File: sigrok-cli.1

package info (click to toggle)
sigrok-cli 0.3.0-2
  • links: PTS
  • area: main
  • in suites: wheezy
  • size: 1,460 kB
  • sloc: sh: 11,006; ansic: 1,087; makefile: 10
file content (322 lines) | stat: -rw-r--r-- 10,441 bytes parent folder | download
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
.TH SIGROK\-CLI 1 "March 18, 2012"
.SH "NAME"
sigrok\-cli \- Command-line client for the sigrok logic analyzer software
.SH "SYNOPSIS"
.B sigrok\-cli \fR[\fB\-hVlDdiIoOptwas\fR] [\fB\-h\fR|\fB\-\-help\fR] [\fB\-V\fR|\fB\-\-version\fR] [\fB\-l\fR|\fB\-\-loglevel\fR level] [\fB\-D\fR|\fB\-\-list\-devices\fR] [\fB\-d\fR|\fB\-\-device\fR device] [\fB\-i\fR|\fB\-\-input\-file\fR filename] [\fB\-I\fR|\fB\-\-input\-format\fR format] [\fB\-o\fR|\fB\-\-output\-file\fR filename] [\fB\-O\fR|\fB\-\-output-format\fR format] [\fB\-p\fR|\fB\-\-probes\fR probelist] [\fB\-t\fR|\fB\-\-triggers\fR triggerlist] [\fB\-w\fR|\fB\-\-wait\-trigger\fR] [\fB\-a\fR|\fB\-\-protocol\-decoders\fR list] [\fB\-s\fR|\fB\-\-protocol\-decoder\-stack\fR stack] [\fB\-\-time\fR ms] [\fB\-\-samples\fR numsamples] [\fB\-\-continuous\fR]
.SH "DESCRIPTION"
.B sigrok\-cli
is a cross-platform command line utility for the
.B sigrok
logic analyzer software.
.PP
The command-line frontend for sigrok cannot display graphical output, but is
still sufficient to run through the whole process of hardware initialization,
acquisition, protocol decoding and saving the session.
.PP
It is useful for running on remote or embedded systems, netbooks, PDAs,
and for various other use-cases. It can display samples on standard output or
save them in various file formats.
.SH "OPTIONS"
.TP
.B "\-h, \-\-help"
Show a help text and exit.
.TP
.B "\-V, \-\-version"
Show
.B sigrok-cli
version, and information about supported hardware drivers, input file
formats, output file formats, and protocol decoders.
.TP
.BR "\-l, \-\-loglevel " <level>
Set the libsigrok and libsigrokdecode loglevel. At the moment
.B sigrok-cli
doesn't support setting the two loglevels independently. The higher the
number, the more debug output will be printed. Valid loglevels are
.BR 0 " (NONE),"
.BR 1 " (ERR),"
.BR 2 " (WARN),"
.BR 3 " (INFO),"
.BR 4 " (DBG), and"
.BR 5 " (SPEW)."
.TP
.B "\-D, \-\-list\-devices"
List all logic analyzer devices found on the system. This actively scans for
devices (USB, serial port, and others).
.TP
.BR "\-d, \-\-device " <device>
The device to use for acquisition. It can be specified by ID as reported by
.BR "\-\-list\-devices" ,
or by the name of the driver as reported by
.BR \-\-version .
.sp
A device can optionally be followed by a colon-separated list of device
options, where each option takes the form
.BR key=value .
For example, to set the samplerate on the first device you might specify
.sp
.RB "  $ " "sigrok\-cli \-d 0:samplerate=1m"
.sp
Samplerate is an option common to most devices. The argument specifies the
samplerate in Hz. You can also specify the samplerate in kHz, MHz or GHz.
The following are all equivalent:
.sp
.RB "  $ " "sigrok\-cli \-\-samples 100 \-d 0:samplerate=1000000"
.sp
.RB "  $ " "sigrok\-cli \-\-samples 100 \-d 0:samplerate=1m"
.sp
.RB "  $ " "sigrok\-cli \-\-samples 100 \-d ""0:samplerate=1 MHz""
.TP
.BR "\-i, \-\-input\-file " <filename>
Load input from a file instead of a hardware device. If the
.B \-\-input\-format
option is not supplied, sigrok-cli attempts to autodetect the file format of
the input file.
