards which are
                remote bridges that are currently plugged into the
                3000 chassis."
    INDEX   { s3EnetRemBridgeIndex }
    ::= { s3EnetRemBridgeSlotTable 1 }

S3EnetRemBridgeEntry ::= SEQUENCE {
    s3EnetRemBridgeIndex
        INTEGER,
    s3EnetRemBridgeDescr
        DisplayString,
    s3EnetRemBridgePortCount
        INTEGER,
    s3EnetRemBridgeDiagSts
        OCTET STRING,
    s3EnetRemBridgeBootSts
        INTEGER,
    s3EnetRemBridgeStandbySts
        INTEGER
    }

s3EnetRemBridgeIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetRemBridgeEntry 1 }

s3EnetRemBridgeDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Description of the board."
    ::= { s3EnetRemBridgeEntry 2 }

s3EnetRemBridgePortCount OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of ports that are on the board."
    ::= { s3EnetRemBridgeEntry 3 }

s3EnetRemBridgeDiagSts OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Latest Diagnostic LED Status that has been recorded."
    ::= { s3EnetRemBridgeEntry 4 }

s3EnetRemBridgeBootSts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            reqstToBoot(2),
            notReqstToBoot(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The current status of the board as it relates to rebooting."
    ::= { s3EnetRemBridgeEntry 5 }

s3EnetRemBridgeStandbySts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            standby(2),
            notStandby(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This status says whether the remote bridge is active
                or in standby mode."
    ::= { s3EnetRemBridgeEntry 6 }

s3EnetRemBridgePortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetRemBridgePortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of Port entries that are part of a remote
                bridge.  The number of entries is determined by
                knowing the number of remote bridge boards that are
                installed by looking at s3ChassisSlotConfigTable and
                by knowing how many ports are on a remote bridge
                board by looking at s3EnetRemBridgePortCount."
    ::= { s3000EnetRemBridge 2 }

s3EnetRemBridgePortEntry OBJECT-TYPE
    SYNTAX  S3EnetRemBridgePortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about the ports of the
                remote bridges that are currently plugged into the
                3000 chassis."
    INDEX   { s3EnetRemBridgePortSlotIndex,
              s3EnetRemBridgePortIndex }
    ::= { s3EnetRemBridgePortTable 1 }

S3EnetRemBridgePortEntry ::= SEQUENCE {
    s3EnetRemBridgePortSlotIndex
        INTEGER,
    s3EnetRemBridgePortIndex
        INTEGER,
    s3EnetRemBridgePortMdaId
        INTEGER,
    s3EnetRemBridgePortDescr
        DisplayString,
    s3EnetRemBridgePortOpSts
        INTEGER,
    s3EnetRemBridgePortRdySnd
        INTEGER,
    s3EnetRemBridgePortClrSnd
        INTEGER,
    s3EnetRemBridgePortCarDt
        INTEGER
    }

s3EnetRemBridgePortSlotIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetRemBridgePortEntry 1 }

s3EnetRemBridgePortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each port.  Its value ranges
                between 1 and 12.  The value for each port must
                remain constant at least from one re-initialization
                of the entity's network management system to the next
                re-initialization."
    ::= { s3EnetRemBridgePortEntry 2 }

s3EnetRemBridgePortMdaId OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ethernet(2),
            x21Barrier(3),
            x21Unbarrier(4),
            rs232(5),
            rs449(6),
            v35(7),
            g703(8),
            t1(9)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Medium dependent ID for the port."
    ::= { s3EnetRemBridgePortEntry 3 }

s3EnetRemBridgePortDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A text description of the port."
    ::= { s3EnetRemBridgePortEntry 4 }

s3EnetRemBridgePortOpSts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            standby(2),
            operational(3),
            noLink(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Operating status of the port."
    ::= { s3EnetRemBridgePortEntry 5 }

s3EnetRemBridgePortRdySnd OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            rdySnd(2),
            notRdySnd(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Ready to send status of the port."
    ::= { s3EnetRemBridgePortEntry 6 }

s3EnetRemBridgePortClrSnd OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            clrSnd(2),
            notClrSnd(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Clear to send status of the port."
    ::= { s3EnetRemBridgePortEntry 7 }

s3EnetRemBridgePortCarDt OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            carDt(2),
            noCarDt(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Carrier detect status of the port."
    ::= { s3EnetRemBridgePortEntry 8 }

s3EnetRouterSlotTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetRouterEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of Router Board entries.  The number of
                entries is determined by  the Concentrator Slot
                Configuration Table.  Only those entries that
                are Ethernet routers will have entries in this list."
    ::= { s3000EnetRouter 1 }

s3EnetRouterEntry OBJECT-TYPE
    SYNTAX  S3EnetRouterEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about Boards which
                are routers that are currently plugged into the
                3000 chassis."
    INDEX   { s3EnetRouterIndex }
    ::= { s3EnetRouterSlotTable 1 }

S3EnetRouterEntry ::= SEQUENCE {
    s3EnetRouterIndex
        INTEGER,
    s3EnetRouterDescr
        DisplayString,
    s3EnetRouterDiagSts
        OCTET STRING,
    s3EnetRouterStandbySts
        INTEGER
    }

s3EnetRouterIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetRouterEntry 1 }

s3EnetRouterDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(0..128))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Description of the router board."
    ::= { s3EnetRouterEntry 2 }

s3EnetRouterDiagSts OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Latest Diagnostic LED Status that has been recorded."
    ::= { s3EnetRouterEntry 3 }

s3EnetRouterStandbySts OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            standby(2),
            notStandby(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This status says whether the router is active or in
                standby mode."
    ::= { s3EnetRouterEntry 4 }

s3EnetCommonBoardTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetCommonBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Information maintained for each Ethernet board.  The
                information can be retrieved for any Ethernet board,
                even if the board is not on the same backplane Ethernet
                segment as this NMM.

                The instance is the slot number of the concentrator
                that the board occupies."
    ::= { s3000EnetBoard 5 }

s3EnetCommonBoardEntry OBJECT-TYPE
    SYNTAX  S3EnetCommonBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "There is one entry per Ethernet board in this table."
    INDEX   { s3EnetCommonBoardIndex }
    ::= { s3EnetCommonBoardTable 1 }

S3EnetCommonBoardEntry ::= SEQUENCE {
    s3EnetCommonBoardIndex
        INTEGER,
    s3EnetCommonBoardEnetAB
        INTEGER,
    s3EnetCommonBoardChanSwitch
        INTEGER,
    s3EnetCommonBoardRedund
        INTEGER
    }

s3EnetCommonBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12. The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetCommonBoardEntry 1 }

s3EnetCommonBoardEnetAB OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            enetA(2),
            enetB(3),
            enetAandEnetB(4)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "The channel to which the board is connected.  The
                primary use of this object is for providing realtime
                switching of boards between channel A and channel B.
                It is also returned in the enetChannelChange trap, in
                which case it indicates a board is switched from one
                channel to the other.  The write capability of this
                object can only apply to those modules with channel
                switching function.  Any attempt to write this object
                for a non-switchable board, the agent will return
                badValue."
    ::= { s3EnetCommonBoardEntry 2 }

s3EnetCommonBoardChanSwitch OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            switchCapable(2),
            notSwitchCapable(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent will return switchCapable(2) for any
                Ethernet host board which can be switched between
                Ethernet channels.  The value notSwitchCapable(3)
                indicates that the Ethernet board can not be switched
                to another channel."
    ::= { s3EnetCommonBoardEntry 3 }

s3EnetCommonBoardRedund OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            redundCapable(2),
            notRedundCapable(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The agent will return redundCapable(2) for any Ethernet
                host board which can provide hardware and/or software
                controlled redundancy on the port level.  The value
                notRedundCapable(3) indicates that the Ethernet board
                can not support port redundancy."
    ::= { s3EnetCommonBoardEntry 4 }

s3EnetPortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A list of port entries.  The number of entries is
                given by learning the type of board from the
                information in the s3ChassisSlotConfigTable."
    ::= { s3000EnetPort 1 }

s3EnetPortEntry OBJECT-TYPE
    SYNTAX  S3EnetPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about the Ports of
                each board plugged into the 3000 chassis which
                are on the same backplane Ethernet segment as
                the reporting NMM."
    INDEX   { s3EnetPortBoardIndex,
              s3EnetPortIndex }
    ::= { s3EnetPortTable 1 }

S3EnetPortEntry ::= SEQUENCE {
    s3EnetPortBoardIndex
        INTEGER,
    s3EnetPortIndex
        INTEGER,
    s3EnetPortLinkStatus
        INTEGER,
    s3EnetPortPartStatus
        INTEGER,
    s3EnetPortJabberStatus
        INTEGER,
    s3EnetPortFrmsRxOk
        Counter,
    s3EnetPortOctetsRxOk
        Counter,
    s3EnetPortMcastFrmsRxOk
        Counter,
    s3EnetPortBcastFrmsRxOk
        Counter,
    s3EnetPortColls
        Counter,
    s3EnetPortTooLongErrors
        Counter,
    s3EnetPortRuntErrors
        Counter,
    s3EnetPortAlignErrors
        Counter,
    s3EnetPortFcsErrors
        Counter,
    s3EnetPortLateCollErrors
        Counter,
    s3EnetPortAuthStatus
        INTEGER,
    s3EnetPortAuthAction
        INTEGER,
    s3EnetPortPartTime
        TimeTicks,
    s3EnetPortType
        INTEGER,
    s3EnetPortInterconStatus
        INTEGER,
    s3EnetPortAddrCollect
        INTEGER,
    s3EnetPortAddrLearnMode
        INTEGER,
    s3EnetPortTxSecurity
        INTEGER
    }

s3EnetPortBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one reinitialization
                of the entity's network management system to the
                next reinitialization."
    ::= { s3EnetPortEntry 1 }

s3EnetPortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each port.  Its value is dependent
                on the board type.  The value for each port must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetPortEntry 2 }

s3EnetPortLinkStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            off(1),
            on(2),
            other(3)
            }
    ACCESS  read-only
    STATUS  deprecated
    DESCRIPTION
                "Tells whether the port is receiving link status."
    ::= { s3EnetPortEntry 3 }

s3EnetPortPartStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            partition(2),
            autoPartition(3),
            timedPartition(4),
            latSecPartition(5)
            }
    ACCESS  read-write
    STATUS  deprecated
    DESCRIPTION
                "This indicates the operational status of the Port.
                Writing a partition(2) will partition the port
                indefinitely and enabled(1) will enable the port.

