1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651
|
/*
* yosys -- Yosys Open SYnthesis Suite
*
* Copyright (C) 2017 Clifford Wolf <clifford@clifford.at>
*
* Permission to use, copy, modify, and/or distribute this software for any
* purpose with or without fee is hereby granted, provided that the above
* copyright notice and this permission notice appear in all copies.
*
* THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES
* WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF
* MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR
* ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES
* WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN
* ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF
* OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE.
*
*/
#include "kernel/yosys.h"
#include "kernel/sigtools.h"
#include "kernel/modtools.h"
USING_YOSYS_NAMESPACE
PRIVATE_NAMESPACE_BEGIN
//get the list of cells hooked up to at least one bit of a given net
pool<Cell*> get_other_cells(const RTLIL::SigSpec& port, ModIndex& index, Cell* src)
{
pool<Cell*> rval;
for(auto b : port)
{
pool<ModIndex::PortInfo> ports = index.query_ports(b);
for(auto x : ports)
{
if(x.cell == src)
continue;
rval.insert(x.cell);
}
}
return rval;
}
//return true if there is a full-width bus connection from cell a port ap to cell b port bp
//if other_conns_allowed is false, then we require a strict point to point connection (no other links)
bool is_full_bus(
const RTLIL::SigSpec& sig,
ModIndex& index,
Cell* a,
RTLIL::IdString ap,
Cell* b,
RTLIL::IdString bp,
bool other_conns_allowed = false)
{
for(auto s : sig)
{
pool<ModIndex::PortInfo> ports = index.query_ports(s);
bool found_a = false;
bool found_b = false;
for(auto x : ports)
{
if( (x.cell == a) && (x.port == ap) )
found_a = true;
else if( (x.cell == b) && (x.port == bp) )
found_b = true;
else if(!other_conns_allowed)
return false;
}
if( (!found_a) || (!found_b) )
return false;
}
return true;
}
//return true if the signal connects to one port only (nothing on the other end)
bool is_unconnected(const RTLIL::SigSpec& port, ModIndex& index)
{
for(auto b : port)
{
pool<ModIndex::PortInfo> ports = index.query_ports(b);
if(ports.size() > 1)
return false;
}
return true;
}
struct CounterExtraction
{
int width; //counter width
RTLIL::Wire* rwire; //the register output
bool has_reset; //true if we have a reset
bool has_ce; //true if we have a clock enable
RTLIL::SigSpec rst; //reset pin
bool rst_inverted; //true if reset is active low
bool rst_to_max; //true if we reset to max instead of 0
int count_value; //value we count from
RTLIL::SigSpec ce; //clock signal
RTLIL::SigSpec clk; //clock enable, if any
RTLIL::SigSpec outsig; //counter output signal
RTLIL::Cell* count_mux; //counter mux
RTLIL::Cell* count_reg; //counter register
RTLIL::Cell* underflow_inv; //inverter reduction for output-underflow detect
pool<ModIndex::PortInfo> pouts; //Ports that take a parallel output from us
};
//attempt to extract a counter centered on the given adder cell
//For now we only support DOWN counters.
//TODO: up/down support
int counter_tryextract(
ModIndex& index,
Cell *cell,
CounterExtraction& extract,
pool<RTLIL::IdString>& parallel_cells,
int maxwidth)
{
SigMap& sigmap = index.sigmap;
//A counter with less than 2 bits makes no sense
//TODO: configurable min threshold
int a_width = cell->getParam("\\A_WIDTH").as_int();
extract.width = a_width;
if( (a_width < 2) || (a_width > maxwidth) )
return 1;
//Second input must be a single bit
int b_width = cell->getParam("\\B_WIDTH").as_int();
if(b_width != 1)
return 2;
//Both inputs must be unsigned, so don't extract anything with a signed input
bool a_sign = cell->getParam("\\A_SIGNED").as_bool();
bool b_sign = cell->getParam("\\B_SIGNED").as_bool();
if(a_sign || b_sign)
return 3;
//To be a counter, one input of the ALU must be a constant 1
//TODO: can A or B be swapped in synthesized RTL or is B always the 1?
