File: prerm

package info (click to toggle)
wdm 1.28-26
  • links: PTS, VCS
  • area: main
  • in suites: bookworm
  • size: 2,516 kB
  • sloc: ansic: 11,439; sh: 1,033; makefile: 377; perl: 32; cpp: 10
file content (202 lines) | stat: -rw-r--r-- 6,396 bytes parent folder | download | duplicates (7)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
#!/bin/sh
# Debian wdm package pre-removal script
# Copyright 2001 Branden Robinson.
# Copyright 2005 Vladimir Shakhov.
# Licensed under the GNU General Public License, version 2.  See the file
# /usr/share/common-licenses/GPL or <http://www.gnu.org/copyleft/gpl.txt>.
# Acknowlegements to Stephen Early, Mark Eichin, and Manoj Srivastava.

set -e

THIS_PACKAGE=wdm
DEFAULT_DISPLAY_MANAGER_FILE=/etc/X11/default-display-manager

HAVE_DEBCONF=
if [ -e /usr/share/debconf/confmodule ]; then
  . /usr/share/debconf/confmodule
  HAVE_DEBCONF=yes
fi

message () {
  # pretty-print messages of arbitrary length
  echo "$*" | fold -s -w ${COLUMNS:-80} >&2;
}

message_nonl () {
  # pretty-print messages of arbitrary length (no trailing newline)
  echo -n "$*" | fold -s -w ${COLUMNS:-80} >&2;
}

errormsg () {
  # exit script with error
  message "$*"
  exit 1;
}

parseans () {
  if [ ! $1 ]; then
    echo $DEFAULT
  else
    echo $1 | cut -c1 | tr '[A-Z]' '[a-z]';
  fi;
}

trap "message ;\
      message 'Received signal.  Aborting wdm package prerm script.' ;\
      message ;\
      exit 1" 1 2 3 15

case "$1" in
  # we NEVER want to stop wdm without doing some checks first, see below
  upgrade|failed-upgrade)
    REMOVING=
    ;;
  remove|deconfigure)
    REMOVING=yes
    ;;
esac

STOP=
# are we supposed to restart on upgrade?  if REMOVING wdm, we don't care
if grep -qs ^restart-on-upgrade /etc/X11/wdm/wdm.options || [ -n "$REMOVING" ]; then
  # is there an wdm process running?
  if start-stop-daemon --stop --quiet --signal 0 --exec /usr/bin/wdm; then
    # any children?
    PARENTS=$(pidof /usr/bin/wdm || true)
    CHILDREN=
    for PROCESS in $PARENTS; do
      # make sure we got numbers back
      if ! [ $PROCESS -eq $PROCESS ] 2> /dev/null; then
        # freak out
        errormsg "ERROR: pidof returned non-numeric value!"
      fi
      # we could use grep -q here if ps would ignore SIGPIPE :-P
      if (ps axj | grep "^ *$PROCESS" > /dev/null 2>&1); then
        CHILDREN=yes
      fi
    done
    if [ -n "$CHILDREN" ]; then
      #message "WARNING: Preparing to stop WINGs display manager (wdm) daemon," \
       #       "and it appears to be managing at least one running X" \
        #      "session.  If wdm is stopped now, any X sessions it manages" \
       #       "will be terminated.  Otherwise you may leave wdm running," \
        #      "and the new version will take effect the next time wdm is" \
         #     "restarted."
      message "WARNING: Preparing to stop WINGs display manager (wdm) daemon"
      DEFAULT=n
      VALID_ANSWER=
      while [ -z "$VALID_ANSWER" ]; do
        #message_nonl "Do you wish to stop the wdm daemon? (y/n) [$DEFAULT] "
        #read ANSWER # because failed to tun
        ANSWER=y
        ANSWER=$(parseans $ANSWER)
        case "$ANSWER" in
          y) VALID_ANSWER=true; STOP=yes ;;
          n) VALID_ANSWER=true ;;
          *) message "\"$ANSWER\" not understood." ;;
        esac
      done
    else
      STOP=yes
    fi
  fi
fi