                If a timed partition is desired, then writing
                timedPartition(4) to this object at the same time
                that a time value is supplied in s3EnetPortPartTime
                is required. Timed partitions will not survive across
                a reset. In this case the port will go to the
                partition(2) state.

                The value latSecPartition(5) is returned when the port
                has been automatically partitioned by the LattisSecure
                Host Module because of a security violation.  The value
                autoPartition(3) is returned when the port has been
                automatically partitioned by the repeater using the
                802.3 repeater auto-partition function.

                The agent will not allow this object to be set to
                autoPartition(3) or latSecPartition(5) using an
                SNMP request."
    ::= { s3EnetPortEntry 4 }

s3EnetPortJabberStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            ok(1),
            jabbering(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Tells whether the DTE connected to the Port is
                jabbering or not."
    ::= { s3EnetPortEntry 5 }

s3EnetPortFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the port.  This does not include frames
                received with a frame-too-long, runt, FCS, or alignment
                errors.  This counter includes broadcast and multicast
                frames that are received."
    ::= { s3EnetPortEntry 6 }

s3EnetPortOctetsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Contains a count of data and padding octets in frames
                that are successfully received by the port.  This does
                not include frames received with a frame-too-long, runt,
                FCS, or alignment errors.

                This counter includes octets in broadcast and multicast
                frames that are received.

                This counter does not include the octets in the
                CRC field. The octets in the address and length/type
                fields are counted."
    ::= { s3EnetPortEntry 7 }

s3EnetPortMcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the port and are directed to an active
                non-broadcast group address.  This does not include
                frames received with a frame-too-long, runt, FCS, or
                alignment errors.

                Only frames that are for a multicast address that this
                interface is receiving are counted. Broadcast packets
                are not included."
    ::= { s3EnetPortEntry 8 }

s3EnetPortBcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are successfully
                received by the port and are directed to the broadcast
                group address.  This does not include frames received
                with a frame-too-long, runt, FCS, or alignment errors.

                Multicast packets are not included."
    ::= { s3EnetPortEntry 9 }

s3EnetPortColls OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of collisions. For NMM+ this is a
                true counter.  For other NMMs this is a count of the
                collision flags."
    ::= { s3EnetPortEntry 10 }

s3EnetPortTooLongErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames that are received by
                the port and exceed the maximum permitted frame size.
                This counter is incremented when the frameTooLong
                error is detected."
    ::= { s3EnetPortEntry 11 }

s3EnetPortRuntErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the port
                that are less than the minimum permitted frame size and
                have a good FCS."
    ::= { s3EnetPortEntry 12 }

s3EnetPortAlignErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received by the port
                that are not an integral number of octets in length and
                do not pass the FCS check.  This counter is incremented
                when the alignmentError status is detected."
    ::= { s3EnetPortEntry 13 }

s3EnetPortFcsErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of frames received the port
                that are an integral number of octets in length that
                do not pass the FCS check.  This counter is incremented
                when the frameCheckError status is detected."
    ::= { s3EnetPortEntry 14 }

s3EnetPortLateCollErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of late collisions. For NMM+
                this is a true counter.  For other NMMs this is a count
                of the late collision flags."
    ::= { s3EnetPortEntry 15 }

s3EnetPortAuthStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This object is only used if s3EnetConcSecureStatus
                is set to portCheckOn(3) or if the port is on a
                LattisSecure Host Module.

                In this case, turning this object on(2) means that
                any node that heard on this port which is not allowed
                on this port will cause the action specified in
                s3EnetPortAuthAction to take place.

                This object does not affect the LattisSecure transmit
                security feature for the port.  It is incompatible with
                LattisSecure continuous learning mode.  If the value of
                s3EnetPortAddrLearnMode for a LattisSecure port is
                continuousLearn(3), turning this object to on(2) for
                that port will not have any affect.

                If s3EnetConcSecureStatus is set to portCheckOn(3) but
                this object is set to off(3), then all authorized nodes
                or LattisSecure receive security features for this port
                are deactivated.

                If s3EnetConcSecureStatus is not set to portCheckOn(3),
                then this object will not be used for allowed nodes,
                but will be used for LattisSecure."
    ::= { s3EnetPortEntry 16 }

s3EnetPortAuthAction OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            noAction(2),
            sendTrap(3),
            partition(4),
            sendTrapPartition(5)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "If s3EnetConcSecureStatus is portCheckOn(3) or this
                port is on a LattisSecure Host Module, and
                s3EnetPortAuthStatus is on(2) and an authorized nodes
                violation occurs on this port, then the action specified
                by this object will take place on this port.

                If the port is a LattisSecure port, the authorized
                nodes security will be implemented by the LattisSecure
                Host Module."
    ::= { s3EnetPortEntry 17 }

s3EnetPortPartTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  deprecated
    DESCRIPTION
                "When partitioning the port for a specified time,
                s3EnetPortPartStatus must be set with timedpartition(4)
                and this object must be supplied with the duration
                value.  If a PDU sets s3EnetPortPartStatus and not
                this object, the port will not be partitioned."
    ::= { s3EnetPortEntry 18 }

s3EnetPortType OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            tenBaseT(2),
            tenBaseTMdi(3),
            aui(4),
            bnc(5),
            foirl(6),
            tenBaseFL(7),
            switch(8),
            switchMdi(9),
            tenBaseFLRedund(10)
            }
    ACCESS  read-only
    STATUS  deprecated
    DESCRIPTION
                "The media connection type for this port.

                Note that this object was called s3EnetPortMDIXSwitch
                in the Ethernet 3.3 and 4.0 MIBs."
    ::= { s3EnetPortEntry 19 }

s3EnetPortInterconStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            interconnect(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object tells whether the port is connected to a
                host or to an interconnect (defined to be another NMM
                that is sending hello messages).

                The NMM agent will assign this object the value other(1)
                on initialization.  If it sees hello messages coming in
                on the port, it will change the InterconStatus to be
                interconnect(2)."
    ::= { s3EnetPortEntry 20 }

s3EnetPortAddrCollect OBJECT-TYPE
    SYNTAX  INTEGER {
            default(1),
            neverCollect(2),
            alwaysCollect(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This object tells whether the NMM should collect
                node address information from this port for the Find
                Nodes, Show Nodes, and Traffic Matrix (NMM+ only)
                tables.

                By default, the node addresses are collected only
                from ports that are not identified as interconnect
                ports.  In addition, allowed nodes checking is
                done only on ports that are not interconnect ports.
                This object provides a means of overriding the default
                for collection and checking of node addresses.

                Setting this variable to default(1) tells the NMM to
                collect and check addresses if and only the port has
                not been identified as an interconnect port.

                To disable node address collection and checking on a
                port, set this object to neverCollect(2).

                To collect and check node addresses for an interconnect
                port, set this object to alwaysCollect(3).

                This object and its default setting has no affect
                on LattisSecure receive or transmit security features.

                To restore the 'natural' value for the port, set this
                object to default(1)."
    ::= { s3EnetPortEntry 21 }

s3EnetPortAddrLearnMode OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            noAutoLearn(2),
            continuousLearn(3),
            oneShotLearn(4)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This object indicates whether the port should
                automatically learn the port address by reading the
                source address on the incoming packets.  This object
                applies only to ports on a LattisSecure Host Module.
                For other ports, the agent  returns the value other.

                A Get will return the current learning mode of the port.

                Setting to noAutoLearn(2) can be used to turn off
                continuousLearn (3) or oneShotLearn(4).

                The value of this object is in effect regardless of the
                value of s3EnetConcSecureStatus or s3EnetPortAuthStatus.

                Continuous learning is not compatible with LattisSecure
                receive security, thus s3EnetPortAddrLearnMode should not
                be set to continuousLearn(3) when s3EnetPortAuthStatus
                is on(2).  If this combination is set, the receive
                security will not function.

                If this object is set to oneShotLearn(4), the agent will
                store the address (when it is learned) into the allowed
                nodes tables.  This can cause the current address to be
                written over.