.TP
.BR "\-I, \-\-input\-format " <format>
When loading an input file, assume it's in the specified format. If this
option is not supplied (in addition to
.BR \-\-input\-file ),
sigrok-cli attempts to autodetect the file format of the input file.
.TP
.BR "\-o, \-\-output\-file " <filename>
Save output to a file instead of writing it to stdout. The default format
used when saving is the sigrok session file format. This can be changed with
the
.B \-\-output\-format
option.
.TP
.BR "\-O, \-\-output\-format " <formatname>
Set the output format to use. Use the
.B \-V
option to see a list of available output formats. The format name may
optionally be followed by a colon-separated list of options, where each
option takes the form
.BR "key=value" .
.sp
Supported formats currently include
.BR bits ,
.BR hex ,
.BR ascii ,
.BR binary ,
.BR vcd ,
.BR ols ,
.BR gnuplot ,
.BR chronovu-la8 ", and"
.BR csv .
.sp
The
.B bits
or
.B hex
formats, for an ASCII bit or ASCII hexadecimal display, can take a "width" option, specifying the number of samples (in bits) to display per line. Thus
.B hex:width=128
will display 128 bits per line, in hexadecimal:
.sp
 1:ffff ffff ffff ffff ffff ffff ffff ffff
 2:ff00 ff00 ff00 ff00 ff00 ff00 ff00 ff00
.sp
The lines always start with the probe number (or name, if defined), followed by a colon. If no format is specified, it defaults to
.BR bits:width=64 ,
like this:
.sp
 1:11111111 11111111 11111111 11111111 [...]
 2:11111111 00000000 11111111 00000000 [...]
.TP
.BR "\-p, \-\-probes " <probelist>
A comma-separated list of probes to be used in the session.
.sp
The default is to use all the probes available on a device. You can name
a probe like this:
.BR "1=CLK" .
A range of probes can also be given, in the form
.BR "1\-5" .
.sp
Example:
.sp
 $
.B "sigrok\-cli \-\-samples 100 \-\-probes 1=CLK,2\-4,7"
.br
 CLK:11111111 11111111 11111111 11111111 [...]
   2:11111111 11111111 11111111 11111111 [...]
   3:11111111 11111111 11111111 11111111 [...]
   4:11111111 11111111 11111111 11111111 [...]
   7:11111111 11111111 11111111 11111111 [...]
.sp
The comma-separated list is processed from left to right, i.e. items farther
to the right override previous items. For example
.B "1=CS,1=MISO"
will set the name of probe 1 to
.BR "MISO" .
.sp
Also, while
.B "5=MOSI,6=MISO"
will only select probes 5 and 6, and set their names to MISO and MOSI, the
command line
.B "5=MOSI,6=MISO,1\-8"
will select probes 1\-8 (including 5 and 6, of course), but the names specified
for probes 5 and 6 will be reset to the defaults by the
.B "1\-8"
probe selection.
.TP
.BR "\-t, \-\-triggers " <triggerlist>
A comma-separated list of triggers to use, of the form
.BR "<probe>=<trigger>" .
You can use the name or number of the probe, and the trigger itself is a
series of characters:
.sp
.BR "0 or 1" :
A low or high value on the pin.
.br
.BR "r or f" :
A rising or falling value on the pin. An
.B r
effectively corresponds to
.BR 01 .
.br
.BR "c" :
Any kind of change on a pin (either a rising or a falling edge).
.sp
Not every device supports all of these trigger types. Use the
.B "\-d <device>"
argument (with no other arguments) to see which triggers your device supports.
.TP
.BR "\-w, \-\-wait-trigger"
Don't output any sample data (even if it's actually received from the logic
analyzer) before the trigger condition is met. In other words, do not output
any pre-trigger data. This option is useful if you don't care about the data
that came before the trigger (but the logic analyzer hardware delivers this
data to sigrok nonetheless).
.TP
.BR "\-a, \-\-protocol\-decoders " <list>
This option allows the user to specify a comma-separated list of protocol
decoders to be used in this session. The decoders are specified by their
ID, as shown in the
.B \-\-version
output.
