1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741
|
<?xml version='1.0'?>
<!DOCTYPE refentry PUBLIC "-//OASIS//DTD DocBook XML V4.5//EN"
"http://www.oasis-open.org/docbook/xml/4.5/docbookx.dtd">
<!-- SPDX-License-Identifier: LGPL-2.1-or-later -->
<refentry id="systemd.net-naming-scheme" xmlns:xi="http://www.w3.org/2001/XInclude">
<refentryinfo>
<title>systemd.net-naming-scheme</title>
<productname>systemd</productname>
</refentryinfo>
<refmeta>
<refentrytitle>systemd.net-naming-scheme</refentrytitle>
<manvolnum>7</manvolnum>
</refmeta>
<refnamediv>
<refname>systemd.net-naming-scheme</refname>
<refpurpose>Network device naming schemes</refpurpose>
</refnamediv>
<refsect1>
<title>Description</title>
<para>Network interfaces names and MAC addresses may be generated based on certain stable interface
attributes. This is possible when there is enough information about the device to generate those
attributes and the use of this information is configured. This page describes interface naming, i.e. what
possible names may be generated. Those names are generated by the
<citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>
builtin <command>net_id</command> and exported as
<citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry>
properties (<varname>ID_NET_NAME_ONBOARD=</varname>, <varname>ID_NET_LABEL_ONBOARD=</varname>,
<varname>ID_NET_NAME_PATH=</varname>, <varname>ID_NET_NAME_SLOT=</varname>).</para>
<para>Names and MAC addresses are derived from various stable device metadata attributes. Newer versions
of <command>systemd-udevd</command> take more of these attributes into account, improving (and thus
possibly changing) the names and addresses used for the same devices. Different versions of those
generation rules are called "naming schemes". The default naming scheme is chosen at compilation time.
Usually this will be the latest implemented version, but it is also possible to set one of the older
versions to preserve compatibility. This may be useful for example for distributions, which may introduce
new versions of systemd in stable releases without changing the naming scheme. The naming scheme may also
be overridden using the <varname>net.naming_scheme=</varname> kernel command line switch, see
<citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry>.
Available naming schemes are described below.</para>
<para>After the udev properties have been generated, appropriate udev rules may be used to actually rename
devices based on those properties. See the description of <varname>NamePolicy=</varname> and
<varname>MACAddressPolicy=</varname> in
<citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>.</para>
<para>Note that while the concept of network interface naming schemes is primarily relevant in the
context of <filename>systemd-udevd.service</filename>, the
<citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
container manager also takes it into account when naming network interfaces, see below.</para>
</refsect1>
<refsect1>
<title>Policies</title>
<para>All names start with a two-character prefix that signifies the interface type.</para>
<table>
<title>Two character prefixes based on the type of interface</title>
<tgroup cols='2'>
<thead>
<row>
<entry>Prefix</entry>
<entry>Description</entry>
</row>
</thead>
<tbody>
<row>
<entry><constant>en</constant></entry>
<entry>Ethernet</entry>
</row>
<row>
<entry><constant>ib</constant></entry>
<entry>InfiniBand</entry>
</row>
<row>
<entry><constant>sl</constant></entry>
<entry>Serial line IP (slip)</entry>
</row>
<row>
<entry><constant>wl</constant></entry>
<entry>Wireless local area network (WLAN)</entry>
</row>
<row>
<entry><constant>ww</constant></entry>
<entry>Wireless wide area network (WWAN)</entry>
</row>
</tbody>
</tgroup>
</table>
<para>The <citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry>
<command>net_id</command> builtin exports the following device properties:</para>
<variablelist>
<varlistentry>
<term><varname>ID_NET_NAME_ONBOARD=</varname><replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></term>
<term><varname>ID_NET_NAME_ONBOARD=</varname><replaceable>prefix</replaceable><constant>d</constant><replaceable>number</replaceable></term>
<listitem><para>This name is set based on the numeric ordering information given by the firmware
for on-board devices. Different schemes are used depending on the firmware type, as described in
the table below.</para>
<table>
<title>On-board naming schemes</title>
<tgroup cols='2'>
<thead>
<row>
<entry>Format</entry>
<entry>Description</entry>
</row>
</thead>
<tbody>
<row>
<entry><replaceable>prefix</replaceable><constant>o</constant><replaceable>number</replaceable></entry>
<entry>PCI on-board index</entry>
</row>
<row>
<entry><replaceable>prefix</replaceable><constant>d</constant><replaceable>number</replaceable></entry>
<entry>DeviceTree alias index</entry>
</row>
</tbody>
</tgroup>
</table>
<xi:include href="version-info.xml" xpointer="v243"/>
</listitem>
</varlistentry>
<varlistentry>
<term><varname>ID_NET_LABEL_ONBOARD=</varname><replaceable>label</replaceable></term>
<listitem><para>This property is set based on textual label given by the firmware for on-board
devices. This is only available for PCI devices.</para>
<xi:include href="version-info.xml" xpointer="v243"/>
</listitem>
</varlistentry>
<varlistentry>
<term><varname>ID_NET_NAME_MAC=</varname><replaceable>prefix</replaceable><constant>x</constant><replaceable>AABBCCDDEEFF</replaceable></term>
<listitem><para>This name consists of the prefix, letter <constant>x</constant>, and 12 hexadecimal
digits of the MAC address. It is available if the device has a fixed MAC address. Because this name
is based on an attribute of the card itself, it remains "stable" when the device is moved (even
between machines), but will change when the hardware is replaced.</para>
<xi:include href="version-info.xml" xpointer="v243"/>
</listitem>
</varlistentry>
<varlistentry>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</term>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable><constant>v</constant><replaceable>slot</replaceable></term>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable><constant>x</constant><replaceable>slot</replaceable></term>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></term>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</term>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>v</constant><replaceable>slot</replaceable></term>
<term><varname>ID_NET_NAME_SLOT=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>r</constant><replaceable>slot</replaceable></term>
<listitem><para>This property describes the slot position. Different schemes are used depending on
the bus type, as described in the table below. In case of USB, BCMA, and SR-VIO devices, the full
name consists of the prefix, PCI slot identifier, and USB or BCMA or SR-VIO slot identifier. The
first two parts are denoted as "…" in the table below.</para>
<table>
<title>Slot naming schemes</title>
<tgroup cols='2'>
<thead>
<row>
<entry>Format</entry>
<entry>Description</entry>
</row>
</thead>
<tbody>
<row>
<entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable>] <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry>
<entry>PCI slot number</entry>
</row>
<row>
<entry><replaceable>prefix</replaceable> <constant>v</constant><replaceable>slot</replaceable></entry>
<entry>VIO slot number (IBM PowerVM)</entry>
</row>
<row>
<entry><replaceable>prefix</replaceable> <constant>X</constant><replaceable>number</replaceable></entry>
<entry>VIF interface number (Xen)</entry>
</row>
<row>
<entry>… <constant>b</constant><replaceable>number</replaceable></entry>
<entry>Broadcom bus (BCMA) core number</entry>
</row>
<row>
<entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry>
<entry>USB port number chain</entry>
</row>
<row>
<entry>… <constant>v</constant><replaceable>slot</replaceable></entry>
<entry>SR-VIO slot number</entry>
</row>
<row>
<entry>… <constant>r</constant><replaceable>slot</replaceable></entry>
<entry>SR-IOV slot number</entry>
</row>
</tbody>
</tgroup>
</table>
<para>The PCI domain is only prepended when it is not 0. All multi-function PCI devices will carry
the <constant>f</constant><replaceable>function</replaceable> number in the device name, including
the function 0 device. For non-multi-function devices, the number is suppressed if 0. The port name
<replaceable>port_name</replaceable> is used, or the port number
<constant>d</constant><replaceable>dev_port</replaceable> if the name is not known.</para>
<para>For BCMA devices, the core number is suppressed when 0.</para>
<para>For USB devices the full chain of port numbers of hubs is composed. If the name gets longer
than the maximum number of 15 characters, the name is not exported. The usual USB configuration
number 1 and interface number 0 values are suppressed.</para>
<para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of
<constant>v</constant> and the virtual device number, with any leading zeros removed. The bus
number is ignored.</para>
<para>SR-IOV virtual device representors are named based on the name of the physical device
interface, with a suffix of <constant>r</constant> and the number of the virtual device that
is linked to the particular representor, with any leading zeros removed. The physical port
name and the bus number are ignored.</para>
<para>In some configurations a parent PCI bridge of a given network controller may be associated
with a slot. In such case we do not generate this device property to avoid possible naming conflicts.</para>
<xi:include href="version-info.xml" xpointer="v243"/>
</listitem>