                Because continuous learning is not compatible with
                receive security, addresses learned while the port
                is in continuous learning mode will not be stored in
                the allowed nodes tables.

                Attempts to set the value to other(1) on a LattisSecure
                port will be rejected by the agent.  Likewise, attempts
                to set the value to noAutoLearn(2), continuousLearn(3),
                or oneShotLearn(4) on a non-LattisSecure port will be
                rejected."
    ::= { s3EnetPortEntry 22 }

s3EnetPortTxSecurity OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This value of this object is meaningful only when
                s3EnetConcSecureStatus is not set to concSecureOff(5)
                (i.e., if security features are activated on the
                concentrator).

                This object applies only to ports on LattisSecure Host
                Modules.  For other ports, the agent will return other(1)
                in response to a get request.

                The value off(3) indicates that LattisSecure transmit
                security is disabled on this LattisSecure port.  The
                value on(2) indicates that LattisSecure transmit security
                is enabled on this LattisSecure port.

                Attempts to set the value to other(1) on a LattisSecure
                port will be rejected by the agent.  Likewise, attempts
                to set the value to on(2) or off(3) on a non-LattisSecure
                port will be rejected."
    ::= { s3EnetPortEntry 23 }

s3EnetCommonPortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetCommonPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "This table provides a list of port entries.  The
                number of entries is given for any Ethernet board
                in the concentrator, even if the board is not on the
                same Ethernet segment as this NMM."
    ::= { s3000EnetPort 2 }

s3EnetCommonPortEntry OBJECT-TYPE
    SYNTAX  S3EnetCommonPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing objects about the ports of each
                Ethernet board plugged into the 3000-series chassis."
    INDEX   { s3EnetCommonPortBoardIndex,
              s3EnetCommonPortIndex }
    ::= { s3EnetCommonPortTable 1 }

S3EnetCommonPortEntry ::= SEQUENCE {
    s3EnetCommonPortBoardIndex
        INTEGER,
    s3EnetCommonPortIndex
        INTEGER,
    s3EnetCommonPortLinkStatus
        INTEGER,
    s3EnetCommonPortPartStatus
        INTEGER,
    s3EnetCommonPortType
        INTEGER,
    s3EnetCommonPortPartTime
        TimeTicks
    }

s3EnetCommonPortBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization."
    ::= { s3EnetCommonPortEntry 1 }

s3EnetCommonPortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each port.  Its value is dependent
                on the board type."
    ::= { s3EnetCommonPortEntry 2 }

s3EnetCommonPortLinkStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            off(1),
            on(2),
            other(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Tells whether the port is receiving link status."
    ::= { s3EnetCommonPortEntry 3 }

s3EnetCommonPortPartStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            partition(2),
            autoPartition(3),
            timedPartition(4),
            latSecPartition(5)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This indicates the operational status of the Port.
                Writing a partition(2) will partition the port
                indefinitely and enabled(1) will enable the port.

                If a timed partition is desired, then writing
                timedPartition(4) to this object at the same time
                that a time value is supplied in s3EnetCommonPortPartTime
                is required.  Timed partitions will not survive across
                a reset.  In this case the port will go to the
                partition(2) state.

                The value latSecPartition(5) is returned when the port
                has been automatically partitioned by the LattisSecure
                Host Module because of a security violation.  The value
                autoPartition(3) is returned when the port has been
                automatically partitioned by the repeater using the
                802.3 repeater auto-partition function.

                The agent will not allow this object to be set to
                autoPartition(3) or latSecPartition(5) using an SNMP
                request.

                Note that the value timedPartition(4)  is returned only
                when the board is timed partitioned by this NMM."
    ::= { s3EnetCommonPortEntry 4 }

s3EnetCommonPortType OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            tenBaseT(2),
            tenBaseTMdi(3),
            aui(4),
            bnc(5),
            foirl(6),
            tenBaseFL(7),
            switch(8),
            switchMdi(9),
            tenBaseFLRedund(10)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The media connnection type for this port.

                Note that this object was called s3EnetPortMDIXSwitch
                in the Ethernet 3.3 and 4.0 MIBs."
    ::= { s3EnetCommonPortEntry 5 }

s3EnetCommonPortPartTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "When partitioning the port for a specified time,
                s3EnetCommonPortPartStatus must be set with
                timedPartition(4) and this object must be supplied
                with the duration value.  If a PDU sets
                s3EnetCommonPortPartStatus and not this object,
                the port will not be partitioned."
    ::= { s3EnetCommonPortEntry 6 }

s3EnetRedPortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetRedPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table of ports for each 10BASE-FL board with
                redundancy capability.  The number of boards is
                determined by checking s3EnetCommonBoardRedund having
                a value of redundCapable(2) for each board in table
                s3EnetCommonBoardTable."
    ::= { s3000EnetPort 3 }

s3EnetRedPortEntry OBJECT-TYPE
    SYNTAX  S3EnetRedPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "An entry in the table of ports on boards with
                redundancy capability."
    INDEX   { s3EnetRedPortBoardIndex,
              s3EnetRedPortIndex }
    ::= { s3EnetRedPortTable 1 }

S3EnetRedPortEntry ::= SEQUENCE {
    s3EnetRedPortBoardIndex
        INTEGER,
    s3EnetRedPortIndex
        INTEGER,
    s3EnetRedPortRedundMode
        INTEGER,
    s3EnetRedPortOperStatus
        INTEGER,
    s3EnetRedPortRemoteOperStatus
        INTEGER,
    s3EnetRedPortCompanionSlotNo
        INTEGER,
    s3EnetRedPortCompanionPortNo
        INTEGER
    }

s3EnetRedPortBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The index of the slot containing the board.  The value
                for each board must remain constant at least from one
                re-initialization of the entity's network management
                system to the next re-initialization."
    ::= { s3EnetRedPortEntry 1 }

s3EnetRedPortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The index of the port on the module."
    ::= { s3EnetRedPortEntry 2 }

s3EnetRedPortRedundMode OBJECT-TYPE
    SYNTAX  INTEGER {
            standAlone(1),
            hwActive(2),
            hwStandby(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object indicates the port's redundancy mode. A value
                of standAlone(1) indicates that the port is not set for
                hardware redundancy. A value of hwActive(2) indicates that
                the port is the active one of a hardware redundant pair.
                A value of hwStandby(3) indicates that the port is the
                standby one of a hardware redundant pair"
    ::= { s3EnetRedPortEntry 3 }

s3EnetRedPortOperStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ok(2),
            localFault(3),
            remoteFault(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object indicates port's redundancy status.  This
                value is valid only when the redundant mode is not
                standAlone(1).  The values are:
                  other(1).........none of the following
                  ok(2)............no fault
                  localFault(3)....the port had a Local Fault condition
                  remoteFault(4)...the port is receiving Remote Fault signal

                Either a localFault(3) or remoteFault(4) condition should
                cause a redundant port pair to switchover."
    ::= { s3EnetRedPortEntry 4 }

s3EnetRedPortRemoteOperStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            snpxFLRemFltCpblPortUp(1),
            snpxFLFBRemFltCpblPortUp(2),
            tenBaseFLPortUp(3),
            tenBaseFBPortUp(4),
            snpxRemFltCpblPortFault(5),
            tenBaseFBPortFault(6),
            unknown(7)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This object reflects the real time status of the
                received data from the remote port.

                A value of snpxFLRemFltCpblPortUp(1) indicates that
                the remote port is capable of 10BASE-FL signaling, as
                well as SynOptics proprietary remote fault signaling.
                A remote fault on such a port is indicated by
                snpxRemFltCpblPortFault(5).

                A value of snpxFLFBRemFltCpblPortUp(2) indicates that
                the remote port is capable of 10BASE-FL, 10BASE-FB and
                SynOptics proprietary remote fault signaling.  A remote
                fault on such a port is indicated by
                snpxRemFltCpblPortFault(5).

                A value of tenBaseFLPortUp(3) indicates that the remote
                port uses regular idle 10BASE-FL signaling, and is
                incapable of remote fault signaling.

                A value of tenBaseFBPortUp(4) indicates that the remote
                port uses 10BASE-FB synchronous signaling.  A remote
                fault on such a port is indicated by
                tenBaseFBPortFault(6).

                A value of unknown(7) indicates that the remote signal
                received is none of the above."
    ::= { s3EnetRedPortEntry 5 }

s3EnetRedPortCompanionSlotNo OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The slot number of the other port which is in the
                redundant pair.  In the case of a standalone port,
                a value of 0 will be returned."
    ::= { s3EnetRedPortEntry 6 }

s3EnetRedPortCompanionPortNo OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The port number of the other port which is in the
                redundant pair.  In the case of a standalone port,
                a value of 0 will be returned."
    ::= { s3EnetRedPortEntry 7 }

s3EnetPlusPortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetPlusPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "This table provides a list of entries, each entry
                providing information related to frame MAC level
                error conditions per port. This table is conceptually
                an extension to the s3EnetPortTable and is
                only implemented by the 3313S and 3314S NMMs."
    ::= { s3000EnetPlusStatistics 1 }

s3EnetPlusPortEntry OBJECT-TYPE
    SYNTAX  S3EnetPlusPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "An entry in the Plus Port table."
    INDEX   { s3EnetPlusPortBoardIndex,
              s3EnetPlusPortIndex }
    ::= { s3EnetPlusPortTable 1 }

S3EnetPlusPortEntry ::= SEQUENCE {
    s3EnetPlusPortBoardIndex
        INTEGER,
    s3EnetPlusPortIndex
        INTEGER,
    s3EnetPortFragments
        Counter,
    s3EnetPortShortEvents
        Counter,
    s3EnetPortAutoPartitions
        Counter,
    s3EnetPortRateMismatches
        Counter,
    s3EnetPortJabbers
        Counter,
    s3EnetPortLastSrcAddr
        PhysAddress,
    s3EnetPortSrcAddrChanges
        Counter
    }

s3EnetPlusPortBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges between
                1 and 12.  (This is the slot number.)"
    ::= { s3EnetPlusPortEntry 1 }

s3EnetPlusPortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each port.  Its value typically ranges
                between 1 and 12."
    ::= { s3EnetPlusPortEntry 2 }

s3EnetPortFragments OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of fragments received by the
                board between 80-512 bits (64 bytes), inclusively,
                with invalid FCS or alignment errors.  (These
                commonly represent collision fragments, and are
                not errors.  Collision fragments were called
                FragErrors in the rev 3.x MIB, and were counted
                only on a per-board basis.)"
    ::= { s3EnetPlusPortEntry 3 }

s3EnetPortShortEvents OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of fragments received by the
                port shorter than 80 bits."
    ::= { s3EnetPlusPortEntry 4 }

s3EnetPortAutoPartitions OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of times the ports on the board
                have autopartitioned due to excessive collisions (more
                than 32 consecutive collisions).  This count is an
                approximation and may be less than the total count."
    ::= { s3EnetPlusPortEntry 5 }

s3EnetPortRateMismatches OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the occurrences of out of
                spec bit rates.  This indicates the number of times
                FIFO buffer over-runs or underruns due to transmission
                rate errors."
    ::= { s3EnetPlusPortEntry 6 }

s3EnetPortJabbers OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the times that MAU jabber
                lockup protection (MJLP) was invoked because transmission
                of data from this port exceeded 5 msec in duration.
                This information can be useful in identifying faulty
                stations."
    ::= { s3EnetPlusPortEntry 7 }

s3EnetPortLastSrcAddr OBJECT-TYPE
    SYNTAX  PhysAddress (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This is the source address of the last packet
                received through this port."
    ::= { s3EnetPlusPortEntry 8 }

s3EnetPortSrcAddrChanges OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This is the number of times that the
                s3EnetPortLastSrcAddr object for this has changed."
    ::= { s3EnetPlusPortEntry 9 }

s3EnetPlusBoardTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3EnetPlusBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "This table provides a list of entries, each entry
                providing information related to frame MAC level
                error conditions per board.  This table is conceptually
                an extension to the s3EnetboardTable and is
                only implemented by the 3313S and 3314S NMMs."
    ::= { s3000EnetPlusStatistics 2 }

s3EnetPlusBoardEntry OBJECT-TYPE
    SYNTAX  S3EnetPlusBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "An entry in the Plus Board table."
    INDEX   { s3EnetPlusBoardIndex }
    ::= { s3EnetPlusBoardTable 1 }

S3EnetPlusBoardEntry ::= SEQUENCE {
    s3EnetPlusBoardIndex
        INTEGER,
    s3EnetBoardFragments
        Counter,
    s3EnetBoardShortEvents
        Counter,
    s3EnetBoardAutoPartitions
        Counter,
    s3EnetBoardRateMismatches
        Counter,
    s3EnetBoardJabbers
        Counter
    }

s3EnetPlusBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The board number part of an index."
    ::= { s3EnetPlusBoardEntry 1 }

s3EnetBoardFragments OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of fragments received by the
                board between 80-512 bits (64 bytes), inclusively,
                with invalid FCS or alignment errors.  (These
                commonly represent collision fragments, and are
                not errors.  Collision fragments were called
                FragErrors in the rev 3.x MIB, and were counted
                only on a per-concentrator basis.)"
    ::= { s3EnetPlusBoardEntry 2 }

s3EnetBoardShortEvents OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of fragments received by
                the board shorter than 80 bits."
    ::= { s3EnetPlusBoardEntry 3 }

s3EnetBoardAutoPartitions OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of times the ports on this
                board have been autopartitioned due to excessive
                collisions (more than 32 consecutive collisions).
                This count is an approximation and may be less than
                the total count."
    ::= { s3EnetPlusBoardEntry 4 }

s3EnetBoardRateMismatches OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the occurrences of out of
                spec bit rates.  This indicates the number of times
                FIFO buffer over-runs or underruns due to
                transmission rate errors."
    ::= { s3EnetPlusBoardEntry 5 }

s3EnetBoardJabbers OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the times that MAU jabber
                lockup protection (MJLP) was invoked because
                transmission of data from a port on this board
                exceeded 5 msec in duration.  This information can
                be useful in identifying faulty stations."
    ::= { s3EnetPlusBoardEntry 6 }

s3EnetConcShortEvents OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of fragments received by
                the concentrator shorter than 80 bits."
    ::= { s3000EnetPlusConc 1 }

s3EnetConcAutoPartitions OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of times the ports on this
                concentrator have been autopartitioned due to
                excessive collisions (more than 32 consecutive
                collisions).  This count is based on a one-bit
                counter (flag) per port in the host modules, and
                will not always represent the total count."
    ::= { s3000EnetPlusConc 2 }

s3EnetConcRateMismatches OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the occurrences of out
                of spec bit rates.  This indicates the number of
                times FIFO buffer over-runs or underruns due to
                transmission rate errors."
    ::= { s3000EnetPlusConc 3 }

s3EnetConcJabbers OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a count of the times that MAU jabber
                lockup protection (MJLP) was invoked because
                transmission of data from a port on this
                concentrator exceeded 5 msec in duration.
                This information can be useful in identifying
                faulty stations."
    ::= { s3000EnetPlusConc 4 }

s3EnetConcCollBackoffErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains a total concentrator count of the
                collision events that occur during the normal
                collision window (i.e., the collisions is not
                a late collision) and do not have a runt error."
    ::= { s3000EnetPlusConc 5 }

s3TrCommonBoardTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3TrCommonBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Information maintained for each token ring board.
                The information can be retrieved for any token
                ring board, even if the board is not on the 
                same backplane ring as this NMM.

                The instance is the slot number of the concentrator
                that the board occupies."
    ::= { s3000TrBoard 2 }

s3TrCommonBoardEntry OBJECT-TYPE
    SYNTAX  S3TrCommonBoardEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "There is one entry per board in this table."
    INDEX   { s3TrCommonBoardIndex }
    ::= { s3TrCommonBoardTable 1 }

S3TrCommonBoardEntry ::= SEQUENCE {
    s3TrCommonBoardIndex
        INTEGER,
    s3TrCommonBoardRing1or2
        INTEGER,
    s3TrCommonBoardRingSpeed
        INTEGER
    }

s3TrCommonBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization.

                If a board is inserted or reinserted in a concentrator
                then the NMM has to be reinitialized."
    ::= { s3TrCommonBoardEntry 1 }

s3TrCommonBoardRing1or2 OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ring1(2),
            ring2(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Determines which ring the board is currently using
                on the concentrator backplane."
    ::= { s3TrCommonBoardEntry 2 }

s3TrCommonBoardRingSpeed OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            speed1M(2),
            speed4M(3),
            speed16M(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Token Ring speed of the ring that this board is
                connected to."
    ::= { s3TrCommonBoardEntry 3 }

s3TrPortTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3TrPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing information about each port
                of a LattisNet concentrator.  The number of entries
                is given by knowing the number of occupied slots
                in s3ChassisSlotConfigTable whose s3SlotModuleType
                is of a token ring type and is on the same backplane
                ring as the agent NMM."
    ::= { s3000TrPort 1 }

s3TrPortEntry OBJECT-TYPE
    SYNTAX  S3TrPortEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A port entry containing objects at the port level
                for a particular port."
    INDEX   { s3TrPortBoardIndex,
              s3TrPortIndex }
    ::= { s3TrPortTable 1 }

S3TrPortEntry ::= SEQUENCE {
    s3TrPortBoardIndex
        INTEGER,
    s3TrPortIndex
        INTEGER,
    s3TrPortWrap
        INTEGER,
    s3TrPortTestLatch
        INTEGER,
    s3TrPortRelayStatus
        INTEGER,
    s3TrPortPhantomStatus
        INTEGER,
    s3TrPortPhantomChangeFlag
        INTEGER,
    s3TrPortChgSyn2IBM
        INTEGER,
    s3TrPortStrap
        INTEGER
    }

s3TrPortBoardIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each board.  Its value ranges
                between 1 and 12.  The value for each board must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization.

