// Copyright 2011 Ettus Research LLC
// Copyright 2018 Ettus Research, a National Instruments Company
//
// SPDX-License-Identifier: LGPL-3.0-or-later
//
// The purpose of this module is to synchronize a reset from one clock domain
// to another. The reset_in signal must be driven by a glitch-free source.
//
module reset_sync (
// clock for the output reset
input clk,
// glitch-free input reset
input reset_in,
// output reset in the clk domain
output reset_out);
synchronizer #(
// The input reset is async to the output clk domain... so timing should not be
// analyzed here!
.FALSE_PATH_TO_IN(1),
// Assert reset_out by default. When clk starts toggling the downstream logic will
// be in reset for at least 10 clk cycles. This allows the clock to settle (if needed)
// and the reset to propagate fully to all logic.
.INITIAL_VAL(1),
.STAGES(10)
) reset_double_sync (
.clk(clk), .rst(1'b0), .in(reset_in), .out(reset_out)
);