</varlistentry>
<varlistentry>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable><constant>c</constant><replaceable>bus_id</replaceable></term>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable><constant>a</constant><replaceable>vendor</replaceable><replaceable>model</replaceable><constant>i</constant><replaceable>instance</replaceable></term>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable><constant>i</constant><replaceable>address</replaceable><constant>n</constant><replaceable>port_name</replaceable></term>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable><constant>u</constant><replaceable>port</replaceable>…</term>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]</term>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>b</constant><replaceable>number</replaceable></term>
<term><varname>ID_NET_NAME_PATH=</varname><replaceable>prefix</replaceable>[<constant>P</constant><replaceable>domain</replaceable>]<constant>p</constant><replaceable>bus</replaceable><constant>s</constant><replaceable>slot</replaceable>[<constant>f</constant><replaceable>function</replaceable>][<constant>n</constant><replaceable>phys_port_name</replaceable>|<constant>d</constant><replaceable>dev_port</replaceable>]<constant>u</constant><replaceable>port</replaceable>…[<constant>c</constant><replaceable>config</replaceable>][<constant>i</constant><replaceable>interface</replaceable>]</term>
<listitem><para>This property describes the device installation location. Different schemes are
used depending on the bus type, as described in the table below. For BCMA and USB devices, PCI path
information must known, and the full name consists of the prefix, PCI slot identifier, and USB or
BCMA location. The first two parts are denoted as "…" in the table below.</para>
<table>
<title>Path naming schemes</title>
<tgroup cols='2'>
<thead>
<row>
<entry>Format</entry>
<entry>Description</entry>
</row>
</thead>
<tbody>
<row>
<entry><replaceable>prefix</replaceable> <constant>c</constant><replaceable>bus_id</replaceable></entry>
<entry>CCW or grouped CCW device identifier</entry>
</row>
<row>
<entry><replaceable>prefix</replaceable> <constant>a</constant><replaceable>vendor</replaceable> <replaceable>model</replaceable> <constant>i</constant><replaceable>instance</replaceable></entry>
<entry>ACPI path names for ARM64 platform devices</entry>
</row>
<row>
<entry><replaceable>prefix</replaceable> <constant>i</constant><replaceable>address</replaceable> <constant>n</constant><replaceable>port_name</replaceable></entry>
<entry>Netdevsim (simulated networking device) device number and port name</entry>
</row>
<row>
<entry><replaceable>prefix</replaceable> [<constant>P</constant><replaceable>domain</replaceable>] <constant>p</constant><replaceable>bus</replaceable> <constant>s</constant><replaceable>slot</replaceable> [<constant>f</constant><replaceable>function</replaceable>] [<constant>n</constant><replaceable>phys_port_name</replaceable> | <constant>d</constant><replaceable>dev_port</replaceable>]</entry>
<entry>PCI geographical location</entry>
</row>
<row>
<entry>… <constant>b</constant><replaceable>number</replaceable></entry>
<entry>Broadcom bus (BCMA) core number</entry>
</row>
<row>
<entry>… <constant>u</constant><replaceable>port</replaceable>… [<constant>c</constant><replaceable>config</replaceable>] [<constant>i</constant><replaceable>interface</replaceable>]</entry>
<entry>USB port number chain</entry>
</row>
</tbody>
</tgroup>
</table>
<para>CCW and grouped CCW devices are found in IBM System Z mainframes. Any leading zeros and
dots are suppressed.</para>
<para>For PCI, BCMA, and USB devices, the same rules as described above for slot naming are
used.</para>
<xi:include href="version-info.xml" xpointer="v243"/>
</listitem>
</varlistentry>
</variablelist>
</refsect1>
<refsect1>
<title>History</title>
<para>The following "naming schemes" have been defined (which may be chosen at system boot-up time via
the <varname>net.naming_scheme=</varname> kernel command line switch, see above):</para>
<variablelist>
<varlistentry>
<term><constant>v238</constant></term>
<listitem><para>This is the naming scheme that was implemented in systemd 238.</para>
<xi:include href="version-info.xml" xpointer="v243"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>v239</constant></term>
<listitem><para>Naming was changed for virtual network interfaces created with SR-IOV and NPAR and
for devices where the PCI network controller device does not have a slot number associated.</para>
<para>SR-IOV virtual devices are named based on the name of the parent interface, with a suffix of
<literal>v<replaceable>port</replaceable></literal>, where <replaceable>port</replaceable> is the
virtual device number. Previously those virtual devices were named as if completely independent.