                If a board is inserted or reinserted in a concentrator
                then the NMM has to be reinitialized."
    ::= { s3TrPortEntry 1 }

s3TrPortIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A unique value for each port.  Its value ranges
                between 1 and 12.  The value for each port must
                remain constant at least from one re-initialization
                of the entity's network management system to the
                next re-initialization.  If the board is an NMM
                board it will only have 2 ports, with Port 1 being
                for Ring In and Port 2 being for Ring Out."
    ::= { s3TrPortEntry 2 }

s3TrPortWrap OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            wrap(2),
            connect(3),
            timedWrap(4),
            beaconWrap(5),
            wrongSpeedWrap(6),
            permBeaconWrap(7),
            securityViolationWrap(8)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Status of the port. Setting wrap(2) disconnects
                the port from the ring and setting this object to
                connect(3) connects the port to the ring.  If a
                timed wrap is desired, then writing timedWrap(4)
                to this object at the same time that a time value
                is supplied in s3TrPortPartTime is required.
                Timed wraps will not survive across a reset.  In
                this case the port will go to the wrap(2) state.
                BeaconWrap(5) indicates that the port is temporary
                wrapped by the agent due to the station of the
                port which was beaconing. The wrapped port will
                be unwrapped by the agent when the station is
                deinserted from the ring.  WrongSpeedWrap(6)
                indicates that the port is wrapped by the host
                module. This is due to the wrong speed of a new
                station which was inserted to the ring.
                PermBeaconWrap(7) indicates that the port is
                wrapped by the agent permanently. This is caused
                by the beaconing station of the port attempting
                to deinsert/insert to the ring for more than
                2 times within 1 minute. The wrapped port will
                not be unwrapped by the agent. SecurityViolationWrap(8)
                indicates that the port is wrapped by the agent due to
                the station not being allowed to insert in the port.
                The values beaconWrap(5), wrongSpeedWap(6),
                permanentBeaconwrap(7) and securityViolationWrap(8)
                can not be written.

                Note: The securityViolationWrap feature is implemented
                      only in version 4.3 and subsequent agents."
    ::= { s3TrPortEntry 3 }

s3TrPortTestLatch OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Status of the test latch which is used to set
                the channel decoder used to monitor the health
                of the communication path between the NMM and
                the module channel."
    ::= { s3TrPortEntry 4 }

s3TrPortRelayStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Status of the channel's present relay mode.
                On(2) means the channel is in the ring and off(3)
                means the channel is bypassed."
    ::= { s3TrPortEntry 5 }

s3TrPortPhantomStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            on(2),
            off(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Status of the ring access request signal."
    ::= { s3TrPortEntry 6 }

s3TrPortPhantomChangeFlag OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            noChange(2),
            change(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Change(3) indicates that port phantom has been
                changed from OFF to ON.  After inquiry by NMS, it
                will be cleared to noChange(2).  Port phantom
                changing from ON to OFF has no impact on this object."
    ::= { s3TrPortEntry 7 }

s3TrPortChgSyn2IBM OBJECT-TYPE
    SYNTAX  INTEGER {
            notSupported(1),
            synoptics(2),
            ibm(3)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "If the port is on a ring in/ring out module this
                object changes the strap state depending on the
                jumper setting retrieved as s3TrPortStrap.  If the
                strap is set for SynOptics phantom option, this
                object can be changed to ibm(3).  If the strap is
                set for non-SynOptics option, this object can not
                be changed.

                Non ring in/ring out modules or fiber
                ring in/ring out modules must take on the value
                of notSupported(1)."
    ::= { s3TrPortEntry 8 }

s3TrPortStrap OBJECT-TYPE
    SYNTAX  INTEGER {
            notSupported(1),
            synoptics(2),
            ibm(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "If the port is on a ring in/ring out module this
                object signifies whether the hardware jumper is in
                synoptics(2) mode or ibm(3) mode.  This information
                is retrieved using a  NMI command.

                For ports on fiber ring in/ring out modules, and those
                ports not on ring in/ring out modules, the agent
                always returns notSupported(1)."
    ::= { s3TrPortEntry 9 }

s3TrNmmFnNum OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Defines the flat network number that this NMM
                is part of."
    ::= { s3000TrNmm 1 }

s3TrNmmRingNum OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Defines the segment number that this NMM
                is connected to.

                ***ACCESS VARIATION - changed access from read-only"
    ::= { s3000TrNmm 2 }

s3TrNmmSlotNum OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  deprecated
    DESCRIPTION
                "Defines the slot number that this NMM is
                connected to.  New NMS implementations should
                use the object s3AgentMySlotId defined in the
                common MIB.  This object will be deleted from
                a future version of the Token Ring MIB."
    ::= { s3000TrNmm 3 }

s3TrNmmFpuIdRev OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The revision of the Front-end Frame Processing
                unit.  0=Rev. A, 1=Rev. B, etc."
    ::= { s3000TrNmm 4 }

s3TrNmmFpuStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            notPresent(1),
            notOperational(2),
            operational(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The status of the Front-end Frame Processing Unit."
    ::= { s3000TrNmm 5 }

s3TrNmmDramSize OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            k512(2),
            oneMeg(3),
            twoMeg(4),
            threeMeg(5),
            fourMeg(6),
            fiveMeg(7),
            sixMeg(8),
            sevenMeg(9),
            eightMeg(10),
            nineMeg(11),
            tenMeg(12),
            elevenMeg(13),
            twelveMeg(14),
            thirteenMeg(15),
            fourteenMeg(16),
            fifteenMeg(17),
            sixteenMeg(18)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The highest address of the DRAM in the NMM memory map.
                The possible values are:
                  other(1).........Unknown size
                  k512(2)..........512K memory
                  oneMeg(3)........1M memory
                         .
                         .
                         .
                  sixteenMeg(18)...16M memory"
    ::= { s3000TrNmm 6 }

s3TrNmmEepromSize OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            size2kBytes(2),
            size8kBytes(3),
            size16kBytes(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of the EEPROM in the NMM memory map.
                The possible values are:
                  other(1)..........Unknown size
                  size2kBytes(4)....2K by 8
                  size8kBytes(4)....8K by 8
                  size16kBytes(4)...16K by 8"
    ::= { s3000TrNmm 7 }

s3TrNmmGrpAddrFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of Group Address frames received without
                error by this NMM.

                Note:  The NMM counts only Group Address frames
                that are addressed to its own Group Address(es)."
    ::= { s3000TrNmm 8 }

s3TrNmmRing1or2 OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            ring1(2),
            ring2(3)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Determines which ring the NMM is currently using
                on the concentrator backplane."
    ::= { s3000TrNmm 9 }

s3TrNmmRingSpeed OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            speed1M(2),
            speed4M(3),
            speed16M(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Token Ring speed."
    ::= { s3000TrNmm 10 }

s3TrNmmHexDisplay OBJECT-TYPE
    SYNTAX  DisplayString (SIZE(4))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "4 octet hex display string that is displayed
                on the NMM control panel."
    ::= { s3000TrNmm 11 }

s3TrNmmEpromSize OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            k2kby8(2),
            k8kby8(3),
            k16kby8(4),
            k32kby8(5),
            k64kby8(6),
            k128kby8(7),
            k256kby8(8)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The size of the EPROM in the NMM memory map."
    ::= { s3000TrNmm 12 }

s3TrNodeTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF S3TrNodeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Table containing station specific information."
    ::= { s3000TrNode 1 }

s3TrNodeEntry OBJECT-TYPE
    SYNTAX  S3TrNodeEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Entry in the table containing counters and
                profiling information for each node detected on
                the local token ring."
    INDEX   { s3TrNodeEntMacAddress }
    ::= { s3TrNodeTable 1 }

S3TrNodeEntry ::= SEQUENCE {
    s3TrNodeEntMacAddress
        PhysAddress,
    s3TrNodeEntStatus
        INTEGER,
    s3TrNodeEntNodeStatus
        OCTET STRING,
    s3TrNodeLineErrs
        Counter,
    s3TrNodeBurstErrs
        Counter,
    s3TrNodeAriFciErrs
        Counter,
    s3TrNodeLostFrames
        Counter,
    s3TrNodeRcvCongestErrs
        Counter,
    s3TrNodeFrmCopyErrs
        Counter,
    s3TrNodeTokenErrs
        Counter,
    s3TrNodeInternalErrs
        Counter,
    s3TrNodeAbortTransErrs
        Counter,
    s3TrNodeFrequencyErrs
        Counter,
    s3TrNodeEntProductId
        OCTET STRING,
    s3TrNodeEntUna
        OCTET STRING,
    s3TrNodeEntNodeVersion
        OCTET STRING,
    s3TrNodeEntPhysDrop
        OCTET STRING,
    s3TrNodeEntFuncAddr
        OCTET STRING,
    s3TrNodeEntAuthFuncClass
        OCTET STRING,
    s3TrNodeEntAuthAccPriority
        OCTET STRING,
    s3TrNodeEntGrpAddr
        OCTET STRING,
    s3TrNodeEntStationId
        OCTET STRING,
    s3TrNodeEntBeaconType
        INTEGER,
    s3TrNodeBeaconCnt
        Counter,
    s3TrNodeLastBeaconTime
        TimeTicks,
    s3TrNodeLastInsertTime
        TimeTicks,
    s3TrNodeFirstInsertTime
        TimeTicks,
    s3TrNodeLastDeinsertTime
        TimeTicks,
    s3TrNodeRemoveStation
        INTEGER
    }

s3TrNodeEntMacAddress OBJECT-TYPE
    SYNTAX  PhysAddress (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "MAC address of node that this entry in the
                table is for."
    ::= { s3TrNodeEntry 1 }

