1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
|
This is a means of exposing various controls to NRPNs.
All of the commands produce log output in a manner designed to be compatible with
both the GUI reports window and with a CLI readline environment.
To access these, set NRPN MSB (CC 99) to 64 and NRPN LSB (CC 98) to 2 (8130). After
that send the following Data values.
Data MSB Data LSB Setting
2 key Set master key shift, key-64 (-36 to +36)
7 volume Set master Volume ’volume’
64 to 79 key Set channel (MSB-64) key shift, key-64 (-36 to +36)
80 root Set CC to control Root path change (>119 disables)
81 bank Set CC to control Bank change (>119 disables)
82 >63 Enable Program change otherwise disable
83 >63 Reserved
84 extended Set CC control Extended program change (>119 disables)
85 parts Set number of available parts (16, 32 or 64)
86 0 Save all dynamic settings
|