</para>
<para>The ninth and later NPAR virtual devices are named following the scheme used for the first
eight NPAR partitions. Previously those devices were not renamed and the kernel default
("eth<replaceable>N</replaceable>") was used.</para>
<para>Names are also generated for PCI devices where the PCI network controller device does not
have an associated slot number itself, but one of its parents does. Previously those devices were
not renamed and the kernel default was used.</para>
<xi:include href="version-info.xml" xpointer="v243"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v240</constant></term>
<listitem><para>The <literal>ib</literal> prefix and stable names for infiniband devices are
introduced. Previously those devices were not renamed.</para>
<para>The ACPI index field (used in <varname>ID_NET_NAME_ONBOARD=</varname>) is now also used when
0.</para>
<para>A new naming policy <varname>NamePolicy=keep</varname> was introduced. With this policy, if
the network device name was already set by userspace, the device will not be renamed
again. Previously, this naming policy applied implicitly, and now it must be explicitly
requested. Effectively, this means that network devices will be renamed according to the
configuration, even if they have been renamed already, if <constant>keep</constant> is not
specified as the naming policy in the <filename index="false">.link</filename> file. See
<citerefentry><refentrytitle>systemd.link</refentrytitle><manvolnum>5</manvolnum></citerefentry>
for a description of <varname>NamePolicy=</varname>.</para>
<xi:include href="version-info.xml" xpointer="v243"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>v241</constant></term>
<listitem><para><option>MACAddressPolicy=persistent</option> was extended to set MAC addresses
based on the device name. Previously addresses were only based on the
<varname index="false">ID_NET_NAME_*</varname> attributes, which meant that interface names would
never be generated for virtual devices. Now a persistent address will be generated for most
devices, including in particular bridges.</para>
<para>Note: when userspace does not set a MAC address for a bridge device, the kernel will
initially assign a random address, and then change it when the first device is enslaved to the
bridge. With this naming policy change, bridges get a persistent MAC address based on the bridge
name instead of the first enslaved device.</para>
<xi:include href="version-info.xml" xpointer="v243"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>v243</constant></term>
<listitem><para>Support for renaming netdevsim (simulated networking) devices was added. Previously
those devices were not renamed.</para>
<para>Previously two-letter interface type prefix was prepended to
<varname>ID_NET_LABEL_ONBOARD=</varname>. This is not done anymore.</para>
<xi:include href="version-info.xml" xpointer="v243"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>v245</constant></term>
<listitem><para>When
<citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry>
derives the name for the host side of the network interface created with
<option>--network-veth</option> from the container name it previously simply truncated the result
at 15 characters if longer (since that's the maximum length for network interface names). From now
on, for any interface name that would be longer than 15 characters the last 4 characters are set to
a 24bit hash value of the full interface name. This way network interface name collisions between
multiple similarly named containers (who only differ in container name suffix) should be less