const RTLIL::SigSpec b_port = sigmap(cell->getPort("\\B"));
if(!b_port.is_fully_const() || (b_port.as_int() != 1) )
return 4;
//BI and CI must be constant 1 as well
const RTLIL::SigSpec bi_port = sigmap(cell->getPort("\\BI"));
if(!bi_port.is_fully_const() || (bi_port.as_int() != 1) )
return 5;
const RTLIL::SigSpec ci_port = sigmap(cell->getPort("\\CI"));
if(!ci_port.is_fully_const() || (ci_port.as_int() != 1) )
return 6;
//CO and X must be unconnected (exactly one connection to each port)
if(!is_unconnected(sigmap(cell->getPort("\\CO")), index))
return 7;
if(!is_unconnected(sigmap(cell->getPort("\\X")), index))
return 8;
//Y must have exactly one connection, and it has to be a $mux cell.
//We must have a direct bus connection from our Y to their A.
const RTLIL::SigSpec aluy = sigmap(cell->getPort("\\Y"));
pool<Cell*> y_loads = get_other_cells(aluy, index, cell);
if(y_loads.size() != 1)
return 9;
Cell* count_mux = *y_loads.begin();
extract.count_mux = count_mux;
if(count_mux->type != "$mux")
return 10;
if(!is_full_bus(aluy, index, cell, "\\Y", count_mux, "\\A"))
return 11;
//B connection of the mux is our underflow value
const RTLIL::SigSpec underflow = sigmap(count_mux->getPort("\\B"));
if(!underflow.is_fully_const())
return 12;
extract.count_value = underflow.as_int();
//S connection of the mux must come from an inverter (need not be the only load)
const RTLIL::SigSpec muxsel = sigmap(count_mux->getPort("\\S"));
extract.outsig = muxsel;
pool<Cell*> muxsel_conns = get_other_cells(muxsel, index, count_mux);
Cell* underflow_inv = NULL;
for(auto c : muxsel_conns)
{
if(c->type != "$logic_not")
continue;
if(!is_full_bus(muxsel, index, c, "\\Y", count_mux, "\\S", true))
continue;
underflow_inv = c;
break;
}
if(underflow_inv == NULL)
return 13;
extract.underflow_inv = underflow_inv;
//Y connection of the mux must have exactly one load, the counter's internal register, if there's no clock enable
//If we have a clock enable, Y drives the B input of a mux. A of that mux must come from our register
const RTLIL::SigSpec muxy = sigmap(count_mux->getPort("\\Y"));
pool<Cell*> muxy_loads = get_other_cells(muxy, index, count_mux);
if(muxy_loads.size() != 1)
return 14;
Cell* muxload = *muxy_loads.begin();
Cell* count_reg = muxload;
Cell* cemux = NULL;
RTLIL::SigSpec cey;
if(muxload->type == "$mux")
{
//This mux is probably a clock enable mux.
//Find our count register (should be our only load)
cemux = muxload;
cey = sigmap(cemux->getPort("\\Y"));
pool<Cell*> cey_loads = get_other_cells(cey, index, cemux);
if(cey_loads.size() != 1)
return 24;
count_reg = *cey_loads.begin();
//Mux should have A driven by count Q, and B by muxy
//TODO: if A and B are swapped, CE polarity is inverted
if(sigmap(cemux->getPort("\\B")) != muxy)
return 24;
if(sigmap(cemux->getPort("\\A")) != sigmap(count_reg->getPort("\\Q")))
return 24;
if(sigmap(cemux->getPort("\\Y")) != sigmap(count_reg->getPort("\\D")))
return 24;
//Select of the mux is our clock enable
extract.has_ce = true;
extract.ce = sigmap(cemux->getPort("\\S"));
}
else
extract.has_ce = false;
extract.count_reg = count_reg;
if(count_reg->type == "$dff")
extract.has_reset = false;
else if(count_reg->type == "$adff")
{
extract.has_reset = true;
//Check polarity of reset - we may have to add an inverter later on!