.sp
Example:
.sp
 $
.B "sigrok\-cli \-i <file.sr> \-a i2c"
.sp
Each protocol decoder can optionally be followed by a colon-separated list
of options, where each option takes the form
.BR "key=value" .
.sp
Example:
.sp
 $
.B "sigrok\-cli \-i <file.sr> \-a uart:baudrate=115200:parity=odd"
.sp
The list of supported options depends entirely on the protocol decoder. Every
protocol decoder has different options it supports.
.sp
Any "options" specified for a protocol decoder which are not actually
supported options, will be interpreted as being probe name/number assignments.
.sp
Example:
.sp
 $
.B "sigrok\-cli \-i <file.sr>"
.br
.B "              \-a spi:wordsize=9:miso=1:mosi=5:sck=3:cs=0"
.sp
In this example,
.B wordsize
is an option supported by the
.B spi
protocol decoder. Additionally, the user tells sigrok to decode the SPI
protocol using probe 1 as MISO signal for SPI, probe 5 as MOSI, probe 3
as SCK, and probe 0 as CS# signal.
.TP
.BR "\-s, \-\-protocol\-decoder\-stack " <stack>
This option allows the user to specify a protocol decoder stack, i.e.
the way in which one protocol decoder's output gets piped into another
protocol decoder.
.sp
The decoders are specified by their ID, as shown in the
.B \-\-version
output. In addition to the
.B \-s
option, all protocol decoders that are used in a stack, must also be specified
(together with their options, if any) using the
.B \-a
parameter.
.sp
Example:
.sp
 $
.B "sigrok\-cli \-i <file.sr> \-a i2c:sda=4,scl=7,rtc8564"
.br
.B "              \-s i2c,rtc8564"
.sp
In this example, the
.B \-s
option specifies that the output of the
.BR i2c " decoder"
is piped into the
.BR rtc8564 " decoder,"
i.e., the
.BR rtc8564 " decoder"
is stacked on top of the
.BR i2c " decoder."
.sp
The respective protocol decoder options and probe name/number assignments
must be given using the
.B \-a
option (you cannot specify them in the
.B \-s
option).
.TP
.BR "\-\-time " <ms>
Sample for
.B <ms>
milliseconds, then quit. You can optionally follow the number by
.B s
to state the number of seconds to sample instead. For example,
.B "\-\-time 2s"
will sample for two seconds.
.TP
.BR "\-\-samples " <numsamples>
Acquire
.B <numsamples>
samples, then quit.
.TP
.BR "\-\-continuous"
Sample continuously until stopped. Not all devices support this.
.SH "EXAMPLES"
In order to get exactly 100 samples from the (only) detected logic analyzer
hardware, run the following command:
.TP
.B "  sigrok\-cli \-\-samples 100"
.TP
If you want to sample data for 3 seconds, use:
.TP
.B "  sigrok\-cli \-\-time 3000"
.TP
Alternatively, you can also use:
.TP
.B "  sigrok\-cli \-\-time 3s"
.TP
To capture data from 4 probes lasting 100ms at 10 MHz starting at the trigger condition 1:high, 2:rising, 3:low, 4:high, use:
.TP
.B "  sigrok\-cli -d 0:samplerate=10m \-O bits \-p 1\-4 \-\-time 100 \\\\"
.B "      \-\-wait\-trigger \-\-triggers 1=1,2=r,3=0,4=1 "
.SH "EXIT STATUS"
.B sigrok\-cli
exits with 0 on success, 1 on most failures.
.SH "SEE ALSO"
\fBsigrok\-qt\fP(1),
\fBsigrok\-gtk\fP(1)
.SH "BUGS"
Please report any bugs on the sigrok\-devel mailing list
.RB "(" sigrok\-devel@lists.souceforge.net ")."
.SH "LICENSE"
.B sigrok\-cli
is covered by the GNU General Public License (GPL). Some portions are
licensed under the "GPL v2 or later", some under "GPL v3 or later".
.SH "AUTHORS"
Please see the individual source code files.
.PP
This manual page was written by Uwe Hermann <uwe@hermann\-uwe.de>.
It is licensed under the terms of the GNU GPL (version 2 or later).