likely (but still possible, since the 24bit hash value is very small).</para>
<xi:include href="version-info.xml" xpointer="v245"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>v247</constant></term>
<listitem><para>When a PCI slot is associated with a PCI bridge that has multiple child network
controllers, the same value of the <varname>ID_NET_NAME_SLOT</varname> property might be derived
for those controllers. This would cause a naming conflict if the property is selected as the device
name. Now, we detect this situation and do not produce the <varname>ID_NET_NAME_SLOT</varname>
property.</para>
<xi:include href="version-info.xml" xpointer="v247"/></listitem>
</varlistentry>
<varlistentry>
<term><constant>v249</constant></term>
<listitem><para>PCI hotplug slot names for the s390 PCI driver are a hexadecimal representation
of the <filename>function_id</filename> device attribute. This attribute is now used to build the
<varname>ID_NET_NAME_SLOT</varname>. Before that, all slot names were parsed as decimal
numbers, which could either result in an incorrect value of the <varname>ID_NET_NAME_SLOT</varname>
property or none at all.</para>
<para>Some firmware and hypervisor implementations report unreasonably high numbers for the
on-board index. To prevent the generation of bogus on-board interface names, index numbers greater
than 16381 (2¹⁴-1) were ignored. For s390 PCI devices index values up to 65535 (2¹⁶-1) are valid.
To account for that, the limit was increased to 65535.</para>
<para>The <citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry>
rule <varname>NAME=</varname> replaces <literal>:</literal>, <literal>/</literal>, and
<literal>%</literal> with an underscore (<literal>_</literal>), and refuses strings which contain
only digits.</para>
<xi:include href="version-info.xml" xpointer="v249"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v250</constant></term>
<listitem><para>Added naming scheme for Xen netfront "vif" interfaces based on the guest side
VIF number set from the Xen config (or the interface index in AWS EC2).</para>
<xi:include href="version-info.xml" xpointer="v250"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v251</constant></term>
<listitem><para>Since version <constant>v247</constant> we no longer set
<varname>ID_NET_NAME_SLOT</varname> if we detect that a PCI device associated with a slot is a PCI
bridge as that would create naming conflict when there are more child devices on that bridge. Now,
this is relaxed and we will use slot information to generate the name based on it but only if
the PCI device has multiple functions. This is safe because distinct function number is a part of
the device name for multifunction devices. Note, this is reverted in <constant>v255</constant>.
See below.</para>
<xi:include href="version-info.xml" xpointer="v251"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v252</constant></term>
<listitem><para>Added naming scheme for platform devices with devicetree aliases.</para>
<xi:include href="version-info.xml" xpointer="v252"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v253</constant></term>
<listitem><para>Set <varname>ID_NET_NAME_PATH</varname> for usb devices not connected via a PCI bus.</para>
<xi:include href="version-info.xml" xpointer="v253"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v254</constant></term>
<listitem><para>Naming was changed for SR-IOV virtual device representors, optionally settable at
compilation time. The <literal>r<replaceable>slot</replaceable></literal> suffix was added to
differentiate SR-IOV virtual device representors attached to a single physical device interface.
Because of a mistake, this scheme was <emphasis>not the default scheme for systemd version
254</emphasis>.</para>
<xi:include href="version-info.xml" xpointer="v255"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v255</constant></term>
<listitem><para>Naming was changed for SR-IOV virtual device representors to enable the
change introduced in <constant>v254</constant> by default.</para>
<para>If we detect that a PCI device associated with a slot is a PCI bridge, we no longer set
<varname>ID_NET_NAME_SLOT</varname>, reverting a change that was introduced in
<constant>v251</constant>.</para>
<xi:include href="version-info.xml" xpointer="v255"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v257</constant></term>
<listitem><para>PCI slot number is now read from <constant>firmware_node/sun</constant> sysfs file.</para>
<para>The naming scheme based on devicetree aliases was extended to support aliases for individual
interfaces of controllers with multiple ports.</para>
<xi:include href="version-info.xml" xpointer="v257"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v258</constant></term>
<listitem><para>When no renaming is requested, <varname>ID_NET_NAME</varname> property is now
equivalent to <varname>INTERFACE</varname> property.</para>
<xi:include href="version-info.xml" xpointer="v258"/>
</listitem>
</varlistentry>
<varlistentry>
<term><constant>v259</constant></term>
<listitem><para>The naming scheme based on devicetree aliases was extended to support WLAN devices.</para>
<xi:include href="version-info.xml" xpointer="v259"/>
</listitem>
</varlistentry>
</variablelist>
<para>Note that <constant>latest</constant> may be used to denote the latest scheme known (to this
particular version of systemd).</para>
</refsect1>
<refsect1>
<title>Limiting the use of specific sysfs attributes</title>
<para>When creating names for network cards, some naming schemes use data from sysfs populated by the
kernel. This means that although a specific naming scheme in
<citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry> is picked, the
network card's name can still change when a new kernel version adds a new sysfs attribute. For example,
if kernel starts setting the <constant>phys_port_name</constant>, <command>udev</command> will append the
"<constant>n</constant><replaceable>phys_port_name</replaceable>" suffix to the device name.</para>
<variablelist>
<varlistentry>
<term><varname>ID_NET_NAME_ALLOW=</varname><replaceable>BOOL</replaceable></term>
<listitem><para>This udev property sets a fallback policy for reading a sysfs attribute.
If set to <constant>0</constant> udev will not read any sysfs attribute by default, unless it is
explicitly allowlisted, see below. If set to <constant>1</constant> udev can use any sysfs attribute
unless it is explicitly forbidden. The default value is <constant>1</constant>.</para>
<xi:include href="version-info.xml" xpointer="v256"/>
</listitem>
</varlistentry>
<varlistentry>
<term><varname>ID_NET_NAME_ALLOW_<replaceable>sysfsattr</replaceable>=<replaceable>BOOL</replaceable></varname></term>
<listitem><para>This udev property explicitly states if udev shall use the specified
<replaceable>sysfsattr</replaceable>, when composing the device name.</para>
<xi:include href="version-info.xml" xpointer="v256"/>
</listitem>
</varlistentry>
</variablelist>
<para>With these options, users can set an allowlist or denylist for sysfs attributes. To create
an allowlist, the user needs to set <varname>ID_NET_NAME_ALLOW=0</varname> for the device and then list
the allowed attributes with the
<varname>ID_NET_NAME_ALLOW_<replaceable>sysfsattr</replaceable>=1</varname>
options. In case of a denylist, the user needs to provide the list of denied attributes with
the <varname>ID_NET_NAME_ALLOW_<replaceable>sysfsattr</replaceable>=0</varname> options.</para>
</refsect1>
<refsect1>
<title>Examples</title>
<example>
<title>Using <command>udevadm test-builtin</command> to display device properties</title>
<programlisting>$ udevadm test-builtin net_id /sys/class/net/enp0s31f6
...
Using default interface naming scheme 'v243'.
ID_NET_NAMING_SCHEME=v243
ID_NET_NAME_MAC=enx54ee75cb1dc0
ID_OUI_FROM_DATABASE=Wistron InfoComm(Kunshan)Co.,Ltd.