extract.rst_inverted = (count_reg->getParam("\\ARST_POLARITY").as_int() != 1);
//Verify ARST_VALUE is zero or full scale
int rst_value = count_reg->getParam("\\ARST_VALUE").as_int();
if(rst_value == 0)
extract.rst_to_max = false;
else if(rst_value == extract.count_value)
extract.rst_to_max = true;
else
return 23;
//Save the reset
extract.rst = sigmap(count_reg->getPort("\\ARST"));
}
//TODO: support synchronous reset
else
return 15;
//Sanity check that we use the ALU output properly
if(extract.has_ce)
{
if(!is_full_bus(muxy, index, count_mux, "\\Y", cemux, "\\B"))
return 16;
if(!is_full_bus(cey, index, cemux, "\\Y", count_reg, "\\D"))
return 16;
}
else if(!is_full_bus(muxy, index, count_mux, "\\Y", count_reg, "\\D"))
return 16;
//TODO: Verify count_reg CLK_POLARITY is 1
//Register output must have exactly two loads, the inverter and ALU
//(unless we have a parallel output!)
//If we have a clock enable, 3 is OK
const RTLIL::SigSpec qport = count_reg->getPort("\\Q");
const RTLIL::SigSpec cnout = sigmap(qport);
pool<Cell*> cnout_loads = get_other_cells(cnout, index, count_reg);
unsigned int max_loads = 2;
if(extract.has_ce)
max_loads = 3;
if(cnout_loads.size() > max_loads)
{
for(auto c : cnout_loads)
{
if(c == underflow_inv)
continue;
if(c == cell)
continue;
if(c == muxload)
continue;
//If we specified a limited set of cells for parallel output, check that we only drive them
if(!parallel_cells.empty())
{
//Make sure we're in the whitelist
if( parallel_cells.find(c->type) == parallel_cells.end())
return 17;
}
//Figure out what port(s) are driven by it
//TODO: this can probably be done more efficiently w/o multiple iterations over our whole net?
for(auto b : qport)
{
pool<ModIndex::PortInfo> ports = index.query_ports(b);
for(auto x : ports)
{
if(x.cell != c)
continue;
extract.pouts.insert(ModIndex::PortInfo(c, x.port, 0));
}
}
}
}
if(!is_full_bus(cnout, index, count_reg, "\\Q", underflow_inv, "\\A", true))
return 18;
if(!is_full_bus(cnout, index, count_reg, "\\Q", cell, "\\A", true))
return 19;
//Look up the clock from the register
extract.clk = sigmap(count_reg->getPort("\\CLK"));
//Register output net must have an INIT attribute equal to the count value
extract.rwire = cnout.as_wire();
if(extract.rwire->attributes.find("\\init") == extract.rwire->attributes.end())
return 20;
int rinit = extract.rwire->attributes["\\init"].as_int();
if(rinit != extract.count_value)
return 21;
return 0;
}
void counter_worker(
ModIndex& index,
Cell *cell,
unsigned int& total_counters,
pool<Cell*>& cells_to_remove,
pool<pair<Cell*, string>>& cells_to_rename,
pool<RTLIL::IdString>& parallel_cells,
int maxwidth)
{
SigMap& sigmap = index.sigmap;
//Core of the counter must be an ALU
if (cell->type != "$alu")
return;
//A input is the count value. Check if it has COUNT_EXTRACT set.
//If it's not a wire, don't even try
auto port = sigmap(cell->getPort("\\A"));
if(!port.is_wire())
return;
RTLIL::Wire* a_wire = port.as_wire();
bool force_extract = false;
bool never_extract = false;
string count_reg_src = a_wire->attributes["\\src"].decode_string().c_str();
if(a_wire->attributes.find("\\COUNT_EXTRACT") != a_wire->attributes.end())
{
pool<string> sa = a_wire->get_strpool_attribute("\\COUNT_EXTRACT");
string extract_value;
if(sa.size() >= 1)
{
extract_value = *sa.begin();
log(" Signal %s declared at %s has COUNT_EXTRACT = %s\n",
log_id(a_wire),
count_reg_src.c_str(),
extract_value.c_str());
if(extract_value == "FORCE")
force_extract = true;
else if(extract_value == "NO")
never_extract = true;
else if(extract_value == "AUTO")
{} //default
else
log_error(" Illegal COUNT_EXTRACT value %s (must be one of FORCE, NO, AUTO)\n",
extract_value.c_str());
}
}
//If we're explicitly told not to extract, don't infer a counter
if(never_extract)
return;
//Attempt to extract a counter
CounterExtraction extract;
int reason = counter_tryextract(index, cell, extract, parallel_cells, maxwidth);
//Nonzero code - we could not find a matchable counter.
//Do nothing, unless extraction was forced in which case give an error
if(reason != 0)
{
static const char* reasons[25]=
{
"no problem", //0
"counter is too large/small", //1
"counter does not count by one", //2
"counter uses signed math", //3
"counter does not count by one", //4
"ALU is not a subtractor", //5
"ALU is not a subtractor", //6
"ALU ports used outside counter", //7
"ALU ports used outside counter", //8
"ALU output used outside counter", //9
"ALU output is not a mux", //10
"ALU output is not full bus", //11
"Underflow value is not constant", //12
"No underflow detector found", //13
"Mux output is used outside counter", //14
"Counter reg is not DFF/ADFF", //15
"Counter input is not full bus", //16
"Count register is used outside counter, but not by an allowed cell", //17
"Register output is not full bus", //18
"Register output is not full bus", //19
"No init value found", //20
"Underflow value is not equal to init value", //21
"RESERVED, not implemented", //22, kept for compatibility but not used anymore
"Reset is not to zero or COUNT_TO", //23
"Clock enable configuration is unsupported" //24
};
if(force_extract)
{
log_error(
"Counter extraction is set to FORCE on register %s, but a counter could not be inferred (%s)\n",
log_id(a_wire),
reasons[reason]);
}
return;
}
//Get new cell name
string countname = string("$COUNTx$") + log_id(extract.rwire->name.str());
//Wipe all of the old connections to the ALU
cell->unsetPort("\\A");
cell->unsetPort("\\B");
cell->unsetPort("\\BI");
cell->unsetPort("\\CI");
cell->unsetPort("\\CO");
cell->unsetPort("\\X");
cell->unsetPort("\\Y");
cell->unsetParam("\\A_SIGNED");
cell->unsetParam("\\A_WIDTH");
cell->unsetParam("\\B_SIGNED");
cell->unsetParam("\\B_WIDTH");
cell->unsetParam("\\Y_WIDTH");
//Change the cell type
cell->type = "$__COUNT_";
//Hook up resets
if(extract.has_reset)
{
//TODO: support other kinds of reset
cell->setParam("\\RESET_MODE", RTLIL::Const("LEVEL"));
//If the reset is active low, infer an inverter ($__COUNT_ cells always have active high reset)
if(extract.rst_inverted)
{
auto realreset = cell->module->addWire(NEW_ID);
cell->module->addNot(NEW_ID, extract.rst, RTLIL::SigSpec(realreset));
cell->setPort("\\RST", realreset);
}
else
cell->setPort("\\RST", extract.rst);
}
else
{
cell->setParam("\\RESET_MODE", RTLIL::Const("RISING"));
cell->setPort("\\RST", RTLIL::SigSpec(false));
}
//Hook up other stuff
//cell->setParam("\\CLKIN_DIVIDE", RTLIL::Const(1));
cell->setParam("\\COUNT_TO", RTLIL::Const(extract.count_value));
cell->setParam("\\WIDTH", RTLIL::Const(extract.width));
cell->setPort("\\CLK", extract.clk);
cell->setPort("\\OUT", extract.outsig);
//Hook up clock enable
if(extract.has_ce)
{
cell->setParam("\\HAS_CE", RTLIL::Const(1));
cell->setPort("\\CE", extract.ce);
}
else
cell->setParam("\\HAS_CE", RTLIL::Const(0));
//Hook up hard-wired ports (for now up/down are not supported), default to no parallel output
cell->setParam("\\HAS_POUT", RTLIL::Const(0));
cell->setParam("\\RESET_TO_MAX", RTLIL::Const(0));
cell->setParam("\\DIRECTION", RTLIL::Const("DOWN"));
cell->setPort("\\CE", RTLIL::Const(1));
cell->setPort("\\UP", RTLIL::Const(0));
//Hook up any parallel outputs
for(auto load : extract.pouts)
{
log(" Counter has parallel output to cell %s port %s\n", log_id(load.cell->name), log_id(load.port));
//Find the wire hooked to the old port
auto sig = load.cell->getPort(load.port);
//Connect it to our parallel output
//(this is OK to do more than once b/c they all go to the same place)
cell->setPort("\\POUT", sig);
cell->setParam("\\HAS_POUT", RTLIL::Const(1));
}