if [ -n "$STOP" ]; then
  if which invoke-rc.d >/dev/null 2>&1; then
    invoke-rc.d wdm stop
  else
    /etc/init.d/wdm stop || true
  fi
else
  if [ "$1" = "upgrade" -o "$1" = "failed-upgrade" ]; then
    touch /var/run/wdm.upgrade
  fi
fi

if [ "$1" = "remove" -o "$1" = "deconfigure" ]; then
  if [ -n "$HAVE_DEBCONF" ]; then
    # disown this question
    db_unregister shared/default-x-display-manager
    # does the question still exist?
    if db_get shared/default-x-display-manager; then
      if db_metaget shared/default-x-display-manager owners; then
        # FIXME - redo this part uses shell-lib.sh from xfree86
        #observe "X display managers now available are \"$OWNERS\""
	db_subst shared/default-x-display-manager choices "$RET"
      fi
      DEFAULT_DISPLAY_MANAGER=
      if db_get shared/default-x-display-manager; then
	DEFAULT_DISPLAY_MANAGER="$RET"
      fi
      # are we removing the currently selected display manager?
      if [ -n "$DEFAULT_DISPLAY_MANAGER" ]; then
	if [ "$THIS_PACKAGE" = "$DEFAULT_DISPLAY_MANAGER" ]; then
	  if [ -e "$DEFAULT_DISPLAY_MANAGER_FILE" ]; then
	    if db_get "$DEFAULT_DISPLAY_MANAGER/daemon_name"; then
              # does the display manager file reference the current default?
              # if so, remove it because it will now be wrong
	      if [ -n "$RET" ]; then
		if [ "$(cat "$DEFAULT_DISPLAY_MANAGER_FILE")" = "$RET" ]; then
		  rm "$DEFAULT_DISPLAY_MANAGER_FILE"
		fi
	      fi
	    fi
	  fi
          # ask the user to choose a new default
	  db_fset shared/default-x-display-manager seen false
	  db_input critical shared/default-x-display-manager || true
	  db_go
          # if the default display manager file doesn't exist, write it with
          # the path to the new default display manager
	  if [ ! -e "$DEFAULT_DISPLAY_MANAGER_FILE" ]; then
	    DEFAULT_DISPLAY_MANAGER=
	    if db_get shared/default-x-display-manager; then
	      DEFAULT_DISPLAY_MANAGER="$RET"
	    fi
	    if [ -n "$DEFAULT_DISPLAY_MANAGER" ]; then
              # FIXME - redo this part uses shell-lib.sh from xfree86
              #warn "new default display manager has been selected; " \
              #     "please be sure to run \"dpkg-reconfigure $RET\" " \
              #     "to ensure that it is configured"
              DAEMON_NAME=
              if db_get "$DEFAULT_DISPLAY_MANAGER"/daemon_name; then
		DAEMON_NAME="$RET"
              fi
              if [ ! -n "$DAEMON_NAME" ]; then
                # if we were unable to determine the name of the selected
                # daemon (for instance, if the selected default display
								# manager doesn't provide a daemon_name question), guess
		DAEMON_NAME=$(which "$DEFAULT_DISPLAY_MANAGER" 2>/dev/null)
		if [ ! -n "$DAEMON_NAME" ]; then
		  echo .
                  # FIXME - redo this part uses shell-lib.sh from xfree86
                  #warn "unable to determine path to default X display manager"
		  \
		    #     "$DEFAULT_DISPLAY_MANAGER; not updating" \
                  #     "$DEFAULT_DISPLAY_MANAGER_FILE"
		fi
              fi
              if [ -n "$DAEMON_NAME" ]; then
		echo "$DAEMON_NAME" > "$DEFAULT_DISPLAY_MANAGER_FILE"
              fi
	    fi
	  fi
	fi
      fi
    fi
  fi
fi


#DEBHELPER#

exit 0

# vim:set ai et sts=2 sw=2 tw=0:

# Local Variables:
# mode: shell-script
# sh-indentation: 2
# sh-basic-offset: 2
# End: