File: commandlinehandler.ads

package info (click to toggle)
spark 2012.0.deb-9
  • links: PTS, VCS
  • area: main
  • in suites: jessie, jessie-kfreebsd
  • size: 29,260 kB
  • ctags: 3,098
  • sloc: ada: 186,243; cpp: 13,497; makefile: 685; yacc: 440; lex: 176; ansic: 119; sh: 16
file content (95 lines) | stat: -rw-r--r-- 3,975 bytes parent folder | download | duplicates (2)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
-------------------------------------------------------------------------------
-- (C) Altran Praxis Limited
-------------------------------------------------------------------------------
--
-- The SPARK toolset is free software; you can redistribute it and/or modify it
-- under terms of the GNU General Public License as published by the Free
-- Software Foundation; either version 3, or (at your option) any later
-- version. The SPARK toolset is distributed in the hope that it will be
-- useful, but WITHOUT ANY WARRANTY; without even the implied warranty of
-- MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General
-- Public License for more details. You should have received a copy of the GNU
-- General Public License distributed with the SPARK toolset; see file
-- COPYING3. If not, go to http://www.gnu.org/licenses for a complete copy of
-- the license.
--
--=============================================================================

with E_Strings;

--# inherit Ada.Characters.Handling,
--#         Ada.Characters.Latin_1,
--#         CommandLineData,
--#         ExaminerConstants,
--#         E_Strings,
--#         FileSystem,
--#         ScreenEcho,
--#         SPARK_IO;

package CommandLineHandler is

   type Command_Strings is record
      Current_Position : E_Strings.Positions;
      Contents         : E_Strings.T;
   end record;

   type S_Typs is (S_Empty,
                   S_Equal,
                   S_Switch_Character,
                   S_Comma,
                   S_String,
                   S_Continue);

   type Symbols is record
      Typ        : S_Typs;
      The_String : E_Strings.T;
   end record;

   function Check_Option_Name (Opt_Name : E_Strings.T;
                               Str      : String) return Boolean;

   procedure Skip_Spaces (Command_String : in out Command_Strings);
   --# derives Command_String from *;

   procedure Read_The_String (Command_String : in out Command_Strings;
                              Next_Symbol    : in out Symbols);
   --# derives Command_String,
   --#         Next_Symbol    from *,
   --#                             Command_String;

   ----------------------------------------------------------------------------
   -- Reads the default switch file "spark.sw", then the user's
   -- command-line switches.  Parses these and sets the content
   -- of CommandLineData.Content appropriately.  Illegal or
   -- contradictory switches are detected and reported.
   --
   -- As a special case, if -noswitch has been given on the command-line,
   -- then the default switch file "spark.sw" is completely ignored.
   ----------------------------------------------------------------------------
   procedure Process;
   --# global in out CommandLineData.Content;
   --#        in out SPARK_IO.File_Sys;
   --# derives CommandLineData.Content,
   --#         SPARK_IO.File_Sys       from CommandLineData.Content,
   --#                                      SPARK_IO.File_Sys;

   ----------------------------------------------------------------------------
   -- Reads and parses the default switch file, setting
   -- CommandLineData.Content as it goes, but doesn't
   -- check for existence or non-overlapping of
   -- input files.  Used by tools like SPARKFormat
   -- which want to be able to read the default switch
   -- file, but don't care if the index file(s) (and so on)
   -- don't actually exist.
   --
   -- As a special case, if -noswitch has been given on the command-line,
   -- then the default switch file "spark.sw" is completely ignored.
   ----------------------------------------------------------------------------
   procedure Process_Defaults_From_Switch_File;
   --# global in out CommandLineData.Content;
   --#        in out SPARK_IO.File_Sys;
   --# derives CommandLineData.Content,
   --#         SPARK_IO.File_Sys       from CommandLineData.Content,
   --#                                      SPARK_IO.File_Sys;

end CommandLineHandler;