s3TrNodeEntStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            beaconing(1),
            notBeaconing(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Tells whether the station is currently
                beaconing or not."
    ::= { s3TrNodeEntry 4 }

s3TrNodeEntNodeStatus OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Node status as defined in 802.5 specification
                (section 3.3.2.18)."
    ::= { s3TrNodeEntry 5 }

s3TrNodeLineErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of line errors.  Section 3.8.1 of
                IEEE 802.5 specification."
    ::= { s3TrNodeEntry 6 }

s3TrNodeBurstErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of burst errors.  Section 3.8.3 of
                IEEE 802.5 specification."
    ::= { s3TrNodeEntry 7 }

s3TrNodeAriFciErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of ARI FCI errors.  See AC errors,
                Section 3.8.4 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 8 }

s3TrNodeLostFrames OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frames lost.  Section 3.8.6 of
                IEEE 802.5 specification."
    ::= { s3TrNodeEntry 9 }

s3TrNodeRcvCongestErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of receive congestion errors.
                Section 3.8.7 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 10 }

s3TrNodeFrmCopyErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frame copy errors.  Section 3.8.8
                of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 11 }

s3TrNodeTokenErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of token errors.  Section 3.8.10
                of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 12 }

s3TrNodeInternalErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of internal errors.  Section 3.8.2
                of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 13 }

s3TrNodeAbortTransErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of abort delimiter transmitted errors.
                Section 3.8.5 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 14 }

s3TrNodeFrequencyErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frequency errors.  Section 3.8.9
                of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 15 }

s3TrNodeEntProductId OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(18))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "A brief string describing the product specified
                by the vendor.  Section 3.3.2.14 of IEEE 802.5
                specification.

                The characters in the string are represented in
                EBCDIC for IBM products, in ASCII for others."
    ::= { s3TrNodeEntry 16 }

s3TrNodeEntUna OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The Upstream Neighbor Address.  Section 3.3.2.15
                of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 17 }

s3TrNodeEntNodeVersion OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(10))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "String that represents the version of the station
                software.  Section 3.3.2.17 of IEEE 802.5 specification.

                The characters in the string are represented in
                EBCDIC for IBM products, in ASCII for others."
    ::= { s3TrNodeEntry 18 }

s3TrNodeEntPhysDrop OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(4))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This reports the physical location of this node on the
                ring.  Section 3.3.2.13 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 19 }

s3TrNodeEntFuncAddr OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Specifies the functional addresses used by this
                station.  Section 3.3.2.8 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 20 }

s3TrNodeEntAuthFuncClass OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(2))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This specifies the functional classes that are
                allowed to be active in the station.  Section 3.3.2.3
                of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 21 }

s3TrNodeEntAuthAccPriority OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(2))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The maximum priority this station is allowed to use.
                Section 3.3.2.2 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 22 }

s3TrNodeEntGrpAddr OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This contains the group address of this station.
                Section 3.3.2.9 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 23 }

s3TrNodeEntStationId OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This string is used to uniquely identify the station.
                It may be equal to the station's MAC address.
                Section 3.3.2.21 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 24 }

s3TrNodeEntBeaconType OBJECT-TYPE
    SYNTAX  INTEGER {
            reconfiguration(1),
            signalLoss(2),
            bitStreaming(3),
            contentionStreaming(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This specifies the type of beacon frame seen.
                Section 3.3.2.4 of IEEE 802.5 specification."
    ::= { s3TrNodeEntry 25 }

s3TrNodeBeaconCnt OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of beacon frames that have been sent by
                this station."
    ::= { s3TrNodeEntry 26 }

s3TrNodeLastBeaconTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The time of the last beacon frame sent by
                this station."
    ::= { s3TrNodeEntry 27 }

s3TrNodeLastInsertTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The time of the last ring insertion by this
                station.  Time is relative from the system uptime."
    ::= { s3TrNodeEntry 28 }

s3TrNodeFirstInsertTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The time of the first ring insertion by this
                station.  Time is relative from the system uptime."
    ::= { s3TrNodeEntry 29 }

s3TrNodeLastDeinsertTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The time of the last ring deinsertion by this
                station.  Time is relative from the system uptime."
    ::= { s3TrNodeEntry 30 }

s3TrNodeRemoveStation OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            remove(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Removes the MAC address associated with this entry
                from the ring by sending a REMOVE MAC frame if this
                object is written to with remove(2)."
    ::= { s3TrNodeEntry 31 }

s3TrRingStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            beaconing(1),
            notbeaconing(2)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The status of the ring."
    ::= { s3TrRingStats 1 }

s3TrRingFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frames received successfully by the NMM."
    ::= { s3TrRingStats 2 }

s3TrRingOctetsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of octets received successfully by the NMM."
    ::= { s3TrRingStats 3 }

s3TrRingBcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of broadcast frames received successfully
                by the NMM."
    ::= { s3TrRingStats 4 }

s3TrRingLineErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of line errors.  Section 3.8.1 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 5 }

s3TrRingBurstErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of burst errors.  Section 3.8.3 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 6 }

s3TrRingAriFciErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of ARI FCI errors.  See AC errors,
                Section 3.8.4 of IEEE 802.5 specification."
    ::= { s3TrRingStats 7 }

s3TrRingLostFrames OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frames lost.  Section 3.8.6 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 8 }

s3TrRingRcvCongestErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of receive congestion errors.  Section
                3.8.7 of IEEE 802.5 specification."
    ::= { s3TrRingStats 9 }

s3TrRingFrmCopyErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frame copy errors.  Section 3.8.8 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 10 }

s3TrRingTokenErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of token errors.  Section 3.8.10 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 11 }

s3TrRingInternalErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of internal errors.  Section 3.8.2 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 12 }

s3TrRingAbortTransErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of abort delimiter transmitted errors.
                Section 3.8.5 of IEEE 802.5 specification."
    ::= { s3TrRingStats 13 }

s3TrRingFrequencyErrs OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of frequency errors.  Section 3.8.9 of
                IEEE 802.5 specification."
    ::= { s3TrRingStats 14 }

s3TrRingBeaconCnt OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Number of beacon frames that have been seen."
    ::= { s3TrRingStats 15 }

s3TrRingBeaconType OBJECT-TYPE
    SYNTAX  INTEGER {
            reconfiguration(1),
            signalLoss(2),
            bitStreaming(3),
            contentionStreaming(4)
            }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "This specifies the type of beacon frame seen.
                Section 3.3.2.4 of IEEE 802.5 Specification."
    ::= { s3TrRingStats 16 }

s3TrRingLastBeaconTime OBJECT-TYPE
    SYNTAX  TimeTicks
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The time of the last beacon frame sent on the ring.
                Time is relative from the system uptime."
    ::= { s3TrRingStats 17 }

s3TrRingBeaconStation OBJECT-TYPE
    SYNTAX  OCTET STRING (SIZE(6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The MAC address of station last beaconing."
    ::= { s3TrRingStats 18 }

ieee8023IfTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Ieee8023IfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "Statistics for a list of interface entries. There is
                one entry per IEEE 802.3 like 'interface.'"
    ::= { ieee8023 1 }

ieee8023IfEntry OBJECT-TYPE
    SYNTAX  Ieee8023IfEntry
    ACCESS  not-accessible
    STATUS  mandatory
    INDEX   { ieee8023IfIndex }
    ::= { ieee8023IfTable 1 }

Ieee8023IfEntry ::= SEQUENCE {
    ieee8023IfIndex
        INTEGER,
    ieee8023FrmsTxOk
        Counter,
    ieee8023SingleCollFrms
        Counter,
    ieee8023MultipleCollFrms
        Counter,
    ieee8023OctetsTxOk
        Counter,
    ieee8023DefTx
        Counter,
    ieee8023McastFrmsTxOk
        Counter,
    ieee8023BcastFrmsTxOk
        Counter,
    ieee8023LateColls
        Counter,
    ieee8023ExcessColls
        Counter,
    ieee8023IntlMacTxError
        Counter,
    ieee8023CsErrors
        Counter,
    ieee8023ExcessDef
        Counter,
    ieee8023FrmsRxOk
        Counter,
    ieee8023OctetsRxOk
        Counter,
    ieee8023McastFrmsRxOk
        Counter,
    ieee8023BcastFrmsRxOk
        Counter,
    ieee8023TooLongErrors
        Counter,
    ieee8023AlignErrors
        Counter,
    ieee8023FcsErrors
        Counter,
    ieee8023IrLengthErrors
        Counter,
    ieee8023OorLengthFields
        Counter,
    ieee8023IntlMacRxErrors
        Counter,
    ieee8023InitMac
        INTEGER,
    ieee8023PromRxStatus
        INTEGER,
    ieee8023MacSubLayerStatus
        INTEGER,
    ieee8023TxStatus
        INTEGER,
    ieee8023McastRxStatus
        INTEGER,
    ieee8023MacAddress
        PhysAddress,
    ieee8023SqeTestErrors
        Counter
    }

ieee8023IfIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "Index of the interface.  The interface identified by a
                particular value of this index is the same interface as
                identified by the same value of ifIndex."
    ::= { ieee8023IfEntry 1 }

ieee8023FrmsTxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are successfully transmitted.

                This counter is incremented when a frame is successfully
                transmitted, even if one of the collision counters
                (following two objects) is also counted. In other words,
                this count includes transmissions that succeeded after
                some number of collisions.

                This count includes multicast and broadcast frames."
    ::= { ieee8023IfEntry 2 }

ieee8023SingleCollFrms OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are involved in a single
                collision, and are subsequently transmitted successfully.

                If this counter is incremented, then the ieee8023FrmsTxOK
                count will also be incremented AND ieee8023MultipleCollFrms
                will NOT be incremented."
    ::= { ieee8023IfEntry 3 }

ieee8023MultipleCollFrms OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are involved in more than one
                collision and are subsequently transmitted successfully.

                If this counter is incremented, then the ieee8023FrmsTxOK
                count will also be incremented AND ieee8023SingleCollFrms
                will NOT be incremented."
    ::= { ieee8023IfEntry 4 }

ieee8023OctetsTxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The amount of data AND PADDING octets of frames that are
                successfully transmitted.

                This counter includes octets in broadcast and multicast
                frames that are transmitted.

                This count does not include the address fields, length/type
                field, and CRC field of the frame. According to Ethernet
                terminology, it is purely the data field (IP header, etc.)."
    ::= { ieee8023IfEntry 5 }

ieee8023DefTx OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames whose transmission was delayed on its
                first attempt because the medium was busy. Frames involved
                in collisions are NOT included in this count."
    ::= { ieee8023IfEntry 6 }

ieee8023McastFrmsTxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames successfully transmitted to a
                multicast address. This counter does not include frames
                sent to the broadcast address."
    ::= { ieee8023IfEntry 7 }

ieee8023BcastFrmsTxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames successfully transmitted to the
                broadcast address. This counter does not include frames
                sent to a multicast address."
    ::= { ieee8023IfEntry 8 }

ieee8023LateColls OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of times that a collision has been detected
                later than 512 bit times into the transmission of a packet.
                512 bit times is 51.2 micro secs. This type of collision
                is counted twice-both as a late collision and as a regular,
                ordinary collision."
    ::= { ieee8023IfEntry 9 }

ieee8023ExcessColls OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are not transmitted because of
                excessive collisions."
    ::= { ieee8023IfEntry 10 }

ieee8023IntlMacTxError OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that would otherwise be transmitted by
                the station, but could not be sent because of an internal MAC
                sublayer transmit error. If this counter is incremented, then
                none of the other counters in this section are incremented.
                The exact meaning and mechanism for incrementing this counter
                is implementation dependent.

                In short, this is the count of errors for which there are no
                specific counters."
    ::= { ieee8023IfEntry 11 }

ieee8023CsErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of times that carrier sense was lost or never
                appeared when attempting to transmit a packet. This counter
                is incremented ONCE per transmission attempt, even if
                Carrier Sense fluctuates."
    ::= { ieee8023IfEntry 12 }

ieee8023ExcessDef OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that deferred for an excessive period
                of time."
    ::= { ieee8023IfEntry 13 }

ieee8023FrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are successfully received. This
                counter does not include frames received with frame-too-long,
                FCS, length, or alignment errors, or frames lost because of
                internal MAC sublayer error.

                This counter includes broadcast and multicast frames that
                are received."
    ::= { ieee8023IfEntry 14 }

ieee8023OctetsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number entry of data and padding octets in frames that
                are successfully received. This counter does not include
                frames received with frame-too-long, FCS, length, or
                alignment errors, or frames lost because of internal MAC
                sublayer error.

                This counter includes octets in broadcast and multicast
                frames that are received.

                This counter does not include the octets in the address,
                length/type, and CRC fields."
    ::= { ieee8023IfEntry 15 }

ieee8023McastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are successfully received and are
                directed to an active non-broadcast group address. This
                counter does not include frames received with frame-too-long,
                FCS, length, or alignment errors, or frames lost because of
                internal MAC sublayer error.

                Only frames for a multicast address that this interface is
                receiving are counted. Broadcast packets are not included."
    ::= { ieee8023IfEntry 16 }

ieee8023BcastFrmsRxOk OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are successfully received and are
                directed to the broadcast group address. This counter does
                not include frames received with frame-too-long, FCS, length,
                or alignment errors, or frames lost because of internal MAC
                sublayer error.

                Multicast packets are not included."
    ::= { ieee8023IfEntry 17 }

ieee8023TooLongErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are received and exceed the
                maximum permitted frame size. This counter is incremented
                when the frameTooLong error is returned."
    ::= { ieee8023IfEntry 18 }

ieee8023AlignErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are not an integral number of
                octets in length and do not pass the FCS check. This counter
                is incremented when the alignmentError status is returned
                to the LLC."
    ::= { ieee8023IfEntry 19 }

ieee8023FcsErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that are an integral number of octets
                in length and do not pass the FCS check. This counter is
                incremented when the frameCheckError status is returned to
                the LLC."
    ::= { ieee8023IfEntry 20 }

ieee8023IrLengthErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames with a length field value between the
                minimum unpadded LLC data size and the maximum allowed LLC
                data size inclusive, and which do not match the number of LLC
                data octets received. The counter also contains frames with a
                length field value less than the minimum unpadded LLC data
                size."
    ::= { ieee8023IfEntry 21 }

ieee8023OorLengthFields OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames with a length field value greater than
                the maximum allowed LLC data size.

                If true 802.3 is followed for layer management, then this
                counter will be incremented for every IP or ARP frame
                received that uses the Ethernet encapsulation method. Both
                IP and ARP use type field values that will cause this counter
                to be incremented, showing a high error rate."
    ::= { ieee8023IfEntry 22 }

ieee8023IntlMacRxErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that would otherwise be received by the
                station, but could not be accepted because of an internal MAC
                sublayer receive error. If this counter is incremented, then
                none of the other counters in this section are incremented.
                The exact meaning and mechanism for incrementing this counter
                is implementation dependent.

                This is the count of other errors."
    ::= { ieee8023IfEntry 23 }

ieee8023InitMac OBJECT-TYPE
    SYNTAX  INTEGER {
            initialize(1),
            uninitialize(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Reinitializes the MAC and PLS (physical layer signaling).
                All MIB counters are set to 0. The states of the status
                variables (described below) are as follows:

                - The receive and transmit Layer Management state variables
                  (receiveEnabled and transmitEnabled) are set to enable
                  reception and transmission of frames.

                - The promiscuous receive function is disabled.

                - Multicast reception is disabled."
    ::= { ieee8023IfEntry 24 }

ieee8023PromRxStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            disabled(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This variable combines the enable ieee8023PromRx, disable
                ieee8023PromRx, and read ieee8023PromStatus MAC actions.

                Setting this variable to enabled causes the interface to
                accept frames regardless of their destination address.

                When enabled, all received frames increment all counters as
                though those frames were directed to this station.

                Frames can be promiscuously received only if the
                ieee8023MacSubLayerStatus variable is also set to enabled(1)."
    ::= { ieee8023IfEntry 25 }

ieee8023MacSubLayerStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            disabled(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This variable causes the MAC sublayer to enter the normal
                operational state at idle. The PLS is reset by this
                operation. It is accomplished by setting receiveEnabled
                and transmitEnabled to true.

                Setting this variable to enabled(1) enables the MAC sublayer
                to both receive and transmit frames. Setting this variable to
                enabled(1) will also set the ieee8023TransmitStatus variable
                to enabled(1). Similarly, setting this variable to disabled(2)
                will also set ieee8023TransmitStatus to disabled(2).

                Modifying this variable does not change the state of any other
                variables.

                If the variable is set to disabled(2), then any current
                transmission/reception is completed before the
                transmission/reception process is disabled.

                The value returned when this variable is read is the logical
                and of the receiveEnabled and transmitEnabled MAC internal
                state variables. If both are in the enabled state, then
                enabled(1) is returned; otherwise disabled(2) is returned."
    ::= { ieee8023IfEntry 26 }

ieee8023TxStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            disabled(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This variable enables the MAC sublayer to be explicitly
                enabled/disabled for transmitting frames.

                If a frame is being transmitted when this variable is set to
                disabled(2), that transmission is completed.

                Note that ieee8023MACSubLayerStatus has an effect on this
                variable."
    ::= { ieee8023IfEntry 27 }

ieee8023McastRxStatus OBJECT-TYPE
    SYNTAX  INTEGER {
            enabled(1),
            disabled(2)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Enables/disables reception of multicast frames. To actually
                receive multicasts, both this variable AND
                ieee8023MacSubLayerStatus must be set to enabled."
    ::= { ieee8023IfEntry 28 }

ieee8023MacAddress OBJECT-TYPE
    SYNTAX  PhysAddress (SIZE(6))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "This object contains the MAC station address (i.e., the
                Ethernet address)."
    ::= { ieee8023IfEntry 29 }

ieee8023SqeTestErrors OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of times that the SQE TEST ERROR status was
                received."
    ::= { ieee8023IfEntry 30 }

ieee8023CollTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Ieee8023CollEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing information on collision activity."
    ::= { ieee8023 2 }

ieee8023CollEntry OBJECT-TYPE
    SYNTAX  Ieee8023CollEntry
    ACCESS  not-accessible
    STATUS  mandatory
    INDEX   { ieee8023CollRetrans,
              ieee8023CollIndex }
    ::= { ieee8023CollTable 1 }

Ieee8023CollEntry ::= SEQUENCE {
    ieee8023CollRetrans
        INTEGER,
    ieee8023CollIndex
        INTEGER,
    ieee8023Collisions
        Counter
    }

ieee8023CollRetrans OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The entry corresponding to the number of attempts made
                before a frame was successfully transmitted. The range is
                from 1 to 15."
    ::= { ieee8023CollEntry 1 }

ieee8023CollIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The index value that uniquely identifies the interface to
                which this entry is applicable. The interface identified by
                a particular value of this index is the same interface as
                identified by the same value of ifIndex."
    ::= { ieee8023CollEntry 2 }

ieee8023Collisions OBJECT-TYPE
    SYNTAX  Counter
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The number of frames that were retransmitted a specific
                number of times."
    ::= { ieee8023CollEntry 3 }

ieee8023GroupTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Ieee8023GroupEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
                "A table containing information on group addresses. There
                are five entries in the table."
    ::= { ieee8023 3 }

ieee8023GroupEntry OBJECT-TYPE
    SYNTAX  Ieee8023GroupEntry
    ACCESS  not-accessible
    STATUS  mandatory
    INDEX   { ieee8023GroupIndex,
              ieee8023GroupAddress }
    ::= { ieee8023GroupTable 1 }

Ieee8023GroupEntry ::= SEQUENCE {
    ieee8023GroupIndex
        INTEGER,
    ieee8023GroupAddress
        PhysAddress,
    ieee8023GroupType
        INTEGER
    }

ieee8023GroupIndex OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
                "The index value that uniquely identifies the interface to
                which this entry is applicable. The interface identified by
                a particular value of this index is the same interface as
                identified by the same value of ifIndex."
    ::= { ieee8023GroupEntry 1 }

ieee8023GroupAddress OBJECT-TYPE
    SYNTAX  PhysAddress (SIZE(6))
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "A group address to which this Ethernet-like interface
                responds.

                ***ACCESS VARIATION - changed access from read-only"
    ::= { ieee8023GroupEntry 2 }

ieee8023GroupType OBJECT-TYPE
    SYNTAX  INTEGER {
            other(1),
            invalid(2),
            flatnet(3),
            segmentnet(4)
            }
    ACCESS  read-write
    STATUS  mandatory
    DESCRIPTION
                "Type of group address.

                Setting this object to the value invalid(2) invalidates the
                corresponding entry in the ieee8023GroupTable. That is, it
                effectively disassociates the interface identified with said
                entry from the group address identified with said entry.
                Whether the agent removes an invalidated entry from the table
                is an implementation-specific matter. Accordingly, management
                stations must be prepared to receive tabular information from
                agents that corresponds to entries not currently in use.
                Proper interpretation of such entries requires examination of
                the relevant ieee8023GroupType object.

                A value of flatnet(3) indicates a multicast address for
                Synoptics autotopology flat net hello messages. A value of
                segmentnet(4) indicates a multicast address for Synoptics
                autotopology segment net hello messages."
    ::= { ieee8023GroupEntry 3 }

chassisPowerSupplyFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3ChassisPsStatus }
    DESCRIPTION
                "Concentrator power supply failure."
    ::= 0

chassisFanFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3ChassisFanStatus }
    DESCRIPTION
                "Concentrator fan failure."
    ::= 1

portAutoPartition TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetPortPartStatus,
                  s3EnetPortJabberStatus }
    DESCRIPTION
                "Port auto partitions (wraps)."
    ::= 4

portDTEJabbering TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetPortJabberStatus }
    DESCRIPTION
                "Ethernet DTE jabbering detected."
    ::= 5

localBridgeDiagnostic TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetLocBridgeDiagSts }
    DESCRIPTION
                "NMM detects bridge failure."
    ::= 8

remoteBridgePortOperationChanged TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRemBridgePortOpSts }
    DESCRIPTION
                "Bridge changes from standby <-> operation."
    ::= 9

remoteBridgeDiagnostic TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRemBridgeDiagSts }
    DESCRIPTION
                "NMM detects remote bridge failure."
    ::= 10

boardLEDFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3CommonBoardStatus }
    DESCRIPTION
                "Board is on but LED is off."
    ::= 11

boardPowerSupplyFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3CommonBoardPsStatus }
    DESCRIPTION
                "Board power supply failure."
    ::= 27

localBridgeOperationChanged TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetLocBridgeStandbySts }
    DESCRIPTION
                "Bridge changes from standby <-> operation."
    ::= 30

remoteBridgeOperationChanged TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRemBridgeStandbySts }
    DESCRIPTION
                "Bridge changes from standby <-> operation."
    ::= 31

routerOperationChanged TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRouterStandbySts }
    DESCRIPTION
                "Router changes from standby <-> operation."
    ::= 33

routerDiagnostic TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRouterDiagSts }
    DESCRIPTION
                "NMM detects router failure."
    ::= 34

keyManagementFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3AgentMibLevel,
                  s3AgentFeatureLevel }
    DESCRIPTION
                "NMM detects that its key doesn't match the 
                configuration."
    ::= 35

nmmSaturationA TRAP-TYPE
    ENTERPRISE  synoptics
    DESCRIPTION
                "NMM is dropping packets due to overload."
    ::= 44

lattisSecureInitRequired TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3SlotModuleType }
    DESCRIPTION
                "This trap is sent by a 331xS Ethernet NMM+ when a
                LattisSecure Host Module needs initialization.  The
                location of the module is indicated by the instance
                identifier part of the returned variable, and the value
                of the variable tells the board identity."
    ::= 46

redPsPlus5vCurrentExceed TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3RedPsPrimaryConfig,
                  s3RedPsSecondaryConfig,
                  s3RedPsPlus5vCurrent }
    DESCRIPTION
                "This trap is sent when the current level on the +5 V
                supply exceeds the maximum recommended level: 1) 30 amps
                if at least one of the power supplies is a 3001. 2) 50
                amps if both power supplies are 3002. Note: The agent
                reads the current level only when it restarts.Changes in
                the current level that occur while the agent is running
                will not be noticed.  Thus, this trap can only be
                generated at the end of the restart sequence."
    ::= 47

redPsPlus12vCurrentExceed TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3RedPsPrimaryConfig,
                  s3RedPsSecondaryConfig,
                  s3RedPsPlus12vCurrent }
    DESCRIPTION
                "This trap is sent when the current level on the +12 V
                supply exceeds the maximum recommended level of 15 amps
                for any set of power supplies.  Note: The agent reads
                the current level only when it restarts.  Changes in the
                current level that occur while the agent is running will
                not be noticed.  Thus, this trap can only be generated
                at the end of the restart sequence."
    ::= 48

redPsAmbientTempStatChg TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3RedPsAmbientTempStatus,
                  s3RedPsAmbientTemperature }
    DESCRIPTION
                "This trap is sent whenever there is a change (in either
                direction) in the psAmbientTempStatus variable."
    ::= 49

redPsSummingDiodeFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3RedPsDiodeStatus }
    DESCRIPTION
                "This trap is sent whenever the reported status of
                either 3100R summing diode changes from 'Ok' to 'Fail'."
    ::= 50

boardSwap TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3SlotModuleId,
                  s3SlotModuleType,
                  s3SlotModuleMdaId }
    DESCRIPTION
                "This trap is sent whenever a board is inserted or
                removed.  The values returned are those before the
                action was taken.  Thus, the value of s3SlotModuleType
                will be empty(1) when a board is inserted.  The instance
                value for the variables is the slot number of the board.
                On receiving the trap, a manager should use a get
                request to find the current values of these variables."
    ::= 51

enetChannelChange TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetCommonBoardEnetAB }
    DESCRIPTION
                "This trap is sent whenever a board is switched
                from one channel to the other.  The value returned
                is the one before the action was taken. Thus, the
                value of s3EnetCommonBoardEnetAB will specify
                channel that the board was attached to before
                the channel was changed.  The instance value
                from s3EnetCommonBoardEnetAB identifies the
                board that was affected."
    ::= 53

flashUpdateFailure TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3AgentFlashStatus }
    DESCRIPTION
                "This trap is sent whenever the agent failed
                to update the local image due to flash device
                failure."
    ::= 54

redundPortSwitchover TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRedPortRedundMode,
                  s3EnetRedPortOperStatus,
                  s3EnetRedPortCompanionSlotNo,
                  s3EnetRedPortCompanionPortNo }
    DESCRIPTION
                "This trap is sent whenever NMM detects a redundant port
                pair switchover.  The values returned are those after
                the action was taken.  The instance values (slot.port)
                for the variables is for the port from which the
                switchover occurred."
    ::= 58

redundBadRemCfgDetected TRAP-TYPE
    ENTERPRISE  synoptics
    VARIABLES   { s3EnetRedPortRemoteOperStatus,
                  s3EnetRedPortRedundMode }
    DESCRIPTION
                "This trap is sent periodically when the NMM detects
                a s3EnetRedPortRemoteOperStatus of flidl(3) on a port
                set for hardware redundancy. The trap is also sent
                when the port's s3EnetRedPortRemoteOperStatus is
                unknown(7) and the companion port has a good link.
                The instance values (slot.port) for the variables
                is for the receiving port."
    ::= 59


END