ID_NET_NAME_PATH=enp0s31f6
...</programlisting>
</example>
<example>
<title>PCI Ethernet card with firmware index "1"</title>
<programlisting>ID_NET_NAME_ONBOARD=eno1
ID_NET_NAME_ONBOARD_LABEL=Ethernet Port 1
</programlisting>
</example>
<example>
<title>PCI Ethernet card in slot with firmware index number</title>
<programlisting># /sys/devices/pci0000:00/0000:00:1c.3/0000:05:00.0/net/ens1
ID_NET_NAME_MAC=enx000000000466
ID_NET_NAME_PATH=enp5s0
ID_NET_NAME_SLOT=ens1</programlisting>
</example>
<example>
<title>PCI Ethernet multi-function card with 2 ports</title>
<programlisting># /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.0/net/enp2s0f0
ID_NET_NAME_MAC=enx78e7d1ea46da
ID_NET_NAME_PATH=enp2s0f0
# /sys/devices/pci0000:00/0000:00:1c.0/0000:02:00.1/net/enp2s0f1
ID_NET_NAME_MAC=enx78e7d1ea46dc
ID_NET_NAME_PATH=enp2s0f1</programlisting>
</example>
<example>
<title>PCI WLAN card</title>
<programlisting># /sys/devices/pci0000:00/0000:00:1c.1/0000:03:00.0/net/wlp3s0
ID_NET_NAME_MAC=wlx0024d7e31130
ID_NET_NAME_PATH=wlp3s0</programlisting>
</example>
<example>
<title>PCI IB host adapter with 2 ports</title>
<programlisting># /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.0/net/ibp21s0f0
ID_NET_NAME_PATH=ibp21s0f0
# /sys/devices/pci0000:00/0000:00:03.0/0000:15:00.1/net/ibp21s0f1
ID_NET_NAME_PATH=ibp21s0f1</programlisting>
</example>
<example>
<title>USB built-in 3G modem</title>
<programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.4/2-1.4:1.6/net/wwp0s29u1u4i6
ID_NET_NAME_MAC=wwx028037ec0200
ID_NET_NAME_PATH=wwp0s29u1u4i6</programlisting>
</example>
<example>
<title>USB Android phone</title>
<programlisting># /sys/devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.2/2-1.2:1.0/net/enp0s29u1u2
ID_NET_NAME_MAC=enxd626b3450fb5
ID_NET_NAME_PATH=enp0s29u1u2</programlisting>
</example>
<example>
<title>s390 grouped CCW interface</title>
<programlisting># /sys/devices/css0/0.0.0007/0.0.f5f0/group_device/net/encf5f0
ID_NET_NAME_MAC=enx026d3c00000a
ID_NET_NAME_PATH=encf5f0</programlisting>
</example>
<example>
<title>Set an allowlist for reading sysfs attributes for network card naming</title>
<programlisting><filename>/etc/udev/hwdb.d/50-net-naming-allowlist.hwdb</filename>
net:naming:drvirtio_net:*
ID_NET_NAME_ALLOW=0
ID_NET_NAME_ALLOW_ACPI_INDEX=1
ID_NET_NAME_ALLOW_ADDR_ASSIGN_TYPE=1
ID_NET_NAME_ALLOW_ADDRESS=1
ID_NET_NAME_ALLOW_ARI_ENABLED=1
ID_NET_NAME_ALLOW_DEV_PORT=1
ID_NET_NAME_ALLOW_FUNCTION_ID=1
ID_NET_NAME_ALLOW_IFLINK=1
ID_NET_NAME_ALLOW_INDEX=1
ID_NET_NAME_ALLOW_LABEL=1
ID_NET_NAME_ALLOW_PHYS_PORT_NAME=1
ID_NET_NAME_ALLOW_TYPE=1</programlisting>
</example>
<example>
<title>Set a denylist so that specified sysfs attribute are ignored</title>
<programlisting><filename>/etc/udev/hwdb.d/50-net-naming-denylist.hwdb</filename>
net:naming:drvirtio_net:*
ID_NET_NAME_ALLOW=1
ID_NET_NAME_ALLOW_DEV_PORT=0
ID_NET_NAME_ALLOW_PHYS_PORT_NAME=0
</programlisting>
</example>
</refsect1>
<refsect1>
<title>See Also</title>
<para><simplelist type="inline">
<member><citerefentry><refentrytitle>udev</refentrytitle><manvolnum>7</manvolnum></citerefentry></member>
<member><citerefentry><refentrytitle>udevadm</refentrytitle><manvolnum>8</manvolnum></citerefentry></member>
<member><citerefentry><refentrytitle>systemd-udevd.service</refentrytitle><manvolnum>8</manvolnum></citerefentry></member>
<member><ulink url="https://systemd.io/PREDICTABLE_INTERFACE_NAMES">Predictable Network Interface Names</ulink></member>
<member><citerefentry><refentrytitle>systemd-nspawn</refentrytitle><manvolnum>1</manvolnum></citerefentry></member>
</simplelist></para>
</refsect1>