//Delete the cells we've replaced (let opt_clean handle deleting the now-redundant wires)
cells_to_remove.insert(extract.count_mux);
cells_to_remove.insert(extract.count_reg);
cells_to_remove.insert(extract.underflow_inv);
//Log it
total_counters ++;
string reset_type = "non-resettable";
if(extract.has_reset)
{
if(extract.rst_inverted)
reset_type = "negative";
else
reset_type = "positive";
//TODO: support other kind of reset
reset_type += " async resettable";
}
log(" Found %d-bit (%s) down counter %s (counting from %d) for register %s, declared at %s\n",
extract.width,
reset_type.c_str(),
countname.c_str(),
extract.count_value,
log_id(extract.rwire->name),
count_reg_src.c_str());
//Optimize the counter
//If we have no parallel output, and we have redundant bits, shrink us
if(extract.pouts.empty())
{
//TODO: Need to update this when we add support for counters with nonzero reset values
//to make sure the reset value fits in our bit space too
//Optimize it
int newbits = ceil(log2(extract.count_value));
if(extract.width != newbits)
{
cell->setParam("\\WIDTH", RTLIL::Const(newbits));
log(" Optimizing out %d unused high-order bits (new width is %d)\n",
extract.width - newbits,
newbits);
}
}
//Finally, rename the cell
cells_to_rename.insert(pair<Cell*, string>(cell, countname));
}
struct ExtractCounterPass : public Pass {
ExtractCounterPass() : Pass("extract_counter", "Extract GreenPak4 counter cells") { }
void help() YS_OVERRIDE
{
// |---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|
log("\n");
log(" extract_counter [options] [selection]\n");
log("\n");
log("This pass converts non-resettable or async resettable down counters to\n");
log("counter cells. Use a target-specific 'techmap' map file to convert those cells\n");
log("to the actual target cells.\n");
log("\n");
log(" -maxwidth N\n");
log(" Only extract counters up to N bits wide\n");
log("\n");
log(" -pout X,Y,...\n");
log(" Only allow parallel output from the counter to the listed cell types\n");
log(" (if not specified, parallel outputs are not restricted)\n");
log("\n");
log("\n");
}
void execute(std::vector<std::string> args, RTLIL::Design *design) YS_OVERRIDE
{
log_header(design, "Executing EXTRACT_COUNTER pass (find counters in netlist).\n");
int maxwidth = 64;
size_t argidx;
pool<RTLIL::IdString> parallel_cells;
for (argidx = 1; argidx < args.size(); argidx++)
{
if (args[argidx] == "-pout")
{
if(argidx + 1 >= args.size())
{
log_error("extract_counter -pout requires an argument\n");
return;
}
std::string pouts = args[++argidx];
std::string tmp;
for(size_t i=0; i<pouts.length(); i++)
{
if(pouts[i] == ',')
{
parallel_cells.insert(RTLIL::escape_id(tmp));
tmp = "";
}
else
tmp += pouts[i];
}
parallel_cells.insert(RTLIL::escape_id(tmp));
continue;
}
if (args[argidx] == "-maxwidth" && argidx+1 < args.size())
{
maxwidth = atoi(args[++argidx].c_str());
continue;
}
}
extra_args(args, argidx, design);
//Extract all of the counters we could find
unsigned int total_counters = 0;
for (auto module : design->selected_modules())
{
pool<Cell*> cells_to_remove;
pool<pair<Cell*, string>> cells_to_rename;
ModIndex index(module);
for (auto cell : module->selected_cells())
counter_worker(index, cell, total_counters, cells_to_remove, cells_to_rename, parallel_cells, maxwidth);
for(auto cell : cells_to_remove)
{
//log("Removing cell %s\n", log_id(cell->name));
module->remove(cell);
}
for(auto cpair : cells_to_rename)
{
//log("Renaming cell %s to %s\n", log_id(cpair.first->name), cpair.second.c_str());
module->rename(cpair.first, cpair.second);
}
}
if(total_counters)
log("Extracted %u counters\n", total_counters);
}
} ExtractCounterPass;
PRIVATE_NAMESPACE_END
|