1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137
|
<?xml version='1.0'?>
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
"http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd">
<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
<refentry id="sd_bus_start"
xmlns:xi="http://www.w3.org/2001/XInclude">
<refentryinfo>
<title>sd_bus_start</title>
<productname>systemd</productname>
</refentryinfo>
<refmeta>
<refentrytitle>sd_bus_start</refentrytitle>
<manvolnum>3</manvolnum>
</refmeta>
<refnamediv>
<refname>sd_bus_start</refname>
<refpurpose>Initiate a bus connection to the D-bus broker daemon
</refpurpose>
</refnamediv>
<refsynopsisdiv>
<funcsynopsis>
<funcsynopsisinfo>#include <systemd/sd-bus.h></funcsynopsisinfo>
<funcprototype>
<funcdef>int <function>sd_bus_start</function></funcdef>
<paramdef>sd_bus *<parameter>bus</parameter></paramdef>
</funcprototype>
</funcsynopsis>
</refsynopsisdiv>
<refsect1>
<title>Description</title>
<para><function>sd_bus_start()</function> connects an existing bus connection object to the D-Bus
broker daemon, usually
<citerefentry project='die-net'><refentrytitle>dbus-daemon</refentrytitle><manvolnum>1</manvolnum></citerefentry>
or
<citerefentry project='mankier'><refentrytitle>dbus-broker</refentrytitle><manvolnum>1</manvolnum></citerefentry>.
The mechanism to use for the connection must be configured before the call to
<function>sd_bus_start()</function>, using one of
<citerefentry><refentrytitle>sd_bus_set_address</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
<citerefentry><refentrytitle>sd_bus_set_fd</refentrytitle><manvolnum>3</manvolnum></citerefentry>, or
<citerefentry><refentrytitle>sd_bus_set_exec</refentrytitle><manvolnum>3</manvolnum></citerefentry>.
<function>sd_bus_start()</function> will open the connection socket or spawn the executable as
needed, and asynchronously start a <function>org.freedesktop.DBus.Hello()</function> call. The
answer to the Hello call will be processed later from
<citerefentry><refentrytitle>sd_bus_process</refentrytitle><manvolnum>3</manvolnum></citerefentry>. If
opening of the connection or queuing of the asynchronous call fail, the connection will be closed with
<citerefentry><refentrytitle>sd_bus_close</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para>
<para>In most cases, it is better to use
<citerefentry><refentrytitle>sd_bus_default_user</refentrytitle><manvolnum>3</manvolnum></citerefentry>,
<citerefentry><refentrytitle>sd_bus_default_system</refentrytitle><manvolnum>3</manvolnum></citerefentry>
or related calls instead of the more low-level <function>sd_bus_new()</function> and
<function>sd_bus_start()</function>. The higher-level functions not only allocate a bus object but also
start the connection to a well-known bus in a single function call.</para>
</refsect1>
<refsect1>
<title>Return Value</title>
<para>On success, this function returns a non-negative integer. On failure, it returns a negative
errno-style error code.</para>
<refsect2 id='errors'>
<title>Errors</title>
<variablelist>
<varlistentry>
<term><constant>-EINVAL</constant></term>
<listitem><para>The input parameter <parameter>bus</parameter> is <constant>NULL</constant>.
</para>
<xi:include href="version-info.xml" xpointer="v246"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>-ENOPKG</constant></term>
<listitem><para>Bus object <parameter>bus</parameter> could not be resolved.</para>
<xi:include href="version-info.xml" xpointer="v246"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>-EPERM</constant></term>
<listitem><para>The input parameter <parameter>bus</parameter> is in a wrong state
(<function>sd_bus_start()</function> may only be called once on a newly-created bus object).</para>
<xi:include href="version-info.xml" xpointer="v246"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>-ECHILD</constant></term>
<listitem><para>The bus object <parameter>bus</parameter> was created in a different
process.</para>
<xi:include href="version-info.xml" xpointer="v246"/>
</listitem>
</varlistentry>
</variablelist>
<para>In addition, other connection-related errors may be returned. See
<citerefentry><refentrytitle>sd_bus_send</refentrytitle><manvolnum>3</manvolnum></citerefentry>.</para>
</refsect2>
</refsect1>
<xi:include href="libsystemd-pkgconfig.xml" />
<refsect1>
<title>History</title>
<para><function>sd_bus_start()</function> was added in version 246.</para>
</refsect1>
<refsect1>
<title>See Also</title>
<para><simplelist type="inline">
<member><citerefentry><refentrytitle>systemd</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
<member><citerefentry><refentrytitle>sd-bus</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
<member><citerefentry><refentrytitle>sd_bus_default</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
<member><citerefentry><refentrytitle>sd_bus_call_async</refentrytitle><manvolnum>3</manvolnum></citerefentry></member>
</simplelist></para>
</refsect1>
</refentry>
|